Speed Sel 1 = Open Speed Sel 2 = Open = Speed Source is 0 to 10 Volts I/O Terminal Block 27 Speed Sel 1 = Closed Speed Sel 2 = Open = Speed Source is Preset 1 Speed Sel 1 = Open = Speed Source is Preset 2 Speed Sel 2 = Closed 28 29 Speed Sel 1 With Vector Control 30 Speed Sel 2 31 32 26 24V Common 25 Digital In Common 24 +24V 19 Analog In 2 (- Volts) 20 Analog In 2 (+ Volts) 0 to 10 Volts Parameters that need to be reprogrammed U V W File - Inputs & Outputs Group - Digital Inputs Terminal 361 (Digital In1 Sel) = N/A 362 (Digital In2 Sel) = N/A 363 (Digital In3 Sel) = N/A 364 (Digital In4 Sel) = 15 365 (Digital In5 Sel) = 16 366 (Digital In6 Sel) = N/A Motor Parameters that need to be reprogrammed 6 5 4 Speed Command Source 0 0 0 Speed Ref A Sel, See Par #090 Default is Analog In 2, 0-10 Volts 0 0 1 Speed Ref B Sel, See Par #093 Default is Preset 1, Par #101 0 1 0 Preset Speed 2, Par #102 0 1 1 Preset Speed 3, Par #103 1 0 0 Preset Speed 4, Par #104 1 0 1 Preset Speed 5, Par #105 1 1 0 Preset Speed 6, Par #106 1 1 1 Preset Speed 7, Par #107 File - Speed Command Group - Speed References 90 (Speed Ref A Sel) = 2 (Analog In 2) 93 (Speed Ref B Sel) = 11 (Preset Spd1) File - Speed Command Group - Discrete Speeds 101 (Preset Speed 1) = 10 Hz 102 (Preset Speed 2) = 30 Hz