K4S - Communications & Power Industries

S-Band Gen IV Klystron High Power Amplifier
for Satellite,Troposcatter and Terrestrial Gapfiller Applications
S- Band
The Gen IV High
Power Amplifier
(K4S74 and
K4S71 Series)
Unmatched Efficiency
S-Band Gen IV —
provides up to 1.2,
2.5 or 3.0 kW of power in
a dual drawer package
Uses less power and produces less heat than any
other K-HPA. Features Power Saver and Power
Tracker, optimizing K-HPA efficiency to meet your
operating condition.
Scopescreen provides a graphical log display. The
Ethernet Option provides higher speed connections,
can update and coordinate all clock settings, and
enables a snapshot feature where user can create
a file containing all settings, alarms and faults at a
single point in time.
Integrated Protection Switching
Unmatched Size
Greater efficiency and exceptional thermal margins
have enabled CPI to design the smallest KPA on
the market --- without the threat of overheating or a
shorter klystron life.
Easy Maintenance
All areas of the amplifier are easily accessible and
there are no large harnesses to get in the way.
Separate RF and Power Supply drawers slide out
from a standard rack.
Greater Reliability
Low temperatures are the key to longer lifetimes
for klystrons and electronic parts. The CPI power
supply design and high efficiency, multi-stage
depressed collector klystron make these lower
temperatures possible.
Useful Displays
Large, high quality, color, graphical display has a
wide viewing angle and a sharp appearance. All
important functions are clearly displayed, and an
event log is included.
Acoustically Quiet
The quietest K-HPA in the industry.
Worldwide Support
Backed by over three decades of satellite
communications experience, and CPI's worldwide
24-hour customer support network that includes
sixteen regional factory service centers.
811 Hansen Way
P.O. Box 51625, Palo Alto, CA 94303
tel: +1 (650) 846-3803
fax: +1 (650) 424-1744
e-mail: [email protected]
www.cpii.com/satcom
Gen IV Klystron High Power Amplifier
Redundant switch controller eliminates the cost of
external controllers. System status is shown on the
display and switch controls are implemented
locally on the front panel touch-pad, or remotely
via the digital serial interface.
S-Band
New Features and Options
S -B a n d
SPECIFICATIONS, S-Band Gen IV
Electrical (continued)
Electrical
Frequency Range
1.6 - 2.0 GHz, 1.7 - 1.9 GHz, 1.7 - 2.0 GHz,
2.0 - 2.2 GHz, 2.15 - 2.65 or 2.6 - 2.7 GHz
(others available)
Klystron Power Output
2.5 kW min. (64.0 dBm),
3.0 kW min. at 2.6 GHz (64.8 dBm)
1.2 kW min. (60.8 dBm) for 25 MHz BW
Amplifier Output
at flange1
2.0 kW min. (63.0 dBm),
2.66 kW min. at 2.6 GHz (64.3 dBm)
900 W (59.5 dBm) for 30 MHz BW
Bandwidth
8 MHz (-1 dB);
25 MHz for 1.2 kW KPA
Power Adjustability
0 to -20 dB of output with ±0.1 dB
typical resolution
Gain at Rated Power
70 dB min.;
60 dB for 1.2 kW KPA
• Ethernet Interface
Gain Stability vs. Time
±0.25 dB/24 hr. max. at constant drive
and temperature
• Power Combined Option
Gain Stability vs. Temp.
1 dB max. from 20° to 40°C; ±2.5 dB max
from 0° to 50°C (at constant drive)
OPTIONS:
• Motorized Channel
Selector: (<10 seconds)
• Remote Control Panel
• Linearizer
Gain Slope
(at rated power)
0.02 dB/MHz max. over (Fo±2.5 MHz)
Gain Variation
(at rated power)
0.5 dB pk-pk max. over (Fo±2.5 MHz)
Input VSWR (200 MHz Tunable) 1.25:1 max.; 1.30:1 max (>200 MHz Tunable)
Output VSWR (200 MHz Tunable) 1.35:1 max.; 1.40:1 max (>200 MHz Tunable)
Klystron Magnet Susceptibility:
Install RF Drawer at least 12 inches
from ferromagnetic structures (i.e.
power transformers, cold rolled
steel racks or structural beams).
Failure to comply with this
requirement may result in
degraded RF performance and/or
product failures.
Load VSWR
2.0:1 max. for full spec. compliance;
any value for operation without damage
AM/PM Conversion
(at rated power)
3°/dB maximum
Harmonic Output1
Power Consumption5
8.0 kW max. Typical values for the
following RF output backoffs with
respect to rated (power saver off):
7.2 kW @ 0 dB (rated)
5.5 kW @ -4 dB
4.7 kW @ -7 dB
4.2 kW @ -10 dB
4.0 kW @ -13 dB
Power Factor
0.95 min.
Inrush Current, peak
180% of normal line current peak
max. (first half cycle only)
Mechanical
RF Input Connection
Type N female
RF Output Connection
CPR-430 Grooved flange
below 2.10 GHz
(CPR-340G flange at 2.6-2.7 GHz
above 2.10 GHz)
RF Power Monitors
Type N female
Dimension (W x H x D without fans and handles)
RF Drawer (Above 2.1 GHz)
19 x 21 x 32 in.1
(483 x 534 x 813 mm)1
(Below 2.1 GHz)
19 x 24.5 x 42 in.1
(483 x 623 x 2070 mm)1
PS Drawer
19 x 8.75 x 24 in.
(483 x 223 x 610 mm)
Weight
RF Drawer
280 lbs w/klystron (127 kg)
PS Drawer
100 lbs (45.4 kg)
Cooling
Forced air with integral blower and
fans; separate klystron collector
cooling path
-80 dBc
Air Flow Rate, Klystron
Noise and Spurious
(at rated gain)
-145 dBW/4 kHz, receive band typ.
-60 dBW/4 kHz, in passband typ.
-110 dBW/MHz, outside passband typ.
250 cfm min., at sea level
(175 cfm at 10,000 feet)
External Ducts Backpressure
0.5 inch water gauge
total, maximum
Phase Noise3
Exceeds requirements of IESS-308/309
at -10 dB backoff.
Klystron Heat Loss
5300 W max.
-29 dBc with two equal carriers at total output
7 dB below rated single-carrier output
Heat Loss in Room
(cabinet less Klystron)
2000 W max.
Intermodulation4
Acoustic Noise
Group Delay4
3.0 ns/MHz linear max.
2.0 ns/MHz2 parabolic max.
4.0 ns pk-pk ripple max.
63 dBA nominal, measured
3 ft. from front of equipment
Primary Power3
All ratings are ± 10%,
47-63 Hz 3-phase with
neutral and ground:
208 VAC
380 to 415 VAC
200 VAC (without neutral)
Environmental
Ambient Temperature
-10° to +50° operating;
-40° to +80° non-operating
Relative Humidity
95%, non-condensing
Altitude
operating:
non-operating:
1External Harmonic Filter may be removed as an option. Add 0.25 dB to amplifier output for units ordered
without this option, and increase Harmonic Output to -30 dBc. The external harmonic filter extends 12 to
18" behind the back panel of the RF drawer.
Shock and Vibration
2Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause an increase in residual
RF noise (AM, FM and PM). Phase noise increase is typically 2.5 dB / % imbalance.
5Lower power consumption can be achieved if power saver (included as standard)
is employed when operating below rated output power. Power consumption for 1.2 kW
klystron PA is 5.9 kW typ. at rated power, 3.5 kW typ. at 13 dB backoff.
3AC current harmonic content: less than 20%, primarily fifth and seventh harmonics. Harmonics must be
considered when choosing UPS sources.
4Typical values for 1.2 kW 25 MHz version. Maximum values TBD.
Certificate Number: 30515
Please check CPI’s web site to ensure most current data sheet.
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 123, ISSUE 9
09/11
PDF
10,000 ft. (3000 m) with standard
adiabatic temp derating of
2°C/1000 ft. or 6.5°C/km
40,000 ft. (12,000 m)
As normally encountered
in satellite earth stations