POL-HX021 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
PARAMETER
MIN.
PRIMARY INDUCTANCE
100 KHZ @ 0.40V.
1-2
FIGURE 1: SCHEMATIC DIAGRAM
SPEC LIMITS
TYP.
MAX.
655.5
690
LEAKAGE INDUCTANCE 1-2
100 KHZ @ 0.40 V, Short others.
--------
PRIMARY RESONANT FREQUENCY
1.8
TURN
1-3
1-3
2-3
----------------------
SHIELD
UNITS
724.5
H
--------
13
H
--------
-------
MHz
----------------------
+ 4%
+ 4%
+ 4%
1
PRIMARY 2/2
3
RATIO'S:
: 4-5
: 9-10
: 4-5
HIPOT: 60 Hz for 1 sec.
PRIMARY AND BIAS TO SEC.
3000
7:1
8:1
3.62: 1
--------
--------
PRIMARY 1/2
2
9, 10
SECONDARY
4
BIAS
Vrms
7, 8
5
FIGURE 2: PHYSICAL DIMENSIONS mm.
WHITE DOT
PIN#1 I.D.
10
9
8
7
6
1
2
3
4
5
28.0
MAX
P
M
3.0
Min.,
POL-HX021
YYWW
28.1
MAX
20.1
MAX
0.7
Sq.
5.08
20.32
NOTES:
1) Design to comply with the requirements of UL/CSA/
IEC 60950-1.
2) Design to comply with the requirements of UL/CSA/
IEC Class B insulation system.
3) All materials per Premier Magnetics UL file #E177139.
4) All units comply with the requirements of the EU RoHS
Directive.
REV.
DESCRIPTION OF CHANGES
BY
05/07/13
Original Release.
KC
RoHS
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN mm.
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ 0.3
+ 5O
.XX + 0.20
DRAW ING NOT TO SCALE.
TRANSFOMER CONTROL DRAWING
PREMIER P/N: POL-HX021
REVISION: 05/07/13
ENG: Peter Pham
REF: TOP257EN
QA: Kevin Clark
SHEET: 1 OF 1