Smart Motor Controllers — SMC PLUS

Bulletin 150
Smart Motor Controllers — SMC PLUS
Product Selection
Open Type Controllers
Up to 480V AC
kW ➊
HP ➋
Current Rating
(A)
230V AC
50 Hz
400V AC
50 Hz
200V AC
60 Hz
230V AC
60 Hz
460V AC
60 Hz
Cat. No. ➌
Price
Adder
Code
24
5.5
11
1…5
1…7.5
1…15
150-A24NBD
a
35
54
10
15
18.5
22
1…10
1…15
1…10
1…20
1…25
1…40
150-A35NBD
150-A54NBD
b
c
97
135
25
37
45
75
5…30
5…40
5…30
5…50
5…75
5…100
150-A97NBD
150-A135NBD
d
e
180
240
51
75
90
132
5…60
5…75
5…60
5…75
5…150
5…200
150-A180NBD
150-A240NBD
f
g
360
500
110
150
200
257
5…125
5…150
5…150
5…200
5…300
5…400
150-A360NBD
150-A500NBD
h
i
650
200
355
5…200
5…250
5…500
150-A650NBD
j
720
850
220
257
400
475
5…250
10…300
5…300
10…350
5…600
10…700
150-A720NBD
150-A850NBD
k
l
1000
315
530
10…350
10…400
10…800
150-A1000NBD
m
Up to 600V AC
kW ➊
HP ➋
Cat. No. ➌
Price
Adder
Code
24
5.5
11
15
1…5
1…7.5
1…15
1…20
150-A24NCD
a
35
54
10
15
18.5
22
22
37
1…10
1…15
1…10
1…20
1…25
1…40
1…30
1…50
150-A35NCD
150-A54NCD
b
c
97
135
25
37
45
75
63
90
5…30
5…40
5…30
5…50
5…75
5…100
5…75
5…125
150-A97NCD
150-A135NCD
d
e
180
240
51
75
90
132
132
160
5…60
5…75
5…60
5…75
5…150
5…200
5…150
5…250
150-A180NCD
150-A240NCD
f
g
360
500
110
150
200
257
250
355
5…125
5…150
5…150
5…200
5…300
5…400
5…350
5…500
150-A360NCD
150-A500NCD
h
i
650
720
200
220
355
400
475
500
5…200
5…250
5…250
5…300
5…500
5…600
5…600
5…700
150-A650NCD
150-A720NCD
j
k
850
1000
257
315
475
530
600
710
10…300
10…350
10…350
10…400
10…700
10…800
10…800
10…1000
150-A850NCD
150-A1000NCD
l
m
Current
Rating (A)
230V AC 50 400V AC 50 500V AC 50 200V AC 60 230V AC 60 460V AC 60 575V AC 60
Hz
Hz
Hz
Hz
Hz
Hz
Hz
➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated
850 A and greater.
➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively.
➌ Controllers are shipped from the factory preset for soft start mode, 10 s acceleration, energy saver inactive, motor stall inactive, and control
power 100…240V AC, 50/60 Hz.
Accessories — Page 49
Options — Page 50
Specifications — Page 57
Approximate Dimensions — Page 59
43
Bulletin 150
Smart Motor Controllers — SMC PLUS
Product Selection, Continued
IP30 (Type 1) Enclosed Non-Combination Controllers
SMC Easy Ship program Cat. Nos. are printed in blue.
See page 39.
Bulletin 150 (Non-Combination Controller) — The SMC PLUS Controller requires a separate 100…240V, 50/60 Hz single-phase
control source. A thermal overload is not included. Terminals are provided for a separate thermal overload relay connection to the
control circuit. Enclosures other than those listed are available. Consult Allen-Bradley Sales Office.
Up to 480V AC
kW ➊
HP ➋
Cat. No. ➌
Dimension
Code
Price
Adder
Code
1…15
150-A24JBD
Q
a
1…25
1…40
150-A35JBD
150-A54JBD
Q
Q
b
c
5…75
5…100
150-A97BBD
150-A135BBD
R
T
d
e
5…60
5…75
5…150
5…200
150-A180BBD
150-A240BBD
T
T
f
g
5…125
5…150
5…300
150-A360BBD
U
h
5…150
5…200
5…200
5…250
5…400
5…500
150-A500BBD
150-A650BBD
W
X
i
j
400
450
5…250
10…300
5…300
10…350
5…600
10…700
150-A720BBD
150-A850BBD
X
X
k
l
500
10…350
10…400
10…800
150-A1000BBD
X
m
Current
Rating (A)
230V AC 50
Hz
400V AC 50
Hz
24
5.5
35
54
10
15
97
135
200V AC 60
Hz
230V AC 60
Hz
460V AC 60
Hz
11
1…5
15
22
1…10
1…15
1…7.5
1…10
1…20
25
37
45
55
5…30
5…40
5…30
5…50
180
240
51
75
90
110
5…60
5…75
360
500
650
110
200
150
200
250
355
720
850
220
257
1000
315
Up to 600V AC
kW ➊
Current
Rating
(A)
230V AC
50 Hz
24
35
54
HP ➋
Cat. No. ➌
Dimension
Code
Price
Adder
Code
1…20
150-A24JCD
Q
a
1…30
1…50
150-A35JCD
150-A54JCD
Q
Q
b
c
5…75
5…100
5…75
5…125
150-A97BCD
150-A135BCD
R
T
d
e
5…60
5…75
5…150
5…200
5…150
5…250
150-A180BCD
150-A240BCD
T
T
f
g
5…125
5…150
5…150
5…200
5…300
5…400
5…350
5…500
150-A360BCD
150-A500BCD
U
W
h
i
475
500
5…200
5…250
5…250
5…300
5…500
5…600
5…600
5…700
150-A650BCD
150-A720BCD
X
X
j
k
475
600
10…300
10…350
10…700
10…800
150-A850BCD
X
l
530
710
10…350
10…400
10…800
10…1000
150-A1000BCD
X
m
400V AC
50 Hz
500V AC
50 Hz
200V AC
60 Hz
230V AC
60 Hz
460V AC
60 Hz
575V AC
60 Hz
5.5
11
10
15
18.5
22
15
1…5
1…7.5
1…15
22
37
1…10
1…15
1…10
1…20
1…25
1…40
97
135
25
37
45
75
63
90
5…30
5…40
5…30
5…50
180
240
51
75
90
132
132
160
5…60
5…75
360
500
110
150
200
257
250
355
650
720
200
220
355
400
850
257
1000
315
➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated
850 A and greater.
➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively.
➌ Controllers are shipped from the factory preset for soft start mode, 10 second acceleration, energy saver inactive, motor stall active, and control
power 100…240V AC, 50/60 Hz.
Accessories — Page 49
Options — Page 50
Specifications — Page 56
Approximate Dimensions — Page 59
44
Bulletin 150
Smart Motor Controllers — SMC PLUS
Product Selection, Continued
IP65 (Type 4) Enclosed Non-Combination Controllers
Bulletin 150 (Non-Combination Controller) — The SMC PLUS Controller requires a separate 100…240V, 50/60 Hz single-phase
control source. A thermal overload is not included. Terminals are provided for a separate thermal overload relay connection to the
control circuit. Enclosures other than those listed are available. Consult Allen-Bradley Sales Office.
Up to 480V AC
kW ➊
HP ➋
Current
Rating
(A)
230V AC 50
Hz
400V AC 50
Hz
200V AC 60
Hz
230V AC 60
Hz
460V AC 60
Hz
24
35
5.5
10
11
18.5
1…5
1…10
1…7.5
1…10
1…15
1…25
54
97
15
25
22
45
1…15
5…30
1…20
5…30
135
180
37
51
75
90
5…40
5…60
240
360
75
110
132
200
500
150
650
720
200
220
850
1000
257
315
Cat. No. ➌➍
Dimension
Code
Price
Adder
Code
150-A24FBD
150-A35FBD
Q
Q
a
b
1…40
5…75
150-A54FBD
150-A97FBD
Q
S
c
d
5…50
5…60
5…100
5…150
150-A135FBD
150-A180FBD
T
T
e
f
5…75
5…125
5…75
5…150
5…200
5…300
150-A240FBD
150-A360FBD
U
V
g
h
257
5…150
5…200
5…400
150-A500FBD
X
i
355
400
5…200
5…250
5…250
5…300
5…500
5…600
150-A650FBD
150-A720FBD
Z1
Z1
j
k
475
530
10…300
10…350
10…350
10…400
10…700
10…800
150-A850FBD
150-A1000FBD
Z1
Z1
l
m
Up to 600V AC
kW ➊
HP ➋
Cat. No. ➌➍
Dimension
Code
Price
Adder
Code
150-A24FCD
150-A35FCD
Q
Q
a
b
1…50
5…75
150-A54FCD
150-A97FCD
Q
S
c
d
5…100
5…150
5…125
5…150
150-A135FCD
150-A180FCD
T
T
e
f
5…75
5…150
5…200
5…300
5…250
5…350
150-A240FCD
150-A360FCD
V
V
g
h
5…150
5…200
5…200
5…250
5…400
5…500
5…500
5…600
150-A500FCD
150-A650FCD
X
Z1
i
j
500
600
5…250
10…300
5…300
10…350
5…600
10…700
5…700
10…800
150-A720FCD
150-A850FCD
Z1
Z1
k
l
710
10…350
10…400
10…800
10…1000
150-A1000FCD
Z1
m
Current
Rating
(A)
230V AC
50 Hz
400V AC
50 Hz
500V AC
50 Hz
200V AC
60 Hz
230V AC
60 Hz
460V AC
60 Hz
575V AC
60 Hz
24
35
5.5
10
11
18.5
15
22
1…5
1…10
1…7.5
1…10
1…15
1…25
1…20
1…30
54
97
15
25
22
45
37
63
1…15
5…30
1…20
5…30
1…40
5…75
135
180
37
51
75
90
90
132
5…40
5…60
5…50
5…60
240
360
75
110
132
200
160
250
5…75
5…125
500
650
150
200
257
355
355
475
720
850
220
257
400
475
1000
315
530
➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated
850 A and greater.
➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively.
➌ Controllers are shipped from the factory preset for soft start mode, 10 second acceleration, energy saver inactive, motor stall inactive, and control
power 100…240V AC, 50/60 Hz.
➍ 97…1000 A Type 4 SMC PLUS Smart Motor Controllers include Bulletin 100 bypass contactors wired for 120V AC 50/60 Hz.
Accessories — Page 49
Options — Page 50
Specifications — Page 56
Approximate Dimensions — Page 59
45
Bulletin 150
Smart Motor Controllers — SMC PLUS
Product Selection, Continued
IP54 (Type 12) Enclosed Non-Combination Controllers
SMC Easy Ship program Cat. Nos. are printed in
blue. See page 39.
Bulletin 150 (Non-Combination Controller) — The SMC PLUS Controller requires a separate 100…240V, 50/60 Hz single-phase
control source. A thermal overload is not included. Terminals are provided for a separate thermal overload relay connection to the
control circuit. Enclosures other than those listed are available. Consult Allen-Bradley Sales Office.
Up to 480V AC
kW ➊
Current
Rating (A)
230V AC 50
Hz
24
5.5
35
54
10
15
97
135
25
37
180
240
HP ➋
Cat. No. ➌➍
Dimension
Code
Price
Adder
Code
1…15
150-A24JBD
Q
a
1…25
1…40
150-A35JBD
150-A54JBD
Q
Q
b
c
5…75
5…100
150-A97JBD
150-A135JBD
S
T
d
e
5…60
5…75
5…150
5…200
150-A180JBD
150-A240JBD
T
U
f
g
5…125
5…150
5…300
150-A360JBD
V
h
5…150
5…200
5…200
5…250
5…400
5…500
150-A500JBD
150-A650JBD
X
Z
i
j
400
475
5…250
10…300
5…300
10…350
5…600
10…700
150-A720JBD
150-A850JBD
Z1
Z1
k
l
530
10…350
10…400
10…800
150-A1000JBD
Z1
m
400V AC 50
Hz
200V AC 60
Hz
230V AC 60
Hz
460V AC 60
Hz
11
1…5
18.5
22
1…10
1…15
1…7.5
1…10
1…20
45
75
5…30
5…40
5…30
5…50
51
75
90
132
5…60
5…75
360
500
650
150
200
132
200
257
355
720
850
220
257
1000
315
Up to 600V AC
kW ➊
Current
Rating
(A)
230V AC
50 Hz
24
5.5
11
35
54
10
15
18.5
22
97
135
25
37
45
75
180
240
51
75
360
500
400V AC
50 Hz
HP ➋
Cat. No. ➌➍
Dimension
Code
Price
Adder
Code
1…20
150-A24JCD
Q
a
1…30
1…50
150-A35JCD
150-A54JCD
Q
Q
b
c
5…75
5…125
150-A97JCD
150-A135JCD
S
T
d
e
5…150
5…200
5…150
5…250
150-A180JCD
150-A240JCD
T
V
f
g
5…150
5…200
5…300
5…400
5…350
5…500
150-A360JCD
150-A500JCD
V
X
h
i
5…200
5…250
5…250
5…300
5…500
5…600
5…600
5…700
150-A650JCD
150-A720JCD
Z
Z1
j
k
600
10…300
10…350
10…700
10…800
150-A850JCD
Z1
l
710
10…350
10…400
10…800
10…1000
150-A1000JCD
Z1
m
500V AC
50 Hz
200V AC
60 Hz
230V AC
60 Hz
15
1…5
1…7.5
22
37
1…10
1…15
1…10
1…20
63
90
5…30
5…40
5…30
5…50
90
132
110
160
5…60
5…75
110
150
200
257
250
355
650
720
200
220
355
400
850
257
1000
315
460V AC
60 Hz
575V AC
60 Hz
1…15
1…25
1…40
5…75
5…100
5…60
5…75
5…125
5…150
475
500
475
530
➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated
850 A and greater.
➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively.
➌ Controllers are shipped from the factory preset for soft start mode, 10 second acceleration, energy saver inactive, motor stall inactive, and control
power 100…240V AC, 50/60 Hz.
➍ 97…1000 A Type 12 SMC PLUS Smart Motor Controllers include Bulletin 100 Bypass Contactors wired for 120V AC 50/60 Hz.
Accessories — Page 49
Options — Page 50
Specifications — Page 56
Approximate Dimensions — Page 59
46
Bulletin 150
Smart Motor Controllers — SMC PLUS
Product Selection, Continued
Enclosed Combination Controllers ➊
Bulletin 152H/153H (Combination Controller) — Includes a 120V control transformer and a three-pole thermal overload relay
less elements. Where isolating or bypass contactors are required, Bulletin 100 contactors are used (through 600 A). Enclosures
other than those listed are available. Consult Allen-Bradley Sales Office.
HP
Nominal Current
(A)
Price
Adder
Code
IP30 (Type 1) Vented Enclosure
With Fusible Disconnect ➋
Dimension Code
Cat. No.
IP54 (Type 12) Enclosed Combination
Controller
With Fusible Disconnect and
Bypass Contactor ➋
Dimension Code
Cat. No. ➌➍
S
T
T
T
T
U
U
U
V
W
W
W
X2
X2
Y2
Y2
Z2
Z2
Z2
Z3
Z3
152H-WJB-42➏
152H-WJB-43➏
152H-WJB-44➏
152H-WJB-45➏
152H-WJB-46➏
152H-WJB-47
152H-WJB-48
152H-WJB-49
152H-WJB-50
152H-WJB-51
152H-WJB-52
152H-WJB-54
152H-WJB-56
152H-WJB-57
152H-WJB-58
152H-WJB-59
152H-WJB-60
152H-WJB-61
152H-WJB-62
152H-WJB-63
152H-WJB-65
S
T
T
T
T
U
U
V
V
W
W
X2
X2
Y2
Y2
Z2
Z2
Z2
Z3
Z3
Z3
152H-WJC-43➏
152H-WJC-44➏
152H-WJC-45➏
152H-WJC-46➏
152H-WJC-47➏
152H-WJC-48
152H-WJC-49
152H-WJC-50
152H-WJC-51
152H-WJC-52
152H-WJC-54
152H-WJC-56
152H-WJC-57
152H-WJC-58
152H-WJC-59
152H-WJC-60
152H-WJC-61
152H-WJC-62
152H-WJC-63
152H-WJC-65
152H-WJC-67
480V AC, 60 Hz
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
450
500
600
700
800
24
30
35
40
54
70
82
97
125
156
180
240
302
360
410
477
525
575
675
800
915
a
b
b
c
c
d
d
d
e
f
f
g
h
h
i
i
j
j
k
l
m
S
T
T
T
T
U
U
U
V
W
W
W
X2
X2
Y1
Y1
Z1
Z1
Z1
Z1
Z1
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
450
500
600
700
800
1000
24
28
35
40
54
65
80
115
125
170
200
240
310
360
385
450
500
600
700
800
1000
a
b
b
c
c
d
d
e
e
f
g
g
h
h
i
i
i
j
k
l
m
S
T
T
T
T
U
U
V
V
W
W
X2
X2
Y1
Y1
Z1
Z1
Z1
Z1
Z1
Z1
152H-WAB-42➎
152H-WAB-43➎
152H-WAB-44➎
152H-WAB-45➎
152H-WAB-46➎
152H-WBB-47
152H-WBB-48
152H-WBB-49
152H-WBB-50
152H-WBB-51
152H-WBB-52
152H-WBB-54
152H-WBB-56
152H-WBB-57
152H-WBB-58
152H-WBB-59
152H-WBB-60
152H-WBB-61
152H-WBB-62
152H-WBB-63
152H-WBB-65
600V AC, 60 Hz
➊
➋
➌
➍
➎
➏
152H-WAC-43➎
152H-WAC-44➎
152H-WAC-45➎
152H-WAC-46➎
152H-WAC-47➎
152H-WBC-48
152H-WBC-49
152H-WBC-50
152H-WBC-51
152H-WBC-52
152H-WBC-54
152H-WBC-56
152H-WBC-57
152H-WBC-58
152H-WBC-59
152H-WBC-60
152H-WBC-61
152H-WBC-62
152H-WBC-63
152H-WBC-65
152H-WBC-67
208V and 240V Controllers are available. Consult Allen-Bradley Sales Office.
See page 56 for fuse clip size and type information.
Accu-Stop Control is not available when a bypass contactor is used.
Bypass contactors are used to bypass the SMC PLUS Controller when the motor has reached full speed.
Includes internal circulating fan rather than enclosure ventilation.
Includes internal circulating fan rather than bypass contactor.
Accessories — Page 49
Options — Page 50
Specifications — Page 56
Approximate Dimensions — Page 59
47
Bulletin 150
Smart Motor Controllers — SMC PLUS
Product Selection, Continued
Enclosed Combination Controllers ➊
SMC Easy Ship program Cat. Nos. are printed in blue. See page 39.
Bulletin 152H/153H (Combination Controller) — Includes a 120V control transformer and a three-pole thermal overload relay
less elements. Where isolating or bypass contactors are required, Bulletin 100 contactors are used (through 600 A). Enclosures
other than those listed are available. Consult Allen-Bradley Sales Office.
HP
Nominal Current
Price
Adder
Code
IP30 (Type 1) Vented Enclosed Combination
Controllers With Circuit Breaker ➋
Dimension Code
Cat. No.
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
450
500
600
700
800
24
30
35
40
54
70
82
97
125
156
180
240
302
360
410
477
525
575
675
800
915
a
b
b
c
c
d
d
d
e
f
f
g
h
h
i
i
j
j
k
l
m
S
T
T
T
T
U
U
U
V
W
W
W
X2
X2
Y1
Y1
Y2
Y2
Y2
Z
Z
480V AC, 60 Hz
153H-WAB-42➎
153H-WAB-43➎
153H-WAB-44➎
153H-WAB-45➎
153H-WAB-46➎
153H-WBB-47
153H-WBB-48
153H-WBB-49
153H-WBB-50
153H-WBB-51
153H-WBB-52
153H-WBB-54
153H-WBB-56
153H-WBB-57
153H-WBB-58
153H-WBB-59
153H-WBB-60
153H-WBB-61
153H-WBB-62
153H-WBB-63
153H-WBB-65
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
450
500
600
700
800
1000
24
28
35
40
54
65
80
115
125
170
200
240
310
360
385
450
500
600
700
800
1000
a
b
b
c
c
d
d
e
e
f
g
g
h
h
i
i
i
j
k
l
m
S
T
T
T
T
U
U
V
V
W
W
X2
X2
Y1
Y1
Y2
Y2
Y2
Z
Z
Z
600V AC, 60 Hz
153H-WAC-43➎
153H-WAC-44➎
153H-WAC-45➎
153H-WAC-46➎
153H-WAC-47➎
153H-WBC-48
153H-WBC-49
153H-WBC-50
153H-WBC-51
153H-WBC-52
153H-WBC-54
153H-WBC-56
153H-WBC-57
153H-WBC-58
153H-WBC-59
153H-WBC-60
153H-WBC-61
153H-WBC-62
153H-WBC-63
153H-WBC-65
153H-WBC-67
➊
➋
➌
➍
IP54 (Type 12) Enclosed Combination
Controller
With Circuit Breaker and Bypass Contactor ➋
Dimension Code
Cat. No. ➌➍
S
T
T
T
T
U
U
U
V
W
W
W
X
X
Y1
Y1
Z
Z
Z
Z
Y3
153H-WJB-42➏
153H-WJB-43➏
153H-WJB-44➏
153H-WJB-45➏
153H-WJB-46➏
153H-WJB-47
153H-WJB-48
153H-WJB-49
153H-WJB-50
153H-WJB-51
153H-WJB-52
153H-WJB-54
153H-WJB-56
153H-WJB-57
153H-WJB-58
153H-WJB-59
153H-WJB-60
153H-WJB-61
153H-WJB-62
153H-WJB-63
153H-WJB-65
S
T
T
T
T
U
U
V
V
W
W
W
X
Y1
Y1
Z
Z
Z
Z
Y3
Y3
153H-WJC-43➏
153H-WJC-44➏
153H-WJC-45➏
153H-WJC-46➏
153H-WJC-47➏
153H-WJC-48
153H-WJC-49
153H-WJC-50
153H-WJC-51
153H-WJC-52
153H-WJC-54
153H-WJC-56
153H-WJC-57
153H-WJC-58
153H-WJC-59
153H-WJC-60
153H-WJC-61
153H-WJC-62
153H-WJC-63
153H-WJC-65
153H-WJC-67
208V and 240V Controllers are available. Consult Allen-Bradley Sales Office.
See page 56 for circuit breaker size and rating plug size.
Accu-Stop Control is not available when a bypass contactor is used.
Bypass contactors are used to bypass the SMC PLUS Controller when the motor has reached full speed.
➎ Includes internal circulating fan rather than enclosure ventilation.
➏ Includes internal circulating fan rather than bypass contactor.
0
Accessories — Page 49
Options — Page 50
Specifications — Page 56
Approximate Dimensions — Page 59
48
Bulletin 150
Smart Motor Controllers — SMC PLUS
Accessories
Protective Modules (Field Modifications) ➊ ➋
Nominal
Current
Rating (A)
24…54
97…360
Price Adder Code
Field Modification
Cat. No.
Description
480V Protective Module
150-N84
600V Protective Module
150-N86
480V Protective Module
150-N84L
600V Protective Module
150-N86L
a…c
d…h
Terminal Lug Kits (97…1000 A)
Total No. of
Terminal Lugs
Possible Each Side
Nominal
Current
Rating (A)
Conductor
Range
Line Side
Load Side
Pkg.
Qty.
Cat. No.
97…135
180…360
500
650…720
850…1000
#6-4/0 AWG
#6-4/0 AWG
#4-500MCM AWG
#4-500MCM AWG
(2) 1/0-500MCM AWG
3
6
6
9
6
3
6
6
9
6
3
3
3
3
3
199-LF1
199-LF1
199-LG1
199-LG1
199-LJ1
IEC Terminal Covers (Field Modification)
Description
Field Modification
Cat. No.
IEC line or load terminal covers for 97…135
A devices (includes line and load
termination covers)
150-NT1
IEC line and load terminal covers for
180…360 A devices (includes line and load
termination covers)
150-NT2
➊ The same protective module mounts on the line or load side of the SMC PLUS. For applications requiring both line and load side protection, two
protective modules must be ordered.
➋ Protective modules are standard on 500…1000 A units.
Product Selection — Page 43
49
Bulletin 150
Smart Motor Controllers — SMC PLUS
Options
SMC Easy Ship program descriptions are printed in blue. See page 39.
Option
Soft Stop ➊➋➌
Pump Control ➊➋
Preset Slow Speed ➊➋
Description
Provides a ramp down time of 2…60 seconds for applications which require
an extended coast-to-rest.
Provides smooth motor acceleration and deceleration, reducing surges
caused by the starting and stopping of centrifugal pumps. Starting time is
adjustable from 2…30 seconds, and stopping time is adjustable from 2…120
seconds.
Provides a preset slow speed for positioning or alignment applications.
Preset speeds can be selected at either 7% or 15% of rated motor speed, in
the forward direction, 10% or 20% in the reverse direction. The direction of
the motor is dip switch selectable. Slow speed current is adjustable from
50…450% of full load current.
SMB Smart Motor
Braking ➊➋➌
Provides a microcomputer based braking system which applies three-phase
braking current to a standard squirrel-cage induction motor. The strength of
the braking current is adjustable from 150…400% of full load motor current.
Accu-Stop ➊➋➌➎
Provides precise stopping control for positioning or to minimize jogging to
stop. A three-phase braking current is applied to the motor (adjustable from
150…400% of full load current) until it reaches a preset slow speed (either
7% or 15% of rated motor-speed). The motor is held at this speed until a
stop command is given. Braking torque is then applied until the motor
reaches zero speed. Slow speed current is adjustable from 50…450% of full
load current.
Slow Speed with
Braking ➊➋➌➏
Provides forward slow speed for positioning and alignment, and braking
control to stop.
Price Adder
Code
Cat. No.
Modification
a…m
A➍
a…m
B➍
a…m
C➍
a
b
c
d
e
f
g
h
i
j
k
l
m
a
b
c
d
e
f
g
h
i
j
k
l
m
a
b
c
d
e
f
g
h
i
j
k
l
m
➊ Only one option may be added to the standard unit.
➋ Observe the thermal rating of the AC induction motor.
➌ Not intended to be used as an emergency stop. Refer to the applicable standards for emergency stop requirements.
➍ Add the designated letter to the end of the Cat. No. For example, to add the Pump Control Option: Cat. No 150-24NBD becomes
Cat. No. 150-A24NBDB or Cat. No. 152B-WBB-56 becomes Cat. No. 152B-WBBB-56 for combination style.
➎ Accu-stop Control is not available when a bypass contactor is used.
➏ Kickstart is not available with this option.
Product Selection — Page 43
50
D➍
E➍
F➍
Bulletin 150
Smart Motor Controllers — SMC PLUS
Options, Continued
SMC Easy Ship program descriptions are printed in blue. See page 39.
Option
Push Buttons
Selector Switch
Pilot Lights
Control Circuit Transformer
Protective Modules ➌
Overload Relay ➍➎
External Overload
Relay Reset ➏
Overload Auxiliary Contact
Isolation
Contactor
➊
➋
➌
➍
➎
➏
➐
Description
Start-Stop Push Button
Start-Stop Push Button with H-O-A Selector Switch
Soft Stop Push Button ➊
Pump Stop Push Button ➊
Slow Speed Push Button ➊
Brake Push Button ➊
Accu-Stop/Slow Speed Push Button ➊
Emergency Stop
Fault Reset
Hand-Off-Auto Selector Switch
SMC-Off-Bypass Selector Switch
Forward-Off-Reverse Selector Switch
Transformer Pilot Light (Red Lens — Easy Ship Program) ➋
Push-to-Test Pilot Light ➋
Control Circuit Transformer (fused primary and secondary)
Additional 100 VA Control Circuit Transformer (fused primary and
24…54 A, 480V Line Side Protective Module
97…360 A, 480V Line Side Protective Module
24…54 A, 600V Line Side Protective Module
97…360 A, 600V Line Side Protective Module
24…54 A, 480V Load Side Protective Module
97…360 A, 480V Load Side Protective Module
24…54 A, 600V Load Side Protective Module
97…360 A, 600V Load Side Protective Module
24…54 A, 480V Both Line and Load Side Protective Modules
97…360 A, 480V Both Line and Load Side Protective Modules
24…54 A, 600V Both Line and Load Side Protective Modules
97…360 A, 600V Both Line and Load Side Protective Modules
Three-pole thermal overload relay for 24…35 A units
Three-pole thermal overload relay for 54 A units
Three-pole thermal overload relay for 97…135 A units
Three-pole thermal overload relay for 180…360 A units
Three-pole thermal overload relay for 500 units
Three-pole thermal overload relay for 650…850 A units
Three-pole thermal overload relay for 1000 A units
24…54 A Overload Relay Reset
97…240 A Overload Relay Reset
360…1000 A Overload Relay Reset
N.O. Overload Relay Auxiliary Contact
N.C. Overload Relay Auxiliary Contact
Isolation Contactor
Price Adder
Code
a...m
a...m
a...m
a...m
a...c
d...h
a...c
d...h
a...c
d...h
a...c
d...h
a...c
d...h
a...c
d...h
a...b
c
d...e
f...h
i
j...l
m
a...c
d...g
h...m
Cat. No.
Modification
-1
-1F
-1XA
-1XB
-1XC
-1XD
-1XE
-1E
-FR
-3
-3B
-3R
-4_
-5_
-6P
-6PX
-8L4
-8L6
-8M4
-8M6
-8B4
-8B6
-OL
-7
a...m
-9
-9A
a...d
e...f
g
h
i
j
k...l
m
➐
Option push buttons are only available when the corresponding option module is selected. For example, Cat. No. 150-A24JBDA-1XA.
Specify pilot light lens color. Options: Amber, Blue, Clear, Green, Red, and White. For example, -4R for a red lens.
Line and Load Side Protective Modules are standard on 500…1000 A units.
Three-pole thermal overload for Bulletin 150 enclosed controllers only. Overload is standard on Bulletins 152 and 153.
Three-pole thermal overload does not include heater elements.
External Overload Relay Reset is available with Bulletins 152, 153, and enclosed Bulletin 150 devices with overload option only.
To order a non-combination or combination enclosed controller with an isolator contactor, add the letter “B” to the bulletin prefix. See
pages 36-37. Bulletin 100 contactors are used through 600 A. Enclosure dimensions are subject to change. Consult factory for dimensions.
51
Bulletin 150
Smart Motor Controllers — SMC PLUS
Options, Continued
Option
Reversing Contactor
NEMA Bypass
Contactor ➋
NEMA Isolation
Contactor ➋
Power Factor
Correction
Capacitors ➌
Description
Reversing Contactor
NEMA Bypass for 24…97 A unit
NEMA Bypass for 135…180 A unit
NEMA Bypass for 240 A unit
NEMA Bypass for 360 A unit
NEMA Bypass for 500 A unit
NEMA Bypass for 650 A unit
NEMA Bypass for 24…97 A unit
NEMA Bypass for 135…180 A unit
NEMA Bypass for 240 A unit
NEMA Bypass for 360 A unit
NEMA Bypass for 500 A unit
NEMA Bypass for 650 A unit
2 kVAR
2.5 kVAR
3 kVAR
4 kVAR
5 kVAR
6 kVAR
7 kVAR
7.5 kVAR
8 kVAR
9 kVAR
10 kVAR
11 kVAR
12.5 kVAR
14 kVAR
15 kVAR
16 kVAR
17.5 kVAR
18 kVAR
20 kVAR
22.5 kVAR
25 kVAR
27.5 kVAR
30 kVAR
32.5 kVAR
35 kVAR
37.5 kVAR
40 kVAR
42.5 kVAR
45 kVAR
47.5 kVAR
50 kVAR
Price Adder
Code
a...d
e...f
g
h
i
j
k...l
m
a…d
e…f
g
h
i
j
a…d
e…f
g
h
i
j
Cat. No.
Modification
➊
-NB
-NI
-PFCC➍
➊ To order a non-combination or combination enclosed controller with a reversing contactor, add an “R” to the bulletin prefix. See pages 41…42.
Bulletin 104 contactors are used through 500 A @ 480V. Enclosure dimensions are subject to change. Consult factory for dimensions.
➋ 720, 850, 1000 A units currently use a NEMA Contactor.
➌ Power Factor Correction Capacitor to include Power Capacitors with 3-phase Class J Time-Delay Fusing and appropriately sized contactor.
➍ To order Power Factor Correction Capacitors indicate kVAR rating. For example: -PFCC30kVAR.
Product Selection — Page 43
Accessories — Page 49
Specifications — Page 56
Approximate Dimensions — Page 59
52
Bulletin 150
Smart Motor Controllers — SMC PLUS
Options, Continued
Option
Power Factor
Correction Contactor ➊
SCR Fusing
Panel Board Type Ammeter
Panel Board Type Voltmeter
Elapsed Time Meter
Unwired Control Relays ➋
Control Relays
Auxiliary Contacts ➌
Disconnect Auxiliary ➍
Circuit Breaker
Disconnect Auxiliary ➎
High Interrupting
Circuit Breaker
Description
Power Factor Correction Capacitor Contactor
Fast acting current limiting SCR fusing for 24 A unit
Fast acting current limiting SCR fusing for 35 A unit
Fast acting current limiting SCR fusing for 54 A unit
Fast acting current limiting SCR fusing for 97…135 A units
Fast acting current limiting SCR fusing for 180 A unit
Fast acting current limiting SCR fusing for 240 A unit
Fast acting current limiting SCR fusing for 360 A unit
Fast acting current limiting SCR fusing for 500 A unit
Fast acting current limiting SCR fusing for 650…720 A units
Fast acting current limiting SCR fusing for 850 A unit
Fast acting current limiting SCR fusing for 1000 A unit
Single-phase panel board type ammeter for 24 A units
Single-phase panel board type ammeter for 35…97 A units
Single-phase panel board type ammeter for 135…240 A units
Single-phase panel board type ammeter for 360 A units
Single-phase panel board type ammeter for 500…650 A units
Single-phase panel board type ammeter for 720…1000 A units
Panel board type ammeter with switch for monitoring all three phases
Single-phase panel board type voltmeter
Panel board type voltmeter with switch for monitoring all three phases.
Elapsed time meter
Bulletin 700CF 4-pole relay – 2 N.O. and 2 N.C.
Bulletin 700CF 4-pole relay – 3 N.O. and 1 N.C.
Bulletin 700CF 4-pole relay – 4 N.O.
On-Delay
Off-Delay
N.O. auxiliary contacts for 24…240 A units
N.O. auxiliary contacts for 360…1000 A units
N.C. auxiliary contacts for 24…240 A units
N.C. auxiliary contacts for 360…1000 A units
1 N.O. ... 1 N.C. auxiliary contacts for 24...240 A units
1 N.O. ... 1 N.C. auxiliary contacts for 360...1000 A units
N.O. disconnect auxiliary mounted on operating mechanism
N.C. disconnect auxiliary mounted on operating mechanism
Internal N.O. circuit breaker auxiliary
Internal N.C. circuit breaker auxiliary
High Interrupting Circuit Breaker for 24...54 A units
High Interrupting Circuit Breaker for 97...180 A units
High Interrupting Circuit Breaker for 240 A units
High Interrupting Circuit Breaker for 360 A units
High Interrupting Circuit Breaker for 500 A units
High Interrupting Circuit Breaker for 650...720 A units
High Interrupting Circuit Breaker for 850...1000 A units
Price Adder
Code
a...d
e...f
g
h
i
j
a
b
c
d...e
f
g
h
i
j...k
l
m
a
b...d
e...g
h
i...j
k...m
a...m
a...m
a...m
a...m
a...h
a...g
h...m
a...g
h...m
a...g
h...m
a...m
a...m
a...c
d...f
g
h
i
j...k
l...m
Cat. No.
Modification
-PFCCC
-SCR
-85AA
-86AA
-85AV
-86AV
-85T
-89F22
-89F31
-89F40
-89FOD
-89FOFD
-90
-91
-901
-98
-99
-98X
-99X
-HICB
➊ Only the contactor will be provided. For motor horsepower above 500 consult factory for sizing and pricing.
➋ Instantaneous auxiliary contacts on Bulletin 700F relays are non-convertible.
➌ Available only with enclosed Bulletin 150, 152 and 153 devices with an isolation contactor or bypass contactor. Maximum of four (4) auxiliary
contacts.
➍ Available only with Bulletin 152 and 153 devices. Maximum of two (2) disconnect auxiliaries.
➎ Available only with Bulletin 153 devices. Maximum of two (2) disconnect auxiliaries.
Product Selection — Page 43
53
Bulletin 150
Smart Motor Controllers — SMC PLUS
Options, Continued
Option
Shunt Trip ➊
Additional Load
Circuit Breakers ➋
Line Voltage Monitor
Thermistor Protection Relay
Smart Motor Manager
IQ1000 Protective Relay
Multilin 269 Plus
Transducer Output
Ground Fault Protection
Description
Circuit Breaker Shunt Trip for 24…54 A units
Circuit Breaker Shunt Trip for 97…135 A units
Circuit Breaker Shunt Trip for 180…240 A units
Circuit Breaker Shunt Trip for 360…500 A units
Circuit Breaker Shunt Trip for 650…850 A units
Circuit Breaker Shunt Trip for 1000 A units
Additional load circuit breakers to be installed in panel. Customer is to
stipulate size and quantity.
Bulletin 813S Line Voltage Monitor
Bulletin 817 Thermistor Protection Relay
Bulletin 825 Smart Motor Manager and Bulletin 825 Converter Module
Cutler-Hammer IQ1000 Protective Relay
GE Multilin 269 Plus Protective Relay
4…20 mA output signal proportional to 1…100% motor FLC
Bulletin 1409 Arcing Ground Fault Relay and Sensor for applications up to
400 HP
Motor Winding Heater ➋
Bulletin 1410 Motor Winding Heater for applications up to 600 HP
Lightning Arrestor
Strip Heater
Lightning Surge Protection
Cabinet Strip Heater with Thermostat
Service Entrance Label
Service Entrance Label
Price Adder
Code
Cat. No.
Modification
a...c
d...e
f...g
h...i
j...l
m
-754
a...m
-ALCB
a...m
a...m
a...m
a...m
a...m
a...m
-813S
-817
-SMM
-IQ1000
-269PLUS
-TO
a...i
-GFP
a...e
f…g
h…i
j…k
a...m
a...m
a...j
k…l
a...m
-MWH
-LA
-SH
-SEL
U.L. Label
U.L. Label
Unwired Terminal Blocks
Panel Mounted Unwired Terminal Blocks
6 or 12 position
a...m
Components mounted on enclosure mounting plate only
Customer is to stipulate panel dimensions
a...m
a...m
-UL
-TB6
-TB12
-PM
-SPD
Panel Mount ➌
Specified Panel Dimensions ➌
Enclosure Color
(Custom Paint) ➌
Enclosure Shock Mounts ➌
Customer is to stipulate paint color for enclosure
a...m
-EC
Ship Board – MIL-S-901D
-SM
Enclosure Type NEMA 3R ➍
Enclosure Type NEMA 3R Non-Combination
Enclosure Type NEMA 3R ➍
Enclosure Type NEMA 3R Combination
a...m
a…c
d…e
f…h
i…m
a…c
d…e
f…h
i…m
➊
➋
➌
➍
➎
➎
Available only with Bulletin 153 devices.
Requires an isolation contactor on the output of the SMC.
Pricing to be determined upon request.
To order a non-combination or combination enclosed controller with a NEMA 3R enclosure, add an “H” to the enclosure type prefix. Example:
Cat. No. 152H-B240HBD-54. See pages 41…42. Enclosure dimensions are subject to change. Consult factory for dimensions. Enclosure price
adder is to be added to NEMA 12 non-combination or combination price.
➎ Consult factory for pricing.
Product Selection — Page 43
Accessories — Page 49
Specifications — Page 56
Approximate Dimensions — Page 59
54
Bulletin 150
Smart Motor Controllers — SMC PLUS
Options, Continued
Option
Description
Enclosure Type NEMA 4X
Stainless Steel ➊
Enclosure Type NEMA 4X Stainless Steel Non-Combination
Enclosure Type NEMA 4X
Stainless Steel ➊
Enclosure Type NEMA 4X Stainless Steel Combination
Air Conditioning ➋
Wiring Diagrams
Print Approval ➌
AC Unit mounted on enclosure
AutoCad Drawing of panel wiring
Customer Requested Print Approval Drawings
Price Adder
Code
a…d
e…f
g…h
i…m
a…c
d…e
f…h
i…m
a...m
a...m
a...m
Cat. No.
Modification
➍
➍
-AC
-WD
-PA
➊ To order a non-combination or combination enclosed controller with a NEMA 4X stainless steel enclosure, add an “S” to the enclosure type prefix.
Example: Cat. No 152H-B240SBD-54. See pages 41…42. Enclosure dimensions are subject to change. Consult factory for dimensions.
Enclosure price adder is to be added to the NEMA 12 non-combination or combination price.
➋ Pricing to be determined upon request.
➌ Order to be released to manufacturing upon return of signed approval drawing.
➍ Consult factory for pricing.
Product Selection — Page 43
Accessories — Page 49
Specifications — Page 56
Approximate Dimensions — Page 59
55