NEC EXPRESS5800/R110e-1E Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. July 17, 2013 Revision 5.0 NEC Corporation CONFIGURATION GUIDE – NEC Express5800/R110e-1E Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 7 Front and Rear Views ........................................................................................................................... 7 Dimensions (mm) .................................................................................................................................. 8 CONFIGURATION DIAGRAM ......................................................................................... 9 EXPANSION SLOTS ..................................................................................................... 10 SERVER CONFIGURATION ......................................................................................... 11 1 2 3 4 5 6 7 8 Base Models ................................................................................................................................. 11 Processor ..................................................................................................................................... 11 Memory ......................................................................................................................................... 11 Internal Hard Disk Drives ............................................................................................................ 13 4.1 RAID Configuration .............................................................................................................. 13 4.2 2.5-inch Drive Configuration ................................................................................................ 15 4.3 3.5-inch Drive Configuration ................................................................................................ 21 Optical Drive ................................................................................................................................. 24 PCI Card ........................................................................................................................................ 24 6.1 Network Interface Controller ................................................................................................ 25 6.2 External Storage Controller ................................................................................................. 26 6.3 Serial Port Adapter .............................................................................................................. 26 Other Add-in Components .......................................................................................................... 27 7.1 Internal Flash Memory ......................................................................................................... 27 7.2 Flash FDD............................................................................................................................ 27 7.3 Front Bezel .......................................................................................................................... 27 Add-on Components ................................................................................................................... 28 8.1 17-inch LCD Console Drawer .............................................................................................. 28 8.2 KVM Switch ......................................................................................................................... 28 8.3 Server Management License............................................................................................... 29 REFERENCES............................................................................................................... 30 Server Management ............................................................................................................................ 30 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 31 Supported PCI cards and Installable Slots....................................................................................... 31 Copyright Notice and Liability Disclaimer ........................................................................................ 33 REVISION HISTORY ..................................................................................................... 34 NEC Corporation Revision 5.0 – July 17, 2013 2 CONFIGURATION GUIDE – NEC Express5800/R110e-1E Technical Specification Key Features High performance with the latest Intel® Xeon® processor E3-1200v2 series Up to 32 GB of high speed DDR3-1600 memory High energy efficiency with intelligent fan control, power capping feature and 80 PLUS® Gold power supply Full manageability by integrated EXPRESSSCOPE Engine 3 Specification 2.5-inch Drive Model Model R110e-1E Part Number Processor N8100-1933F Type Intel® Pentium® Processor G2020 Intel® Xeon® Processor E3-1220v2 Intel® Xeon® Processor E3-1270v2 Clock speed 2.90 GHz 3.10 GHz 3.50 GHz Number of Processor 1 Cache 3 MB 8 MB Cores and Threads 2C / 2T 4C / 4T Chipset Memory Internal Storage Intel® C204 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity SATA HDD: 6 TB (6 x 1 TB) SAS HDD : 7.2 TB (6 x 1.2 TB) SAS SSD 2.4 TB (6 x 400 GB) Disk Controller SATA : 6 Gb/s and/or 3 Gb/s (Integrated) SAS : 6 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 1 Disk Drive Bays 6 1 Expansion Slots Video Interfaces NEC Corporation 4C / 8T Total: 2 slots available 2 1 PCIe 3.0 or 2.0 x8 (x16 connector) 2 1 PCIe 3.0 or 2.0 x8 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 3 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 8 USB2.0 (2 front, 4 rear, 2 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for Management (RJ-45, 1 rear) Revision 5.0 – July 17, 2013 3 CONFIGURATION GUIDE – NEC Express5800/R110e-1E Model R110e-1E Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 400 Watt 80 PLUS® Gold certified non-Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 93 VA / 90 Watt 90 VA / 89 Watt 96 VA / 93 Watt 126 VA / 124 Watt 235 VA / 230 Watt 268 VA / 265 Watt Acoustic Noise (Sound Pressure Maximum Config. 4 Level) Dimensions (W x D x H ) 39.4 dB 50.7 dB 42.2 dB 50.7 dB Weight (Minimum / Maximum) 10 kg / 18 kg, 22.05 lbs. / 39.68 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE Operating Systems and Virtualization Software Microsoft® Windows Server® 2003 R2, Standard Edition SP2 or later Microsoft® Windows Server® 2003 R2, Enterprise Edition SP2 or later Microsoft® Windows Server® 2003 R2, Standard x64 Edition Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise 6 Microsoft® Windows Server® 2012 Standard 6 Microsoft® Windows Server® 2012 Datacenter 7 Red Hat Enterprise Linux 5.8 or later 7 Red Hat Enterprise Linux 5.8 or later (EM64T) 7 Red Hat Enterprise Linux 6.2 or later (x86) 7 Red Hat Enterprise Linux 6.2 or later (x86_64) 8 VMware ESXi 5.0 update 1 7 VMware ESXi 5.1 (Max. Config, Operating) Minimum Config. 1 2 3 4 5 6 7 8 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) 5 5 Embedded SATA RAID controller is supported only on Windows operating systems. The PCIe slot works at PCIe 2.0 speeds on Pentium processor systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. Operable up to 35°C (95°F) when five or more hard drives are installed. For Windows Server 2012 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html VMware ESXi 5.0 and 5.1 are supported only on Xeon processor systems. NEC Corporation Revision 5.0 – July 17, 2013 4 CONFIGURATION GUIDE – NEC Express5800/R110e-1E 3.5-inch Drive Model Model R110e-1E Part Number N8100-1932F Processor Type Intel® Pentium® Processor G2020 Intel® Xeon® Processor E3-1220Lv2 Intel® Xeon® Processor E3-1220v2 Intel® Xeon® Processor E3-1265Lv2 Intel® Xeon® Processor E3-1270v2 Clock Speed 2.90 GHz 2.30 GHz 3.10 GHz 2.50 GHz 3.50 GHz Number of Processor 1 Cache 3 MB Cores and Threads 2C / 2T Chipset Memory Internal Storage 2C / 4T 4C / 4T 4C / 8T Intel® C204 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity SATA : 16 TB (4 x 4 TB) Disk Controller SATA : 6Gb/s and/or 3 Gb/s (Integrated) RAID SATA : RAID 0/1/10 (Standard ), RAID 5/6 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 1 Disk Drive Bays 4 1 Expansion Slots Video 8 MB Total: 2 slots available 2 1 PCIe 3.0 or 2.0 x8 (x16 connector) 2 1 PCIe 3.0 or 2.0 x8 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 3 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 8 USB2.0 (2 front, 4 rear, 2 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 System Fan Standard Power Supply 1 400 Watt 80 PLUS® Gold certified non-Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 91 VA / 88 Watt 97VA / 94 Watt 100VA / 99 Watt 94VA / 91 Watt 96VA / 93 Watt (Max. Config, Operating) 122 VA / 119 Watt 175 VA / 172 Watt 234 VA / 231 Watt 197 VA / 194 Watt 266 VA / 264 Watt Acoustic Noise Minimum Config. (Sound Pressure Maximum Config. 4 Level) Dimensions (W x D x H ) 39.4 dB 32.9 dB 50.7dB 32.9 dB 50.7 dB 50.7dB 42.2 dB 50.7 dB Weight (Minimum / Maximum) 10 kg / 18 kg, 22.05 lbs. / 39.68 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE NEC Corporation 42.2 dB 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) 5 Revision 5.0 – July 17, 2013 5 5 CONFIGURATION GUIDE – NEC Express5800/R110e-1E Model R110e-1E Operating Systems and Virtualization Software Microsoft® Windows Server® 2003 R2, Standard Edition SP2 or later Microsoft® Windows Server® 2003 R2, Enterprise Edition SP2 or later Microsoft® Windows Server® 2003 R2, Standard x64 Edition Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise 6 Microsoft® Windows Server® 2012 Standard 6 Microsoft® Windows Server® 2012 Datacenter 7 Red Hat Enterprise Linux 5.8 or later 7 Red Hat Enterprise Linux 5.8 or later (EM64T) 7 Red Hat Enterprise Linux 6.2 or later (x86) 7 Red Hat Enterprise Linux 6.2 or later (x86_64) 8 VMware ESXi 5.0 update 1 7 VMware ESXi 5.1 1 2 3 4 5 6 7 8 Embedded SATA RAID controller is supported only on Windows operating systems. The PCIe slot works at PCIe 2.0 speeds on Pentium processor systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. Operable up to 35°C (95°F) when four hard drives are installed. For Windows Server 2012 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html VMware ESXi 5.0 and 5.1 are supported only on Xeon processor systems. NEC Corporation Revision 5.0 – July 17, 2013 6 External Views Front and Rear Views Front View for 2.5-inch Drive Model D F H E G J L I M N K C B A Front View for 3.5-inch Drive Model D F H E G J I L M N K B C A Legend A. Drive Bays H. UID LED B. Optical Drive Bay I. System Status LED C. USB Connectors J. BMC Reset Switch D. Power LED K. Dump (NMI) Switch E. Hard Drive Activity LED L. UID LED Button F. Data LAN 1 Activity LED M. Power Button G. Data LAN 2 Activity LED N. Pull-out Tab NEC Corporation Revision 5.0 – July 17, 2013 7 Rear View K L I J C H D F E A B G Legend A. PCI Slot (Low profile) G. UID LED / Button B. PCI Slot (Low profile) H. Power LED C. Data LAN 1 Connector I. Serial Port Connector D. Data LAN 2 Connector J. VGA Connector E. Management LAN Connector K. Power Unit USB Connectors L. AC Inlet F. Dimensions (mm) NEC Corporation Revision 5.0 – July 17, 2013 8 Configuration Diagram 2.5-inch Drive Model 2.5-inch Drive Cage Processor 1 DIMM 4 DIMMs Power Supply Legend: PCI 1 2 BBU slots PCIe 3.0 or 2.0 Cooing Fan 6 Drive Bays Media Bay CHASSIS REAR PCI 2 CHASSIS INSIDE Media Bay CHASSIS FRONT Minimum requirement components Power Supply Standard components 3.5-inch Drive Model CHASSIS REAR Processor 1 DIMM 4 DIMMs Media Bay Power Supply Legend: NEC Corporation Cooing Fan Media Bay 4 Drive Bays 3.5-inch Drive Cage PCIe 3.0 or 2.0 PCI 1 PCI 2 CHASSIS INSIDE 2 BBU slots CHASSIS FRONT Minimum requirement components Revision 5.0 – July 17, 2013 Power Supply Standard components 9 Expansion Slots #1 #2 Legend #1 PCIe 3.0 or 2.0 x8, x16 connector, Low profile, up to 200 mm length #2 PCIe 3.0 or 2.0 x8, x8 connector, Low profile, up to 200 mm length NOTE: The slots work at PCIe 3.0 speeds on Xeon processor systems. NEC Corporation Revision 5.0 – July 17, 2013 10 Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800/R110e-1E No CPU, no RAM, no 2.5-inch HDD, no Front bezel Including: 2.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD NEC Express5800/R110e-1E No CPU, no RAM, no 3.5-inch HDD, no Front bezel Including: 3.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD N8100-1933F N8100-1932F NOTE: The base model must be ordered with a processor kit. 2 Processor Available sockets: 1 Category Product Name / Description Part Number Processors Required Processor Kit (2C/G2020) Intel® Pentium ® Processor G2020 (2.90 GHz, 2C/2T, 3 MB) Processor Kit (2C/E3-1220Lv2) Intel® Xeon ® Processor E3-1220Lv2 (2.30 GHz, 2C/4T, 3 MB) NOTE: The kit is supported only on 3.5-inch drive model. Processor Kit (4C/E3-1220v2) Intel® Xeon ® Processor E3-1220v2 (3.10 GHz, 4C/4T, 8 MB) Processor Kit (4C/E3-1265Lv2) Intel® Xeon ® Processor E3-1265Lv2 (2.50 GHz, 4C/8T, 8 MB) NOTE: The kit is supported only on 3.5-inch drive model. Processor Kit (4C/E3-1270v2) Intel® Xeon ® Processor E3-1270v2 (3.50 GHz, 4C/8T, 8 MB) N8101-638F N8101-589F N8101-590F N8101-591F N8101-592F NOTE: The processor kit must be ordered with the base model. 3 Memory Available slots: 4 Product Name / Description Part Number 2GB DDR3-1600 UNB Memory Kit 2GB Unbuffered ECC DIMM, DDR3-1600(PC3-12800) 4GB DDR3-1600 UNB Memory Kit 4GB Unbuffered ECC DIMM, DDR3-1600(PC3-12800) 8GB DDR3-1600 UNB Memory Kit 8GB Unbuffered ECC DIMM, DDR3-1600(PC3-12800) N8102-501F N8102-502F N8102-503F NOTE: Minimum one memory kit must be installed. To install by double of memory kit is recommended in order to increase memory transfer speed by the dual-channel symmetric configuration. Actual memory speed drops to 1066 MHz when you choose Pentium Processor. NEC Corporation Revision 5.0 – July 17, 2013 11 Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by Operating Systems Microsoft Windows Server 2003 R2, Standard Edition Microsoft Windows Server 2008 Standard 4 GB 4 GB( HW-DEP enabled) App. 3.5 GB (HW-DEP disabled) Microsoft Windows Server 2003 R2, Standard x64 Edition Microsoft Windows Server 2008 Standard (x64) Microsoft Windows Server 2008 R2 Standard 32 GB 32 GB Microsoft Windows Server 2003 R2, Enterprise Edition Microsoft Windows Server 2008 Enterprise 64 GB 32 GB Microsoft Windows Server 2003 R2, Enterprise x64 Edition 1 TB 32 GB Microsoft Windows Server 2008 Enterprise (x64) Microsoft Windows Server 2008 R2 Enterprise 2 TB 32 GB Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter 4 TB 32 GB Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 16 GB 16 GB Red Hat Enterprise Linux 5 (EM64T) 1 TB 32 GB Red Hat Enterprise Linux 6 (x86_64) 2 TB 32 GB 2 TB 32 GB VMware ESXi 5.0, 5.1 1 Maximum Available Memory 1 Up to 1 TB of the main memory is available to each virtual machine. NEC Corporation Revision 5.0 – July 17, 2013 12 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration. 4.1.1 2.5-inch Drive Available Interface Non-RAID Refer to 4.2.1 SATA Refer to 4.2.2 SATA 128 MB Cache Refer to 4.2.3 SAS, SATA 512 MB Cache Refer to 4.2.4 SAS, SATA 512 MB Cache Refer to 4.2.5 SAS, SATA 1GB Cache/ Battery Refer to 4.2.6 SAS, SATA 1GB Cache/ CacheCade Refer to 4.2.7 SAS, SATA Embedded SATA RAID Controller RAID 0/1/10 Optional RAID Controller RAID 5/6 NOTE: The RAID controller with 1GB Cache / CacheVault does not support on Pentium G2020 processor systems. Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. All drives within a RAID array should be of the same type, capacity and rotation speed. All SAS hard drives within a system should be of the same rotation speed. Mixing SAS and SATA hard drives in the same system is not supported. NEC Corporation Revision 5.0 – July 17, 2013 13 4.1.2 3.5-inch Drive Available Interface Non-RAID Refer to 4.3.1 SATA Refer to 4.3.2 SATA 128 MB Cache Refer to 4.3.3 SATA 512 MB Cache Refer to 4.3.4 SATA 512 MB Cache Refer to 4.3.5 SATA 1GB Cache/ Battery Refer to 4.3.6 SATA 1GB Cache/ CacheVault Refer to 4.3.7 SATA Embedded SATA RAID Controller RAID 0/1/10 Optional RAID Controller RAID 5/6 NOTE: Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 5.0 – July 17, 2013 14 4.2 2.5-inch Drive Configuration 4.2.1 Embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb/s SATA, 2x 3Gb/s SATA Internal SATA Cable 4x Single-SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Drive 4 slots available SATA HDD (Standard) (Standard) N8150-356 N8150-357 N8150-358 NOTE: Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. 4.2.2 Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb/s SATA, 2x 3Gb/s SATA, RAID 0/1/10 capable Internal SATA Cable 4x Single-SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Drive 4 slots available SATA HDD (Standard) (Standard) N8150-356 N8150-357 N8150-358 NOTE Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. NEC Corporation Revision 5.0 – July 17, 2013 15 4.2.3 RAID 0/1 Controller with 128 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (128MB, RAID 0/1) Promise SuperTrak TX8760T-128 RAID 0/1/10, 128MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 3Gb/s RAID Battery Backup Unit for Promise SuperTrak TX8760T Internal SAS Cable 1x Mini-SAS - 4x Single SATA Internal SAS Cable 1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives NOTE: To install five drives or more, the cable is required. 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-128 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322 RAID BBU Recommended Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD SAS SSD N8103-140 K410-240(00) K410-204(00) (Standard) N8150-301 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 5.0 – July 17, 2013 16 4.2.4 RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID 0/1/10, 512MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS - 4x Single SATA Internal SAS Cable 1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives NOTE: To install five drives or more, the cable is required. 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-149 RAID BBU Recommended Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD SAS SSD N8103-154 K410-240(00) K410-204(00) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 5.0 – July 17, 2013 17 4.2.5 RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS - 4x Single SATA Internal SAS Cable 1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-150 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322 RAID BBU Recommended Cable Required Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-154 K410-240(00) K410-204(00) (Standard) N8150-301 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 5.0 – July 17, 2013 18 4.2.6 RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-151 Internal SAS Cable 1x Mini-SAS - 4x Single SATA Internal SAS Cable 1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives NOTE: To install five drives or more, the cable is required. 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s K410-240(00) RAID BBU Recommended SSD Caching Recommended Cable Required Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-154 N8103-156 K410-204(00) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 5.0 – July 17, 2013 19 4.2.7 RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-152 Internal SAS Cable 1x Mini-SAS - 4x Single SATA Internal SAS Cable 1x Mini-SAS - 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 73.2GB 15K Hot Plug 2.5-inch SAS HDD 1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s K410-240(00) SSD Caching Recommended Cable Required Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-156 K410-204(00) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-302 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: The RAID configuration does not support on Pentium G2020 Processor systems. All drives within a RAID array should be of the same type, capacity and rotation speed. For VMware ESXi 5.x installation, to download the CIM provider is required. For VMware ESXi 5.x systems, monitoring the status of a RAID array with NEC ESMPRO is not supported. NEC Corporation Revision 5.0 – July 17, 2013 20 4.3 3.5-inch Drive Configuration 4.3.1 Embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb/s SATA, 2x 3Gb/s SATA Internal SATA Cable (Standard) Cable (Standard) 4x Single-SATA Drive Cage Drive 4 slots available 3.5-inch Drive Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm (Standard) N8150-363 N8150-364 N8150-354 NOTE Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller. 4.3.2 Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 2x 6Gb/s SATA, 2x 3Gb/s SATA, RAID 0/1/10 capable Internal SATA Cable (Standard) Cable (Standard) 4x Single-SATA HDD Cage Drive 4 slots available 3.5-inch Drive Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID controller is required to configure RAID array for other operating systems. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB and 3TB HDDs. All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 5.0 – July 17, 2013 21 4.3.3 RAID 0/1 Controller with 128 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (128MB, RAID 0/1) Promise SuperTrak TX8760T-128 RAID 0/1/10, 128MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 3Gb/s RAID Battery Backup Unit for Promise SuperTrak EX8760T Internal SAS Cable 1x Mini-SAS - 4x Single SATA 3.5-inch HDD Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-128 RAID BBU Recommended Cable Required HDD Cage Drive 4 slots available N8103-140 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 NOTE: All hard drives within a RAID array should be of the same capacity. 4.3.4 RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID 0/1, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS - 4x Single SATA 3.5-inch HDD Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-149 RAID BBU Recommended Cable Required HDD Cage Drive 4 slots available N8103-154 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 5.0 – July 17, 2013 22 4.3.5 RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS - 4x Single SATA 3.5-inch HDD Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-150 RAID BBU Recommended Cable Required HDD Cage Drive 4 slots available N8103-154 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. 4.3.6 RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS - 4x Single SATA 3.5-inch HDD Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-151 RAID BBU Recommended Cable Required HDD Cage Drive 4 slots available N8103-154 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 5.0 – July 17, 2013 23 4.3.7 RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included Internal SAS Cable 1x Mini-SAS - 4x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug hard drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-152 Cable Required Drive Cage Drive 4 slots available K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. For VMware ESXi 5.x installation, to download the CIM provider is required. For VMware ESXi 5.x systems, monitoring the status of a RAID array with NEC ESMPRO is not supported. 5 Optical Drive Category Product Name / Description Part Number Internal 1 slot available Internal Slim DVD-ROM drive Slim DVD-ROM drive Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software External DVD-ROM drive DVD-ROM drive, Bus powered, 1.2 A required N8151-100 External N8151-107F N8160-91 NOTE: Up to 1 optical drive can be connected. NEC Corporation Revision 5.0 – July 17, 2013 24 6 PCI Card Please refer to NEC Corporation Revision 5.0 – July 17, 2013 25 Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 6.1 Network Interface Controller Category Adapter GbE 10GbE SPF+ Module Product Name / Description Part Number 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - Up to 1 adapter is supported when RHEL6 is installed. - Supports up to 2 adapters covering 10Gb Converged Network Adapter and 10Gb Network Adapter. N8104-138 Dual Port 10Gb Converged Network Adapter BROCADE 1020 Dual Port 10Gbps Converged Network Adapter PCIe 2.0 x8, 2 x SFP modules, Max. one adapter NOTE: - Supports up to two adapters of10Gb Converged Network Adapter and 10Gb Network Adapter. N8104-131 SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-128 N8104-129 N8104-132 N8104-128 NIC Teaming feature - NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2003 R2 and Windows Server 2008 support BASP (Broadcom Advanced Server Program) teaming while Windows Server 2012 and Linux support teaming with bonding function supported by OS. Network Interface Team Operating Systems 1GbE NIC Embedded 1GbE NIC and N8104-138/-132 Up to four teams per one system Up to four ports per one team Windows Server 2003 R2 Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Red Hat Enterprise Linux 10GbE NIC N8104-128 Up to two teams per one system Up to two ports per one team Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Red Hat Enterprise Linux NOTE: NIC Teaming feature is not supported on iSCSI interfaces. The network interfaces for teaming must be the same. When 10GbE and 1GbE NIC teaming are mixed, the teams must be up to four per one system. NEC Corporation Revision 5.0 – July 17, 2013 26 Using iSCSI See the table below for supported network interfaces and OS combinations. Categor Network Interface Operating Systems 1GbE Embedded 1GbE NIC Windows Server 2008 R2, Windows Server 2012, Red Hat Linux, VMware N8104-138 Windows Server 2008 R2, Windows Server 2012, Red Hat Linux, VMware N8104-132 Windows Server 2008 R2, Windows Server 2012, Red Hat Linux, VMware N8104-128 Windows Server 2008, Windows Server 2008 R2, Red Hat Linux, VMware y 10GbE NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 6.2 External Storage Controller 6.2.1 RAID Controller Category Product Name / Description Part Number Controller RAID Controller (1GB, RAID0/1/5/6) LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9285-8e N8103-160 RAID BBU N8103-162 NOTE: To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. 6.2.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (1ch) Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 NOTE: The controller does not support on Pentium G2020 Processor systems. Fibre Channel Controller (2ch) Emulex LightPulse LPe16002B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 NOTE: The controller does not support on Pentium G2020 Processor systems. N8190-153 SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 N8103-142 SAS NEC Corporation Revision 5.0 – July 17, 2013 N8190-154 N8190-157 N8190-158 27 6.3 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A NOTE: Up to one Serial Port Adapter can be installed. 7 Other Add-in Components 7.1 Internal Flash Memory Available socket: 1 Product Name / Description Part Number Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDER DVD without DVD media NOTE: Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory. The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility - Performance of the Test and Diagnosis Tool N8115-05 7.2 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 NOTE: Up to one drive can be connected. 7.3 Front Bezel Product Name / Description Part Number Front Bezel Front bezel for R110d-1E N8146-37F NEC Corporation Revision 5.0 – July 17, 2013 28 8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM Keypad 8.2 Product Name / Description Part Number 17-inch LCD Console Drawer (8 port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m 17inch LCD Console Drawer (1 port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1 port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1 port) N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F N8143-84F N8143-85 N8143-87 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(1A) Cable KVM Cascading NEC Corporation Revision 5.0 – July 17, 2013 K410-118(03) K410-118(05) K410-119(1A) 29 8.3 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License kit N8115-04 License for one server. Remote console and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. NEC Corporation Revision 5.0 – July 17, 2013 30 References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring 3 4 Hardware configuration information collection Hardware event log collection 2 2 BIOS/POST stall, Booting, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility 1 Panic screen, Boot screen 1,3 CUI-based screen (OS console) 1,4 GUI-based screen (OS console) - Remote reset/power on-off/ dump Remote Power Capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) OS shutdown Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) Scheduling (without UPS) Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection IPMI support 2.0 2.0 Industry Standard 2 Temperature/fan/voltage/power consumption/degeneration(memory) Boot monitoring Remote control (via LAN) 1 With Remote KVM and Media License kit 2 2 2 2 The optional serial port is not available for the feature The feature is not supported on VMware systems Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 5.0 – July 17, 2013 31 OS Support Matrix for PCI Cards and Embedded Controllers ESXi 5.0 ESXi 5.1 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 WS 2003R2 x64 WS 2003R2 WS 2008 x64 WS 2008 WS 2008R2 WS 2012 Part Number Product Name - Embedded SATA non-RAID Controller - Embedded SATA RAID Controller - - Embedded 1GbE NIC N8103-142 SAS controller N8103-128 RAID controller (128MB, RAID 0/1) - N8103-149 RAID controller (512MB, RAID 0/1) N8103-150 RAID controller (512MB, RAID 0/1/5/6) N8103-151 RAID controller (1GB, RAID 0/1/5/6) N8103-152 RAID controller (1GB, RAID 0/1/5/6) - N8103-160 RAID controller (1GB, RAID 0/1/5/6) N8190-153 Fibre Channel Controller N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller - - - - - - - - - N8190-158 Fibre Channel Controller (2ch) - - - - - - - - - N8104-138 1000BASE-T adapter (1ch) N8104-132 1000BASE-T adapter (2ch) N8104-128 10GBASE Adapter (SFP+/2ch) - - N8104-131 Dual Port 10Gb Converged Network Adapter - - - - NEC Corporation Revision 5.0 – July 17, 2013 - - - - - - - - - - - 32 Supported PCI cards and Installable Slots Slots Part Number Product Name #1 #2 N8103-142 SAS Controller N8103-128 RAID Controller (128MB, RAID 0/1) - N8103-149 RAID Controller (512MB,RAID 0/1) - N8103-150 RAID Controller (512MB,RAID 0/1/5/6) - N8103-151 RAID Controller (1GB,RAID 0/1/5/6) - N8103-152 RAID Controller (1GB,RAID 0/1/5/6) - N8103-160 RAID Controller (1GB,RAID 0/1/5/6) N8190-153 Fibre Channel Controller N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller N8190-158 Fibre Channel Controller (2ch) N8104-138 1000BASE-TAdapter (1ch) N8104-132 1000BASE-TAdapter (2ch) N8104-128 10GBASE Adapter (SFP+/2ch) N8104-131 Dual Port 10Gb Converged Network Adapter N8117-01A Serial Port Adapter NEC Corporation Revision 5.0 – July 17, 2013 33 Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 5.0 – July 17, 2013 34 Revision History Revision Date Description 5.0 July 17, 2013 New products added: 1.2TB 10K Hot Plug 2.5-inch SAS HDD / N8150-408 4.0 April 16, 2013 New products added: Processor Kit (2C/G2020) / N8101-638F 4TB 7.2K Hot Plug 3.5-inch SATA HDD / N8150-395 Fibre Channel Controller (1ch) / N8190-157 Fibre Channel Controller (2ch) / N8190-158 Part number changed: Internal DVD Super Multi Drive / N8151-107F External DVD-ROM Drive / N8160-91 Discontinued products removed: Processor Kit (2C/G640) / N8101-588F 100GB SSD / N8150-709 400GB SSD / N8150-710 Others: Support NIC teaming on Windows Server 2012 systems. Support N8103-142 SAS Controller on Windows Server 2012 systems 3.0 December 21, 2012 Other: Add Windows Server 2012 to the list of operating system supported Support N8103-152 RAID Controller on VMware ESXi 5.x systems Support 10GbE NIC teaming with two or more 10GbE NIC cards. Update OS support matrix 2.0 October 31, 2012 New products added: RAID Controller (1GB, RAID 0/1/5/6) / N8103-152 200GB SSD / N8150-711 400GB SSD / N8150-712 Discontinued products removed: 100GB SSD / N8150-707 SAS Controller / N8103-104A Other: Add VMware ESXi 5.1 to the list of operating system supported Support bonding feature on Linux operating system using 10GbE NIC Update OS support matrix 1.0 July 26, 2012 Initial release NEC Corporation Revision 5.0 – July 17, 2013 35