Express5800/R110f-1E配置指南 (英文版)

NEC Express5800/R110f-1E
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
January 16, 2014
Revision 2.1
NEC Corporation
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ....................................................................................................... 10
Front and Rear Views ......................................................................................................................... 10
Dimensions (mm) ................................................................................................................................ 12
CONFIGURATION DIAGRAM ....................................................................................... 13
EXPANSION SLOTS ..................................................................................................... 14
SERVER CONFIGURATION ......................................................................................... 15
1
2
3
4
5
6
7
8
Base Models ................................................................................................................................. 15
Processor ..................................................................................................................................... 15
Memory ......................................................................................................................................... 16
Internal Hard Disk Drives ............................................................................................................ 17
4.1 RAID Configuration .............................................................................................................. 17
4.2 2.5-inch Drive Configuration ................................................................................................ 19
4.3 3.5-inch Drive Configuration ................................................................................................ 30
Optical Drive ................................................................................................................................. 33
PCI Card ........................................................................................................................................ 34
6.1 Network Interface Controller ................................................................................................ 34
6.2 External Storage Controller ................................................................................................. 35
6.3 Serial Port Adapter .............................................................................................................. 37
Other Add-in Components .......................................................................................................... 37
7.1 Cooling Fan Kit .................................................................................................................... 38
7.2 Trusted Platform Module Kit ................................................................................................ 38
7.3 Internal Flash Memory ......................................................................................................... 38
7.4 Flash FDD............................................................................................................................ 38
7.5 Front Bezel .......................................................................................................................... 39
Add-on Components ................................................................................................................... 40
8.1 17-inch LCD Console Drawer .............................................................................................. 40
8.2 KVM Switch ......................................................................................................................... 40
8.3 Server Management License............................................................................................... 41
8.4 Dust Proof Filter Kit ............................................................................................................. 41
REFERENCES............................................................................................................... 42
Server Management ............................................................................................................................ 42
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 43
Supported PCI cards and Installable Slots....................................................................................... 44
Copyright Notice and Liability Disclaimer ........................................................................................ 45
REVISION HISTORY ..................................................................................................... 46
NEC Corporation
Revision 2.1 – January 16, 2014
2
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Technical Specification
Key Features




High performance with the latest Intel® Xeon® processor E3-1200 v3 product family
Up to 32 GB of high speed DDR3-1600 memory
High energy efficiency with intelligent fan control, power capping feature and 80 PLUS® Platinum or
Gold power supply
Full manageability by integrated EXPRESSSCOPE Engine 3
Specification
2.5-inch Drive Model
(1/2)
Model
R110f-1E
Part Number
Processor
N8100-1999F, N8100-2000F
Type
Intel® Pentium®
Processor G3220
Intel® Xeon®
Processor E3-1220
v3
Intel® Xeon®
Processor E3-1230L
v3
Clock Speed
3 GHz
3.10 GHz
1.80 GHz
Number of Processor
1
Cache
8 MB
Cores and Threads
2C / 2T
4C / 4T
4C / 8T
Chipset
Memory
Internal Storage
Intel® C224 Chipset
Type
DDR3-1600 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
32 GB (4 x 8 GB)
Standard Capacity
0 GB
Maximum Capacity
SATA HDD: 8 TB (8 x 1 TB)
SAS HDD : 9.6 TB (8 x 1.2 TB)
SAS SSD 3.2 TB (8 x 400 GB)
Disk Controller
SATA : 6 Gb/s (Integrated)
SAS : 6 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard ), RAID 5/6/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
1
Expansion Slots
Video
Interfaces
NEC Corporation
Total: 2 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 2.0 x4 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1280 x 1024 / 16.7M
2
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
3 USB3.0 (1 front, 2 rear)
4 USB2.0 (1 front, 2 rear, 1 internal)
Revision 2.1 – January 16, 2014
3
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Model
R110f-1E
Interfaces (Continued)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 100BASE-TX LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
1
2
3
4
5
6
(Max. Config, Idling)
127 VA
/ 118 Watt
(Max. Config,
Operating)
242 VA
/ 235 Watt
295 VA
/ 288 Watt
235 VA
/ 227 Watt
Acoustic Noise
Minimum Config.
(Sound Pressure
Maximum Config.
3
Level)
Dimensions (W x D x H )
44.3 dB
47.7 dB
44.4 dB
34.8 dB
46.8 dB
41.8 dB
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 x86 Standard
Microsoft® Windows Server® 2008 x86 Enterprise
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
4
Microsoft® Windows Server® 2012 R2 Standard
4
Microsoft® Windows Server® 2012 R2 Datacenter
5
Red Hat Enterprise Linux 5.9 or later
5
Red Hat Enterprise Linux 5.9 or later (EM64T)
5
Red Hat Enterprise Linux 6.4 or later (x86)
5
Red Hat Enterprise Linux 6.4 or later (x86_64)
6
VMware ESXi 5.1 update 1
6
VMware ESXi 5.5
119 VA
/ 110Watt
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Embedded SATA RAID controller is supported only on limited operating systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the
operating environment.
For Windows Server 2012 R2 installation, download the driver kit from the following website and install
it after OS installation
http://www.nec.com/en/global/prod/express/download/
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
Support on Xeon processor systems only.
NEC Corporation
Revision 2.1 – January 16, 2014
4
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
(2/2)
Model
R110f-1E
Part Number
Processor
N8100-1999F, N8100-2000F
Type
Intel® Xeon®
Processor E3-1230
v3
Intel® Xeon®
Processor E3-1265L
v3
Intel® Xeon®
Processor E3-1270
v3
Clock Speed
3.30 GHz
2.50 GHz
3.50 GHz
Number of Processor
1
Cache
8 MB
Cores and Threads
4C / 8T
Chipset
Memory
Internal Storage
Intel® C224 Chipset
Type
DDR3-1600 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
32 GB (4 x 8 GB)
Standard Capacity
0 GB
Maximum Capacity
SATA HDD: 8 TB (8 x 1 TB)
SAS HDD : 9.6 TB (8 x 1.2 TB)
SAS SSD 3.2 TB (8 x 400 GB)
Disk Controller
SATA : 6 Gb/s (Integrated)
SAS : 6 Gb/s (Optional)
RAID
SATA : RAID 0/1/10 (Standard ), RAID 5/6/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
1
Expansion Slots
Video
Total: 2 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 2.0 x4 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1280 x 1024 / 16.7M
2
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
3 USB3.0 (1 front, 2 rear)
4 USB2.0 (1 front, 2 rear, 1 internal)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 100BASE-TX LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
Acoustic Noise
(Sound Pressure
3
Level)
NEC Corporation
(Max. Config, Idling)
127 VA
/ 118 Watt
(Max. Config,
Operating)
198 VA
/ 291 Watt
262 VA
/ 256 Watt
300 VA
/ 293 Watt
Minimum Config.
47.7 dB
44.4 dB
47.7 dB
Maximum Config.
46.8 dB
41.8 dB
46.8 dB
Revision 2.1 – January 16, 2014
5
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
1
2
3
4
5
Model
R110f-1E
Dimensions (W x D x H )
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 x86 Standard
Microsoft® Windows Server® 2008 x86 Enterprise
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
4
Microsoft® Windows Server® 2012 R2 Standard
4
Microsoft® Windows Server® 2012 R2 Datacenter
5
Red Hat Enterprise Linux 5.9 or later
5
Red Hat Enterprise Linux 5.9 or later (EM64T)
5
Red Hat Enterprise Linux 6.4 or later (x86)
5
Red Hat Enterprise Linux 6.4 or later (x86_64)
VMware ESXi 5.1 update 1
VMware ESXi 5.5
Embedded SATA RAID controller is supported only on limited operating systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the
operating environment.
For Windows Server 2012 R2 installation, download the driver kit from the following website and install
it after OS installation
http://www.nec.com/en/global/prod/express/download/
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
3.5-inch Drive Model
(1/2)
Model
R110f-1E
Part Number
N8100-1986F, N8100-1998F
Processor
Type
Intel® Pentium®
Processor G3220
Intel® Xeon®
Processor E3-1220
v3
Intel® Xeon®
Processor E3-1230L
v3
Clock Speed
3 GHz
3.10 GHz
1.80 GHz
Number of Processor
1
Cache
8 MB
Cores and Threads
2C / 2T
4C / 4T
4C / 8T
Chipset
Memory
Internal Storage
NEC Corporation
Intel® C224 Chipset
Type
DDR3-1600 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
32 GB (4 x 8 GB)
Standard Capacity
0 GB
Maximum Capacity
SATA : 16 TB (4 x 4 TB)
Disk Controller
SATA : 6Gb/s (Integrated)
RAID
SATA : RAID 0/1/10 (Standard ), RAID 5/6 (Optional)
1
Revision 2.1 – January 16, 2014
6
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Model
R110f-1E
Internal Storage
Hot Plug
Supported
(Continued)
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
Expansion Slots
Video
Total: 2 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 2.0 x4 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1280 x 1024 / 16.7M
2
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
3 USB3.0 (1 front, 2 rear)
4 USB2.0 (1 front, 2 rear, 1 internal)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 100BASE-TX LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
(Max. Config, Idling)
102 VA
/ 94 Watt
112 VA
/ 104 Watt
102 VA
/ 94 Watt
(Max. Config,
Operating)
214 VA
/207 Watt
277 VA
/ 270 Watt
206 VA
/ 197 Watt
Acoustic Noise
Minimum Config.
(Sound Pressure
Maximum Config.
3
Level)
Dimensions (W x D x H )
44.3 dB
47.7 dB
44.4 dB
34.8 dB
46.8 dB
41.8 dB
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 x86 Standard
Microsoft® Windows Server® 2008 x86 Enterprise
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
4
Microsoft® Windows Server® 2012 R2 Standard
4
Microsoft® Windows Server® 2012 R2 Datacenter
5
Red Hat Enterprise Linux 5.9 or later
5
Red Hat Enterprise Linux 5.9 or later (EM64T)
5
Red Hat Enterprise Linux 6.4 or later (x86)
5
Red Hat Enterprise Linux 6.4 or later (x86_64)
6
VMware ESXi 5.1 update 1
6
VMware ESXi 5.5
1
2
3
4
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Embedded SATA RAID controller is supported only on limited operating systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the
operating environment.
For Windows Server 2012 R2 installation, download the driver kit from the following website and
NEC Corporation
Revision 2.1 – January 16, 2014
7
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
5
6
install it after OS installation
http://www.nec.com/en/global/prod/express/download/
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
Support on Xeon processor systems only.
(2/2)
Model
R110f-1E
Part Number
Processor
N8100-1986F, N8100-1998F
Type
Intel® Xeon®
Processor E3-1230
v3
Intel® Xeon®
Processor E3-1265L
v3
Intel® Xeon®
Processor E3-1270
v3
Clock Speed
3.30 GHz
2.50 GHz
3.50 GHz
Number of Processor
1
Cache
8 MB
Cores and Threads
4C / 8T
Chipset
Memory
Internal Storage
Intel® C224 Chipset
Type
DDR3-1600 ECC Unbuffered DIMM
Standard Capacity
0 GB
Maximum Capacity
32 GB (4 x 8 GB)
Standard Capacity
0 GB
Maximum Capacity
SATA : 16 TB (4 x 4 TB)
Disk Controller
SATA : 6Gb/s (Integrated)
RAID
SATA : RAID 0/1/10 (Standard ), RAID 5/6 (Optional)
Hot Plug
Supported
Optical Disk Drive
Optional
Optical Drive Bays
1
Disk Drive Bays
4
1
Expansion Slots
Video
Total: 2 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 2.0 x4 (x8 connector)
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
1280 x 1024 / 16.7M
2
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
3 USB3.0 (1 front, 2 rear)
4 USB2.0 (1 front, 2 rear, 1 internal)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 100BASE-TX LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
Acoustic Noise
(Sound Pressure
3
Level)
NEC Corporation
(Max. Config, Idling)
112 VA
/ 104 Watt
102 VA
/ 94 Watt
117 VA
/ 108 Watt
(Max. Config,
Operating)
289 VA
/ 282 Watt
235 VA
/ 227 Watt
295 VA
/ 287 Watt
Minimum Config.
47.7 dB
44.4 dB
47.7 dB
Maximum Config.
46.8 dB
41.8 dB
46.8 dB
Revision 2.1 – January 16, 2014
8
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Model
R110f-1E
Dimensions (W x D x H )
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40 ° C / 50° to 104 ° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, UL, CB, RoHS, WEEE, BSMI, CCC, RCM
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 x86 Standard
Microsoft® Windows Server® 2008 x86 Enterprise
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
4
Microsoft® Windows Server® 2012 R2 Standard
4
Microsoft® Windows Server® 2012 R2 Datacenter
5
Red Hat Enterprise Linux 5.9 or later
5
Red Hat Enterprise Linux 5.9 or later (EM64T)
5
Red Hat Enterprise Linux 6.4 or later (x86)
5
Red Hat Enterprise Linux 6.4 or later (x86_64)
VMware ESXi 5.1 update 1
VMware ESXi 5.5
1
2
3
4
5
Embedded SATA RAID controller is supported only on limited operating systems.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the
operating environment.
For Windows Server 2012 R2 installation, download the driver kit from the following website and
install it after OS installation
http://www.nec.com/en/global/prod/express/download/
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/en/global/prod/express/linux/index.html
NEC Corporation
Revision 2.1 – January 16, 2014
9
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
External Views
Front and Rear Views
Front View for 2.5-inch Drive Model
C
D
E GI
K
M
N
F H J L
O
A
P
B
Front View for 3.5-inch Drive Model
C
D
E GI
K
M
N
B
F H J L
O
A
Legend
A.
Drive Bays
I.
UID LED
B.
Optical Drive Bay
J.
System Status LED
C.
USB 2.0 Connector
K.
BMC Reset Switch
D.
USB 3.0 Connector
L.
Dump (NMI) Switch
E.
Power LED
M.
UID LED Button
F.
Drive Activity LED
N.
Power Button
G.
Data LAN 1 Activity LED
O.
Pull-out Tab
H.
Data LAN 2 Activity LED
P.
Optional Drive Cage Bay
NEC Corporation
Revision 2.1 – January 16, 2014
10
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Rear View for Non-redundant PSU Configuration
L
J
M
K
I
C
D
F
G
A
B
E H
Rear View for Redundant PSU Configuration
L
L
M
M
J
K
I
C
D
F
G
A
B
E H
Legend
A.
PCI Slot (Low profile)
B.
H.
UID LED / Button
PCI Slot (Low profile)
I.
Power LED
C.
Data LAN 1 Connector
J.
Serial Port Connector
D.
Data LAN 2 Connector
K.
VGA Connector
E.
Management LAN Connector
L.
Power Unit
F.
USB 2.0 Connectors
M.
AC Inlet
G.
USB 3.0 Connectors
NEC Corporation
Revision 2.1 – January 16, 2014
11
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Dimensions (mm)
NEC Corporation
Revision 2.1 – January 16, 2014
12
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Configuration Diagram
2.5-inch Drive Model
Legend:
Mandatory Components
Standard Components
Mandatory Components
Standard Components
3.5-inch Drive Model
Legend:
NEC Corporation
Revision 2.1 – January 16, 2014
13
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Expansion Slots
PCI 1A
PCI 1B
Legend
#1A
PCIe 3.0 x8, x16 connector, Low profile, up to 173 mm length
#1B
PCIe 2.0 x4, x8 connector, Low profile, up to 173 mm length
NEC Corporation
Revision 2.1 – January 16, 2014
14
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800/R110f-1E
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no Front bezel
Including:
3.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD
NEC Express5800/R110f-1E
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no Front bezel
Including:
3.5-inch Drive Cage, 2 x 500 Watt hot plug power supply, EXPRESSBUILDER DVD
NEC Express5800/R110f-1E
No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no Front bezel
Including:
2.5-inch Drive Cage, 400 Watt non-hot plug power supply, EXPRESSBUILDER DVD
NEC Express5800/R110f-1E
No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no Front bezel
Including:
2.5-inch Drive Cage, 2 x 500 Watt hot plug power supply, EXPRESSBUILDER DVD
N8100-1986F
N8100-1998F
N8100-1999F
N8100-2000F
NOTE:

The base model must be ordered with a processor kit, a memory kit, a cooling fan kit, and internal
hard drive cable.
2 Processor
Available sockets: 1
Category
Product Name / Description
Part Number
Processors
Required
Pentium G3220 Processor Kit
Intel® Pentium ® Processor G3220 (3 GHz, 2C/2T, 3 MB)
Xeon E3-1220 v3 Processor Kit
Intel® Xeon ® Processor E3-1220 v3 (3.10 GHz, 4C/4T, 8 MB)
Xeon E3-1230L v3 Processor Kit
Intel® Xeon ® Processor E3-1230L v3 (1.80 GHz, 4C/8T, 8 MB)
Xeon E3-1230 v3 Processor Kit
Intel® Xeon ® Processor E3-1230 v3 (3.30 GHz, 4C/8T, 8 MB)
Xeon E3-1265L v3 Processor Kit
Intel® Xeon ® Processor E3-1265L v3 (2.50 GHz, 4C/8T, 8 MB)
Xeon E3-1270 v3 Processor Kit
Intel® Xeon ® Processor E3-1270 v3 (3.50 GHz, 4C/8T, 8 MB)
N8101-623F
N8101-626F
N8101-627F
N8101-628F
N8101-629F
N8101-639F
NOTE:

The processor kit must be ordered with the base model.

VMware ESXi is not supported on Pentium processor systems.
NEC Corporation
Revision 2.1 – January 16, 2014
15
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
3 Memory
Available slots: 4
Product Name / Description
Part Number
2GB DDR3-1600 UNB Memory Kit
2GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800)
4GB DDR3-1600 UNB Memory Kit
4GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800)
8GB DDR3-1600 UNB Memory Kit
8GB Unbuffered ECC DIMM, DDR3L-1600(PC3-12800)
N8102-523F
N8102-524F
N8102-525F
NOTE:



Minimum one memory kit must be installed.
To install by double of memory kit is recommended in order to increase memory transfer
speed by the dual-channel symmetric configuration.
Actual memory speed drops to 1333 MHz when you choose Pentium Processor.
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system
because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary
depending on the type and the number of PCI cards you are using.
Maximum Memory Size Supported by Operating Systems
4 GB
4 GB( HW-DEP enabled)
App. 3.5 GB (HW-DEP disabled)
32 GB
32 GB
64 GB
32 GB
2 TB
32 GB
Microsoft Windows Server 2012 Standard
1
Microsoft Windows Server 2012 Datacenter
1
Microsoft Windows Server 2012 R2 Standard
1
Microsoft Windows Server 2012 R2 Datacenter
4 TB
32 GB
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 6
16 GB
16 GB
Red Hat Enterprise Linux 5 (EM64T)
1 TB
32 GB
Red Hat Enterprise Linux 6 (x86_64)
3 TB
32 GB
VMware ESXi 5.1
2
2 TB
32 GB
VMware ESXi 5.5
2
4 TB
32 GB
Microsoft Windows Server 2008 Standard
Microsoft Windows Server 2008 R2 Standard
1
Microsoft Windows Server 2008 Enterprise
Microsoft Windows Server 2008 R2 Enterprise
1
1
1
Maximum Available Memory
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2008 R2 Standard : 32 GB
- Windows Server 2008 R2 Enterprise : 1TB
- Windows Server 2012, Windows Server 2012 R2 : 4 TB
2
Up to 1TB of main memory is available to each virtual machine.
NEC Corporation
Revision 2.1 – January 16, 2014
16
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4 Internal Hard Disk Drives
4.1
RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration.
4.1.1
Up to six 2.5-inch Drive
Available Interface
Non-RAID
Refer to 4.2.1
SATA
Refer to 4.2.2
SATA
No Cache
Refer to 4.2.3
SAS, SATA
512 MB Cache
Refer to 4.2.4
SAS, SATA
512 MB Cache
Refer to 4.2.5
SAS, SATA
1GB Cache/
Battery
Refer to 4.2.6
SAS, SATA
1GB Cache/
CacheCade
Refer to 4.2.7
SAS, SATA
Embedded SATA
RAID Controller
RAID 0/1/10
Optional RAID
Controller
RAID 5/6
4.1.2
Up to eight 2.5-inch Drive
Available Interface
RAID 0/1/10
RAID 5/6
No Cache
Refer to 4.2.8
SAS, SATA
512 MB Cache
Refer to 4.2.9
SAS, SATA
512 MB Cache
Refer to 4.2.10
SAS, SATA
1GB Cache/
Battery
Refer to 4.2.11
SAS, SATA
1GB Cache/
CacheCade
Refer to 4.2.12
SAS, SATA
NOTE:







Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS
Support Matrix for PCI Cards and Embedded Controllers.
Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller.
Internal optical drive cannot be installed when N8154-52 2.5-inch Hot Plug Drive Cage Kit is installed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
All drives within a RAID array should be of the same type, capacity and rotation speed.
All SAS hard drives within a system should be of the same rotation speed.
Mixing SAS and SATA hard drives in the same system is not supported.
NEC Corporation
Revision 2.1 – January 16, 2014
17
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.1.3
3.5-inch Drive
Available Interface
Non-RAID
Refer to 4.3.1
SATA
Refer to 4.3.2
SATA
No Cache
Refer to 4.3.3
SATA
512 MB Cache
Refer to 4.3.4
SATA
512 MB Cache
Refer to 4.3.5
SATA
1GB Cache/
Battery
Refer to 4.3.6
SATA
1GB Cache/
CacheVault
Refer to 4.3.7
SATA
Embedded SATA
RAID Controller
RAID 0/1/10
Optional RAID
Controller
RAID 5/6
NOTE:



Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS
Support Matrix for PCI Cards and Embedded Controllers.
Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller.
All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 2.1 – January 16, 2014
18
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2
2.5-inch Drive Configuration
4.2.1
Up to four Drives with Embedded SATA non-RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA
Internal SAS/SATA Cable
MiniSAS-4x Single SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
(Standard)
Cable
Required
Drive Cage
Drive
4 slots
available
SATA
HDD
K410-289(00)
(Standard)
N8150-356
N8150-357
N8150-358
NOTE:

Hot plug insertion/removal is not supported with the Embedded SATA non-RAID controller.
4.2.2
Up to four Drives with Embedded SATA RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
Internal SATA Cable
miniSAS to 4x Single-SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
(Standard)
Cable
Drive Cage
Drive
4 slots
available
SATA
K410-289(00)
(Standard)
N8150-356
N8150-357
N8150-358
NOTE

Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS
Support Matrix for PCI Cards and Embedded Controllers.

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 2.1 – January 16, 2014
19
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.3
Up to six Drives with RAID 0/1 Controller without Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0MB, RAID 0/1)
LSI MegaRAID SAS 9240-8i
RAID0/1/10, Cache less, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8103-171
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-322
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
K410-240(00)
K410-204(00)
(Standard)
N8150-301
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
20
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.4
Up to six Drives with RAID 0/1 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/10, 512MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8103-149
RAID BBU
Recommended
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
K410-240(00)
K410-204(00)
(Standard)
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
21
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.5
Up to six Drives with RAID 5/6 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8103-150
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-322
RAID BBU
Recommended
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
K410-240(00)
K410-204(00)
(Standard)
N8150-301
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
22
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.6
Up to six Drives with RAID 5/6 Controller with 1 GB Cache/Battery
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-151
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
K410-240(00)
RAID BBU
Recommended
SSD Caching
Recommended
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
N8103-156
K410-204(00)
(Standard)
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
23
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.7
Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i(with CV)
RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8),
6Gb/s, flash cache protection modules included
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-152
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
K410-240(00)
SSD Caching
Recommended
Cable
Required
Cable
Drive Cage
Drive
4 to 6 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-156
K410-204(00)
(Standard)
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
24
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.8
Up to eight Drives with RAID 0/1 Controller without Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0MB, RAID 0/1)
LSI MegaRAID SAS 9240-8i
RAID 0/1/10, Cache less, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage Kit
2 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8103-171
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-322
Cable
Required
Cable
Required
Drive Cage
Drive Cage
Required
Drive
8 slots
available
SAS
HDD
SATA
HDD
K410-240(00)
K410-204(00)
(Standard)
N8154-52F
N8150-301
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
25
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.9
Up to eight Drives with RAID 0/1 Controller with 512 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID 0/1/10, 512MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA, for 5th and 6th hard drives
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage Kit
2 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8103-149
RAID BBU
Recommended
Cable
Required
Cable
Required
Drive Cage
Drive Cage
Required
Drive
8 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
K410-240(00)
K410-204(00)
(Standard)
N8154-52F
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
26
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.10 Up to eight Drives with RAID 5/6 Controller with 512 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage Kit
2 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8103-150
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-322
RAID BBU
Recommended
Cable
Required
Cable
Required
Drive Cage
Drive Cage
Required
Drive
8 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
K410-240(00)
K410-204(00)
(Standard)
N8154-52F
N8150-301
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
27
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.11 Up to eight Drives with RAID 5/6 Controller with 1 GB Cache/Battery
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-151
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage Kit
2 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
K410-240(00)
RAID BBU
Recommended
SSD Caching
Recommended
Cable
Required
Cable
Required
Drive Cage
Drive Cage
Required
Drive
8 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-154
N8103-156
K410-204(00)
(Standard)
N8154-52F
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
28
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.2.12 Up to eight Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60,
1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache
protection modules included
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-152
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
2.5-inch Drive Cage
6 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage Kit
2 x 2.5-inch hot plug drive bays
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
K410-240(00)
SSD Caching
Recommended
Cable
Required
Cable
Required
Drive Cage
Drive Cage
Required
Drive
8 slots
available
SAS
HDD
SATA
HDD
SAS
SSD
N8103-156
K410-204(00)
(Standard)
N8154-52F
N8150-301
N8150-322
N8150-304
N8150-332
N8150-408
N8150-303
N8150-331
N8150-356
N8150-357
N8150-358
N8150-711
N8150-712
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation
Revision 2.1 – January 16, 2014
29
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.3
3.5-inch Drive Configuration
4.3.1
Embedded SATA non-RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
MiniSAS, 6Gb/s SATA
Internal SAS/SATA Cable
MiniSAS to 4x Single-SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
(Standard)
Cable
Required
Drive Cage
Drive
4 slots available
K410-288(00)
(Standard)
N8150-363
N8150-364
N8150-354
NOTE

Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.2
Embedded SATA RAID Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, 6Gb/s SATA
Internal SAS/SATA Cable
(Standard)
Cable
Required
Drive Cage
Drive
4 slots available
K410-288(00)
MiniSAS to 4x Single-SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS
Support Matrix for PCI Cards and Embedded Controllers.

Embedded SATA RAID Controller does not support RAID 10 configured with 2TB or more HDDs.

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 2.1 – January 16, 2014
30
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.3.3
RAID 0/1 Controller with 0 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0MB, RAID 0/1)
LSI MegaRAID SAS 9240-8i
RAID0/1/10, Cache less, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-171
Cable
Required
Drive Cage
Drive
4 slots available
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
NOTE:

All hard drives within a RAID array should be of the same capacity.
4.3.4
RAID 0/1 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID 0/1, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-149
RAID BBU
Recommended
Cable
Required
Drive Cage
Drive
4 slots available
N8103-154
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 2.1 – January 16, 2014
31
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.3.5
RAID 5/6 Controller with 512 MB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-150
RAID BBU
Recommended
Cable
Required
Drive Cage
Drive
4 slots available
N8103-154
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
4.3.6
RAID 5/6 Controller with 1 GB Cache/Battery
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-151
RAID BBU
Recommended
Cable
Required
Drive Cage
Drive
4 slots available
N8103-154
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
NEC Corporation
Revision 2.1 – January 16, 2014
32
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
4.3.7
RAID 5/6 Controller with 1 GB Cache/CacheVault
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i(with CV) RAID0/1/5/6/10/50/60,
1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache
protection modules included
Internal SAS Cable
1x Mini-SAS to 4x Single SATA
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8103-152
Cable
Required
Drive Cage
Drive
4 slots available
K410-240(00)
(Standard)
N8150-363
N8150-364
N8150-354
N8150-355
N8150-395
NOTE:

All hard drives within a RAID array should be of the same capacity.
5 Optical Drive
Category
Product Name / Description
Part Number
Internal
1 slot available
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
External DVD-ROM drive
DVD-ROM drive, Bus powered, 1.2 A required
N8151-119
External
N8151-107F
N8160-91
NOTE:


Up to 1 optical drive can be connected.
N8154-52 2.5-inch Hot Plug Drive Cage Kit cannot be installed when an internal optical drive is
installed.
NEC Corporation
Revision 2.1 – January 16, 2014
33
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
6 PCI Card
Please refer to Supported PCI cards and Installable Slots with regard to the position of PCI slot which
can mount PCI card supported.
6.1
Network Interface Controller
Category
Adapter
GbE
10GbE
SPF+
Module
NEC Corporation
Product Name / Description
Part Number
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Intel® 82580 Gigabit Ethernet Controller
PCIe 2.0 x4
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-138
10GBASE Adapter (SFP+/2ch)
Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port
Network Interface Card
PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical
cable.
- Up to 2 SFP+ Modules can be installed.
- Supports either 10Gb Converged Network Adapter or 10Gb
Network Adapter in RHEL 6 operating systems.
N8104-128
Dual Port 10Gb Converged Network Adapter
BROCADE 1020 Dual Port 10Gbps Converged Network Adapter
PCIe 2.0 x8, 2 x SFP modules, Max. one adapter
NOTE:
- Supports either 10Gb Converged Network Adapter or 10Gb
Network Adapter in RHEL 6 operating systems.
N8104-131
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-128
N8104-129
Revision 2.1 – January 16, 2014
N8104-132
N8104-145
N8104-133
34
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
NIC Teaming feature - NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming
while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS.
Network Interface
Team
Operating Systems
1GbE NIC
Embedded 1GbE NIC/N8104-138/-132/-133
Up to four teams per one system
Up to four ports per one team
Windows Server 2008
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
RHEL5.9* or later
RHEL6.4* or later
1GbE NIC
N8104-145
Up to four teams per one system
Up to four ports per one team
Windows Server 2008
Windows Server 2008 R2
10GbE NIC
N8104-128
Up to two teams per one system
Up to two ports per one team
Windows Server 2008
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
RHEL5.9(EM64T)* or later
RHEL6.4(x86_64)* or later
* RHEL : Red Hat Enterprise Linux
NOTE:

Teaming feature is not supported on iSCSI interfaces.

The network interfaces for teaming must be the same.

When 10GbE and 1GbE LAN teams are mixed, the teams must be up to four per one system.
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Category
Network Interface
Operating Systems
1GbE
Embedded 1GbE NIC
Windows Server 2008 R2, Windows Server 2012, RHEL, VMware
N8104-138
Windows Server 2008 R2, Windows Server 2012, RHEL, VMware
N8104-132
Windows Server 2008 R2, Windows Server 2012, RHEL, VMware
N8104-133
Windows Server 2008 R2, Windows Server 2012, RHEL, VMware
N8104-128
Windows Server 2008 / Windows Server 2008R2 / Windows Server 2012 /
RHEL* / VMware
10GbE
* RHEL : Red Hat Enterprise Linux
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.
NEC Corporation
Revision 2.1 – January 16, 2014
35
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
6.2
InfiniBand
Category
Product Name / Description
Part Number
Controller
Single Port InfiniBand Adapter
Mellanox ConnectX-3 VPI, MCX353A-FCBT,
FDR, PCIe 3.0(x8)
Dual Port InfiniBand Adapter
Mellanox ConnectX-3 VPI, MCX354A-FCBT,
FDR, PCIe 3.0(x8)
InfiniBand Cable 2m/FRD
Copper
InfiniBand Cable 3m/FDR
Copper
InfiniBand Switch 36 ports/FDR
Mellanox MSX6036F-1SFR
36 ports, FDR, One power supply module included, no power
cord
Redundant Power Supply Unit
Power supply module for 36 ports InfiniBand switch, no power
cord
N8104-146
Cable
Switch
Unit
Power
Supply
N8104-147
K410-304(02)
K410-304(03)
NE3707-061
NE3707-063
NOTE:

The InfiniBand adapters and other options are make-to-order products. Please consult our sales
representative in regards to production lead time.
6.3
External Storage Controller
6.3.1
RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (512MB, RAID0/1/5/6)
LSI MegaRAID SAS 9285-8e
RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9285-8e
N8103-160
RAID BBU
N8103-162
NOTE:

To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.

It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
NEC Corporation
Revision 2.1 – January 16, 2014
36
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
6.3.2
Fibre Channel / SAS Controller
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (1ch)
Emulex LightPulse LPe16000B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- One controller can be installed on Pentium processor
systems.
Fibre Channel Controller (2ch)
Emulex LightPulse LPe16002B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is supported only with Xeon processor.
N8190-153
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
N8103-142
SAS
N8190-154
N8190-157
N8190-158
NOTE:

Mixing 8Gb fibre channel controllers and 16Gb fibre channel controllers in the same system is not
supported.
6.4
Serial Port Adapter
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
N8117-01A
NOTE:

Up to one Serial Port Adapter can be installed.
NEC Corporation
Revision 2.1 – January 16, 2014
37
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
7 Other Add-in Components
7.1
Cooling Fan Kit
Product Name / Description
Part Number
Redundant Fan Kit
Non-hot plug cooling fan for R110f-1E
Non-redundant Fan Kit
Non-hot plug cooling fan for R110f-1E
N8181-111F
N8181-115F
NOTE:

One of the fan kits must be installed.
7.2
Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 1.2 module
N8115-15
NOTE:

The kit is not available in China.

The kit is not removable after attachment.

"TPM Support" in BIOS setup menu must be activated prior to use of this kit.

To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker
function. The recovery password is required to restore data for hardware replacement during a
system error.
7.3
Internal Flash Memory
Available socket: 1
Product Name / Description
Part Number
Internal Flash Memory
Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without
DVD media
NOTE:
Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the
flash memory.
The following operations can be performed with the flash memory:
- Installation of Windows server with express setup
- Installation of Starter Pack—the package of NEC qualified drivers and system setting
tools
- Installation of NEC ESMPRO Agent and Universal RAID Utility
- Performance of the Test and Diagnosis Tool
N8115-14
7.4
Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
NOTE:

Up to one drive can be connected.
NEC Corporation
Revision 2.1 – January 16, 2014
38
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
7.5
Front Bezel
Product Name / Description
Part Number
Front Bezel
Front bezel for R110f-1E
N8146-38F
NEC Corporation
Revision 2.1 – January 16, 2014
39
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
8 Add-on Components
8.1
17-inch LCD Console Drawer
Category
Drawer
Drawer
w/ KVM
Cable
Drawer
Drawer
w/o KVM
Keypad
8.2
Product Name / Description
Part Number
17-inch LCD Console Drawer (8 port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port
KVM switch, 1U height
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1 port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad
with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8
m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD
Console Drawer (1 port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD
Console Drawer (1 port)
N8143-77F
K410-118(1A)
K410-118(03)
K410-118(05)
N8143-76F
N8143-84F
N8143-85
N8143-87
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
N8191-12F
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-118(1A)
Cable
KVM
Cascading
NEC Corporation
Revision 2.1 – January 16, 2014
K410-118(03)
K410-118(05)
K410-119(1A)
40
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
8.3
Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
Product Name / Description
Part Number
Remote KVM and Media License kit
N8115-04
License for one server.
Remote console and remote media are enabled regardless of OS status.
Remote KVM:
Displays a graphics console on the web browser of the remote terminal
(PC/server).
Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
NOTE:

Remote KVM and remote media features are not available for virtual machines.
8.4
Dust Proof Filter Kit
The server supports the dust resistant feature. Choose the following kit to install the system in dusty
places.
Product Name / Description
Part Number
Dust Proof Filter
10 sheets, dust proof filter for R110f-1E
N8147-07
NOTE:

The filter kit is make-to-order product. Please consult our sales representative in regards to
production lead time.
NEC Corporation
Revision 2.1 – January 16, 2014
41
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
References
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
Temperature/fan/voltage/power
consumption/SystemLAN/degeneration(memory)


Hardware configuration information collection


Hardware event log collection


Boot monitoring
BIOS/POST stall, Booting, OS stall, shutdown
Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)
Remote KVM
(via LAN)
POST/BIOS setup, ROM utility
Remote control
(via LAN)
4
2


1


1,3

CUI-based screen (OS console)

1,4

GUI-based screen (OS console)
-

Remote KVM Video Record
-

Remote reset/power on-off/ dump


Remote Power Capping


BIOS/BMC FW update


Remote BIOS setup(partial configuration only)



2

2
Remote media (CD/DVD/FD/USB)
-

CLP (Command Line Protocol) (DMTF compliant)


Remote control via Web browser (multi user login
at the same time)



2

2
Maintenance
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)


Others
Set automatic IP address via DNS/DHCP


LDAP/Active Directory verification/user control


Clock synchronization of main unit and the RTC


Access log collection


Industry
Standard
3


Scheduling (without UPS, require NEC ESMPRO
Manager)
2

2
Panic screen, Boot screen
OS shutdown
1
With Remote KVM
and Media License
kit
IPMI support
2.0
2.0
The optional serial port is not available for the feature
The feature is not supported on VMware systems
Monitoring boot screens is not supported on VMware systems.
In VMware systems, only the direct console user interface is supported.
NEC Corporation
Revision 2.1 – January 16, 2014
42
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
OS Support Matrix for PCI Cards and Embedded Controllers
ESXi 5.1
ESXi 5.5
RHEL 5 x64
RHEL 5
RHEL 6 x64
RHEL 6
WS 2008
WS 2008 R2
WS 2012
WS 2012 R2
Part Number
Product Name
-
Embedded SATA non-RAID Controller

-
Embedded SATA RAID Controller
 -
-
Embedded 1GbE NIC

N8103-142
SAS Controller
-
N8103-171
RAID Controller (0MB, RAID 0/1)
 -
N8103-149
RAID controller (512MB, RAID 0/1)

N8103-150
RAID controller (512MB, RAID 0/1/5/6)

N8103-151
RAID controller (1GB, RAID 0/1/5/6)

N8103-152
RAID controller (1GB, RAID 0/1/5/6)

N8103-160
RAID controller (1GB, RAID 0/1/5/6)

N8190-153
Fibre Channel Controller

N8190-154
Fibre Channel Controller (2ch)

N8190-157
Fibre Channel Controller
 -
-
 -
-
 -
N8190-158
Fibre Channel Controller (2ch)
 -
-
 -
-
 -
N8104-138
1000BASE-T Adapter (1ch)

N8104-132
Dual Port 1000BASE-T Adapter

N8104-145
Dual Port 1000BASE-T Adapter
-
N8104-133
Quad Port 1000BASE-T Adapter

N8104-128
10GBASE Adapter (SFP+/2ch)

N8104-131
Dual Port 10Gb Converged Network Adapter
-
-
-
 -
-
-
 -
-
N8104-146
N8104-147
NEC Corporation
Single Port InfiniBand Adapter
Dual Port InfiniBand Adapter
-
-
-
-
 -

-

Revision 2.1 – January 16, 2014
 -
-
-
 -
-
-
-
-
 -
-
-
-
43
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Supported PCI cards and Installable Slots
Slots
Part Number
Product Name
#1
#2
N8103-142
SAS Controller


N8103-171
RAID Controller (0MB, RAID 0/1)
-

N8103-149
RAID Controller (512MB,RAID 0/1)
-

N8103-150
RAID Controller (512MB,RAID 0/1/5/6)
-

N8103-151
RAID Controller (1GB,RAID 0/1/5/6)
-

N8103-152
RAID Controller (1GB,RAID 0/1/5/6)
-

N8103-160
RAID Controller (1GB,RAID 0/1/5/6)


N8190-153
Fibre Channel Controller


N8190-154
Fibre Channel Controller (2ch)


N8190-157
Fibre Channel Controller


N8190-158
Fibre Channel Controller (2ch)


N8104-138
1000BASE-T Adapter (1ch)


N8104-132
1000BASE-T Adapter (2ch)


N8104-145
1000BASE-T Adapter (2ch)


N8104-128
10GBASE Adapter (SFP+/2ch)


N8104-131
Dual Port 10Gb Converged Network Adapter


N8104-146
Single Port InfiniBand Adapter

-
N8104-147
Dual Port InfiniBand Adapter

-
N8117-01A
Serial Port Adapter


NEC Corporation
Revision 2.1 – January 16, 2014
44
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 2.1 – January 16, 2014
45
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R110f-1E
Revision History
Revision
Date
Description
2.1
January 16, 2014
Others:
Add Windows Server 2012 R2 to the list of operating system supported
Update OS support matrix
2.0
October 25, 2013
New products added:
Pentium G3220 Processor Kit / N8101-623F
Single Port InfiniBand Adapter / N8104-146
Dual Port InfiniBand Adapter / N8104-147
InfiniBand Cable 2m/FRD / K410-304(02)
InfiniBand Cable 3m/FRD / K410-304(03)
InfiniBand Switch 36 ports/FDR / NE3707-061
Redundant Power Supply Unit / NE3707-063
Others:
Add N8104-133 Quad Port 1000BASE-T Adapter to the support list
Add VMware ESXi 5.5 to the list of operating system supported
Update OS support matrix
1.0
July 17, 2013
Initial release
NEC Corporation
Revision 2.1 – January 16, 2014
46