DB151(S) - RFE International, Inc.

BRIDGE RECTIFIER
1.5 Amps
DB151(S) Thru DB157(S)
RoHS
Cross for DF1500M Thru DF1510M
FEATURES
• UL Recognized
• Current 1.5 Amps
• Voltage Range 50V ~ 1000V
• Glass passivated chip junction
• Low forward voltage drop, high current capability
• Available in 1.0Amp, 1.5Amps and 2.0Amps
No Suffix
Suffix - S
MECHANICAL DATA
DB - S
DB
• Molded plastic body (UL 94V-0 rated)
• Mounting position: any; Lead: soler plated
• Polarity: As marked
MAXIMUM RATINGS & ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load
For capactitive load, derate current by 20%
Parameter
Symbol
DB151 DB152 DB153 DB154 DB155 DB156 DB157
(S)
(S)
(S)
(S)
(S)
(S)
(S)
DF15005M
DF1501M
DF1502M
DF1504M
DF1506M
DF1508M
DF1510M
Unit
Maximum Repetitive Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC blocking Voltage
VDC
50
100
200
400
600
800
1000
V
Maximum Average Forward Rectified
Current, @TC=40°C
Peak Forward Surge Current 8.3ms single
half sine-wave superimposed on rated load
(JEDEC method)
2
Io (AV)
1.5
A
IFSM
30
A
I t for fusing (t < 8.3ms), non-repetitive
I t
2
3.7
AS
Max. Instantaneous Forward Voltage @1.5A
VF
1.1
V
Maximum DC Reverse Current
at rated DC Blocking voltage Per Element
IR
10
A
Typical Thermal Resistance (Note)
RJL
15
°C/W
Operating Temperature Range
TJ
-55 to + 150
°C
TSTG
-55 to + 150
°C
Storage Temperature Range
2
NOTE: Thermal Resistance from Junction to Lead mounted on P.C.B. with 0.47” x 0.47” (12mm x 12mm) copper pads
Page 1 of 2
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C3DB015
2014.08.07
BRIDGE RECTIFIERS
DB151(S) Thru DB157(S)
RoHS
1.5 Amps
Cross for DF1500M Thru DF1510M
RATING & CHARACTERISTIC CURVES
FIG.2- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
FIG.1- MAXIMUM FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT (A)
AVERAGE FORWARD CURRENT (A)
Sine wave
Sine wave R-load
free in air
non-repetitive
TJ=25°C
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL INSTANTANEOUS FORAWARD
CHARACTERISTICS
FIG.4-TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT (uA)
INSTANTANEOUS FORWARD SURGE CURRENT (A)
Tj=150°C
Ta=25°C
Tj=25°C
INSTANTANEOUS FORWARD VOLTAGE (V)
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
DIMENSIONS in inches and (millimeters)
.205(5.2)
.195(5.0)
.315(8.00)
.285(7.24)
+
+
.255(6.5)
.245(6.2)
~
.335(8.51)
.320(8.13)
.08(2.03)
.05(1.27)
~
.013(0.33)
.0088(0.22)
~
.130(3.30)
.120(3.05)
.185(4.69)
.150(3.81)
.060(1.53)
.040(1.02)
.013(0.33)
.0088(0.22)
~
.013(0.33)
.003(0.076)
.205(5.2)
.195(5.0)
.350(8.9)
.300(7.6)
.045(1.14)
.035(0.89)
.404(10.3)
.255(6.5) .386(9.80)
.245(6.2)
.083(2.10)
.071(1.80)
.335(8.51)
.320(8.13)
.130(3.30)
.120(3.05)
DB
DBS
.047(1.20)
.040(1.02)
.023(0.58)
.018(0.46)
Page 2 of 2
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]