TRANSFORMER CONTROL DRAWING PREMIER P/N: PNK

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
FIGURE 1: SCHEMATIC DIAGRAM
3
SPEC LIMITS
MIN.
TYP.
MAX.
UNITS
PRIMARY INDUCTANCE (5-6).
At 100KHz and 1.0 Vrms.
1.55
H
LEAKAGE INDUCTANCE (5-6).
At 100KHz and 1.0 Vrms.
-------
--------
60
H
NC
RESONANT FREQUENCY (5-6).
Other windings open.
500
--------
-------
KHz
C. SHIELD
PARAMETER
BIAS
TURNS
5-6 :
5-6 :
3-4 :
1.68
1.80
4
5
RATIO:
FL1-FL2.
3-4.
FL1-FL2.
HI-POT: 60 Hz for 1 sec.
PRIMARY to SECONDARY.
-------- 8.44 : 1
-------- 7.94 : 1
-------- 1.06 : 1
----------------------
+3%
+3%
+3%
3000
--------
VRMS
--------
FL1
SECONDARY
FL2
PRIMARY
6
FIGURE 2: PHYSICAL DIMENSIONS IN INCHES, (mm)
10
6
1
PIN#1 I.D.
ON BOBBIN
5
13.5
(.532)
Max.
P
M
CORE
TAPED
13.6
(.535)
Max.
PNK-10035
YYW W
1
5
2.5
(.098)
25.0
(1.0)
7.7
(.303)
Max.
FL1
3.5
(0.14)
Typ.
5
0.6
(0.024)
FL2
6
10.5
(.413)
NOTES:
1) Design to comply with the requirements of UL/CSA/
IEC60950-1.
2) Design to comply with the requirements of UL/CSA/IEC
Class B insulation system.
3) All materials per Premier Magnetics UL file #E177139.
4) All units comply with the requirements of the EU RoHS
Directive.
REV.
DESCRIPTION OF CHANGES
BY
08/12/13
Original release.
KC
RoHS
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN mm.
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ 0.25
+ 5O
.XX + 0.15
DRAW ING NOT TO SCALE.
TRANSFORMER CONTROL DRAWING
PREMIER P/N: PNK-10035
REVISION: 08/12/13
ENGR: PETER PHAM
REF: LNK604DG
QA: Kevin Clark
SHEET: 1 OF 3