Indico 100® G E N E R AT O R P E R F O R M A N C E M AT R I X GENERATOR PERFORMANCE MATRIX Product Name Application Generator Type kV (Radiographic) kV (Fluoroscopic) mA Range RAD mA Range FLUORO1 Rotor Supply Line Nominal/Phase Line Voltage Range High Voltage Ripple (typ.) Number of X-Ray Tubes Timer Rang, Programmable Anatomical Programs6 mAs Range Non AEC3* Number of Image Receptors Technique Selection Exposure Hand Switch Documentation5 GenWare® Service Software Indico 100® SP (80 kW) RF, Multi Purpose & Angiographic Special Procedures. High Frequency Output 200 kHz + 40 – 150 kV 40 – 125 kV 10 – 1000 mA 0.5 – 10 mA continuous Dual Speed – Standard 3 Ø 400 or 480 VAC ± 10% <1 kV @ 100 kV 1 Tube Capability * 20,000 techniques capacity plus 0.1 – 1000 mAs 6 1. kV with AEC option 2. kV/mAs 3. kV/mA/Time Standard Manual or CD Yes Indico 100® SP (100 kW) RF, Multi Purpose & Angiographic Special Procedures. High Frequency Output 200 kHz + 40 – 150 kV 40 – 125 kV 10 – 1000 mA 0.5 – 10 mA continuous Dual Speed – Standard 3 Ø 400 or 480 VAC ± 10% <1 kV @ 100 kV 1 Tube Capability * 20,000 techniques capacity plus 0.1 – 1000 mAs 6 1. kV with AEC option 2. kV/mAs 3. kV/mA/Time Standard Manual or CD Yes Yes Yes Ionization, PMT, or Solid State PMT, Photo Diode, Video or Proportional DC Up to 20 mA Up to 40 mA Up to 80 mA Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Ionization, PMT, or Solid State PMT, Photo Diode, Video or Proportional DC Up to 20 mA Up to 40 mA Up to 80 mA Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes OPTIONS Touch Screen Console Touch Screen Console Wall Mount AEC Interface ABS Interface High Level Continuous Fluoroscopy Pulsed Fluoroscopy High Level Pulsed Fluoroscopy4 kV/mAs Stepping DR/CR/RF Interfaces 2 * CINE2 * CINE2 * (IS0 Watt Mode) Dose Area Product (DAP) Interface Air Kerma Readout Second Tube Capability Wheels5 Custom Interfaces* Active Dose Reduction (ADR) 3 Dose and Transfer Curves S.I.D. Compensation* Tri-Focus Operation * Second Filament Drive Cabinet Wiring Cover* Auxiliary Collimator Power* * Consult Factory for details. 1. Maximum Fluoroscopic kV is 125 kV – programmable to 110 kV for European requirements. 2. Compatible with Digital Imaging System – Consult Factory. 3. The mAs limit may be de-rated by software. 4. Consult Factory for higher mA values. 5. To be identified on order. 6. Touchscreen specification only. ® 0366 NRTL/C L397383 XRAY204 01/08 Wheels (Optional) Indico 100® RF Console Wall Mount (Optional) All dimensions are in mm [inches] CPI Touch Screen Console (Optional) Auxiliary Cabinet (Optional) Desktop Base (Optional) Communications & Power Industries Canada Inc. communications & medical products division 45 River Drive / Georgetown, Ontario / Canada L7G 2J4 Hot Line Telephone: 1-888-CPI-XRAY TEL: 905-877-0161 / FAX: 905-877-5327 E-MAIL: [email protected] WEB: www.cpii.com/cmp