Bulletin 150 Smart Motor Controllers — SMC PLUS Product Selection Open Type Controllers Up to 480V AC kW ➊ HP ➋ Current Rating (A) 230V AC 50 Hz 400V AC 50 Hz 200V AC 60 Hz 230V AC 60 Hz 460V AC 60 Hz Cat. No. ➌ Price Adder Code 24 5.5 11 1…5 1…7.5 1…15 150-A24NBD a 35 54 10 15 18.5 22 1…10 1…15 1…10 1…20 1…25 1…40 150-A35NBD 150-A54NBD b c 97 135 25 37 45 75 5…30 5…40 5…30 5…50 5…75 5…100 150-A97NBD 150-A135NBD d e 180 240 51 75 90 132 5…60 5…75 5…60 5…75 5…150 5…200 150-A180NBD 150-A240NBD f g 360 500 110 150 200 257 5…125 5…150 5…150 5…200 5…300 5…400 150-A360NBD 150-A500NBD h i 650 200 355 5…200 5…250 5…500 150-A650NBD j 720 850 220 257 400 475 5…250 10…300 5…300 10…350 5…600 10…700 150-A720NBD 150-A850NBD k l 1000 315 530 10…350 10…400 10…800 150-A1000NBD m Up to 600V AC kW ➊ HP ➋ Cat. No. ➌ Price Adder Code 24 5.5 11 15 1…5 1…7.5 1…15 1…20 150-A24NCD a 35 54 10 15 18.5 22 22 37 1…10 1…15 1…10 1…20 1…25 1…40 1…30 1…50 150-A35NCD 150-A54NCD b c 97 135 25 37 45 75 63 90 5…30 5…40 5…30 5…50 5…75 5…100 5…75 5…125 150-A97NCD 150-A135NCD d e 180 240 51 75 90 132 132 160 5…60 5…75 5…60 5…75 5…150 5…200 5…150 5…250 150-A180NCD 150-A240NCD f g 360 500 110 150 200 257 250 355 5…125 5…150 5…150 5…200 5…300 5…400 5…350 5…500 150-A360NCD 150-A500NCD h i 650 720 200 220 355 400 475 500 5…200 5…250 5…250 5…300 5…500 5…600 5…600 5…700 150-A650NCD 150-A720NCD j k 850 1000 257 315 475 530 600 710 10…300 10…350 10…350 10…400 10…700 10…800 10…800 10…1000 150-A850NCD 150-A1000NCD l m Current Rating (A) 230V AC 50 400V AC 50 500V AC 50 200V AC 60 230V AC 60 460V AC 60 575V AC 60 Hz Hz Hz Hz Hz Hz Hz ➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated 850 A and greater. ➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively. ➌ Controllers are shipped from the factory preset for soft start mode, 10 s acceleration, energy saver inactive, motor stall inactive, and control power 100…240V AC, 50/60 Hz. Accessories — Page 49 Options — Page 50 Specifications — Page 57 Approximate Dimensions — Page 59 43 Bulletin 150 Smart Motor Controllers — SMC PLUS Product Selection, Continued IP30 (Type 1) Enclosed Non-Combination Controllers SMC Easy Ship program Cat. Nos. are printed in blue. See page 39. Bulletin 150 (Non-Combination Controller) — The SMC PLUS Controller requires a separate 100…240V, 50/60 Hz single-phase control source. A thermal overload is not included. Terminals are provided for a separate thermal overload relay connection to the control circuit. Enclosures other than those listed are available. Consult Allen-Bradley Sales Office. Up to 480V AC kW ➊ HP ➋ Cat. No. ➌ Dimension Code Price Adder Code 1…15 150-A24JBD Q a 1…25 1…40 150-A35JBD 150-A54JBD Q Q b c 5…75 5…100 150-A97BBD 150-A135BBD R T d e 5…60 5…75 5…150 5…200 150-A180BBD 150-A240BBD T T f g 5…125 5…150 5…300 150-A360BBD U h 5…150 5…200 5…200 5…250 5…400 5…500 150-A500BBD 150-A650BBD W X i j 400 450 5…250 10…300 5…300 10…350 5…600 10…700 150-A720BBD 150-A850BBD X X k l 500 10…350 10…400 10…800 150-A1000BBD X m Current Rating (A) 230V AC 50 Hz 400V AC 50 Hz 24 5.5 35 54 10 15 97 135 200V AC 60 Hz 230V AC 60 Hz 460V AC 60 Hz 11 1…5 15 22 1…10 1…15 1…7.5 1…10 1…20 25 37 45 55 5…30 5…40 5…30 5…50 180 240 51 75 90 110 5…60 5…75 360 500 650 110 200 150 200 250 355 720 850 220 257 1000 315 Up to 600V AC kW ➊ Current Rating (A) 230V AC 50 Hz 24 35 54 HP ➋ Cat. No. ➌ Dimension Code Price Adder Code 1…20 150-A24JCD Q a 1…30 1…50 150-A35JCD 150-A54JCD Q Q b c 5…75 5…100 5…75 5…125 150-A97BCD 150-A135BCD R T d e 5…60 5…75 5…150 5…200 5…150 5…250 150-A180BCD 150-A240BCD T T f g 5…125 5…150 5…150 5…200 5…300 5…400 5…350 5…500 150-A360BCD 150-A500BCD U W h i 475 500 5…200 5…250 5…250 5…300 5…500 5…600 5…600 5…700 150-A650BCD 150-A720BCD X X j k 475 600 10…300 10…350 10…700 10…800 150-A850BCD X l 530 710 10…350 10…400 10…800 10…1000 150-A1000BCD X m 400V AC 50 Hz 500V AC 50 Hz 200V AC 60 Hz 230V AC 60 Hz 460V AC 60 Hz 575V AC 60 Hz 5.5 11 10 15 18.5 22 15 1…5 1…7.5 1…15 22 37 1…10 1…15 1…10 1…20 1…25 1…40 97 135 25 37 45 75 63 90 5…30 5…40 5…30 5…50 180 240 51 75 90 132 132 160 5…60 5…75 360 500 110 150 200 257 250 355 650 720 200 220 355 400 850 257 1000 315 ➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated 850 A and greater. ➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively. ➌ Controllers are shipped from the factory preset for soft start mode, 10 second acceleration, energy saver inactive, motor stall active, and control power 100…240V AC, 50/60 Hz. Accessories — Page 49 Options — Page 50 Specifications — Page 56 Approximate Dimensions — Page 59 44 Bulletin 150 Smart Motor Controllers — SMC PLUS Product Selection, Continued IP65 (Type 4) Enclosed Non-Combination Controllers Bulletin 150 (Non-Combination Controller) — The SMC PLUS Controller requires a separate 100…240V, 50/60 Hz single-phase control source. A thermal overload is not included. Terminals are provided for a separate thermal overload relay connection to the control circuit. Enclosures other than those listed are available. Consult Allen-Bradley Sales Office. Up to 480V AC kW ➊ HP ➋ Current Rating (A) 230V AC 50 Hz 400V AC 50 Hz 200V AC 60 Hz 230V AC 60 Hz 460V AC 60 Hz 24 35 5.5 10 11 18.5 1…5 1…10 1…7.5 1…10 1…15 1…25 54 97 15 25 22 45 1…15 5…30 1…20 5…30 135 180 37 51 75 90 5…40 5…60 240 360 75 110 132 200 500 150 650 720 200 220 850 1000 257 315 Cat. No. ➌➍ Dimension Code Price Adder Code 150-A24FBD 150-A35FBD Q Q a b 1…40 5…75 150-A54FBD 150-A97FBD Q S c d 5…50 5…60 5…100 5…150 150-A135FBD 150-A180FBD T T e f 5…75 5…125 5…75 5…150 5…200 5…300 150-A240FBD 150-A360FBD U V g h 257 5…150 5…200 5…400 150-A500FBD X i 355 400 5…200 5…250 5…250 5…300 5…500 5…600 150-A650FBD 150-A720FBD Z1 Z1 j k 475 530 10…300 10…350 10…350 10…400 10…700 10…800 150-A850FBD 150-A1000FBD Z1 Z1 l m Up to 600V AC kW ➊ HP ➋ Cat. No. ➌➍ Dimension Code Price Adder Code 150-A24FCD 150-A35FCD Q Q a b 1…50 5…75 150-A54FCD 150-A97FCD Q S c d 5…100 5…150 5…125 5…150 150-A135FCD 150-A180FCD T T e f 5…75 5…150 5…200 5…300 5…250 5…350 150-A240FCD 150-A360FCD V V g h 5…150 5…200 5…200 5…250 5…400 5…500 5…500 5…600 150-A500FCD 150-A650FCD X Z1 i j 500 600 5…250 10…300 5…300 10…350 5…600 10…700 5…700 10…800 150-A720FCD 150-A850FCD Z1 Z1 k l 710 10…350 10…400 10…800 10…1000 150-A1000FCD Z1 m Current Rating (A) 230V AC 50 Hz 400V AC 50 Hz 500V AC 50 Hz 200V AC 60 Hz 230V AC 60 Hz 460V AC 60 Hz 575V AC 60 Hz 24 35 5.5 10 11 18.5 15 22 1…5 1…10 1…7.5 1…10 1…15 1…25 1…20 1…30 54 97 15 25 22 45 37 63 1…15 5…30 1…20 5…30 1…40 5…75 135 180 37 51 75 90 90 132 5…40 5…60 5…50 5…60 240 360 75 110 132 200 160 250 5…75 5…125 500 650 150 200 257 355 355 475 720 850 220 257 400 475 1000 315 530 ➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated 850 A and greater. ➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively. ➌ Controllers are shipped from the factory preset for soft start mode, 10 second acceleration, energy saver inactive, motor stall inactive, and control power 100…240V AC, 50/60 Hz. ➍ 97…1000 A Type 4 SMC PLUS Smart Motor Controllers include Bulletin 100 bypass contactors wired for 120V AC 50/60 Hz. Accessories — Page 49 Options — Page 50 Specifications — Page 56 Approximate Dimensions — Page 59 45 Bulletin 150 Smart Motor Controllers — SMC PLUS Product Selection, Continued IP54 (Type 12) Enclosed Non-Combination Controllers SMC Easy Ship program Cat. Nos. are printed in blue. See page 39. Bulletin 150 (Non-Combination Controller) — The SMC PLUS Controller requires a separate 100…240V, 50/60 Hz single-phase control source. A thermal overload is not included. Terminals are provided for a separate thermal overload relay connection to the control circuit. Enclosures other than those listed are available. Consult Allen-Bradley Sales Office. Up to 480V AC kW ➊ Current Rating (A) 230V AC 50 Hz 24 5.5 35 54 10 15 97 135 25 37 180 240 HP ➋ Cat. No. ➌➍ Dimension Code Price Adder Code 1…15 150-A24JBD Q a 1…25 1…40 150-A35JBD 150-A54JBD Q Q b c 5…75 5…100 150-A97JBD 150-A135JBD S T d e 5…60 5…75 5…150 5…200 150-A180JBD 150-A240JBD T U f g 5…125 5…150 5…300 150-A360JBD V h 5…150 5…200 5…200 5…250 5…400 5…500 150-A500JBD 150-A650JBD X Z i j 400 475 5…250 10…300 5…300 10…350 5…600 10…700 150-A720JBD 150-A850JBD Z1 Z1 k l 530 10…350 10…400 10…800 150-A1000JBD Z1 m 400V AC 50 Hz 200V AC 60 Hz 230V AC 60 Hz 460V AC 60 Hz 11 1…5 18.5 22 1…10 1…15 1…7.5 1…10 1…20 45 75 5…30 5…40 5…30 5…50 51 75 90 132 5…60 5…75 360 500 650 150 200 132 200 257 355 720 850 220 257 1000 315 Up to 600V AC kW ➊ Current Rating (A) 230V AC 50 Hz 24 5.5 11 35 54 10 15 18.5 22 97 135 25 37 45 75 180 240 51 75 360 500 400V AC 50 Hz HP ➋ Cat. No. ➌➍ Dimension Code Price Adder Code 1…20 150-A24JCD Q a 1…30 1…50 150-A35JCD 150-A54JCD Q Q b c 5…75 5…125 150-A97JCD 150-A135JCD S T d e 5…150 5…200 5…150 5…250 150-A180JCD 150-A240JCD T V f g 5…150 5…200 5…300 5…400 5…350 5…500 150-A360JCD 150-A500JCD V X h i 5…200 5…250 5…250 5…300 5…500 5…600 5…600 5…700 150-A650JCD 150-A720JCD Z Z1 j k 600 10…300 10…350 10…700 10…800 150-A850JCD Z1 l 710 10…350 10…400 10…800 10…1000 150-A1000JCD Z1 m 500V AC 50 Hz 200V AC 60 Hz 230V AC 60 Hz 15 1…5 1…7.5 22 37 1…10 1…15 1…10 1…20 63 90 5…30 5…40 5…30 5…50 90 132 110 160 5…60 5…75 110 150 200 257 250 355 650 720 200 220 355 400 850 257 1000 315 460V AC 60 Hz 575V AC 60 Hz 1…15 1…25 1…40 5…75 5…100 5…60 5…75 5…125 5…150 475 500 475 530 ➊ The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated 850 A and greater. ➋ HP ratings at motor terminal voltages for 208, 480 and 600 line volts, respectively. ➌ Controllers are shipped from the factory preset for soft start mode, 10 second acceleration, energy saver inactive, motor stall inactive, and control power 100…240V AC, 50/60 Hz. ➍ 97…1000 A Type 12 SMC PLUS Smart Motor Controllers include Bulletin 100 Bypass Contactors wired for 120V AC 50/60 Hz. Accessories — Page 49 Options — Page 50 Specifications — Page 56 Approximate Dimensions — Page 59 46 Bulletin 150 Smart Motor Controllers — SMC PLUS Product Selection, Continued Enclosed Combination Controllers ➊ Bulletin 152H/153H (Combination Controller) — Includes a 120V control transformer and a three-pole thermal overload relay less elements. Where isolating or bypass contactors are required, Bulletin 100 contactors are used (through 600 A). Enclosures other than those listed are available. Consult Allen-Bradley Sales Office. HP Nominal Current (A) Price Adder Code IP30 (Type 1) Vented Enclosure With Fusible Disconnect ➋ Dimension Code Cat. No. IP54 (Type 12) Enclosed Combination Controller With Fusible Disconnect and Bypass Contactor ➋ Dimension Code Cat. No. ➌➍ S T T T T U U U V W W W X2 X2 Y2 Y2 Z2 Z2 Z2 Z3 Z3 152H-WJB-42➏ 152H-WJB-43➏ 152H-WJB-44➏ 152H-WJB-45➏ 152H-WJB-46➏ 152H-WJB-47 152H-WJB-48 152H-WJB-49 152H-WJB-50 152H-WJB-51 152H-WJB-52 152H-WJB-54 152H-WJB-56 152H-WJB-57 152H-WJB-58 152H-WJB-59 152H-WJB-60 152H-WJB-61 152H-WJB-62 152H-WJB-63 152H-WJB-65 S T T T T U U V V W W X2 X2 Y2 Y2 Z2 Z2 Z2 Z3 Z3 Z3 152H-WJC-43➏ 152H-WJC-44➏ 152H-WJC-45➏ 152H-WJC-46➏ 152H-WJC-47➏ 152H-WJC-48 152H-WJC-49 152H-WJC-50 152H-WJC-51 152H-WJC-52 152H-WJC-54 152H-WJC-56 152H-WJC-57 152H-WJC-58 152H-WJC-59 152H-WJC-60 152H-WJC-61 152H-WJC-62 152H-WJC-63 152H-WJC-65 152H-WJC-67 480V AC, 60 Hz 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 800 24 30 35 40 54 70 82 97 125 156 180 240 302 360 410 477 525 575 675 800 915 a b b c c d d d e f f g h h i i j j k l m S T T T T U U U V W W W X2 X2 Y1 Y1 Z1 Z1 Z1 Z1 Z1 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 800 1000 24 28 35 40 54 65 80 115 125 170 200 240 310 360 385 450 500 600 700 800 1000 a b b c c d d e e f g g h h i i i j k l m S T T T T U U V V W W X2 X2 Y1 Y1 Z1 Z1 Z1 Z1 Z1 Z1 152H-WAB-42➎ 152H-WAB-43➎ 152H-WAB-44➎ 152H-WAB-45➎ 152H-WAB-46➎ 152H-WBB-47 152H-WBB-48 152H-WBB-49 152H-WBB-50 152H-WBB-51 152H-WBB-52 152H-WBB-54 152H-WBB-56 152H-WBB-57 152H-WBB-58 152H-WBB-59 152H-WBB-60 152H-WBB-61 152H-WBB-62 152H-WBB-63 152H-WBB-65 600V AC, 60 Hz ➊ ➋ ➌ ➍ ➎ ➏ 152H-WAC-43➎ 152H-WAC-44➎ 152H-WAC-45➎ 152H-WAC-46➎ 152H-WAC-47➎ 152H-WBC-48 152H-WBC-49 152H-WBC-50 152H-WBC-51 152H-WBC-52 152H-WBC-54 152H-WBC-56 152H-WBC-57 152H-WBC-58 152H-WBC-59 152H-WBC-60 152H-WBC-61 152H-WBC-62 152H-WBC-63 152H-WBC-65 152H-WBC-67 208V and 240V Controllers are available. Consult Allen-Bradley Sales Office. See page 56 for fuse clip size and type information. Accu-Stop Control is not available when a bypass contactor is used. Bypass contactors are used to bypass the SMC PLUS Controller when the motor has reached full speed. Includes internal circulating fan rather than enclosure ventilation. Includes internal circulating fan rather than bypass contactor. Accessories — Page 49 Options — Page 50 Specifications — Page 56 Approximate Dimensions — Page 59 47 Bulletin 150 Smart Motor Controllers — SMC PLUS Product Selection, Continued Enclosed Combination Controllers ➊ SMC Easy Ship program Cat. Nos. are printed in blue. See page 39. Bulletin 152H/153H (Combination Controller) — Includes a 120V control transformer and a three-pole thermal overload relay less elements. Where isolating or bypass contactors are required, Bulletin 100 contactors are used (through 600 A). Enclosures other than those listed are available. Consult Allen-Bradley Sales Office. HP Nominal Current Price Adder Code IP30 (Type 1) Vented Enclosed Combination Controllers With Circuit Breaker ➋ Dimension Code Cat. No. 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 800 24 30 35 40 54 70 82 97 125 156 180 240 302 360 410 477 525 575 675 800 915 a b b c c d d d e f f g h h i i j j k l m S T T T T U U U V W W W X2 X2 Y1 Y1 Y2 Y2 Y2 Z Z 480V AC, 60 Hz 153H-WAB-42➎ 153H-WAB-43➎ 153H-WAB-44➎ 153H-WAB-45➎ 153H-WAB-46➎ 153H-WBB-47 153H-WBB-48 153H-WBB-49 153H-WBB-50 153H-WBB-51 153H-WBB-52 153H-WBB-54 153H-WBB-56 153H-WBB-57 153H-WBB-58 153H-WBB-59 153H-WBB-60 153H-WBB-61 153H-WBB-62 153H-WBB-63 153H-WBB-65 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 800 1000 24 28 35 40 54 65 80 115 125 170 200 240 310 360 385 450 500 600 700 800 1000 a b b c c d d e e f g g h h i i i j k l m S T T T T U U V V W W X2 X2 Y1 Y1 Y2 Y2 Y2 Z Z Z 600V AC, 60 Hz 153H-WAC-43➎ 153H-WAC-44➎ 153H-WAC-45➎ 153H-WAC-46➎ 153H-WAC-47➎ 153H-WBC-48 153H-WBC-49 153H-WBC-50 153H-WBC-51 153H-WBC-52 153H-WBC-54 153H-WBC-56 153H-WBC-57 153H-WBC-58 153H-WBC-59 153H-WBC-60 153H-WBC-61 153H-WBC-62 153H-WBC-63 153H-WBC-65 153H-WBC-67 ➊ ➋ ➌ ➍ IP54 (Type 12) Enclosed Combination Controller With Circuit Breaker and Bypass Contactor ➋ Dimension Code Cat. No. ➌➍ S T T T T U U U V W W W X X Y1 Y1 Z Z Z Z Y3 153H-WJB-42➏ 153H-WJB-43➏ 153H-WJB-44➏ 153H-WJB-45➏ 153H-WJB-46➏ 153H-WJB-47 153H-WJB-48 153H-WJB-49 153H-WJB-50 153H-WJB-51 153H-WJB-52 153H-WJB-54 153H-WJB-56 153H-WJB-57 153H-WJB-58 153H-WJB-59 153H-WJB-60 153H-WJB-61 153H-WJB-62 153H-WJB-63 153H-WJB-65 S T T T T U U V V W W W X Y1 Y1 Z Z Z Z Y3 Y3 153H-WJC-43➏ 153H-WJC-44➏ 153H-WJC-45➏ 153H-WJC-46➏ 153H-WJC-47➏ 153H-WJC-48 153H-WJC-49 153H-WJC-50 153H-WJC-51 153H-WJC-52 153H-WJC-54 153H-WJC-56 153H-WJC-57 153H-WJC-58 153H-WJC-59 153H-WJC-60 153H-WJC-61 153H-WJC-62 153H-WJC-63 153H-WJC-65 153H-WJC-67 208V and 240V Controllers are available. Consult Allen-Bradley Sales Office. See page 56 for circuit breaker size and rating plug size. Accu-Stop Control is not available when a bypass contactor is used. Bypass contactors are used to bypass the SMC PLUS Controller when the motor has reached full speed. ➎ Includes internal circulating fan rather than enclosure ventilation. ➏ Includes internal circulating fan rather than bypass contactor. 0 Accessories — Page 49 Options — Page 50 Specifications — Page 56 Approximate Dimensions — Page 59 48 Bulletin 150 Smart Motor Controllers — SMC PLUS Accessories Protective Modules (Field Modifications) ➊ ➋ Nominal Current Rating (A) 24…54 97…360 Price Adder Code Field Modification Cat. No. Description 480V Protective Module 150-N84 600V Protective Module 150-N86 480V Protective Module 150-N84L 600V Protective Module 150-N86L a…c d…h Terminal Lug Kits (97…1000 A) Total No. of Terminal Lugs Possible Each Side Nominal Current Rating (A) Conductor Range Line Side Load Side Pkg. Qty. Cat. No. 97…135 180…360 500 650…720 850…1000 #6-4/0 AWG #6-4/0 AWG #4-500MCM AWG #4-500MCM AWG (2) 1/0-500MCM AWG 3 6 6 9 6 3 6 6 9 6 3 3 3 3 3 199-LF1 199-LF1 199-LG1 199-LG1 199-LJ1 IEC Terminal Covers (Field Modification) Description Field Modification Cat. No. IEC line or load terminal covers for 97…135 A devices (includes line and load termination covers) 150-NT1 IEC line and load terminal covers for 180…360 A devices (includes line and load termination covers) 150-NT2 ➊ The same protective module mounts on the line or load side of the SMC PLUS. For applications requiring both line and load side protection, two protective modules must be ordered. ➋ Protective modules are standard on 500…1000 A units. Product Selection — Page 43 49 Bulletin 150 Smart Motor Controllers — SMC PLUS Options SMC Easy Ship program descriptions are printed in blue. See page 39. Option Soft Stop ➊➋➌ Pump Control ➊➋ Preset Slow Speed ➊➋ Description Provides a ramp down time of 2…60 seconds for applications which require an extended coast-to-rest. Provides smooth motor acceleration and deceleration, reducing surges caused by the starting and stopping of centrifugal pumps. Starting time is adjustable from 2…30 seconds, and stopping time is adjustable from 2…120 seconds. Provides a preset slow speed for positioning or alignment applications. Preset speeds can be selected at either 7% or 15% of rated motor speed, in the forward direction, 10% or 20% in the reverse direction. The direction of the motor is dip switch selectable. Slow speed current is adjustable from 50…450% of full load current. SMB Smart Motor Braking ➊➋➌ Provides a microcomputer based braking system which applies three-phase braking current to a standard squirrel-cage induction motor. The strength of the braking current is adjustable from 150…400% of full load motor current. Accu-Stop ➊➋➌➎ Provides precise stopping control for positioning or to minimize jogging to stop. A three-phase braking current is applied to the motor (adjustable from 150…400% of full load current) until it reaches a preset slow speed (either 7% or 15% of rated motor-speed). The motor is held at this speed until a stop command is given. Braking torque is then applied until the motor reaches zero speed. Slow speed current is adjustable from 50…450% of full load current. Slow Speed with Braking ➊➋➌➏ Provides forward slow speed for positioning and alignment, and braking control to stop. Price Adder Code Cat. No. Modification a…m A➍ a…m B➍ a…m C➍ a b c d e f g h i j k l m a b c d e f g h i j k l m a b c d e f g h i j k l m ➊ Only one option may be added to the standard unit. ➋ Observe the thermal rating of the AC induction motor. ➌ Not intended to be used as an emergency stop. Refer to the applicable standards for emergency stop requirements. ➍ Add the designated letter to the end of the Cat. No. For example, to add the Pump Control Option: Cat. No 150-24NBD becomes Cat. No. 150-A24NBDB or Cat. No. 152B-WBB-56 becomes Cat. No. 152B-WBBB-56 for combination style. ➎ Accu-stop Control is not available when a bypass contactor is used. ➏ Kickstart is not available with this option. Product Selection — Page 43 50 D➍ E➍ F➍ Bulletin 150 Smart Motor Controllers — SMC PLUS Options, Continued SMC Easy Ship program descriptions are printed in blue. See page 39. Option Push Buttons Selector Switch Pilot Lights Control Circuit Transformer Protective Modules ➌ Overload Relay ➍➎ External Overload Relay Reset ➏ Overload Auxiliary Contact Isolation Contactor ➊ ➋ ➌ ➍ ➎ ➏ ➐ Description Start-Stop Push Button Start-Stop Push Button with H-O-A Selector Switch Soft Stop Push Button ➊ Pump Stop Push Button ➊ Slow Speed Push Button ➊ Brake Push Button ➊ Accu-Stop/Slow Speed Push Button ➊ Emergency Stop Fault Reset Hand-Off-Auto Selector Switch SMC-Off-Bypass Selector Switch Forward-Off-Reverse Selector Switch Transformer Pilot Light (Red Lens — Easy Ship Program) ➋ Push-to-Test Pilot Light ➋ Control Circuit Transformer (fused primary and secondary) Additional 100 VA Control Circuit Transformer (fused primary and 24…54 A, 480V Line Side Protective Module 97…360 A, 480V Line Side Protective Module 24…54 A, 600V Line Side Protective Module 97…360 A, 600V Line Side Protective Module 24…54 A, 480V Load Side Protective Module 97…360 A, 480V Load Side Protective Module 24…54 A, 600V Load Side Protective Module 97…360 A, 600V Load Side Protective Module 24…54 A, 480V Both Line and Load Side Protective Modules 97…360 A, 480V Both Line and Load Side Protective Modules 24…54 A, 600V Both Line and Load Side Protective Modules 97…360 A, 600V Both Line and Load Side Protective Modules Three-pole thermal overload relay for 24…35 A units Three-pole thermal overload relay for 54 A units Three-pole thermal overload relay for 97…135 A units Three-pole thermal overload relay for 180…360 A units Three-pole thermal overload relay for 500 units Three-pole thermal overload relay for 650…850 A units Three-pole thermal overload relay for 1000 A units 24…54 A Overload Relay Reset 97…240 A Overload Relay Reset 360…1000 A Overload Relay Reset N.O. Overload Relay Auxiliary Contact N.C. Overload Relay Auxiliary Contact Isolation Contactor Price Adder Code a...m a...m a...m a...m a...c d...h a...c d...h a...c d...h a...c d...h a...c d...h a...c d...h a...b c d...e f...h i j...l m a...c d...g h...m Cat. No. Modification -1 -1F -1XA -1XB -1XC -1XD -1XE -1E -FR -3 -3B -3R -4_ -5_ -6P -6PX -8L4 -8L6 -8M4 -8M6 -8B4 -8B6 -OL -7 a...m -9 -9A a...d e...f g h i j k...l m ➐ Option push buttons are only available when the corresponding option module is selected. For example, Cat. No. 150-A24JBDA-1XA. Specify pilot light lens color. Options: Amber, Blue, Clear, Green, Red, and White. For example, -4R for a red lens. Line and Load Side Protective Modules are standard on 500…1000 A units. Three-pole thermal overload for Bulletin 150 enclosed controllers only. Overload is standard on Bulletins 152 and 153. Three-pole thermal overload does not include heater elements. External Overload Relay Reset is available with Bulletins 152, 153, and enclosed Bulletin 150 devices with overload option only. To order a non-combination or combination enclosed controller with an isolator contactor, add the letter “B” to the bulletin prefix. See pages 36-37. Bulletin 100 contactors are used through 600 A. Enclosure dimensions are subject to change. Consult factory for dimensions. 51 Bulletin 150 Smart Motor Controllers — SMC PLUS Options, Continued Option Reversing Contactor NEMA Bypass Contactor ➋ NEMA Isolation Contactor ➋ Power Factor Correction Capacitors ➌ Description Reversing Contactor NEMA Bypass for 24…97 A unit NEMA Bypass for 135…180 A unit NEMA Bypass for 240 A unit NEMA Bypass for 360 A unit NEMA Bypass for 500 A unit NEMA Bypass for 650 A unit NEMA Bypass for 24…97 A unit NEMA Bypass for 135…180 A unit NEMA Bypass for 240 A unit NEMA Bypass for 360 A unit NEMA Bypass for 500 A unit NEMA Bypass for 650 A unit 2 kVAR 2.5 kVAR 3 kVAR 4 kVAR 5 kVAR 6 kVAR 7 kVAR 7.5 kVAR 8 kVAR 9 kVAR 10 kVAR 11 kVAR 12.5 kVAR 14 kVAR 15 kVAR 16 kVAR 17.5 kVAR 18 kVAR 20 kVAR 22.5 kVAR 25 kVAR 27.5 kVAR 30 kVAR 32.5 kVAR 35 kVAR 37.5 kVAR 40 kVAR 42.5 kVAR 45 kVAR 47.5 kVAR 50 kVAR Price Adder Code a...d e...f g h i j k...l m a…d e…f g h i j a…d e…f g h i j Cat. No. Modification ➊ -NB -NI -PFCC➍ ➊ To order a non-combination or combination enclosed controller with a reversing contactor, add an “R” to the bulletin prefix. See pages 41…42. Bulletin 104 contactors are used through 500 A @ 480V. Enclosure dimensions are subject to change. Consult factory for dimensions. ➋ 720, 850, 1000 A units currently use a NEMA Contactor. ➌ Power Factor Correction Capacitor to include Power Capacitors with 3-phase Class J Time-Delay Fusing and appropriately sized contactor. ➍ To order Power Factor Correction Capacitors indicate kVAR rating. For example: -PFCC30kVAR. Product Selection — Page 43 Accessories — Page 49 Specifications — Page 56 Approximate Dimensions — Page 59 52 Bulletin 150 Smart Motor Controllers — SMC PLUS Options, Continued Option Power Factor Correction Contactor ➊ SCR Fusing Panel Board Type Ammeter Panel Board Type Voltmeter Elapsed Time Meter Unwired Control Relays ➋ Control Relays Auxiliary Contacts ➌ Disconnect Auxiliary ➍ Circuit Breaker Disconnect Auxiliary ➎ High Interrupting Circuit Breaker Description Power Factor Correction Capacitor Contactor Fast acting current limiting SCR fusing for 24 A unit Fast acting current limiting SCR fusing for 35 A unit Fast acting current limiting SCR fusing for 54 A unit Fast acting current limiting SCR fusing for 97…135 A units Fast acting current limiting SCR fusing for 180 A unit Fast acting current limiting SCR fusing for 240 A unit Fast acting current limiting SCR fusing for 360 A unit Fast acting current limiting SCR fusing for 500 A unit Fast acting current limiting SCR fusing for 650…720 A units Fast acting current limiting SCR fusing for 850 A unit Fast acting current limiting SCR fusing for 1000 A unit Single-phase panel board type ammeter for 24 A units Single-phase panel board type ammeter for 35…97 A units Single-phase panel board type ammeter for 135…240 A units Single-phase panel board type ammeter for 360 A units Single-phase panel board type ammeter for 500…650 A units Single-phase panel board type ammeter for 720…1000 A units Panel board type ammeter with switch for monitoring all three phases Single-phase panel board type voltmeter Panel board type voltmeter with switch for monitoring all three phases. Elapsed time meter Bulletin 700CF 4-pole relay – 2 N.O. and 2 N.C. Bulletin 700CF 4-pole relay – 3 N.O. and 1 N.C. Bulletin 700CF 4-pole relay – 4 N.O. On-Delay Off-Delay N.O. auxiliary contacts for 24…240 A units N.O. auxiliary contacts for 360…1000 A units N.C. auxiliary contacts for 24…240 A units N.C. auxiliary contacts for 360…1000 A units 1 N.O. ... 1 N.C. auxiliary contacts for 24...240 A units 1 N.O. ... 1 N.C. auxiliary contacts for 360...1000 A units N.O. disconnect auxiliary mounted on operating mechanism N.C. disconnect auxiliary mounted on operating mechanism Internal N.O. circuit breaker auxiliary Internal N.C. circuit breaker auxiliary High Interrupting Circuit Breaker for 24...54 A units High Interrupting Circuit Breaker for 97...180 A units High Interrupting Circuit Breaker for 240 A units High Interrupting Circuit Breaker for 360 A units High Interrupting Circuit Breaker for 500 A units High Interrupting Circuit Breaker for 650...720 A units High Interrupting Circuit Breaker for 850...1000 A units Price Adder Code a...d e...f g h i j a b c d...e f g h i j...k l m a b...d e...g h i...j k...m a...m a...m a...m a...m a...h a...g h...m a...g h...m a...g h...m a...m a...m a...c d...f g h i j...k l...m Cat. No. Modification -PFCCC -SCR -85AA -86AA -85AV -86AV -85T -89F22 -89F31 -89F40 -89FOD -89FOFD -90 -91 -901 -98 -99 -98X -99X -HICB ➊ Only the contactor will be provided. For motor horsepower above 500 consult factory for sizing and pricing. ➋ Instantaneous auxiliary contacts on Bulletin 700F relays are non-convertible. ➌ Available only with enclosed Bulletin 150, 152 and 153 devices with an isolation contactor or bypass contactor. Maximum of four (4) auxiliary contacts. ➍ Available only with Bulletin 152 and 153 devices. Maximum of two (2) disconnect auxiliaries. ➎ Available only with Bulletin 153 devices. Maximum of two (2) disconnect auxiliaries. Product Selection — Page 43 53 Bulletin 150 Smart Motor Controllers — SMC PLUS Options, Continued Option Shunt Trip ➊ Additional Load Circuit Breakers ➋ Line Voltage Monitor Thermistor Protection Relay Smart Motor Manager IQ1000 Protective Relay Multilin 269 Plus Transducer Output Ground Fault Protection Description Circuit Breaker Shunt Trip for 24…54 A units Circuit Breaker Shunt Trip for 97…135 A units Circuit Breaker Shunt Trip for 180…240 A units Circuit Breaker Shunt Trip for 360…500 A units Circuit Breaker Shunt Trip for 650…850 A units Circuit Breaker Shunt Trip for 1000 A units Additional load circuit breakers to be installed in panel. Customer is to stipulate size and quantity. Bulletin 813S Line Voltage Monitor Bulletin 817 Thermistor Protection Relay Bulletin 825 Smart Motor Manager and Bulletin 825 Converter Module Cutler-Hammer IQ1000 Protective Relay GE Multilin 269 Plus Protective Relay 4…20 mA output signal proportional to 1…100% motor FLC Bulletin 1409 Arcing Ground Fault Relay and Sensor for applications up to 400 HP Motor Winding Heater ➋ Bulletin 1410 Motor Winding Heater for applications up to 600 HP Lightning Arrestor Strip Heater Lightning Surge Protection Cabinet Strip Heater with Thermostat Service Entrance Label Service Entrance Label Price Adder Code Cat. No. Modification a...c d...e f...g h...i j...l m -754 a...m -ALCB a...m a...m a...m a...m a...m a...m -813S -817 -SMM -IQ1000 -269PLUS -TO a...i -GFP a...e f…g h…i j…k a...m a...m a...j k…l a...m -MWH -LA -SH -SEL U.L. Label U.L. Label Unwired Terminal Blocks Panel Mounted Unwired Terminal Blocks 6 or 12 position a...m Components mounted on enclosure mounting plate only Customer is to stipulate panel dimensions a...m a...m -UL -TB6 -TB12 -PM -SPD Panel Mount ➌ Specified Panel Dimensions ➌ Enclosure Color (Custom Paint) ➌ Enclosure Shock Mounts ➌ Customer is to stipulate paint color for enclosure a...m -EC Ship Board – MIL-S-901D -SM Enclosure Type NEMA 3R ➍ Enclosure Type NEMA 3R Non-Combination Enclosure Type NEMA 3R ➍ Enclosure Type NEMA 3R Combination a...m a…c d…e f…h i…m a…c d…e f…h i…m ➊ ➋ ➌ ➍ ➎ ➎ Available only with Bulletin 153 devices. Requires an isolation contactor on the output of the SMC. Pricing to be determined upon request. To order a non-combination or combination enclosed controller with a NEMA 3R enclosure, add an “H” to the enclosure type prefix. Example: Cat. No. 152H-B240HBD-54. See pages 41…42. Enclosure dimensions are subject to change. Consult factory for dimensions. Enclosure price adder is to be added to NEMA 12 non-combination or combination price. ➎ Consult factory for pricing. Product Selection — Page 43 Accessories — Page 49 Specifications — Page 56 Approximate Dimensions — Page 59 54 Bulletin 150 Smart Motor Controllers — SMC PLUS Options, Continued Option Description Enclosure Type NEMA 4X Stainless Steel ➊ Enclosure Type NEMA 4X Stainless Steel Non-Combination Enclosure Type NEMA 4X Stainless Steel ➊ Enclosure Type NEMA 4X Stainless Steel Combination Air Conditioning ➋ Wiring Diagrams Print Approval ➌ AC Unit mounted on enclosure AutoCad Drawing of panel wiring Customer Requested Print Approval Drawings Price Adder Code a…d e…f g…h i…m a…c d…e f…h i…m a...m a...m a...m Cat. No. Modification ➍ ➍ -AC -WD -PA ➊ To order a non-combination or combination enclosed controller with a NEMA 4X stainless steel enclosure, add an “S” to the enclosure type prefix. Example: Cat. No 152H-B240SBD-54. See pages 41…42. Enclosure dimensions are subject to change. Consult factory for dimensions. Enclosure price adder is to be added to the NEMA 12 non-combination or combination price. ➋ Pricing to be determined upon request. ➌ Order to be released to manufacturing upon return of signed approval drawing. ➍ Consult factory for pricing. Product Selection — Page 43 Accessories — Page 49 Specifications — Page 56 Approximate Dimensions — Page 59 55