PCD203AC2 Data Sheet

Printed Circuit Board Solid State Relay
PCD203AC2
FEATURES
Narrow profile for high density spacing
Solid Epoxy Body Resistant to the environment
4,000 Volt isolation between input and output
4 to 24 Volt DC input
Completely sealed, Immersion cleanable
3 Amp AC Output
50 to 250 AC Volt Output
Zero crossing switching
Built in snubber network
Very high surge resistance
Dimensions in Inches
Drawing is 2 X Scale
1.45
.355
PICKER COMPONENTS
LOAD 3 A 250 VAC
INPUT 4 TO 24 VDC
P/N PCD 203AC2
INPUT
LOAD
+ -
.945
.400
.020
.177
.377
.877
1.277
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888)997-3933 Fax: (818) 342-5296 email: [email protected] URL: pickercomponents.com
PCD203AC2 Rev A 6-6-02
PAGE 1
PCD203AC2
PCD203AC2
Absolute Maximum Ratings at 25 Degrees C
Output
Input
Parameter
Symbol
Rating
Unit
Input signal voltage
V
IN
4 - 24
V DC
Drop out voltage
V
do
1
V DC
RMS on state current
I
T
3
A rms
Peak one cycle surge current
I
surge
30
A
600
V
47 - 70
Hz
Repetitive peak off state voltage
V
Operating frequency
f
Critical rate of rise on state current
di/dt
50
Load supply voltage
V
out
250
Vrms AC
Isolation voltage input to output
V
iso
4000
Vrms
Operating temperature
T
opr
-30 - 100
o
Storage temperature
T
-30 - 125
o
stg
260
o
T
Soldering temperature 10 seconds
DRM
sol
A/
S
C
C
C
Electrical Characteristics at 25 Degrees C
Output
Input
Parameter
Symbol
Conditions
Unit
4V DC MAX
Pick up voltage
V
pu
It = 1Arms
Input current
I
in
V in = 4 - 24V
5 TO 12 mA
On state voltage
V
T
It = 1Arms
1.5V rms MAX
Operating current
I
op
V out = 240 Vrms
50 mArms MIN
Leakage current
I
leak
V out = 240 Vrms
7 mArms MAX
Critical rate of rise of off state voltage
dv/dt
See Note 1
= 7mA
50 TO 200V/
35 VAC MAX
Zero cross voltage
V
ox
Load voltage rating
V
out
Minimum trigger current
I
FT
V DRM = 600 V
Isolation resistance input to circuit
R
iso
DC 500 V
10 OHMS MIN
Turn on time
T
on
60 Hz AC
8.3 ms MAX
Turn off time
T
off
60 Hz AC
8.3 ms MAX
Thermal resistance (between junction and case)
Rth(j-c)I
I
in
I T = 50 mArms Min.
S
50 TO 280VAC
10 mA MAX
10
1.3 oC/W
NOTES: 1. Output (dv/dt) protection is provided on all models. They are designed to switch
resistive or inductive loads to 0.2 power factor. The dv/dt rating is based on a
source impedance of 50 ohms.
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888)997-3933 Fax: (818) 342-5296 email: [email protected] URL: pickercomponents.com
PAGE 2
PCD203AC2
PCD203AC2
CHARACTERISTIC CURVES
RMS On-state Current vs.
Ambient Temperature
Surge Current vs. Time
f=60hZ
o
Tj=25 C
Surge Current (A)
RMS On-state Current (A)
5
4.5
4
3.5
3
2.5
2
50
45
40
35
30
25
20
15
1.5
1
0.5
0
-30 0 10 20 30 40 50 60 70 80 90 100 110
0.01
0.1
1
10
o
Ambient temperature,Ta C
Time (SEC)
Open Circuit Leak Current vs.
Supply Voltage
RMS On-state Current vs.
Case Temperature
o
10
5
9
RMS On-state Current (A)
Open Circuit Leak Current (mA rms)
Ta=25 C
8
7
6
5
4
3
2
1
0
40
80
120
160
200
4
3
2
1
0
-30 0 10 20 30 40 50 60 70 80 90 100 110
240
o
Case temperature,Tc C
Supply Voltage (Vrms)
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888)997-3933 Fax: (818) 342-5296 email: [email protected] URL: pickercomponents.com
PAGE 3
PCD203AC2
PCD203AC2
CHARACTERISTIC CURVES
Input Current vs.
Input Voltage
5
50
4.5
45
4
40
Input Current (mA)
Input Voltage (V)
Input Voltage vs.
Ambient Temperature
3.5
3
2.5
2
1.5
1
0.5
35
30
25
20
15
10
5
0
0
-30
0
20
40
60
80
10
100
o
Ambient Temperature Ta ( C)
20
30
40
50
60
Input Voltage (VDC)
NOTES:
3 AMP Rating is UL recognized and certified for Canada at 50 degrees C.
This SSR will carry up to 5 Amps at 30 Degrees C non UL.
Zero Crossing switching and 4,000 volt isolation make this relay CE compliant
.355 Inch thickness allows high density spacing
3220 Commander Drive, Suite 102, Carrollton, Texas 75006
Sales: (888)997-3933 Fax: (818) 342-5296 email: [email protected] URL: pickercomponents.com
PAGE 4