POWER-SYSTEMS PS-LD0101-1-080

LED-CONVERTER UNIT
PS-LD0101-x-yyy(S) (9 W)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile LED-Converter is developed for max. 1 LED-line
APPLICABLE:
1 LED line
Pout
LED Voltage
Lamp Current
Input Voltage
max. 9 Watt
max. 35V
max. 300 mAdc
10.8 ~ 13.2 Vdc
FEATURES :
Connector style
Independent Open LED Detection
Voltage or Ext. PWM Dimming
1000:1 dimming ratio with external PWM
Remote ON / OFF
Wide Input Voltage Range
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-20°C ~ +70°C
-20°C ~ +85°C
95 %RH max
64 x 32 x 10.5 mm
Weight :5 (g) typ.
Tolerance: ±0.3mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0890
Note
t=1.0m m
Molex
3
Connector CN2
1
53261-0590
Molex
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.387, 21st May 2010
LED-CONVERTER UNIT
PS-LD0101-x-yyy(S) (9 W)
(PRELIMINARY INFORMATION)
Output side CN2
Input side CN1:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
CN 1-5
CN 1-6
CN 1-7
Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
Vin
10.8 ~ 13.2 Vdc
Vrm t
0 ~ 0.8 = OFF / 2.5 ~ 5.0 = ON
Ext. PWM 0 ~ 0.5 = LOW / 2.5 ~ 5 = HIGH
Vbr
0.0 ~ 5.0 (5V=low brightnes s )
GND
GND
GND
CN 1-8
JP 1
JP 2
Symbols
Ratings
RTN1 (-) LED STRING 1 RETURN
RTN1 (-) LED STRING 1 RETURN
NC
Vhigh (+)
35 Vdc
CN 2-5
Vhigh (+)
35 Vdc
-
Output Current Select Control
Jumper
Break
Break
Break
Break
Break
Pin No.
CN 2-1
CN 2-2
CN 2-3
CN 2-4
JP 3
JP 4
JP 5
Output Current
+10 mA
+20 mA
+40 mA
+80 mA
+120 mA
Example:
30mA (Output Current Min.) + 10mA (JP1) = 40mA
30mA (Output Current Min.) + 80mA (JP4) = 110mA
JP1 ~ JP5 OPEN = 300mA
For more information, please visit our web-site.
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Open Load Shutdow n
Output Pow er
Iout
Im in
Iin
Vbias
Pout
Note 1 :
Note 2 :
Note 3:
Note 4 :
Note 5 :
Vin (V)
10.8
10.8
10.8
10.8
10.8
~ 13.2
~ 13.2
~ 13.2
~ 13.2
~ 13.2
Specification
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
0
5
0
0
0
-20~+70
-20~+70
-20~+70
-20~+70
-20~+70
TBD
0.03
TBD
30
25
35
9
TBD
0.5
TBD
Unit
Note
m Adc
%
Adc
Vdc
Watt
Dut y 100 %
d ut y cycle
Do not use analog dimming function and external PWM for dimming at the same time.
Pin terminal style converters have Molex connectors mounted.
Above output current is the default value. Correct output current is to be selected by user and under
his sole responsibility. Exceeding currents will damage the LED backlight.
External PWM-signal is LOW active.
If using external PWM for dimming, please connect Pin CN1-5 to GND.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.387, 21st May 2010
LED-CONVERTER UNIT
PS-LD0101-x-yyy(S) (9 W)
(PRELIMINARY INFORMATION)
TEST CIRCUIT :
ORDER KEY :
PS-LD0101-x-yyy
With order of this converter please give the following key:
-x to be replaced by:
-1 for connectors
-2 for Pin-Terminal
in case of quantity orders (300+ pcs), the proper current selection can be ordered:
-yyy to be replaced by:
three digit value for output current per LED line (from 030 to 300 including)
Attention: * if no value is mentioned, 30 mA output current per LED line will be set as default
* a selection of incorrect LED current may decrease lifetime or destroy the backlight
* orders for preconfigured converters can’t be cancelled
Examples:
PS-LD0101-1-040 (S)
40 mA output current
PCB with connectors
PS-LD0101-2-150 (S)
150 mA output current
PCB with Pin-Terminal
CABLES :
for input: 500 mm, stripped and tinned ends, order key <input cable #13>
for output: 500 mm, stripped and tinned ends, order key <input cable #5>
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (3)