Hardware DIAdem™ 9 Supports The following list is an overview of DIAdem supported hardware. The overview does not contain any information about applying the measurement hardware with DIAdem, but we would be glad to advise you about the best possible solution for your particular task. You can use the DIAdem drivers with Windows 9x, XP, 2000, ME, and NT 4.0 Service Pack 6 or later NATIONAL INSTRUMENTS Download drivers from ni.com/germany/diadem The NI-DAQ driver basically supports all the NI hardware for which virtual channels can be configured in NI-MAX (Measurement and Automation Explorer). However, the following list does not include all the hardware. 1200 Series, 652X Devices, 653X Devices, AT-AI-16XE-10, AT-DIO-32F, AT-MIO-16DE-10, AT-MIO-16E-1, AT-MIO-16E-10, AT-MIO16E-2, AT-MIO-16F-10, AT-MIO-16F-5, AT-MIO-16XE-10, AT-MIO-16XE-50, AT-MIO-64E-3, AT-MIO-64F-5, DAQCard-500, DAQCard-6023E, DAQCard-6024E, DAQCard-6036E, DAQCard-6062E, DAQCard-6601, DAQCard-6715, DAQCard-700, DAQCard-AI-16E-4, DAQCard-AI-16XE-50, DAQPad-6020E, DAQPad-6052E for 1394, DAQPad-6052E for USB, DAQPad-6070E, DAQPad-MIO-16XE-50, DIO-24, DIO-96, E series devices, I series devices , Lab-PC+, NEC-AI-16E-4, NEC-AI-16XE-50, NEC-MIO-16E-4, NEC-MIO-16XE-50, NI 4451 for PCI , NI 4452 for PCI , NI 4454 for PCI , NI 4472 for PXI/Compact PCI , NI 4551 for PCI , NI 4552 for PCI, PCI-6023E, PCI-6024E, PCI-6025E, PCI-6031E (MIO-64XE-10), PCI-6032E (AI-16XE-10), PCI-6033E (AI-64XE-10), PCI-6034E, PCI-6035E, PCI-6040E, PCI-6052E, PCI-6071E (MIO-64E-1), PCI-6110, PCI-6111, PCI-6115, PCI-6120, PCI-6527, PCI-6602, PCI-6608, PCI-6624, PCI6703, PCI-6704 , PCI-MIO-16E-1, PCI-MIO-16E-4, PCI-MIO-16XE-10, PCI-MIO-16XE-50, PC-OPDIO-16 PCI-4453, PCI-4454 PXI-6011E, PXI-6023E, PXI-6024E, PXI-6025E, PXI-6030E, PXI-6031E, PXI-6031E, PXI-6034E, PXI-6035E, PXI-6040E, PXI-6052E, PXI-6070E, PXI-6115 , PXI-6120 , PXI-6527 , PXI-6602, PXI-6608, PXI-6624 , PXI-6703, PXI-6704 , VXI-AO-48XDC, VXI-DIO-128, VXI-MIO-64E-1, VXI-MIO-64XE-10; 516 and LPM Devices EISA-A2000; NEC-AI-16E-4, -16XE-50; NEC-MIO-16E-4, -16XE-50 NI-CAN IEC-BUS: PCI-GPIB, PXI-GPIB, PCMCIA-GPIB , PC-II, PC-IIa FieldPoint Modular I/O System (via OPC) SCRIPT DAC DRIVER Device connection via ActiveX and GfSUDI (RS232; GPIB) RS232/V.24 interface: COM1 to COM9 IEC-Bus (IEEE 488 / IEEE 625): National Instruments PCII, PCIIa und register compatibles with the IEC bus controller µPD7210: GTI (iPC 488, iPC 488L), ines ieee 488, Intelligent Instrumentation (PCI-801K, PCI-813K), Keithley (KPC-488.2, KPC-AT) SOUND-DRIVER Data input and output via your computer sound card TCP/IP Data exchange between different DIAdem PCs via TCP/IP in Intranet and Internet DIAdem has the following interfaces: OPC: OLE for Process Control describes how to use standard protocols under Windows 9x, 2000, NT 4.0, ME, and Win NT 4.0 in the area of process automation. An overview of the listed OPC server can be found at the end of this document. DLL Interface: The General Programming Interface (GPI) allows to integrate hardware developed by the customer or hardware that is not supported in DIAdem as a standard. The drivers are programmed as a Windows-DLL . You can download example drivers for DIAdem free of charge from ni.com/germany/diadem (programming language: C++). © National Instruments Corporation · 11500 North Mopac Expressway · Austin, Texas 78759-3504 · USA · ni.com/diadem Overview of the Supported Hardware from other Manufacturers You can obtain the drivers for the following hardware from the manufacturers. Manufacturer Device ADAS ADAS Alpha 900 series (via OPC-Server) BEDO PCS05 (Watchdog), PCS11 CSM AD-Scan, Thermo-Scan, BARO-Scan DATA TRANSLATION DT 2811-PGH, -PGL, -AI, -AI32, -AI64, DT 2812, A, 2814, 2817, 2819, DT 282x, DT 283x DT 300er series, DT 330 series, DT 335, DT 340, DT 3000er series, DT 3010 series; DT 9800 series; DT 01 EZ, 16, 21, 23, 24, 31, 34; DT 2801 series DT 710x (Not supported under Windows NT and 2000.) EAGLE ELECTRIC PC-30, B, C, D, DS, DS/4, F, FA, FAS/16, FAS/4, FS/16, FS/4, G, GA, GAS/4, GAS/16, GS/4, GS/16, PGH, PGL GOLDAMMER Multichoice light, Multichoice III (Triathlon), PC-DA 16 Multichoice lightPCI, Multichoice lightPCI/HS, Multichoice lightPCI/HS/16/20, Multichoice lightPCI/HS/16B, PC-DA 8 PCI,PC-DA 8 PCI HS, PC-DA 8 PCI HS/F, PC-DA 8 PCI /B, PC-DA 16 PCI, PC-DA 16 PCI HS, PC-DA 16 PCI HS/F, PC-DA 16 PCI/B, MU Count/Peri4, MU Count/Inkr4, MU CountInkr4/S, MU CountInkr4/HS, MU Count8/P, MU Count8/P, MU CountPWM8, MU Count8/UP, MU Count8/HS, MU Count16, MU Count16/HS www.csm.de www.goldammer.de Multichoice Quattro/O, Module: QUHS12/100, QUHS16/40, QUDA12/20, QU/PE, QU/Inkre/4, QU/Inkre/4/S, QU/Inkre/8/S, QU/Inkre/6/32, QU/8/UP, QU/PWM, QU/Opto/16/16, QU/Rel8, QU/SHC, QU/DIFF32, QU/DIFF32/FMUX, QU/PGA1, QU/PGA2, QU/DA 12/10/4, QU/DA 16/10/4, QU/DA 16/10/8, QU/UI 12/10/4 HOTTINGER BALDWIN MESSTECHNIK (SPECTRIS) DMC 9012/A: DMV 10, 30, 35, 50, 55 DMCplus: DV01, 10, 30, 35, 55, 60, DZ65 MGC: MC01, 30, 50, 55 UPM 60/UGR 60: UMH3201, 3202, 3204A, 3205, 3208, 320 UPM 100: UMH3251, 3252, 3253 Spider8 MGCplus INES IEC-Bus: IEEE 488 (cf. Script DAC Driver) INTELLIGENT INSTRUMENTATION PCI 20.377W-1, -2, 20.428W-1, -2, -3 PCI 20.087W-1, 20.089W-1, 20.091W-1, 20.093W-1, PCI 20.001C-1, -2, 20.041C-2, -3, 20.098C-1, -1B, -2, -2F; PCI 20002M-1, 20003M-2/4, 20004M-1, 20005M-1, 20006M-1/2, 20007M-1A, 20019M-1, 20020M-1, 20021M-1, 20023M-1, 20031M-1, 20341M-1, 20363M-1, 20364M-1 IEC-Bus: PCI-801K, PCI-813K (cf. Script DAC Driver) EDAS-1002E-1 IPETRONIK KIM/SIM modules (via CAN bus ) JÄGER Adwin,light, gold; Adwin pro KEITHLEY INSTRUMENTS DAS 1201, 1202, 1401, 1402, 1601, 1602, 16, 16F, 16G1, 16G2 IEC-Bus: KPC-488.2, KPC-AT (cf. Script DAC Driver) MEC MEC 1000: SP02/08/20, SP1T10/T20, Strain Gauge, Thermo, Current, PCB, Pt100, Carrier frequency, Frequency MICROSTAR DAP800, 801, 1200, -a, -e, 1216a, -e, 2400, -a, -e, 2416a, -e, 3000a, 3200a, -e; DAP3216a, 4200; 3400a NANO SYSTEMS Inccon counter boards: 1/HR16, 1/SR16, 1/HR32, 1/SR32; 2/HR16, 2/SR16, 2/HR32, 2/SR32; 3/HR16, 3/SR16; 4/HR16, 4/SR16 Download drivers from ni.com/germany/diadem © National Instruments Corporation · 11500 North Mopac Expressway · Austin, Texas 78759-3504 · USA · ni.com/diadem Manufacturer Device PEEKEL Autolog SENG AnaDigIO SIEMENS S5 OPC, and S7 OPC server (via OPC Client) SOFTING Softing Application Controller 2 (CAN AC2, CANCard) SOLARTRON (MESTEC) IMP system with the module types 1A, 1B, 1C, 1H SPECTRA ADAM module series 4000/5000 (via OPC Server) VECTOR CAN-DB for CANcardX CANape YOKOGAWA Darwin series www.mdi-dd.de © National Instruments Corporation · 11500 North Mopac Expressway · Austin, Texas 78759-3504 · USA · ni.com/diadem OPC Server with DIAdem™ as OPC Client OPC means OLE for Process Control and describes how to use standard protocols under Windows 9x, 2000, ME, and Win NT 4.0 in the area of process automation. DIAdem as an OPC client supports the connection to one and more OPC servers for access to hardware and field busses. The following list is only an overview of the OPC servers that have been tested with DIAdem as the OPC client, from various hardware manufacturers. It is not a complete list. Ask your manufacturer whether there is an OPC server for devices that are not included in the list. Manufacturers Hardware Server version Field bus NATIONAL FieldPoint modular I/O system, INSTRUMENTS NI-DAQ – Driver library for NI hardware, Lookout, LabVIEW™ DSC ADAS OPC server for Alpha 900 series AG-E Agent OPC server version 1.0a; PC plug in board for die field busses: Profibus (to 12 Mbaud), Interbus, CANopen, DeviceNet, Siemens protocols 3964/R and MPI, Modbus RTU/ASCII APPLICOM OPC server (OPC server version 1.0A, 2.0) PC plug in board for several field busses and industrial networks: Seriell: boards - PCI1000, PC2000, PCI4000 via Kit 4000TD - 3964/3964R, AS511, Batibus, Data Link, DF1, Jbus, Modbus, PPI+ PPI, Saia-Bus, SNP-X, SucomA, Sysmac Way, TIDir, Uni-Telway, User specific Profi bus boards: PCI1500PFB (DP, FDL S5 series, FMS, MPI, PPI+, PPI, S7 protocol) PCI1500S7 (MPI, PPI+, PPI, S7 protocol) PCI2000 (PFB, DP 12MBaud) Ethernet boards: PCI2000ETH (Ethway, Sinec H1, Industrial Ethernet, TCP/IP) Interbus boards: PCI2000IBS (Interbus-S Master) WorldFIP boards: PCI2000FIP (Fipway) COMSOFT DK3964K/RK512, Sinec-L1, Unidrv, LSV2, USV2, HDLC UNC, LAP-B, Profi bus (L2, FMS, DP/DPV1) FACTORYSOFT FactorySoft OPC toolkit / Demo server FISHER DeltaV OPC server ROSEMOUNT GESYTEC Easylon HILSCHER Profibus-DP, -FMS; Interbus, CANopen, DeviceNet, ControlNet IFAK _isOPCMultiServer für _isProMultoboard, _isProPCMCIA, _isProUSB, _isSpidoFast INAT Connecting S5 and S7 via TCP/IP & H1, AS511 (RS232C), MPI (CP or RS232) IOTECH TempScan, MultiScan, ChartScan, NetScan KEPWARE Allen Bradley SLC500/MicroLogix, Analog Devices 6B series, AnchorPLC, Aromat/Matsushita Computer Link, Contrex (CX1000, M series), Cutler Hammer, GE Fanuc (CCM, Ethernet, SNP, SNPX), Idec Computer Link, Kessler-Ellis products Keptrol, Koyo PLCDirect (Net, Ethernet, K sequence), Fischer & Porter Micro-DCI, Modbus (ASCII, Plus, RTU Serial, RTU Slave; Modicon Modbus Ethernet), Endress+Hauser MemoLog, Mitsubishi (A Series, FX, FX NET), Omron Host Link, Partlow ASCII, Siemens (S7-200, Simatic 505), SquareD Serial, Intelligent Actuator Super SEL, Telemecanique Unitelway, Tiway, Toshiba (Computer Link, G3 Drive), Toyopuc (PC2 Ethernet, PC2 Computer Link, PC3 Ethernet) PHOENIX OPC Call server for Interbus CONTACT ROCKWELL RSLinx (OPC server version 2.0) SOFTWARE SIEMENS Simatic Net DP: Profibus OPC server for DP (S7/S5 functions via Profibus, Industrial Ethernet/H1) Simatic Net Profibus FMS SOFTING 4Control (OPC server version 1.0), Profibus DP server, CANopen server (CANpci) SPECTRA ADAM module series 4000/5000 USDATA FactoryLink (OPC server version 6.5) © National Instruments Corporation · 11500 North Mopac Expressway · Austin, Texas 78759-3504 · USA · ni.com/diadem