NEC Express5800/R110f-1E System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. January 16, 2014 Revision 2.1 NEC Corporation SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ....................................................................................................... 10 Front and Rear Views ......................................................................................................................... 10 Dimensions (mm) ................................................................................................................................ 12 CONFIGURATION DIAGRAM ....................................................................................... 13 EXPANSION SLOTS ..................................................................................................... 14 SERVER CONFIGURATION ......................................................................................... 15 1 2 3 4 5 6 7 8 Base Models ................................................................................................................................. 15 Processor ..................................................................................................................................... 15 Memory ......................................................................................................................................... 16 Internal Hard Disk Drives ............................................................................................................ 17 4.1 RAID Configuration .............................................................................................................. 17 4.2 2.5-inch Drive Configuration ................................................................................................ 19 4.3 3.5-inch Drive Configuration ................................................................................................ 30 Optical Drive ................................................................................................................................. 33 PCI Card ........................................................................................................................................ 34 6.1 Network Interface Controller ................................................................................................ 34 6.2 External Storage Controller ................................................................................................. 35 6.3 Serial Port Adapter .............................................................................................................. 37 Other Add-in Components .......................................................................................................... 37 7.1 Cooling Fan Kit .................................................................................................................... 38 7.2 Trusted Platform Module Kit ................................................................................................ 38 7.3 Internal Flash Memory ......................................................................................................... 38 7.4 Flash FDD............................................................................................................................ 38 7.5 Front Bezel .......................................................................................................................... 39 Add-on Components ................................................................................................................... 40 8.1 17-inch LCD Console Drawer .............................................................................................. 40 8.2 KVM Switch ......................................................................................................................... 40 8.3 Server Management License............................................................................................... 41 8.4 Dust Proof Filter Kit ............................................................................................................. 41 REFERENCES............................................................................................................... 42 Server Management ............................................................................................................................ 42 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 43 Supported PCI cards and Installable Slots....................................................................................... 44 Copyright Notice and Liability Disclaimer ........................................................................................ 45 REVISION HISTORY ..................................................................................................... 46 NEC Corporation Revision 2.1 – January 16, 2014 2 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Technical Specification Key Features High performance with the latest Intel® Xeon® processor E3-1200 v3 product family Up to 32 GB of high speed DDR3-1600 memory High energy efficiency with intelligent fan control, power capping feature and 80 PLUS® Platinum or Gold power supply Full manageability by integrated EXPRESSSCOPE Engine 3 Specification 2.5-inch Drive Model (1/2) Model R110f-1E Part Number Processor N8100-1999F, N8100-2000F Type Intel® Pentium® Processor G3220 Intel® Xeon® Processor E3-1220 v3 Intel® Xeon® Processor E3-1230L v3 Clock Speed 3 GHz 3.10 GHz 1.80 GHz Number of Processor 1 Cache 8 MB Cores and Threads 2C / 2T 4C / 4T 4C / 8T Chipset Memory Internal Storage Intel® C224 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity SATA HDD: 8 TB (8 x 1 TB) SAS HDD : 9.6 TB (8 x 1.2 TB) SAS SSD 3.2 TB (8 x 400 GB) Disk Controller SATA : 6 Gb/s (Integrated) SAS : 6 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 1 Disk Drive Bays 4 1 Expansion Slots Video Interfaces NEC Corporation Total: 2 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 2.0 x4 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 3 USB3.0 (1 front, 2 rear) 4 USB2.0 (1 front, 2 rear, 1 internal) Revision 2.1 – January 16, 2014 3 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Model R110f-1E Interfaces (Continued) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, non-hot plug Power Supply 1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU 2 500 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption 1 2 3 4 5 6 (Max. Config, Idling) 127 VA / 118 Watt (Max. Config, Operating) 242 VA / 235 Watt 295 VA / 288 Watt 235 VA / 227 Watt Acoustic Noise Minimum Config. (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 44.3 dB 47.7 dB 44.4 dB 34.8 dB 46.8 dB 41.8 dB Weight (Minimum / Maximum) 10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 x86 Standard Microsoft® Windows Server® 2008 x86 Enterprise Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later (x86) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) 6 VMware ESXi 5.1 update 1 6 VMware ESXi 5.5 119 VA / 110Watt 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html Support on Xeon processor systems only. NEC Corporation Revision 2.1 – January 16, 2014 4 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E (2/2) Model R110f-1E Part Number Processor N8100-1999F, N8100-2000F Type Intel® Xeon® Processor E3-1230 v3 Intel® Xeon® Processor E3-1265L v3 Intel® Xeon® Processor E3-1270 v3 Clock Speed 3.30 GHz 2.50 GHz 3.50 GHz Number of Processor 1 Cache 8 MB Cores and Threads 4C / 8T Chipset Memory Internal Storage Intel® C224 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity SATA HDD: 8 TB (8 x 1 TB) SAS HDD : 9.6 TB (8 x 1.2 TB) SAS SSD 3.2 TB (8 x 400 GB) Disk Controller SATA : 6 Gb/s (Integrated) SAS : 6 Gb/s (Optional) RAID SATA : RAID 0/1/10 (Standard ), RAID 5/6/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 1 Disk Drive Bays 4 1 Expansion Slots Video Total: 2 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 2.0 x4 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 3 USB3.0 (1 front, 2 rear) 4 USB2.0 (1 front, 2 rear, 1 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, non-hot plug Power Supply 1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU 2 500 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption Acoustic Noise (Sound Pressure 3 Level) NEC Corporation (Max. Config, Idling) 127 VA / 118 Watt (Max. Config, Operating) 198 VA / 291 Watt 262 VA / 256 Watt 300 VA / 293 Watt Minimum Config. 47.7 dB 44.4 dB 47.7 dB Maximum Config. 46.8 dB 41.8 dB 46.8 dB Revision 2.1 – January 16, 2014 5 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 1 2 3 4 5 Model R110f-1E Dimensions (W x D x H ) 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) Weight (Minimum / Maximum) 10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 x86 Standard Microsoft® Windows Server® 2008 x86 Enterprise Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later (x86) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) VMware ESXi 5.1 update 1 VMware ESXi 5.5 Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html 3.5-inch Drive Model (1/2) Model R110f-1E Part Number N8100-1986F, N8100-1998F Processor Type Intel® Pentium® Processor G3220 Intel® Xeon® Processor E3-1220 v3 Intel® Xeon® Processor E3-1230L v3 Clock Speed 3 GHz 3.10 GHz 1.80 GHz Number of Processor 1 Cache 8 MB Cores and Threads 2C / 2T 4C / 4T 4C / 8T Chipset Memory Internal Storage NEC Corporation Intel® C224 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity SATA : 16 TB (4 x 4 TB) Disk Controller SATA : 6Gb/s (Integrated) RAID SATA : RAID 0/1/10 (Standard ), RAID 5/6 (Optional) 1 Revision 2.1 – January 16, 2014 6 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Model R110f-1E Internal Storage Hot Plug Supported (Continued) Optical Disk Drive Optional Optical Drive Bays 1 Disk Drive Bays 4 Expansion Slots Video Total: 2 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 2.0 x4 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 3 USB3.0 (1 front, 2 rear) 4 USB2.0 (1 front, 2 rear, 1 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, non-hot plug Power Supply 1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU 2 500 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption (Max. Config, Idling) 102 VA / 94 Watt 112 VA / 104 Watt 102 VA / 94 Watt (Max. Config, Operating) 214 VA /207 Watt 277 VA / 270 Watt 206 VA / 197 Watt Acoustic Noise Minimum Config. (Sound Pressure Maximum Config. 3 Level) Dimensions (W x D x H ) 44.3 dB 47.7 dB 44.4 dB 34.8 dB 46.8 dB 41.8 dB Weight (Minimum / Maximum) 10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 x86 Standard Microsoft® Windows Server® 2008 x86 Enterprise Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later (x86) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) 6 VMware ESXi 5.1 update 1 6 VMware ESXi 5.5 1 2 3 4 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and NEC Corporation Revision 2.1 – January 16, 2014 7 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 5 6 install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html Support on Xeon processor systems only. (2/2) Model R110f-1E Part Number Processor N8100-1986F, N8100-1998F Type Intel® Xeon® Processor E3-1230 v3 Intel® Xeon® Processor E3-1265L v3 Intel® Xeon® Processor E3-1270 v3 Clock Speed 3.30 GHz 2.50 GHz 3.50 GHz Number of Processor 1 Cache 8 MB Cores and Threads 4C / 8T Chipset Memory Internal Storage Intel® C224 Chipset Type DDR3-1600 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 32 GB (4 x 8 GB) Standard Capacity 0 GB Maximum Capacity SATA : 16 TB (4 x 4 TB) Disk Controller SATA : 6Gb/s (Integrated) RAID SATA : RAID 0/1/10 (Standard ), RAID 5/6 (Optional) Hot Plug Supported Optical Disk Drive Optional Optical Drive Bays 1 Disk Drive Bays 4 1 Expansion Slots Video Total: 2 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 2.0 x4 (x8 connector) Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color 1280 x 1024 / 16.7M 2 Interfaces 1 VGA (15-pin mini D-sub,1 rear) 1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear) 3 USB3.0 (1 front, 2 rear) 4 USB2.0 (1 front, 2 rear, 1 internal) 2 1000BASE-T LAN connector (RJ-45, 2 rear) 1 100BASE-TX LAN connector for management (RJ-45, 1 rear) Server Management EXPRESSSCOPE Engine 3 Redundant Fan Optional, non-hot plug Power Supply 1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU 2 500 Watt 80 PLUS® Gold certified Hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz Power Consumption Acoustic Noise (Sound Pressure 3 Level) NEC Corporation (Max. Config, Idling) 112 VA / 104 Watt 102 VA / 94 Watt 117 VA / 108 Watt (Max. Config, Operating) 289 VA / 282 Watt 235 VA / 227 Watt 295 VA / 287 Watt Minimum Config. 47.7 dB 44.4 dB 47.7 dB Maximum Config. 46.8 dB 41.8 dB 46.8 dB Revision 2.1 – January 16, 2014 8 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Model R110f-1E Dimensions (W x D x H ) 444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U) Weight (Minimum / Maximum) 10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM Operating Systems and Virtualization Software Microsoft® Windows Server® 2008 x86 Standard Microsoft® Windows Server® 2008 x86 Enterprise Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later (x86) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) VMware ESXi 5.1 update 1 VMware ESXi 5.5 1 2 3 4 5 Embedded SATA RAID controller is supported only on limited operating systems. Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html NEC Corporation Revision 2.1 – January 16, 2014 9 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E External Views Front and Rear Views Front View for 2.5-inch Drive Model C D E GI K M N F H J L O A P B Front View for 3.5-inch Drive Model C D E GI K M N B F H J L O A Legend A. Drive Bays I. UID LED B. Optical Drive Bay J. System Status LED C. USB 2.0 Connector K. BMC Reset Switch D. USB 3.0 Connector L. Dump (NMI) Switch E. Power LED M. UID LED Button F. Drive Activity LED N. Power Button G. Data LAN 1 Activity LED O. Pull-out Tab H. Data LAN 2 Activity LED P. Optional Drive Cage Bay NEC Corporation Revision 2.1 – January 16, 2014 10 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Rear View for Non-redundant PSU Configuration L J M K I C D F G A B E H Rear View for Redundant PSU Configuration L L M M J K I C D F G A B E H Legend A. PCI Slot (Low profile) B. H. UID LED / Button PCI Slot (Low profile) I. Power LED C. Data LAN 1 Connector J. Serial Port Connector D. Data LAN 2 Connector K. VGA Connector E. Management LAN Connector L. Power Unit F. USB 2.0 Connectors M. AC Inlet G. USB 3.0 Connectors NEC Corporation Revision 2.1 – January 16, 2014 11 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Dimensions (mm) NEC Corporation Revision 2.1 – January 16, 2014 12 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Configuration Diagram 2.5-inch Drive Model Legend: Mandatory Components Standard Components Mandatory Components Standard Components 3.5-inch Drive Model Legend: NEC Corporation Revision 2.1 – January 16, 2014 13 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Expansion Slots PCI 1A PCI 1B Legend #1A PCIe 3.0 x8, x16 connector, Low profile, up to 173 mm length #1B PCIe 2.0 x4, x8 connector, Low profile, up to 173 mm length NEC Corporation Revision 2.1 – January 16, 2014 14 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800/R110f-1E No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no Front bezel Including: 3.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD NEC Express5800/R110f-1E No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no Front bezel Including: 3.5-inch Drive Cage, 2 x 500 Watt hot plug power supply, EXPRESSBUILDER DVD NEC Express5800/R110f-1E No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no Front bezel Including: 2.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD NEC Express5800/R110f-1E No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no Front bezel Including: 2.5-inch Drive Cage, 2 x 500 Watt hot plug power supply, EXPRESSBUILDER DVD N8100-1986F N8100-1998F N8100-1999F N8100-2000F NOTE: The base model must be ordered with a processor kit, a memory kit, a cooling fan kit, and internal hard drive cable. 2 Processor Available sockets: 1 Category Product Name / Description Part Number Processors Required Pentium G3220 Processor Kit Intel® Pentium ® Processor G3220 (3 GHz, 2C/2T, 3 MB) Xeon E3-1220 v3 Processor Kit Intel® Xeon ® Processor E3-1220 v3 (3.10 GHz, 4C/4T, 8 MB) Xeon E3-1230L v3 Processor Kit Intel® Xeon ® Processor E3-1230L v3 (1.80 GHz, 4C/8T, 8 MB) Xeon E3-1230 v3 Processor Kit Intel® Xeon ® Processor E3-1230 v3 (3.30 GHz, 4C/8T, 8 MB) Xeon E3-1265L v3 Processor Kit Intel® Xeon ® Processor E3-1265L v3 (2.50 GHz, 4C/8T, 8 MB) Xeon E3-1270 v3 Processor Kit Intel® Xeon ® Processor E3-1270 v3 (3.50 GHz, 4C/8T, 8 MB) N8101-623F N8101-626F N8101-627F N8101-628F N8101-629F N8101-639F NOTE: The processor kit must be ordered with the base model. VMware ESXi is not supported on Pentium processor systems. NEC Corporation Revision 2.1 – January 16, 2014 15 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 3 Memory Available slots: 4 Product Name / Description Part Number 2GB DDR3-1600 UNB Memory Kit 2GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800) 4GB DDR3-1600 UNB Memory Kit 4GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800) 8GB DDR3-1600 UNB Memory Kit 8GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800) N8102-523F N8102-524F N8102-525F NOTE: Minimum one memory kit must be installed. To install by double of memory kit is recommended in order to increase memory transfer speed by the dual-channel symmetric configuration. Actual memory speed drops to 1333 MHz when you choose Pentium Processor. Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by Operating Systems 4 GB 4 GB( HW-DEP enabled) App. 3.5 GB (HW-DEP disabled) 32 GB 32 GB 64 GB 32 GB 2 TB 32 GB Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter 4 TB 32 GB Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 16 GB 16 GB Red Hat Enterprise Linux 5 (EM64T) 1 TB 32 GB Red Hat Enterprise Linux 6 (x86_64) 3 TB 32 GB VMware ESXi 5.1 2 2 TB 32 GB VMware ESXi 5.5 2 4 TB 32 GB Microsoft Windows Server 2008 Standard Microsoft Windows Server 2008 R2 Standard 1 Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2008 R2 Enterprise 1 1 1 Maximum Available Memory The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012, Windows Server 2012 R2 : 4 TB 2 Up to 1TB of main memory is available to each virtual machine. NEC Corporation Revision 2.1 – January 16, 2014 16 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration. 4.1.1 Up to six 2.5-inch Drive Available Interface Non-RAID Refer to 4.2.1 SATA Refer to 4.2.2 SATA No Cache Refer to 4.2.3 SAS, SATA 512 MB Cache Refer to 4.2.4 SAS, SATA 512 MB Cache Refer to 4.2.5 SAS, SATA 1GB Cache/ Battery Refer to 4.2.6 SAS, SATA 1GB Cache/ CacheCade Refer to 4.2.7 SAS, SATA Embedded SATA RAID Controller RAID 0/1/10 Optional RAID Controller RAID 5/6 4.1.2 Up to eight 2.5-inch Drive Available Interface RAID 0/1/10 RAID 5/6 No Cache Refer to 4.2.8 SAS, SATA 512 MB Cache Refer to 4.2.9 SAS, SATA 512 MB Cache Refer to 4.2.10 SAS, SATA 1GB Cache/ Battery Refer to 4.2.11 SAS, SATA 1GB Cache/ CacheCade Refer to 4.2.12 SAS, SATA NOTE: Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. Internal optical drive cannot be installed when N8154-52 2.5-inch Hot Plug Drive Cage Kit is installed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. All drives within a RAID array should be of the same type, capacity and rotation speed. All SAS hard drives within a system should be of the same rotation speed. Mixing SAS and SATA hard drives in the same system is not supported. NEC Corporation Revision 2.1 – January 16, 2014 17 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.1.3 3.5-inch Drive Available Interface Non-RAID Refer to 4.3.1 SATA Refer to 4.3.2 SATA No Cache Refer to 4.3.3 SATA 512 MB Cache Refer to 4.3.4 SATA 512 MB Cache Refer to 4.3.5 SATA 1GB Cache/ Battery Refer to 4.3.6 SATA 1GB Cache/ CacheVault Refer to 4.3.7 SATA Embedded SATA RAID Controller RAID 0/1/10 Optional RAID Controller RAID 5/6 NOTE: Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – January 16, 2014 18 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2 2.5-inch Drive Configuration 4.2.1 Up to four Drives with Embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA Internal SAS/SATA Cable MiniSAS-4x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Required Drive Cage Drive 4 slots available SATA HDD K410-289(00) (Standard) N8150-356 N8150-357 N8150-358 NOTE: Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller. 4.2.2 Up to four Drives with Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA, RAID 0/1/10 capable Internal SATA Cable miniSAS to 4x Single-SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Drive 4 slots available SATA K410-289(00) (Standard) N8150-356 N8150-357 N8150-358 NOTE Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – January 16, 2014 19 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.3 Up to six Drives with RAID 0/1 Controller without Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (0MB, RAID 0/1) LSI MegaRAID SAS 9240-8i RAID0/1/10, Cache less, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-171 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm N8150-322 Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD K410-240(00) K410-204(00) (Standard) N8150-301 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 20 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.4 Up to six Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/10, 512MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-149 RAID BBU Recommended Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD SAS SSD N8103-154 K410-240(00) K410-204(00) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 21 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.5 Up to six Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-150 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322 RAID BBU Recommended Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD SAS SSD N8103-154 K410-240(00) K410-204(00) (Standard) N8150-301 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 22 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.6 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-151 Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s K410-240(00) RAID BBU Recommended SSD Caching Recommended Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD SAS SSD N8103-154 N8103-156 K410-204(00) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 23 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.7 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-152 Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s K410-240(00) SSD Caching Recommended Cable Required Cable Drive Cage Drive 4 to 6 slots available SAS HDD SATA HDD SAS SSD N8103-156 K410-204(00) (Standard) N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 24 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.8 Up to eight Drives with RAID 0/1 Controller without Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (0MB, RAID 0/1) LSI MegaRAID SAS 9240-8i RAID 0/1/10, Cache less, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 2.5-inch Drive Cage Kit 2 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-171 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm N8150-322 Cable Required Cable Required Drive Cage Drive Cage Required Drive 8 slots available SAS HDD SATA HDD K410-240(00) K410-204(00) (Standard) N8154-52F N8150-301 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 25 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.9 Up to eight Drives with RAID 0/1 Controller with 512 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID 0/1/10, 512MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 2.5-inch Drive Cage Kit 2 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-149 RAID BBU Recommended Cable Required Cable Required Drive Cage Drive Cage Required Drive 8 slots available SAS HDD SATA HDD SAS SSD N8103-154 K410-240(00) K410-204(00) (Standard) N8154-52F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 26 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.10 Up to eight Drives with RAID 5/6 Controller with 512 GB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 2.5-inch Drive Cage Kit 2 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-150 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322 RAID BBU Recommended Cable Required Cable Required Drive Cage Drive Cage Required Drive 8 slots available SAS HDD SATA HDD SAS SSD N8103-154 K410-240(00) K410-204(00) (Standard) N8154-52F N8150-301 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 27 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.11 Up to eight Drives with RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-151 Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 2.5-inch Drive Cage Kit 2 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s K410-240(00) RAID BBU Recommended SSD Caching Recommended Cable Required Cable Required Drive Cage Drive Cage Required Drive 8 slots available SAS HDD SATA HDD SAS SSD N8103-154 N8103-156 K410-204(00) (Standard) N8154-52F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 28 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.2.12 Up to eight Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-152 Internal SAS Cable 1x Mini-SAS to 4x Single SATA Internal SAS Cable 1x Mini-SAS to 4x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 2.5-inch Drive Cage Kit 2 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s K410-240(00) SSD Caching Recommended Cable Required Cable Required Drive Cage Drive Cage Required Drive 8 slots available SAS HDD SATA HDD SAS SSD N8103-156 K410-204(00) (Standard) N8154-52F N8150-301 N8150-322 N8150-304 N8150-332 N8150-408 N8150-303 N8150-331 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. NEC Corporation Revision 2.1 – January 16, 2014 29 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.3 3.5-inch Drive Configuration 4.3.1 Embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller MiniSAS, 6Gb/s SATA Internal SAS/SATA Cable MiniSAS to 4x Single-SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Required Drive Cage Drive 4 slots available K410-288(00) (Standard) N8150-363 N8150-364 N8150-354 NOTE Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller. 4.3.2 Embedded SATA RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb/s SATA, 6Gb/s SATA Internal SAS/SATA Cable (Standard) Cable Required Drive Cage Drive 4 slots available K410-288(00) MiniSAS to 4x Single-SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs. All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – January 16, 2014 30 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.3.3 RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (0MB, RAID 0/1) LSI MegaRAID SAS 9240-8i RAID0/1/10, Cache less, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s Internal SAS Cable 1x Mini-SAS to 4x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-171 Cable Required Drive Cage Drive 4 slots available K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 NOTE: All hard drives within a RAID array should be of the same capacity. 4.3.4 RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID 0/1, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-149 RAID BBU Recommended Cable Required Drive Cage Drive 4 slots available N8103-154 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – January 16, 2014 31 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.3.5 RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-150 RAID BBU Recommended Cable Required Drive Cage Drive 4 slots available N8103-154 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. 4.3.6 RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9267-8i RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i Internal SAS Cable 1x Mini-SAS to 4x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-151 RAID BBU Recommended Cable Required Drive Cage Drive 4 slots available N8103-154 K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. NEC Corporation Revision 2.1 – January 16, 2014 32 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 4.3.7 RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included Internal SAS Cable 1x Mini-SAS to 4x Single SATA 3.5-inch Drive Cage 4 x 3.5-inch hot plug drive bays 500GB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 2TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 3TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm 4TB 7.2K Hot Plug 3.5-inch SATA HDD 1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm N8103-152 Cable Required Drive Cage Drive 4 slots available K410-240(00) (Standard) N8150-363 N8150-364 N8150-354 N8150-355 N8150-395 NOTE: All hard drives within a RAID array should be of the same capacity. 5 Optical Drive Category Product Name / Description Part Number Internal 1 slot available Internal Slim DVD-ROM drive Slim DVD-ROM drive Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software External DVD-ROM drive DVD-ROM drive, Bus powered, 1.2 A required N8151-119 External N8151-107F N8160-91 NOTE: Up to 1 optical drive can be connected. N8154-52 2.5-inch Hot Plug Drive Cage Kit cannot be installed when an internal optical drive is installed. NEC Corporation Revision 2.1 – January 16, 2014 33 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 6 PCI Card Please refer to Supported PCI cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 6.1 Network Interface Controller Category Adapter GbE 10GbE SPF+ Module NEC Corporation Product Name / Description Part Number 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Intel® 82580 Gigabit Ethernet Controller PCIe 2.0 x4 Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - Network cables with RJ-45 plug covers cannot be used. N8104-138 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - Supports either 10Gb Converged Network Adapter or 10Gb Network Adapter in RHEL 6 operating systems. N8104-128 Dual Port 10Gb Converged Network Adapter BROCADE 1020 Dual Port 10Gbps Converged Network Adapter PCIe 2.0 x8, 2 x SFP modules, Max. one adapter NOTE: - Supports either 10Gb Converged Network Adapter or 10Gb Network Adapter in RHEL 6 operating systems. N8104-131 SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-128 N8104-129 Revision 2.1 – January 16, 2014 N8104-132 N8104-145 N8104-133 34 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E NIC Teaming feature - NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS. Network Interface Team Operating Systems 1GbE NIC Embedded 1GbE NIC/N8104-138/-132/-133 Up to four teams per one system Up to four ports per one team Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 RHEL5.9* or later RHEL6.4* or later 1GbE NIC N8104-145 Up to four teams per one system Up to four ports per one team Windows Server 2008 Windows Server 2008 R2 10GbE NIC N8104-128 Up to two teams per one system Up to two ports per one team Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 RHEL5.9(EM64T)* or later RHEL6.4(x86_64)* or later * RHEL : Red Hat Enterprise Linux NOTE: Teaming feature is not supported on iSCSI interfaces. The network interfaces for teaming must be the same. When 10GbE and 1GbE LAN teams are mixed, the teams must be up to four per one system. Using iSCSI See the table below for supported network interfaces and OS combinations. Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC Windows Server 2008 R2, Windows Server 2012, RHEL, VMware N8104-138 Windows Server 2008 R2, Windows Server 2012, RHEL, VMware N8104-132 Windows Server 2008 R2, Windows Server 2012, RHEL, VMware N8104-133 Windows Server 2008 R2, Windows Server 2012, RHEL, VMware N8104-128 Windows Server 2008 / Windows Server 2008R2 / Windows Server 2012 / RHEL* / VMware 10GbE * RHEL : Red Hat Enterprise Linux NOTE: NIC Teaming feature is not supported on iSCSI interfaces. NEC Corporation Revision 2.1 – January 16, 2014 35 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 6.2 InfiniBand Category Product Name / Description Part Number Controller Single Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX353A-FCBT, FDR, PCIe 3.0(x8) Dual Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX354A-FCBT, FDR, PCIe 3.0(x8) InfiniBand Cable 2m/FRD Copper InfiniBand Cable 3m/FDR Copper InfiniBand Switch 36 ports/FDR Mellanox MSX6036F-1SFR 36 ports, FDR, One power supply module included, no power cord Redundant Power Supply Unit Power supply module for 36 ports InfiniBand switch, no power cord N8104-146 Cable Switch Unit Power Supply N8104-147 K410-304(02) K410-304(03) NE3707-061 NE3707-063 NOTE: The InfiniBand adapters and other options are make-to-order products. Please consult our sales representative in regards to production lead time. 6.3 External Storage Controller 6.3.1 RAID Controller Category Product Name / Description Part Number Controller RAID Controller (512MB, RAID0/1/5/6) LSI MegaRAID SAS 9285-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9285-8e N8103-160 RAID BBU N8103-162 NOTE: To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. NEC Corporation Revision 2.1 – January 16, 2014 36 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 6.3.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (1ch) Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 NOTE: - One controller can be installed on Pentium processor systems. Fibre Channel Controller (2ch) Emulex LightPulse LPe16002B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 NOTE: - The controller is supported only with Xeon processor. N8190-153 SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8 N8103-142 SAS N8190-154 N8190-157 N8190-158 NOTE: Mixing 8Gb fibre channel controllers and 16Gb fibre channel controllers in the same system is not supported. 6.4 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117-01A NOTE: Up to one Serial Port Adapter can be installed. NEC Corporation Revision 2.1 – January 16, 2014 37 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 7 Other Add-in Components 7.1 Cooling Fan Kit Product Name / Description Part Number Redundant Fan Kit Non-hot plug cooling fan for R110f-1E Non-redundant Fan Kit Non-hot plug cooling fan for R110f-1E N8181-111F N8181-115F NOTE: One of the fan kits must be installed. 7.2 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 1.2 module N8115-15 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this kit. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 7.3 Internal Flash Memory Available socket: 1 Product Name / Description Part Number Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without DVD media NOTE: Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory. The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility - Performance of the Test and Diagnosis Tool N8115-14 7.4 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 NOTE: Up to one drive can be connected. NEC Corporation Revision 2.1 – January 16, 2014 38 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 7.5 Front Bezel Product Name / Description Part Number Front Bezel Front bezel for R110f-1E N8146-38F NEC Corporation Revision 2.1 – January 16, 2014 39 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM Keypad 8.2 Product Name / Description Part Number 17-inch LCD Console Drawer (8 port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m 17inch LCD Console Drawer (1 port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1 port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1 port) N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F N8143-84F N8143-85 N8143-87 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(1A) Cable KVM Cascading NEC Corporation Revision 2.1 – January 16, 2014 K410-118(03) K410-118(05) K410-119(1A) 40 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E 8.3 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License kit N8115-04 License for one server. Remote console and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. 8.4 Dust Proof Filter Kit The server supports the dust resistant feature. Choose the following kit to install the system in dusty places. Product Name / Description Part Number Dust Proof Filter 10 sheets, dust proof filter for R110f-1E N8147-07 NOTE: The filter kit is make-to-order product. Please consult our sales representative in regards to production lead time. NEC Corporation Revision 2.1 – January 16, 2014 41 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Temperature/fan/voltage/power consumption/SystemLAN/degeneration(memory) Hardware configuration information collection Hardware event log collection Boot monitoring BIOS/POST stall, Booting, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM (via LAN) POST/BIOS setup, ROM utility Remote control (via LAN) 4 2 1 1,3 CUI-based screen (OS console) 1,4 GUI-based screen (OS console) - Remote KVM Video Record - Remote reset/power on-off/ dump Remote Power Capping BIOS/BMC FW update Remote BIOS setup(partial configuration only) 2 2 Remote media (CD/DVD/FD/USB) - CLP (Command Line Protocol) (DMTF compliant) Remote control via Web browser (multi user login at the same time) 2 2 Maintenance EXPRESSSCOPE® Profile key (Backup/restore BIOS/BMC setup information) Others Set automatic IP address via DNS/DHCP LDAP/Active Directory verification/user control Clock synchronization of main unit and the RTC Access log collection Industry Standard 3 Scheduling (without UPS, require NEC ESMPRO Manager) 2 2 Panic screen, Boot screen OS shutdown 1 With Remote KVM and Media License kit IPMI support 2.0 2.0 The optional serial port is not available for the feature The feature is not supported on VMware systems Monitoring boot screens is not supported on VMware systems. In VMware systems, only the direct console user interface is supported. NEC Corporation Revision 2.1 – January 16, 2014 42 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E OS Support Matrix for PCI Cards and Embedded Controllers ESXi 5.1 ESXi 5.5 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 WS 2008 WS 2008 R2 WS 2012 WS 2012 R2 Part Number Product Name - Embedded SATA non-RAID Controller - Embedded SATA RAID Controller - - Embedded 1GbE NIC N8103-142 SAS Controller - N8103-171 RAID Controller (0MB, RAID 0/1) - N8103-149 RAID controller (512MB, RAID 0/1) N8103-150 RAID controller (512MB, RAID 0/1/5/6) N8103-151 RAID controller (1GB, RAID 0/1/5/6) N8103-152 RAID controller (1GB, RAID 0/1/5/6) N8103-160 RAID controller (1GB, RAID 0/1/5/6) N8190-153 Fibre Channel Controller N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller - - - - - N8190-158 Fibre Channel Controller (2ch) - - - - - N8104-138 1000BASE-T Adapter (1ch) N8104-132 Dual Port 1000BASE-T Adapter N8104-145 Dual Port 1000BASE-T Adapter - N8104-133 Quad Port 1000BASE-T Adapter N8104-128 10GBASE Adapter (SFP+/2ch) N8104-131 Dual Port 10Gb Converged Network Adapter - - - - - - - - N8104-146 N8104-147 NEC Corporation Single Port InfiniBand Adapter Dual Port InfiniBand Adapter - - - - - - Revision 2.1 – January 16, 2014 - - - - - - - - - - - - 43 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Supported PCI cards and Installable Slots Slots Part Number Product Name #1 #2 N8103-142 SAS Controller N8103-171 RAID Controller (0MB, RAID 0/1) - N8103-149 RAID Controller (512MB,RAID 0/1) - N8103-150 RAID Controller (512MB,RAID 0/1/5/6) - N8103-151 RAID Controller (1GB,RAID 0/1/5/6) - N8103-152 RAID Controller (1GB,RAID 0/1/5/6) - N8103-160 RAID Controller (1GB,RAID 0/1/5/6) N8190-153 Fibre Channel Controller N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller N8190-158 Fibre Channel Controller (2ch) N8104-138 1000BASE-T Adapter (1ch) N8104-132 1000BASE-T Adapter (2ch) N8104-145 1000BASE-T Adapter (2ch) N8104-128 10GBASE Adapter (SFP+/2ch) N8104-131 Dual Port 10Gb Converged Network Adapter N8104-146 Single Port InfiniBand Adapter - N8104-147 Dual Port InfiniBand Adapter - N8117-01A Serial Port Adapter NEC Corporation Revision 2.1 – January 16, 2014 44 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 2.1 – January 16, 2014 45 SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E Revision History Revision Date Description 2.1 January 16, 2014 Others: Add Windows Server 2012 R2 to the list of operating system supported Update OS support matrix 2.0 October 25, 2013 New products added: Pentium G3220 Processor Kit / N8101-623F Single Port InfiniBand Adapter / N8104-146 Dual Port InfiniBand Adapter / N8104-147 InfiniBand Cable 2m/FRD / K410-304(02) InfiniBand Cable 3m/FRD / K410-304(03) InfiniBand Switch 36 ports/FDR / NE3707-061 Redundant Power Supply Unit / NE3707-063 Others: Add N8104-133 Quad Port 1000BASE-T Adapter to the support list Add VMware ESXi 5.5 to the list of operating system supported Update OS support matrix 1.0 July 17, 2013 Initial release NEC Corporation Revision 2.1 – January 16, 2014 46