250W SuperLinear ® Outdoor BUC for Satellite Communications Ku- Band The TL02UO Ku-Band 250 Watt Peak Power TWT BUC — high efficiency and linearity in an environmentally sealed compact package designed for outdoor operation Easy to Maintain Provides up to 100 watts of linear power at the flange in a rugged and compact weatherproof package, digital ready, for wideband, single- and multi-carrier satellite service in the 14.0-14.5 GHz or 13.75-14.50 GHz frequency bands. An L-Band Block Upconverter is included as standard. Ideal for transportable and fixed earth station applications. Modular design and built-in fault diagnostic capability via remote monitor and control. Cost Effective and Efficient Worldwide Support Mounting at the antenna improves performance through minimized cable losses and saves cost in system design. Employs a high efficiency, dualdepressed collector helix traveling wave tube, reducing operating costs. Backed by over two decades of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than twenty regional factory service centers. Global Applications Meets International Safety Standard EN-60215, Electromagnetic Compatibility 2004/108/EC and Harmonic Standard EN-61000-3-2 to satisfy worldwide requirements. Reliable Designed and built to survive in extremely adverse environmental conditions and features increased cooling margin for longer life. Simple to Operate User-friendly microprocessor-controlled logic with integrated Ethernet computer interface. Digital metering, pin diode attenuation and optional integrated linearizer for improved intermodulation performance. 811 Hansen Way P.O. Box 51625, Palo Alto, CA 94303 tel: +1 (650) 846-3803 fax: +1 (650) 424-1744 e-mail: [email protected] www.cpii.com/satcom 250/100W SuperLinear® Outdoor BUC Plays in the Rain Ku -B a n d SPECIFICATIONS, TL02UO BUC Electrical OPTIONS: • Remote Control Panel Frequency 950 MHz to 1450 MHz (input) 14.0 to 14.5 GHz (output) Output Power TWT Peak Power Flange Peak Power* Linear power at flange CW output power at flange 250 W min. (53.98 dBm) 220 W min. (53.42 dBm) 40 W min. (46.0 dBm) (100 W min. with linearizer) 100 W (max.) Electrical (continued) Intermodulation-25 dBc max. @ 40 W output power (at 100 W output power with optional linearizer), with respect to the sum of two carriers. Primary Power 100-240 VAC ±10% single phase, 47-63 Hz Power Consumption 550 VA max. 500 VA typ. at 100 W output power 300 VA typ. at 1 W output power •Extended Frequency: 13.75-14.50 GHz; 12.7513.25 GHz) *Note: This amplifier provides a maximum of 100 W CW power at the flange. The Flange Peak Power specification (220 W) is provided so that the user Power Factor can more easily calculate the desired backoff level from peak. • Redundant and Power Combined Subsystems Bandwidth 500 MHz Gain 6 0 dB min. at rated power output; 64 dB typ. at small signal • External Receive Band Reject Filter (Increases loss by a minimum 60 dB up to 12.7 GHz) •Integrated 1:1 switch control and drive Gain Stability±0.25 dB/24hr max. (at constant drive and temp.) Small Signal Gain Slope±0.04 dB/MHz max. Small Signal Gain Variation1.0 dB pk-pk across any 80 MHz band; 3.0 dB pk-pk across the 500 MHz band RF Level Adjust Range •Integral Linearizer •Remove BUC - contact CPI for details on specifications 30 dB typ. Input VSWR 1.3:1 max. Output VSWR 2.2:1 max. Load VSWR2.0:1 max. continuous operation; any value for operation without damage MUXed External 10 MHz -115 dBc/Hz at 10 Hz Reference Phase Noise-140 dBc/Hz at 100 Hz Required (L-Band Input -145 dBc/Hz at 1 kHz 950 - 1450 MHz) -150 dBc/Hz at ≥10 kHz (Level -3 to +7 dBm) Single Sideband Phase Noise-63 dBc at 100 Hz offset -73 dBc at 1 kHz offset -83 dBc at 10 kHz offset -93 dBc at 100 kHz offset -103 dBc at 1 MHz offset -113 dBc at ≥10 MHz offset Spurious -60 dBc max. at 100 W output AM/PM Conversion2.0°/dB max. for a single carrier up to 100 W Harmonic Output-60 dBc max. at 100 W output Noise Power Density (at maximum gain) <-150 dBW/4 kHz, below 12.7 GHz <-66 dBW/4 kHz, passband to 18.0 GHz Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 214B, ISSUE 5 OCT 14 PDF 0.95 min. Environmental (Operating) Ambient Temperature-40°C to +60°C operating, including solar loading; -40°C to +71°C non-operating Relative Humidity 100% condensing Altitude10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 50,000 ft., non-operating Shock 20 g pk, 11 mS, 1/2 sine Vibration 3 grms Acoustic Noise 65 dBA @ 3 ft. from amplifier Mechanical CoolingForced air with integral blower L-Band Input Connection Type N female RF Output Connection WR-75 waveguide flange, grooved with UNC 2B 6-32 threaded holes RF Output Monitor Type N female, 44 dB nom. Dimensions (W x H x D) 8.5 x 8.5 x 15 in. max. (216 x 216 x 381 mm) Weight 25 lbs (11.4 kg) typ