bxhf1203.pdf

Model # BXHF1203
High Frequency Microwave Amplifier
Frequency Range: 2-18 GHz
Features
• High Frequency and Broad Bandwidth: 2-18 GHz
• Low Noise Figure: 3.5 dB Typical
• Internal Voltage Regulator
• Low Phase Noise Performance
• EAR99 and RoHS Compliant
Model BXHF1203 is a high frequency amplifier covering 2-18 GHz. This design utilizes a laser sealed housing
for superior environmental protection. This standard design may also be ordered in a screened MIL-STD-883
version (Model #SXHF1203) All specification ratings are based on measurements in a 50 Ω (ohm) system with
a DC supply voltage tolerance of +/- 2%.
Technical Specifications
Maximum Ratings
Parameter
Unit
Typical
Min/Max
Frequency Range
GHz
2 to 18
2 to 18
Gain
dB
46
Noise Figure
dB
Output Power @ 1 dB
Compression**
Output 3rd Order Intercept
Maximum (No Damage) Ratings
Storage Temperature
-55°C to +85°C
43
Operating Temperature
-40°C to +85°C
3.5
5.0
DC Voltage @ 25°C
+18 volts
dBm
28
25
Input Drive @ 25°C (CW)
+13 dBm
dBm
32
-
Reverse Isolation
dB
65
-
Input VSWR
---
1.5:1
2.0:1
Output VSWR
---
1.5:1
2.0:1
Supply Voltage
volts
+15
+15
Supply Current
mA
650
700
•
Typical values are measured at 25°C,
but not guaranteed.
•
Min/Max values are guaranteed from
-20°C to 70°C.
Mechanical & Electrical
Parameter
Specification
Specification Temperatures (Min/Max)
-20°C to +70°C
Housing Size
2.37” x 1.06” x 0.30”
Housing Drawing
HF3 Package
RF Connectors
SMA Female Replaceable Connectors
Rev Date: 11/17/2015
© API Technologies Corp. Proprietary Information
Page # 1
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
Model # BXHF1203
Typical Performance Graphs
Rev Date:
© API Technologies Corp. Proprietary Information
Page #
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
Model # BXHF1203
Instructions
Grounding Instructions
Care should be taken to effectively ground each unit.
Revisions
API reserves the right to make revisions to both product and/or the information contained within their
datasheets without advanced notice.
Min./Max. Values
Specifications are guaranteed when tested in a 50 Ω (ohm) system.
Typical performance graphs and values are measured at 25°C, but not guaranteed.
Outline Drawing (for reference only)
Rev Date: 11/17/2015
© API Technologies Corp. Proprietary Information
Page # 3
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]