Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
July 17, 2013
Revision 5.0
NEC Corporation
CONFIGURATION GUIDE – NEC Express5800/R110e-1E
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 7
Front and Rear Views ........................................................................................................................... 7
Dimensions (mm) .................................................................................................................................. 8
CONFIGURATION DIAGRAM ......................................................................................... 9
EXPANSION SLOTS ..................................................................................................... 10
SERVER CONFIGURATION ......................................................................................... 11
1
2
3
4
5
6
7
8
Base Models ................................................................................................................................. 11
Processor ..................................................................................................................................... 11
Memory ......................................................................................................................................... 11
Internal Hard Disk Drives ............................................................................................................ 13
4.1 RAID Configuration .............................................................................................................. 13
4.2 2.5-inch Drive Configuration ................................................................................................ 15
4.3 3.5-inch Drive Configuration ................................................................................................ 21
Optical Drive ................................................................................................................................. 24
PCI Card ........................................................................................................................................ 24
6.1 Network Interface Controller ................................................................................................ 25
6.2 External Storage Controller ................................................................................................. 26
6.3 Serial Port Adapter .............................................................................................................. 26
Other Add-in Components .......................................................................................................... 27
7.1 Internal Flash Memory ......................................................................................................... 27
7.2 Flash FDD............................................................................................................................ 27
7.3 Front Bezel .......................................................................................................................... 27
Add-on Components ................................................................................................................... 28
8.1 17-inch LCD Console Drawer .............................................................................................. 28
8.2 KVM Switch ......................................................................................................................... 28
8.3 Server Management License............................................................................................... 29
REFERENCES............................................................................................................... 30
Server Management ............................................................................................................................ 30
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 31
Supported PCI cards and Installable Slots....................................................................................... 31
Copyright Notice and Liability Disclaimer ........................................................................................ 33
REVISION HISTORY ..................................................................................................... 34
NEC Corporation
Revision 5.0 – July 17, 2013
2
CONFIGURATION GUIDE – NEC Express5800/R110e-1E
Technical Specification
Key Features




High performance with the latest Intel® Xeon® processor E3-1200v2 series
Up to 32 GB of high speed DDR3-1600 memory
High energy efficiency with intelligent fan control, power capping feature and 80 PLUS® Gold power
supply
Full manageability by integrated EXPRESSSCOPE Engine 3
Specification
2.5-inch Drive Model
Model
R110e-1E
Part Number
Processor
N8100-1933F
Type
Intel® Pentium®
Processor G2020
Intel® Xeon®
Processor
E3-1220v2
Intel® Xeon®
Processor
E3-1270v2
Clock speed
2.90 GHz
3.10 GHz
3.50 GHz
Number of Processor
1
Cache
3 MB
8 MB
Cores and Threads
2C / 2T
4C / 4T
Chipset
Memory
Internal Storage
Intel® C204 Chipset
Type
DDR3-1600 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
32 GB (4 x 8 GB)
Standard Capacity
0 GB
Maximum Capacity
SATA HDD: 6 TB (6 x 1 TB)
SAS HDD : 7.2 TB (6 x 1.2 TB)
SAS SSD 2.4 TB (6 x 400 GB)
Disk Controller
SATA : 6 Gb/s and/or 3 Gb/s (Integrated)
SAS : 6 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard ), RAID 5/6/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
6
1
Expansion Slots
Video
Interfaces
NEC Corporation
4C / 8T
Total: 2 slots available
2
1 PCIe 3.0 or 2.0 x8 (x16 connector)
2
1 PCIe 3.0 or 2.0 x8 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1280 x 1024 / 16.7M
3
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
8 USB2.0 (2 front, 4 rear, 2 internal)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 100BASE-TX LAN connector for Management (RJ-45, 1 rear)
Revision 5.0 – July 17, 2013
3
CONFIGURATION GUIDE – NEC Express5800/R110e-1E
Model
R110e-1E
Server Management
EXPRESSSCOPE Engine 3
System Fan
Standard
Power Supply
1 400 Watt 80 PLUS® Gold certified non-Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
(Max. Config, Idling)
93 VA / 90 Watt
90 VA / 89 Watt
96 VA / 93 Watt
126 VA / 124 Watt
235 VA / 230 Watt
268 VA / 265 Watt
Acoustic Noise
(Sound Pressure
Maximum Config.
4
Level)
Dimensions (W x D x H )
39.4 dB
50.7 dB
42.2 dB
50.7 dB
Weight (Minimum / Maximum)
10 kg / 18 kg, 22.05 lbs. / 39.68 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2003 R2, Standard Edition SP2 or later
Microsoft® Windows Server® 2003 R2, Enterprise Edition SP2 or later
Microsoft® Windows Server® 2003 R2, Standard x64 Edition
Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
6
Microsoft® Windows Server® 2012 Standard
6
Microsoft® Windows Server® 2012 Datacenter
7
Red Hat Enterprise Linux 5.8 or later
7
Red Hat Enterprise Linux 5.8 or later (EM64T)
7
Red Hat Enterprise Linux 6.2 or later (x86)
7
Red Hat Enterprise Linux 6.2 or later (x86_64)
8
VMware ESXi 5.0 update 1
7
VMware ESXi 5.1
(Max. Config,
Operating)
Minimum Config.
1
2
3
4
5
6
7
8
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
5
5
Embedded SATA RAID controller is supported only on Windows operating systems.
The PCIe slot works at PCIe 2.0 speeds on Pentium processor systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the
operating environment.
Operable up to 35°C (95°F) when five or more hard drives are installed.
For Windows Server 2012 installation, download the driver kit from the following website and install it
after OS installation
http://www.nec.com/en/global/prod/express/download/
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
VMware ESXi 5.0 and 5.1 are supported only on Xeon processor systems.
NEC Corporation
Revision 5.0 – July 17, 2013
4
CONFIGURATION GUIDE – NEC Express5800/R110e-1E
3.5-inch Drive Model
Model
R110e-1E
Part Number
N8100-1932F
Processor
Type
Intel®
Pentium®
Processor
G2020
Intel®
Xeon®
Processor
E3-1220Lv2
Intel®
Xeon®
Processor
E3-1220v2
Intel®
Xeon®
Processor
E3-1265Lv2
Intel®
Xeon®
Processor
E3-1270v2
Clock Speed
2.90 GHz
2.30 GHz
3.10 GHz
2.50 GHz
3.50 GHz
Number of Processor
1
Cache
3 MB
Cores and Threads
2C / 2T
Chipset
Memory
Internal Storage
2C / 4T
4C / 4T
4C / 8T
Intel® C204 Chipset
Type
DDR3-1600 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
32 GB (4 x 8 GB)
Standard Capacity
0 GB
Maximum Capacity
SATA : 16 TB (4 x 4 TB)
Disk Controller
SATA : 6Gb/s and/or 3 Gb/s (Integrated)
RAID
SATA : RAID 0/1/10 (Standard ), RAID 5/6 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
1
Expansion Slots
Video
8 MB
Total: 2 slots available
2
1 PCIe 3.0 or 2.0 x8 (x16 connector)
2
1 PCIe 3.0 or 2.0 x8 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1280 x 1024 / 16.7M
3
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
8 USB2.0 (2 front, 4 rear, 2 internal)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 100BASE-TX LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
System Fan
Standard
Power Supply
1 400 Watt 80 PLUS® Gold certified non-Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
(Max. Config, Idling)
91 VA /
88 Watt
97VA /
94 Watt
100VA /
99 Watt
94VA /
91 Watt
96VA /
93 Watt
(Max. Config,
Operating)
122 VA /
119 Watt
175 VA /
172 Watt
234 VA /
231 Watt
197 VA /
194 Watt
266 VA /
264 Watt
Acoustic Noise
Minimum Config.
(Sound Pressure
Maximum Config.
4
Level)
Dimensions (W x D x H )
39.4 dB
32.9 dB
50.7dB
32.9 dB
50.7 dB
50.7dB
42.2 dB
50.7 dB
Weight (Minimum / Maximum)
10 kg / 18 kg, 22.05 lbs. / 39.68 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
NEC Corporation
42.2 dB
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
5
Revision 5.0 – July 17, 2013
5
5
CONFIGURATION GUIDE – NEC Express5800/R110e-1E
Model
R110e-1E
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2003 R2, Standard Edition SP2 or later
Microsoft® Windows Server® 2003 R2, Enterprise Edition SP2 or later
Microsoft® Windows Server® 2003 R2, Standard x64 Edition
Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
6
Microsoft® Windows Server® 2012 Standard
6
Microsoft® Windows Server® 2012 Datacenter
7
Red Hat Enterprise Linux 5.8 or later
7
Red Hat Enterprise Linux 5.8 or later (EM64T)
7
Red Hat Enterprise Linux 6.2 or later (x86)
7
Red Hat Enterprise Linux 6.2 or later (x86_64)
8
VMware ESXi 5.0 update 1
7
VMware ESXi 5.1
1
2
3
4
5
6
7
8
Embedded SATA RAID controller is supported only on Windows operating systems.
The PCIe slot works at PCIe 2.0 speeds on Pentium processor systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the
operating environment.
Operable up to 35°C (95°F) when four hard drives are installed.
For Windows Server 2012 installation, download the driver kit from the following website and install it
after OS installation
http://www.nec.com/en/global/prod/express/download/
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
VMware ESXi 5.0 and 5.1 are supported only on Xeon processor systems.
NEC Corporation
Revision 5.0 – July 17, 2013
6
External Views
Front and Rear Views
Front View for 2.5-inch Drive Model
D F H
E
G
J
L
I
M
N
K
C
B
A
Front View for 3.5-inch Drive Model
D F H
E
G
J
I
L
M
N
K
B
C
A
Legend
A.
Drive Bays
H.
UID LED
B.
Optical Drive Bay
I.
System Status LED
C.
USB Connectors
J.
BMC Reset Switch
D.
Power LED
K.
Dump (NMI) Switch
E.
Hard Drive Activity LED
L.
UID LED Button
F.
Data LAN 1 Activity LED
M.
Power Button
G.
Data LAN 2 Activity LED
N.
Pull-out Tab
NEC Corporation
Revision 5.0 – July 17, 2013
7
Rear View
K
L
I
J
C
H
D
F
E
A
B
G
Legend
A.
PCI Slot (Low profile)
G.
UID LED / Button
B.
PCI Slot (Low profile)
H.
Power LED
C.
Data LAN 1 Connector
I.
Serial Port Connector
D.
Data LAN 2 Connector
J.
VGA Connector
E.
Management LAN Connector
K.
Power Unit
USB Connectors
L.
AC Inlet
F.
Dimensions (mm)
NEC Corporation
Revision 5.0 – July 17, 2013
8
Configuration Diagram
2.5-inch Drive Model
2.5-inch
Drive Cage
Processor
1 DIMM
4 DIMMs
Power
Supply
Legend:
PCI 1
2 BBU slots
PCIe 3.0 or 2.0
Cooing Fan
6 Drive Bays
Media Bay
CHASSIS
REAR
PCI 2
CHASSIS
INSIDE
Media Bay
CHASSIS
FRONT
Minimum requirement components
Power
Supply
Standard components
3.5-inch Drive Model
CHASSIS
REAR
Processor
1 DIMM
4 DIMMs
Media Bay
Power
Supply
Legend:
NEC Corporation
Cooing Fan
Media Bay
4 Drive Bays
3.5-inch
Drive Cage
PCIe 3.0 or 2.0
PCI 1
PCI 2
CHASSIS
INSIDE
2 BBU slots
CHASSIS
FRONT
Minimum requirement components
Revision 5.0 – July 17, 2013
Power
Supply
Standard components
9
Expansion Slots
#1
#2
Legend
#1
PCIe 3.0 or 2.0 x8, x16 connector, Low profile, up to 200 mm length
#2
PCIe 3.0 or 2.0 x8, x8 connector, Low profile, up to 200 mm length
NOTE:

The slots work at PCIe 3.0 speeds on Xeon processor systems.
NEC Corporation
Revision 5.0 – July 17, 2013
10
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800/R110e-1E
No CPU, no RAM, no 2.5-inch HDD, no Front bezel
Including:
2.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD
NEC Express5800/R110e-1E
No CPU, no RAM, no 3.5-inch HDD, no Front bezel
Including:
3.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD
N8100-1933F
N8100-1932F
NOTE:

The base model must be ordered with a processor kit.
2 Processor
Available sockets: 1
Category
Product Name / Description
Part Number
Processors
Required
Processor Kit (2C/G2020)
Intel® Pentium ® Processor G2020 (2.90 GHz, 2C/2T, 3 MB)
Processor Kit (2C/E3-1220Lv2)
Intel® Xeon ® Processor E3-1220Lv2 (2.30 GHz, 2C/4T, 3 MB)
NOTE: The kit is supported only on 3.5-inch drive model.
Processor Kit (4C/E3-1220v2)
Intel® Xeon ® Processor E3-1220v2 (3.10 GHz, 4C/4T, 8 MB)
Processor Kit (4C/E3-1265Lv2)
Intel® Xeon ® Processor E3-1265Lv2 (2.50 GHz, 4C/8T, 8 MB)
NOTE: The kit is supported only on 3.5-inch drive model.
Processor Kit (4C/E3-1270v2)
Intel® Xeon ® Processor E3-1270v2 (3.50 GHz, 4C/8T, 8 MB)
N8101-638F
N8101-589F
N8101-590F
N8101-591F
N8101-592F
NOTE:

The processor kit must be ordered with the base model.
3 Memory
Available slots: 4
Product Name / Description
Part Number
2GB DDR3-1600 UNB Memory Kit
2GB Unbuffered ECC DIMM, DDR3-1600(PC3-12800)
4GB DDR3-1600 UNB Memory Kit
4GB Unbuffered ECC DIMM, DDR3-1600(PC3-12800)
8GB DDR3-1600 UNB Memory Kit
8GB Unbuffered ECC DIMM, DDR3-1600(PC3-12800)
N8102-501F
N8102-502F
N8102-503F
NOTE:



Minimum one memory kit must be installed.
To install by double of memory kit is recommended in order to increase memory transfer
speed by the dual-channel symmetric configuration.
Actual memory speed drops to 1066 MHz when you choose Pentium Processor.
NEC Corporation
Revision 5.0 – July 17, 2013
11
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system
because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary
depending on the type and the number of PCI cards you are using.
Maximum Memory Size Supported by Operating Systems
Microsoft Windows Server 2003 R2, Standard Edition
Microsoft Windows Server 2008 Standard
4 GB
4 GB( HW-DEP enabled)
App. 3.5 GB (HW-DEP disabled)
Microsoft Windows Server 2003 R2, Standard x64 Edition
Microsoft Windows Server 2008 Standard (x64)
Microsoft Windows Server 2008 R2 Standard
32 GB
32 GB
Microsoft Windows Server 2003 R2, Enterprise Edition
Microsoft Windows Server 2008 Enterprise
64 GB
32 GB
Microsoft Windows Server 2003 R2, Enterprise x64 Edition
1 TB
32 GB
Microsoft Windows Server 2008 Enterprise (x64)
Microsoft Windows Server 2008 R2 Enterprise
2 TB
32 GB
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
4 TB
32 GB
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 6
16 GB
16 GB
Red Hat Enterprise Linux 5 (EM64T)
1 TB
32 GB
Red Hat Enterprise Linux 6 (x86_64)
2 TB
32 GB
2 TB
32 GB
VMware ESXi 5.0, 5.1
1
Maximum Available Memory
1
Up to 1 TB of the main memory is available to each virtual machine.
NEC Corporation
Revision 5.0 – July 17, 2013
12
4 Internal Hard Disk Drives
4.1
RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration.
4.1.1
2.5-inch Drive
Available Interface
Non-RAID
Refer to 4.2.1
SATA
Refer to 4.2.2
SATA
128 MB Cache
Refer to 4.2.3
SAS, SATA
512 MB Cache
Refer to 4.2.4
SAS, SATA
512 MB Cache
Refer to 4.2.5
SAS, SATA
1GB Cache/
Battery
Refer to 4.2.6
SAS, SATA
1GB Cache/
CacheCade
Refer to 4.2.7
SAS, SATA
Embedded SATA
RAID Controller
RAID 0/1/10
Optional RAID
Controller
RAID 5/6
NOTE:






The RAID controller with 1GB Cache / CacheVault does not support on Pentium G2020 processor
systems.
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller.
All drives within a RAID array should be of the same type, capacity and rotation speed.
All SAS hard drives within a system should be of the same rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
NEC Corporation
Revision 5.0 – July 17, 2013
13
4.1.2
3.5-inch Drive
Available Interface
Non-RAID
Refer to 4.3.1
SATA
Refer to 4.3.2
SATA
128 MB Cache
Refer to 4.3.3
SATA
512 MB Cache
Refer to 4.3.4
SATA
512 MB Cache
Refer to 4.3.5
SATA
1GB Cache/
Battery
Refer to 4.3.6
SATA
1GB Cache/
CacheVault
Refer to 4.3.7
SATA
Embedded SATA
RAID Controller
RAID 0/1/10
Optional RAID
Controller
RAID 5/6
NOTE:



Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller.
All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 5.0 – July 17, 2013
14
4.2
2.5-inch Drive Configuration
4.2.1
Embedded SATA non-RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
2x 6Gb/s SATA, 2x 3Gb/s SATA
Internal SATA Cable
4x Single-SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
(Standard)
Cable
Drive Cage
Drive
4 slots
available
SATA
HDD
(Standard)
(Standard)
N8150-356
N8150-357
N8150-358
NOTE:

Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller.
4.2.2
Embedded SATA RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
2x 6Gb/s SATA, 2x 3Gb/s SATA, RAID 0/1/10 capable
Internal SATA Cable
4x Single-SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
(Standard)
Cable
Drive Cage
Drive
4 slots
available
SATA
HDD
(Standard)
(Standard)
N8150-356
N8150-357
N8150-358
NOTE

Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
NEC Corporation
Revision 5.0 – July 17, 2013
15
4.2.3
RAID 0/1 Controller with 128 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (128MB, RAID 0/1)
Promise SuperTrak TX8760T-128
RAID 0/1/10, 128MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
3Gb/s
RAID Battery Backup Unit
for Promise SuperTrak TX8760T
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
Internal SAS Cable
1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives
NOTE: To install five drives or more, the cable is required.
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8103-128
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
73.2GB 15K Hot Plug 2.5-inch SAS HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-322
RAID BBU
Recommended
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-140
K410-240(00)
K410-204(00)
(Standard)
N8150-301
N8150-304
N8150-332
N8150-408
N8150-302
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 5.0 – July 17, 2013
16
4.2.4
RAID 0/1 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID 0/1/10, 512MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
Internal SAS Cable
1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives
NOTE: To install five drives or more, the cable is required.
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
73.2GB 15K Hot Plug 2.5-inch SAS HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8103-149
RAID BBU
Recommended
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
K410-240(00)
K410-204(00)
(Standard)
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-302
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 5.0 – July 17, 2013
17
4.2.5
RAID 5/6 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
Internal SAS Cable
1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8103-150
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
73.2GB 15K Hot Plug 2.5-inch SAS HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-322
RAID BBU
Recommended
Cable
Required
Cable
Drive Cage
Drive
6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
K410-240(00)
K410-204(00)
(Standard)
N8150-301
N8150-304
N8150-332
N8150-408
N8150-302
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 5.0 – July 17, 2013
18
4.2.6
RAID 5/6 Controller with 1 GB Cache/Battery
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-151
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
Internal SAS Cable
1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives
NOTE: To install five drives or more, the cable is required.
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
73.2GB 15K Hot Plug 2.5-inch SAS HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
K410-240(00)
RAID BBU
Recommended
SSD Caching
Recommended
Cable
Required
Cable
Drive Cage
Drive
6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
N8103-156
K410-204(00)
(Standard)
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-302
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 5.0 – July 17, 2013
19
4.2.7
RAID 5/6 Controller with 1 GB Cache/CacheVault
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i(with CV)
RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8),
6Gb/s, flash cache protection modules included
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-152
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
Internal SAS Cable
1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug hard drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
73.2GB 15K Hot Plug 2.5-inch SAS HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
K410-240(00)
SSD Caching
Recommended
Cable
Required
Cable
Drive Cage
Drive
6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-156
K410-204(00)
(Standard)
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-302
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

The RAID configuration does not support on Pentium G2020 Processor systems.

All drives within a RAID array should be of the same type, capacity and rotation speed.

For VMware ESXi 5.x installation, to download the CIM provider is required.

For VMware ESXi 5.x systems, monitoring the status of a RAID array with NEC ESMPRO is not
supported.
NEC Corporation
Revision 5.0 – July 17, 2013
20
4.3
3.5-inch Drive Configuration
4.3.1
Embedded SATA non-RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
2x 6Gb/s SATA, 2x 3Gb/s SATA
Internal SATA Cable
(Standard)
Cable
(Standard)
4x Single-SATA
Drive Cage
Drive
4 slots available
3.5-inch Drive Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
(Standard)
N8150-363
N8150-364
N8150-354
NOTE

Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.2
Embedded SATA RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
2x 6Gb/s SATA, 2x 3Gb/s SATA, RAID 0/1/10 capable
Internal SATA Cable
(Standard)
Cable
(Standard)
4x Single-SATA
HDD Cage
Drive
4 slots available
3.5-inch Drive Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.

Embedded SATA RAID Controller does not support RAID 10 configured with 2TB and 3TB HDDs.

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 5.0 – July 17, 2013
21
4.3.3
RAID 0/1 Controller with 128 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (128MB, RAID 0/1)
Promise SuperTrak TX8760T-128
RAID 0/1/10, 128MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
3Gb/s
RAID Battery Backup Unit
for Promise SuperTrak EX8760T
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
3.5-inch HDD Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-128
RAID BBU
Recommended
Cable
Required
HDD Cage
Drive
4 slots available
N8103-140
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
NOTE:

All hard drives within a RAID array should be of the same capacity.
4.3.4
RAID 0/1 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID 0/1, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
3.5-inch HDD Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-149
RAID BBU
Recommended
Cable
Required
HDD Cage
Drive
4 slots available
N8103-154
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 5.0 – July 17, 2013
22
4.3.5
RAID 5/6 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
3.5-inch HDD Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-150
RAID BBU
Recommended
Cable
Required
HDD Cage
Drive
4 slots available
N8103-154
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
4.3.6
RAID 5/6 Controller with 1 GB Cache/Battery
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
3.5-inch HDD Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-151
RAID BBU
Recommended
Cable
Required
HDD Cage
Drive
4 slots available
N8103-154
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 5.0 – July 17, 2013
23
4.3.7
RAID 5/6 Controller with 1 GB Cache/CacheVault
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60,
1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache
protection modules included
Internal SAS Cable
1x Mini-SAS - 4x Single SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug hard drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-152
Cable
Required
Drive Cage
Drive
4 slots available
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.

For VMware ESXi 5.x installation, to download the CIM provider is required.

For VMware ESXi 5.x systems, monitoring the status of a RAID array with NEC ESMPRO is not
supported.
5 Optical Drive
Category
Product Name / Description
Part Number
Internal
1 slot available
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
External DVD-ROM drive
DVD-ROM drive, Bus powered, 1.2 A required
N8151-100
External
N8151-107F
N8160-91
NOTE:

Up to 1 optical drive can be connected.
NEC Corporation
Revision 5.0 – July 17, 2013
24
6 PCI Card
Please refer to
NEC Corporation
Revision 5.0 – July 17, 2013
25
Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI
card supported.
6.1
Network Interface Controller
Category
Adapter
GbE
10GbE
SPF+
Module
Product Name / Description
Part Number
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
10GBASE Adapter (SFP+/2ch)
Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port
Network Interface Card
PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical
cable.
- Up to 2 SFP+ Modules can be installed.
- Up to 1 adapter is supported when RHEL6 is installed.
- Supports up to 2 adapters covering 10Gb Converged Network
Adapter and 10Gb Network Adapter.
N8104-138
Dual Port 10Gb Converged Network Adapter
BROCADE 1020 Dual Port 10Gbps Converged Network Adapter
PCIe 2.0 x8, 2 x SFP modules, Max. one adapter
NOTE:
- Supports up to two adapters of10Gb Converged Network
Adapter and 10Gb Network Adapter.
N8104-131
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-128
N8104-129
N8104-132
N8104-128
NIC Teaming feature - NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2003 R2 and Windows Server 2008 support BASP (Broadcom Advanced Server
Program) teaming while Windows Server 2012 and Linux support teaming with bonding function supported
by OS.
Network Interface
Team
Operating Systems
1GbE NIC
Embedded 1GbE NIC and N8104-138/-132
Up to four teams per one system
Up to four ports per one team
Windows Server 2003 R2
Windows Server 2008
Windows Server 2008 R2
Windows Server 2012
Red Hat Enterprise Linux
10GbE NIC
N8104-128
Up to two teams per one system
Up to two ports per one team
Windows Server 2008
Windows Server 2008 R2
Windows Server 2012
Red Hat Enterprise Linux
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.

The network interfaces for teaming must be the same.

When 10GbE and 1GbE NIC teaming are mixed, the teams must be up to four per one system.
NEC Corporation
Revision 5.0 – July 17, 2013
26
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Categor
Network Interface
Operating Systems
1GbE
Embedded 1GbE NIC
Windows Server 2008 R2, Windows Server 2012, Red Hat Linux, VMware
N8104-138
Windows Server 2008 R2, Windows Server 2012, Red Hat Linux, VMware
N8104-132
Windows Server 2008 R2, Windows Server 2012, Red Hat Linux, VMware
N8104-128
Windows Server 2008, Windows Server 2008 R2, Red Hat Linux, VMware
y
10GbE
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.
6.2
External Storage Controller
6.2.1
RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9285-8e
RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9285-8e
N8103-160
RAID BBU
N8103-162
NOTE:

To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.

It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
6.2.2
Fibre Channel / SAS Controller
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (1ch)
Emulex LightPulse LPe16000B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
NOTE:
The controller does not support on Pentium G2020 Processor
systems.
Fibre Channel Controller (2ch)
Emulex LightPulse LPe16002B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
NOTE:
The controller does not support on Pentium G2020 Processor
systems.
N8190-153
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
N8103-142
SAS
NEC Corporation
Revision 5.0 – July 17, 2013
N8190-154
N8190-157
N8190-158
27
6.3
Serial Port Adapter
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
N8117-01A
NOTE:

Up to one Serial Port Adapter can be installed.
7 Other Add-in Components
7.1
Internal Flash Memory
Available socket: 1
Product Name / Description
Part Number
Internal Flash Memory
Internal flash memory to enable software and tools in the EXPRESSBUILDER DVD
without DVD media
NOTE:
Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the
flash memory.
The following operations can be performed with the flash memory:
- Installation of Windows server with express setup
- Installation of Starter Pack—the package of NEC qualified drivers and system setting
tools
- Installation of NEC ESMPRO Agent and Universal RAID Utility
- Performance of the Test and Diagnosis Tool
N8115-05
7.2
Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
NOTE:

Up to one drive can be connected.
7.3
Front Bezel
Product Name / Description
Part Number
Front Bezel
Front bezel for R110d-1E
N8146-37F
NEC Corporation
Revision 5.0 – July 17, 2013
28
8 Add-on Components
8.1
17-inch LCD Console Drawer
Category
Drawer
Drawer
w/ KVM
Cable
Drawer
Drawer
w/o KVM
Keypad
8.2
Product Name / Description
Part Number
17-inch LCD Console Drawer (8 port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port
KVM switch, 1U height
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1 port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad
with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8
m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD
Console Drawer (1 port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD
Console Drawer (1 port)
N8143-77F
K410-118(1A)
K410-118(03)
K410-118(05)
N8143-76F
N8143-84F
N8143-85
N8143-87
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
N8191-12F
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-118(1A)
Cable
KVM
Cascading
NEC Corporation
Revision 5.0 – July 17, 2013
K410-118(03)
K410-118(05)
K410-119(1A)
29
8.3
Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
Product Name / Description
Part Number
Remote KVM and Media License kit
N8115-04
License for one server.
Remote console and remote media are enabled regardless of OS status.
Remote KVM:
Displays a graphics console on the web browser of the remote terminal
(PC/server).
Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
NOTE:

Remote KVM and remote media features are not available for virtual machines.
NEC Corporation
Revision 5.0 – July 17, 2013
30
References
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
3
4


Hardware configuration information collection


Hardware event log collection


2
2
BIOS/POST stall, Booting, OS stall, shutdown

Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)

Remote KVM
(via LAN)
POST/BIOS setup, ROM utility

1

Panic screen, Boot screen

1,3

CUI-based screen (OS console)

1,4

GUI-based screen (OS console)
-

Remote reset/power on-off/ dump


Remote Power Capping


BIOS/BMC FW update


Remote BIOS setup(partial configuration only)


OS shutdown

Remote media (CD/DVD/FD/USB)
-

CLP (Command Line Protocol) (DMTF compliant)


Remote control via Web browser (multi user login
at the same time)


Scheduling (without UPS)

Maintenance
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)


Others
Set automatic IP address via DNS/DHCP


LDAP/Active Directory verification/user control


Clock synchronization of main unit and the RTC


Access log collection


IPMI support
2.0
2.0
Industry
Standard
2
Temperature/fan/voltage/power
consumption/degeneration(memory)
Boot monitoring
Remote control
(via LAN)
1
With Remote KVM
and Media License
kit
2
2




2
2
The optional serial port is not available for the feature
The feature is not supported on VMware systems
Monitoring boot screens is not supported on VMware systems.
In VMware systems, only the direct console user interface is supported.
NEC Corporation
Revision 5.0 – July 17, 2013
31
OS Support Matrix for PCI Cards and Embedded Controllers
ESXi 5.0
ESXi 5.1
RHEL 5 x64
RHEL 5
RHEL 6 x64
RHEL 6
WS 2003R2 x64
WS 2003R2
WS 2008 x64
WS 2008
WS 2008R2
WS 2012
Part Number
Product Name
-
Embedded SATA non-RAID Controller

-
Embedded SATA RAID Controller
-
-
Embedded 1GbE NIC

N8103-142
SAS controller

N8103-128
RAID controller (128MB, RAID 0/1)
 -
N8103-149
RAID controller (512MB, RAID 0/1)

N8103-150
RAID controller (512MB, RAID 0/1/5/6)

N8103-151
RAID controller (1GB, RAID 0/1/5/6)

N8103-152
RAID controller (1GB, RAID 0/1/5/6)
 -
N8103-160
RAID controller (1GB, RAID 0/1/5/6)

N8190-153
Fibre Channel Controller

N8190-154
Fibre Channel Controller (2ch)

N8190-157
Fibre Channel Controller
 -
-
-
-
-
 -
-
-
-
N8190-158
Fibre Channel Controller (2ch)
 -
-
-
-
-
 -
-
-
-
N8104-138
1000BASE-T adapter (1ch)

N8104-132
1000BASE-T adapter (2ch)

N8104-128
10GBASE Adapter (SFP+/2ch)
 -
-

N8104-131
Dual Port 10Gb Converged Network Adapter
-
 -
-
 -
NEC Corporation
Revision 5.0 – July 17, 2013
 -
-
-
-
-
-
 -
-
-
-
-
32
Supported PCI cards and Installable Slots
Slots
Part Number
Product Name
#1
#2
N8103-142
SAS Controller


N8103-128
RAID Controller (128MB, RAID 0/1)
-

N8103-149
RAID Controller (512MB,RAID 0/1)
-

N8103-150
RAID Controller (512MB,RAID 0/1/5/6)
-

N8103-151
RAID Controller (1GB,RAID 0/1/5/6)
-

N8103-152
RAID Controller (1GB,RAID 0/1/5/6)
-

N8103-160
RAID Controller (1GB,RAID 0/1/5/6)


N8190-153
Fibre Channel Controller


N8190-154
Fibre Channel Controller (2ch)


N8190-157
Fibre Channel Controller


N8190-158
Fibre Channel Controller (2ch)


N8104-138
1000BASE-TAdapter (1ch)


N8104-132
1000BASE-TAdapter (2ch)


N8104-128
10GBASE Adapter (SFP+/2ch)


N8104-131
Dual Port 10Gb Converged Network Adapter


N8117-01A
Serial Port Adapter


NEC Corporation
Revision 5.0 – July 17, 2013
33
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 5.0 – July 17, 2013
34
Revision History
Revision
Date
Description
5.0
July 17, 2013
New products added:
1.2TB 10K Hot Plug 2.5-inch SAS HDD / N8150-408
4.0
April 16, 2013
New products added:
Processor Kit (2C/G2020) / N8101-638F
4TB 7.2K Hot Plug 3.5-inch SATA HDD / N8150-395
Fibre Channel Controller (1ch) / N8190-157
Fibre Channel Controller (2ch) / N8190-158
Part number changed:
Internal DVD Super Multi Drive / N8151-107F
External DVD-ROM Drive / N8160-91
Discontinued products removed:
Processor Kit (2C/G640) / N8101-588F
100GB SSD / N8150-709
400GB SSD / N8150-710
Others:
Support NIC teaming on Windows Server 2012 systems.
Support N8103-142 SAS Controller on Windows Server 2012 systems
3.0
December 21, 2012
Other:
Add Windows Server 2012 to the list of operating system supported
Support N8103-152 RAID Controller on VMware ESXi 5.x systems
Support 10GbE NIC teaming with two or more 10GbE NIC cards.
Update OS support matrix
2.0
October 31, 2012
New products added:
RAID Controller (1GB, RAID 0/1/5/6) / N8103-152
200GB SSD / N8150-711
400GB SSD / N8150-712
Discontinued products removed:
100GB SSD / N8150-707
SAS Controller / N8103-104A
Other:
Add VMware ESXi 5.1 to the list of operating system supported
Support bonding feature on Linux operating system using 10GbE NIC
Update OS support matrix
1.0
July 26, 2012
Initial release
NEC Corporation
Revision 5.0 – July 17, 2013
35