A. Input Characteristics: 1) Voltage: (100-127) / (200-250)VAC 2) Frequency: 50/60 Hz. 3) Line Current: 15A / 12A Maximum 4) Load Capacity: 2.40 / 3.68 KVA 5) Overload Protection: (1) 2P/15 AMP CB 6) Power Cord: NO 7) Connector: IEC 60320 C20 B. Output Characteristics: 1) Voltage: (100-127) / (200-250)VAC 2) Current: 15A / 12A, Total Combined Load 3) Outlets: 9X IEC 60320 C13 2) RoHS: Compliant to Directive 2002/95/EC C. Mechanical Characteristics: 1) Material: CRS .750 in / 19.1 mm 3) Lettering: Silk-Screen, White/Epoxy 4) Storage Temp.: -(13) - 149F (-25 - 65C) D. Operating Environment: 1) Temperature: 32 - 122F (0 - 50C) .500 in / 12.7 mm 2) Finish: Powder Coat, Black, Fine Texture 15.500 in / 393.7 mm 14.750 in / 374.7 mm 2) Relative Humidity: 0 - 95% (Non-Condensing) 3) Elevation: 0 - 10,000FT (0 - 3000 m) E. Regulatory Conformance: 1) Safety Agency: UL/cUL, UL60950-1, CE 14.000 in / 355.6 mm 2.500 in / 63.5 mm 1.500 in / 38.1 mm 0 REV 2.700 in / 68.6 mm 1.811 in / 46 mm CHANGE NOTICE 1472-ENG 1.730 in / 43.9 mm DRAWINGS IN ACCORDANCE WITH STANDARD ANSI Y14.5M-1994 . THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND IS COPYRIGHTED. EXCEPT WITH THE WRITTEN PERMISSION OF SPECTRUM CONTROL, INC. OR ITS SUBSIDIARIES, SUCH INFORMATION SHALL NOT BE PUBLISHED OR DISCLOSED TO OTHERS, OR USED FOR ANY PURPOSE AND THIS DOCUMENT SHALL NOT BE DUPLICATED IN WHOLE OR IN PART. DRAWN: CarrS TOLERANCES UNLESS OTHERWISE SPECIFIED: FRACTIONS ±1/64 DECIMAL .XX ± .020 DECIMAL .XXX ±.010 DATE 11/3/2009 ANGLES ± 030' Spectrum Management Systems PDU,0U-SAT,9/C13,15A,CB THIRD ANGLE PROJECTION SHEET: 1 OF 1 72A-115BUIEN-00 CODE IDENT NO: STATE COLLEGE, PENNSYLVANIA