DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-DA0137-138-E-B (S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for single lamp.
Optimized for Sharp: LQ075V3DG01
APPLICABLE LCD:
Lamp Voltage 890 Vrms
Lamp Current 6.0 mArms
Lamp Start Up Voltage 2.400 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Current balance circuit
Extra high starting Voltage
RoHS compliant (S)
Voltage Dimming
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
L x B x H 100 x 30 x 9 mm
SM02(8.0)B-BHS-1-TB (JST)
DIMENSIONS :
-30°C ~ +80°C
-35°C ~ +85°C
95 %RH max
Unit : mm
Weight :15 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Discription
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0690
Note
t=1m m
Molex or equal
3
Connector CN2
1
SM02(8.0)B-BHS-1-TB
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.0.2, 30th September 2010
DC-AC INVERTER UNIT
PS-DA0137-138-E-B (S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
Input side CN1:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
CN 1-5
Output side CN2
Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
Vin
10.8 ~ 13.2 Vdc
Vrm t
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
Vbr
0 ~ 5.0 Vdc
GND
GND
CN 1-6
Pin No.
CN 2-1
CN 2-2
Symbols
Vhigh
N.C.
Ratings
890 Vrm s (6.0 m Arm s )
-
CN 2-3
Vlow
(GND)
-
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shotdow n
Iout
Iout
Iin
F
Vopen
Ts d
Note 1 :
Note 2:
Vin (V)
Vbr (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0
5.0
0.0
0.0
0.0
0.0
Specification
Tu (°C)
-30
-30
-30
-30
-30
-30
~ +80
~ +80
~ +80
~ +80
~ +80
~ +80
Min.
Typ.
Max.
5.5
50
2.200
-
6.0
15
0.6
60
2.400
1.0
6.5
0.7
70
2.700
-
Unit
Note
m Arm s
%
Adc
kHz
Vrm s
s ec
Dut y 10 0 %
wit hout lo ad
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Open circuit on all lamps for more than 1 sec., will shut the inverter down.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 2.0.2, 30th September 2010