High Frequency Millimeter-wave Amplifier

Model # BXHF1200
High Frequency Millimeter-wave Amplifier
Frequency Range: 35 GHz to 45 GHz
Features
• Millimeter Wave Operation
• Laser Sealed Housing
• Internal Voltage Regulation
• Dual Stage Amplifier
The Model BXHF1200 is standard high frequency amplifier covering 35 GHz to 45 GHz. This two stage design, utilizes a
laser sealed housing for the ultimate in environmental protection. This standard design may also be ordered in a
screened MIL-STD-883 version as a model SXHF1200. All specification ratings are based on measurements in a 50 ohm
system with a DC supply voltage tolerance of +/- 2%.
Technical Specifications
Maximum (No Damage) Ratings
Parameter
Parameter
Unit
Typical
Min/Max
Frequency Range
GHz
35 - 45
35 - 45
Storage Temperature
-55°C to +85°C
Gain
dB
34
30 Min.
Operating Temperature
-40°C to +85°C
Noise Figure
dB
5.0
6.0 Max.
DC Voltage @ 25°C
Output Power @ 1 dB
Compression
dBm
+17
+15 Min.
Input Drive @ 25°C (CW)
Output 3rd Order Intercept
dBm
+27
---
Output 2nd Order Intercept
dBm
+37
---
Reverse Isolation
dB
50
---
Input VSWR
---
1.75:1
2.0:1 Max.
Output VSWR
---
1.75:1
2.0:1 Max.
Supply Voltage
volts
+12 to +15
+12 to +15
Supply Current
mA
300
325
Unit
+18 volts
-5 dBm
* Typical values are measured at 25°C,
but not guaranteed.
Mechanical & Electrical
Parameter
Specification
Housing Size
1.500” L x 1.060” W x 0.300” H
Housing Drawing
HF2
RF Connectors
2.92 mm Female Replaceable Connectors
Rev Date: 9/25/2015
© API Technologies Corp. Proprietary Information
Page # 1
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
Model # BXHF1200
Typical Performance Graphs
Gain (dB)
8
39
7.5
38
7
Noise (dB)
40
37
Gain (dB)
36
6.5
6
35
5.5
34
5
33
4.5
32
4
31
3.5
30
3
35
37
39
41
43
Noise Figure (dB)
35
45
37
Frequency (GHz)
1 dB Compression (dBm)
20
43
45
43
45
80
18
70
17
60
Rev. Isolation (dB)
1 dB Comp. (dBm)
41
Frequency (GHz)
Reverse Isolation (dB)
19
16
15
14
13
12
50
40
30
20
11
10
10
35
37
39
41
43
Frequency (GHz)
35
45
37
Input VSWR
2
39
41
Frequency (GHz)
Output VSWR
2
1.9
1.9
Output VSWR
1.8
Input VSWR
39
1.7
1.6
1.5
1.4
1.8
1.7
1.6
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1
1
35
37
39
41
43
45
35
37
Frequency (GHz)
39
41
Frequency (GHz)
Rev Date: 9/25/2015
© API Technologies Corp. Proprietary Information
43
Page # 2
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
45
Model # BXHF1200
Instructions
Grounding Instructions
Care should be taken to effectively ground each unit.
Revisions
API reserves the right to make revisions to both product and/or the information contained within their
datasheets without advanced notice.
Min./Max. Values
Specifications are guaranteed when tested in a 50 Ω (ohm) system.
Typical performance graphs and values are measured at 25°C, but not guaranteed.
Outline Drawing
Rev Date: 9/25/2015
© API Technologies Corp. Proprietary Information
Page # 3
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]