G - RFE International, Inc.

GENERAL PURPOSE RECTIFIER
RoHS
1N5391 (G) Thru 1N5399 (G) 1.5A
.300(7.60)
.228(5.80)
1.5 amps, 50 to 1000V
Available with glass passivated chip junction, suffix G
Low forward voltage drop
High reliability
.142(3.60)
.035(0.90)
.102(2.60)
.028(0.70)
DIA
•
•
•
•
1.0(25.4)
MIN
1.0(25.4)
MIN
FEATURES
DO-204AC (DO-15)
Dimensions in inches and (millimeters)
MECHANICAL DATA
• Molded plastic body (UL-94V-0 rated)
• Lead: Axial leads,solderable per MIL-STD-202,
Method 208
• Polarity: Color band denotes cathode end
• Weight: 0.40 grams
MAXIMUM RATINGS & ELECTRICAL CHARACTERISTICS
Parameter
Symbol
1N5391 1N5392 1N5393 1N5395 1N5397 1N5398 IN5399
Unit
(G)
(G)
(G)
(G)
(G)
(G)
(G)
Maximum Repetitive
Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC Blocking
Voltage
VDC
50
100
200
400
600
800
1000
V
Maximum Average Forward
Rectified Current
TA = 50ºC
IF(AV)
1.5
A
Peak (Non-Repetitive) Forward
Surge Current 60Hz Half-Sine
Wave, 1 Cycle
IFSM
50
A
Forward Voltage Drop
IFM = 1.5A
VFM
1.1
V
IRRM1
IRRM2
5
50
mA
R0JA (Note 1)
25
R0JL (Note 2)
20
Peak DC Reverse Current
@ TA = 25ºC
@ TA = 125ºC
Typical Thermal Resistance
Junction to Lead
Operating Temperature Range
Storage Temperature Range
ºC/W
TJ
-55 to +125 / -55 to +175 for (G)
-55 to +150
T STG
˚C
˚C
NOTE: Thermal resistance from junction to ambient 0.375" (9.5mm) lead length.
Page 1 of 2
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C3CG01
2014.04.02
GENERAL PURPOSE RECTIFIER
RoHS
1N5391 (G) Thru 1N5399 (G) 1.5A
RATING & CHARACTERISTIC CURVES
FIG.1-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
FIG.2-MAXIMUM FORWARD CURRENT DERATING
1.5
1.
AVE RAGE FORWA RD CUR RE NT (A)
PEAK FOR WARD SURG E CUR RE NT ( A)
50
40
8.3ms Single Half Sine Wave
JEDEC Method
30
20
10
1
2
10
20
1.2
1N5391G ~ 1N5399G
0.9
1N5391 ~ 1N5399
0.6
0.3
Single Phase Half Wave 60Hz Resistive or
Inductive Load 0.375''(9.5mm) Lead Length
0
0
100
50
100
150
175
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.4-TYPICAL REVERSE CHARACTERISTICS
1000
INSTANTANE OUS REVERS E CURR ENT (uA)
INSTANTANEOU S FORWA RD S URGE CURR ENT (A)
20
10
4.0
2.0
1.0
0.4
0.2
0.1
TJ=25℃
Pulse width=300us
1% Duty Cycle
0.04
100
Tj=125℃
10
Tj=100℃
1.0
Tj=25℃
0.1
0.02
0.01
0
0.01
0.6
0.8
1.0
1.2
20
40
60
80
100
1.4
INSTANTANEOUS FORWARD VOLTAGE (V)
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
Page 2 of 2
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
2014.04.02