TL04UO - Communications & Power Industries

Ku-Band
400 W SuperLinear® Outdoor TWTA
Plays in the Rain
Provides 200 watts of linear power at the flange in a rugged
and compact weatherproof package, digital ready, for
wideband, single- and multicarrier satellite service in the
13.75 to 14.50 GHz frequency band (extended and narrower
bands also available). Ideal for transportable and fixed earth
station applications.
Cost Effective and Highly Efficient
As part of the SuperLinear TWTA product line, this is the
most efficient and compact amplifer in its class. Both the
tube and HPA are optimized for efficient operation at linear
power output levels.
Reliable
Designed and built to survive in extremely adverse
environmental conditions and features increased cooling
margin for longer life. CAN-Bus architecture improves noise
immunity and reliability.
Simple to Operate
User-friendly microprocessor-controlled logic with
integrated Ethernet computer interface. Digital metering,
pin diode attenuation and optional integrated linearizer for
improved intermodulation performance. SNMP serial
interface included.
Model TL04UO
400 watt Ku-band SuperLinear TWTA
for satellite uplink applications
OPTIONS
•Remote Control Panel
•L-Band Block Upconverter (refer to
TD-191 or contact CPI for specifications)
•Integral Linearizer
•Extended Frequency (12.75 - 14.50 GHz)
•External Receive Band Reject Filter
(Increases loss by by a minimum of 60 dB
up to 12.7 GHz)
•Redundant Subsystems
•Integrated 1:1 Switch Control and Drive
Global Applications
Meets International Safety Standard EN-60215,
Electromagnetic Compatibility 2004/108/EC and Harmonic
Standard EN-61000-3-2 to satisfy worldwide requirements.
Worldwide Support
Backed by over 35 years of satellite communications
experience, and CPI’sworldwide 24-hour customer
support network that includes more than 20 regional
factory service centers.
811 Hansen Way, PO Box 51625
Palo Alto, CA 94303 USA
tel:
+1 (650) 846-3803
fax:
+1 (650) 424-1744
e-mail:[email protected]
website:www.cpii.com/satcom
Ku-Band
Specifications 400 W Ku-band SupearLinear® Outdoor TWTA
Specification
Input Frequency
Output Frequency
Model TL04UO
0.95 to 1.70 GHz with BUC (0.95 to 1.95 GHz with wideband option).
14.00 to 14.50 GHz or 13.75 to 14.50 GHz (12.75 to 14.50 GHz optional)
Output Power (min.)
TWT
CW Power at Flange
Max. CW Flange Power
400 watts (56.0 dBm) peak
200 W (53.0 dBm) min.
220 W (53.4 dBm)
Bandwidth
Gain
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
500 or 750 MHz (1075 MHz optional)
67 dB min. at rated power, 70 dB typ. at small signal
±0.25 dB/24 hours max. (at constant drive and temperature)
±0.02 dB/MHz max. (±0.04 dB/MHz max. with BUC option)
1.0 dB pk-pk max. across any 80 MHz band; 3.0 dB pk-pk max. across any 500 MHz
RF Level Adjust Range
Input VSWR
30 dB typ.
1.3:1 max. (1.5:1 max. with BUC option)
Output VSWR
2.0:1 max.
Load VSWR
2.0:1 max. continuous operation; any value for operation without damage
Phase Noise
-10 dB below IESS-308/309; -42 dBc AC fundamental; -50 dBc sum of spurs
Spurious
AM/PM Conversion
Harmonic Output
Noise Density (at max. gain)
Spectral Regrowth
Intermodulation
Group Delay
Prime Power
Power Consumption
-60 dBc max. at rated output
2.0˚/dB max. up to 46 dBm output power (up to 53 dBm with optional linearizer)
-65 dBc at rated power (-60 dBc at rated power with optional linearizer)
<-150 dBW/4 kHz, 10.00 to 12.75 GHz; <-70 dBW/4 kHz, passband to 18 GHz (<-65 dBW/4 kHz with optional linearizer)
-30 dBc max. @ 1.0 S.R. at 49 dBm output power (at 53 dBm output power with optional linearizer)
-25 dBc max. with two equal carriers at total output power of 80 W (at 160 W with optional linearizer);
-25 dBc max. with respect to the sum of both carriers at total output power of 100 W (at 200 W with optional linearizer)
0.01 ns/MHz linear max, 0.001 ns/MHz2 parabolic max, 1.0 ns pk-pk ripple max. in any 40 MHz band
100 to 240 VAC +/-10% single phase, 47-63 Hz
1000 VA max; 750 VA typ. at 160 W output power
Power Factor
0.95 min.
Amplitude and Phase Linearity
Ambient Temperature
Exceeds MIL-STD-188-164B
Ambient Temperature -40°C to +60°C operating, plus solar loading; -54°C to +71°C non-operating
Relative Humidity
Altitude
100% condensing
10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 50,000 ft, non-operating
Shock
20 g peak, 11 ms, 1/2 sine
Vibration
2.1 grms, 5 to 500 Hz
Acoustic Noise
65 dBA at 3 feet from amplifier
Cooling
Forced air with integral blower
M&C Port
Ethernet interface
Input Connection
RF Output Connection
Type N female
WR75 waveguide flange, grooved with UNC 2B 6-32 threaded holes
RF Output Monitor
Dimensions
Type N Female
10.5 x 8.5 x 17.0 in. max. (267 x 216 x 432 mm)
Weight
32 lbs (14.6 kg) typ.
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 322, ISSUE 8 dated JUN 2015