POWER-SYSTEMS PS-DA0408-092-B

DC-AC INVERTER UNIT
PS-DA0408-092-B(S) (18 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for quad lamps.
Optimized and for Sharp: LQ150X1LGB1
APPLICABLE LCD:
15 to 19 inches quad lamp type
Lamp Voltage 625 Vrms
Lamp Current 4 x 6 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Independent Open Lamp Detection for each side
Current balance circuit
Dimming Function
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +60°C
-20°C ~ +85°C
95 %RH max
160 x 26 x 12.6 mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 ~ CN5
Qty.
1
1
4
Material
UL94V-0 (FR-4 or CEM-3)
53261-1290
SM02B-BHSS-1-TB
Unit : mm Weight :45 (g) typ.
Note
t=1m m
Molex or equal
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.2, 22th October 2007
DC-AC INVERTER UNIT
PS-DA0408-092-B(S) (18 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
Output side CN2 ~ CN5
Input side CN1:
Pin No.
CN 1-1;3;5;6;8;9
CN 1-2
Symbols
GND
Vbr
CN 1-4
Vrm t
CN 1-7
CN 1-10;11;12
N.C.
Vin
Pin No.
CN 2-1
CN 2-2
Ratings
0 ~ 5.0 Vdc
0 ~ 0.5 = OFF
/ 3.3 ~ Vin = ON
Symbols
Vhigh
Vlow
Ratings
625 Vrm s (6.0 m Arm s )
(GND)
10.8 ~ 13.2 Vdc
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Vin (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
Specification
Vbr (V) Tu (°C)
0
5
0
0
0
0
0
0
0
0
~ +60
~ +60
~ +60
~ +60
~ +60
Min.
Typ.
Max.
5.5
45
1.600
6.0
26
1.46
50
1.800
6.5
1.89
55
2.300
Unit
Note
m Arm s
%
Adc
kHz
Vrm s
mo st b rig ht ness
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.2, 22th October 2007