PCD - Picker Components

FEATURES
PART NUMBER
Input Voltage
Maximum
Trigger
Current
Maximum
Output
Currnet
Maximum
Output
Voltage
Minimum
Output
Voltage
Zero
Cross
PCD210AC8-X
4-32 VDC
10 mA
10 Amps
250 VAC
50 VAC
Y
PCD215AC8-X
4-32 VDC
25 mA
15 Amps
250VAC
50 VAC
Y
PCD225AC8-X
4-32 VDC
25 mA
25 Amps
250 VAC
50 VAC
Y
PCD240AC8-X
4-32 VDC
25 mA
40 Amps
250 VAC
50 VAC
Y
PCD425AC8-X
4-32 VDC
25 mA
25 Amps
480 VAC
75 VAC
Y
PCD440AC8-X
4-32 VDC
25 mA
40 Amps
480 VAC
75 VAC
Y
Note: -X denotes Lead Free
PCD210-440 Rev A 6-6-02
PAGE 1
PCD
PCD
Absolute Maximum Ratings at 25 Degrees C
Output
Input
Parameter
Symbol
Rating
Unit
IN
4-32
V DC
1
V DC
10, 15, 25, or 40
A rms
10x I T
A
600 *See note 2
V
47 - 70
Hz
Input signal voltage
V
Drop out voltage
V
do
RMS on state current
I
T
Peak one cycle surge current
I
surge
Repetitive peak off state voltage
V
Operating frequency
f
Critical rate of rise on state current
di/dt
Load supply voltage
V
out
Isolation voltage input to output
V
Operating temperature
T
Storage temperature
T
Soldering temperature 10 seconds
T
DRM
A/
50
S
250 *See Note 2
Vrms AC
iso
4000
Vrms
opr
-30 - 100
o
stg
-30 - 125
o
sol
260
o
C
C
C
Electrical Characteristics at 25 Degrees C
Symbol
Output
Input
Parameter
Conditions
Unit
Pick up voltage
V
pu
It=1Arms
Input current
I
in
Vin=4 - 32V
5 TO 12 mA
1.5V rms MAX
50 mArms MIN
On state voltage
V
T
It=1Arms
Operating current
I
op
Vout=240 Vrms
Leakage current
I
leak
Vout=240 Vrms
Critical rate of rise of off state voltage
dv/dt
See Note 1
Zero cross voltage
V
ox
I in =7mA
Load voltage rating
V
out
I T =50mArms MIN
Minimum trigger current
I
FT
Isolation resistance input to circuit
R
Turn on time
Turn off time
Thermal resistance (between junction and case)
4V DC MAX
3.5 TO 7 mArms
50 TO 200V/
V DRM =600V
S
35 VAC MAX
50 TO 280VAC
25 mA MAX
10
iso
DC 500V
10 OHMS MIN
T
on
60Hz AC
8.3 ms MAX
T
off
60Hz AC
8.3 ms MAX
Rth(j-c)I
1.3 oC/W
NOTES: 1. Output (dv/dt) protection is provided on all models. They are designed to switch
resistive or inductive loads to 0.2 power factor. The dv/dt rating is based on a
source impedance of 50 ohms.
2. Model PCD425AC8-1 is rated 25 amps at 480 VAC. I surge is 250 amps and V DRM
Is 1200 VOLTS. Vout Is 480 VAC.
Model PCD440AC8-1 is rated 40 amps at 480 VAC. I surge is 400 amps and V DRM
Is 1200 VOLTS. Vout Is 480 VAC.
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888) 997-3933, (972) 713-6272 Fax: (972) 735-0964 email: [email protected] www.pickercomponents.com
PAGE 2
PCD
PCD
CHARACTERISTIC CURVES
RMS On-state Current vs.
Ambient Temperature
Surge Current vs. Time
Surge Current (A)
f=60hZ
o
Tj=25 C
RMS On State Current (A)
50
45
40
35
30
25
20
600
550
500
450
400
350
300
250
200
150
100
15
10
5
0
-30 0 10 20 30 40 50 60 70 80 90 100 110
0.01
o
Ambient temperature,Ta C
0.1
1
10
Time (SEC)
Open Circuit Leak Current vs.
Supply Voltage
RMS On-state Current vs.
Case Temperature
o
10
50
9
45
RMS On-state Current (A)
Open Circuit Leak Current (mA rms)
Ta=25 C
8
7
6
5
4
3
2
1
0
40
80
120
160
200
40
35
30
25
20
15
10
5
0
-30 0 10 20 30 40 50 60 70 80 90 100 110
240
o
Case temperature,Tc C
Supply Voltage (Vrms)
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888) 997-3933, (972) 713-6272 Fax: (972) 735-0964 email: [email protected] www.pickercomponents.com
PAGE 3
PCD
PCD
CHARACTERISTIC CURVES
Input Current vs.
Input Voltage
5
100
4.5
90
4
80
Input Current (mA)
Input Voltage (V)
Input Voltage vs.
Ambient Temperature
3.5
3
2.5
2
1.5
1
70
60
50
40
30
20
10
0.5
0
0
-30
0
20
40
60
80
10
100
o
20
30
40
50
60
Input Voltage (VDC)
Ambient Temperature Ta ( C)
Dimensions in Inches
1
1.85
LOAD
25 AMP
250VAC
2
PICKER CMPTS
SOLID STATE RELAY
TYPE PCD225AC8
INPUT 4-32 VDC
+3
4-
2.275
LED
.800
1.775
STANDARD
SNAP ON
SAFETY COVER
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888) 997-3933, (972) 713-6272 Fax: (972) 735-0964 email: [email protected] www.pickercomponents.com
PAGE 4