40 GHz Dual SPDT 50 Ω Relay Module
This document lists specifications for the NI PXI-2799 relay module. All specifications are
subject to change without notice. Visit ni.com/manuals for the most current specifications.
Topology ........................................................... 2-SPDT
Refer to the NI Switches Help for detailed topology information.
To ensure the specified EMC performance, operate this product only with
shielded cables and accessories.
Caution
Caution
Device relays might change state momentarily during electrostatic
discharge.
Caution Refer to the Read Me First: Safety and Electromagnetic Compatibility
document at ni.com/manuals for important safety and compliance information.
About These Specifications
Specifications characterize the warranted performance of the instrument under the stated
operating conditions.
Typical Specifications are specifications met by the majority of the instrument under the stated
operating conditions and are tested at 23 °C. Typical specifications are not warranted.
Input Characteristics
Maximum voltage............................................. 30 Vrms
(cold switching only)
Caution Active RF signals must not be switched. As a relay actuates, the channel
is momentarily unterminated. Some RF sources can be damaged by reflections if
their outputs are not properly terminated. Refer to your RF source documentation for
more information.
Maximum carry current .................................... 0.6 Arms
(per channel)
Maximum RF carry power ............................... 18 W
(50 Ω load)
The switching power is limited by the maximum switching current and the
maximum voltage. Channel to common switching power must not exceed 18 W.
Caution
RF Performance Characteristics
Characteristic impedance (Z0) ..........................50 Ω nominal
Insertion loss
≤6 GHz .....................................................<0.3 dB
≤12.4 GHz ................................................<0.4 dB
≤18 GHz ...................................................<0.5 dB
≤26.5 GHz ................................................<0.7 dB
≤40 GHz ...................................................<0.8 dB
Voltage standing wave ratio (VSWR)
≤6 GHz .....................................................<1.30
≤12.4 GHz ................................................<1.40
≤18 GHz ...................................................<1.50
≤26.5 GHz ................................................<1.70
≤40 GHz ...................................................<1.90
Open channel isolation
≤6 GHz .....................................................>70 dB
≤12.4 GHz ................................................>60 dB
≤18 GHz ...................................................>60 dB
≤26.5 GHz ................................................>55 dB
≤40 GHz ...................................................>50 dB
RF carry power
≤26.5 GHz ................................................18 W
≤40 GHz ...................................................10 W
2 | ni.com | NI PXI-2799 Specifications
Refer to the following figure for the typical insertion loss of the NI PXI-2799.
Figure 1. Typical Insertion Loss and Isolation
0.0
Insertion Loss (dB)
–0.1
–0.2
–0.3
–0.4
–0.5
0
5
10
15
20
25
Frequency (GHz)
30
35
40
35
40
Refer to the following figure for the typical isolation of the NI PXI-2799.
Figure 2. Typical Isolation
0
–20
Isolation (dB)
–40
–60
–80
–100
–120
–140
0
5
10
15
20
25
Frequency (GHz)
30
NI PXI-2799 Specifications | © National Instruments | 3
Refer to the following figure for the typical VSWR of the NI PXI-2799.
Figure 3. Typical VSWR
2.0
1.9
1.8
1.7
VSWR
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0
5
10
15
20
25
Frequency (GHz)
30
35
40
Dynamic Characteristics
Relay operate/release time ................................10 ms
Certain applications may require additional time for proper settling. Refer to
the NI Switches Help for information about including additional settling time.
Note
Expected relay life
Mechanical................................................1 × 107 cycles
Trigger Characteristics
Input trigger
Sources......................................................PXI trigger lines 0-7
Minimum pulse width ...............................150 ns
Note The NI PXI-2799 can recognize trigger pulse widths less than 150 ns by
disabling digital filtering. For information about disabling digital filtering, refer to
the NI Switches Help.
Output trigger
Destinations ..............................................PXI trigger lines 0-7
Pulse width................................................Programmable (1 μs to 62 μs)
4 | ni.com | NI PXI-2799 Specifications
Physical Characteristics
Relay manufacturer/PN .................................... Radiall/R571 series
Relay type ......................................................... Electromechanical, latching
Contact material................................................ Beryllium copper, gold-plated
I/O connector .................................................... 6 SMA 2.9 jacks
SMA Torque ..................................................... 0.8 N · m to 1.1 N · m
(7 in. · lbs to 10 in. · lbs)
PXI power requirement .................................... 2.5 W at 3.3 V,
1 W at 5 V,
6 W at 12 V
Dimensions (L × W × H) .................................. 3U, one slot,
PXI/cPCI module,
21.6 × 2.0 × 13.0 cm
(8.5 × 0.8 × 5.1 in.)
Weight............................................................... 229 g (8.125 oz)
Environment
Operating temperature ...................................... 0 °C to 55 °C
Storage temperature .......................................... -20 °C to 70 °C
Relative humidity ............................................. 5% to 85%, noncondensing
Pollution Degree ............................................... 2
Maximum altitude............................................. 2,000 m
Indoor use only.
Shock and Vibration
Operational shock ............................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Test profile developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating .................................................. 5 to 500 Hz, 0.3 grms
Nonoperating ............................................ 5 to 500 Hz, 2.4 grms
(Tested in accordance with IEC 60068-2-64.
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.)
NI PXI-2799 Specifications | © National Instruments | 5
Diagrams
Figure 4 shows the NI PXI-2799 power-on state.
Figure 4. NI PXI-2799 Power-On State
K0
NC0
COM0
NO0
K1
NC1
COM1
NO1
Figure 5 shows the NI PXI-2799 front panel.
Figure 5. NI PXI-2799 Front Panel
NI PXI-2799
40 GHz Dual SPDT
50 Ω Relay Module
6 | ni.com | NI PXI-2799 Specifications
30 Vrms
18W MAX
NC 0
COM 0
NO 0
30 Vrms
18W MAX
NC 1
COM 1
NO 1
Note For topology-specific connection information, refer to your device in the
NI Switches Help.
Compliance and Certifications
Safety
This product meets the requirements of the following standards of safety for electrical equipment
for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or the Online
Product Certification section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:
•
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
•
EN 55011 (CISPR 11): Group 1, Class A emissions
•
AS/NZS CISPR 11: Group 1, Class A emissions
•
FCC 47 CFR Part 15B: Class A emissions
•
ICES-001: Class A emissions
Note In the United States (per FCC 47 CFR), Class A equipment is intended for use
in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada,
Australia and New Zealand (per CISPR 11) Class A equipment is intended for use
only in heavy-industrial locations.
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical
equipment that does not intentionally generates radio frequency energy for the
treatment of material or inspection/analysis purposes.
Note For EMC declarations and certifications, refer to the Online Product
Certification section.
CE Compliance
This product meets the essential requirements of applicable European Directives as follows:
•
2006/95/EC; Low-Voltage Directive (safety)
•
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
NI PXI-2799 Specifications | © National Instruments | 7
Online Product Certification
To obtain product certifications and the Declaration of Conformity (DoC) for this product, visit
ni.com/certification, search by model number or product line, and click the appropriate
link in the Certification column.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.
For additional environmental information, refer to the Minimize Our Environmental Impact web
page at ni.com/environment. This page contains the environmental regulations and
directives with which NI complies, as well as other environmental information not included in
this document.
Waste Electrical and Electronic Equipment (WEEE)
At the end of the product life cycle, all products must be sent to a
WEEE recycling center. For more information about WEEE recycling centers,
National Instruments WEEE initiatives, and compliance with WEEE Directive
2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/
environment/weee.
EU Customers
⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑ RoHS˅
Ё೑ᅶ᠋ National Instruments ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ
(RoHS)DŽ݇Ѣ National Instruments Ё೑ RoHS ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/
environment/rohs_chinaDŽ (For information about China RoHS compliance,
go to ni.com/environment/rohs_china.)
LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments
Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and
company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments
products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National
Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal
notices in the NI-SWITCH Readme. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National
Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.
© 2012 National Instruments. All rights reserved.
375890A-01
Sep12