SB510UL Product profile Surface Mount High Current Density Schottky General description Rectifiers 5.0 Amp 100V Features Low forward voltage drop High current capability High reliability High surge current capability Epitaxial construction Mechanical data Case: DO-201AD, Case: Molded plastic Epoxy: UL 94V-0 rate flame retardant Lead: Lead solderable per MIL-STD-202, method 208 guaranteed Mounting position: Any Weight: 1.10 grams(Approximately) Maximum Ratings (Tc=25°C unless otherwise noted) Parameter Symbol SB510UL Unit Maximum repetitive peak reverse voltage VRRM 100 V RMS Voltage (Max.) VRMS 70 V Working peak reverse voltage VRWM 100 V Maximum average forward rectified current IF(AV) 5.0 A IFSM 210 A TJ -55 to +150 °C TSTG -55 to +150 °C Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) Operating junction temperature range Storage temperature range Publication Order Number: SB510UL ©Bruckewell Technology Corporation Rev. A -2014 SB510UL THERMAL CHARACTERISTICS Parameter Symbol Value Unit Typical thermal resistance RθJA 28 °C/W Notes: (1) Pulse test: 300 μs pulse width, 1 % duty cycle (2) Pulse test: Pulse width ≤ 40 ms Electrical characteristics (Tc=25°C unless otherwise noted) OFF CHARACTERISTICS Parameter Symbol Value Unit Typical Max at IF=1A, Tj=25°C 0.40 0.43 at IF=2A, Tj=25°C 0.43 0.46 at IF=5A, Tj=25°C 0.48 0.53 0.61 0.66 at IF=1A, Tj=125°C 0.28 0.31 at IF=2A, Tj=125°C 0.32 0.35 at IF=5A, Tj=125°C 0.46 0.50 at IF=10A, Tj=125°C 0.57 0.62 Instantaneous forward voltage at IF=10A, Tj=25°C VF V Maximum reverse current Tj=25°C at working peak reverse voltage Tj=125°C IR 20 u'A 5 m'A DEVICE MARK SB510UL Publication Order Number: SB510UL ©Bruckewell Technology Corporation Rev. A -2014 SB510UL Characteristic Curves 8 Average Power Loss (W) 7 6 5 4 3 2 1 0 0 2 4 6 8 10 Average Forward Current (A) 100.0 100 Instantaneous Reverse Current (mA) Instantaneous Forward Current (A) Tj=150°°C Tj=150°°C 10.0 Tj=125°°C 1.0 Tj=25°°C 0.1 0.000 0.200 0.400 0.600 0.800 10 0.1 Tj=25°°C 0.01 0.001 0.0001 1.000 20 Instantaneous Forward Voltage (V) 30 40 50 60 70 80 90 100 Percent of Rated Peak Reverse Voltage (%) Figure 4. Typical Reverse Characteristics Figure 3. Typical Instantaneous Forward Characteristics Per Leg 100 Transient Thermal Impedance (°C/W) 10,000 Junction Capacitance (pF) Tj=125°°C 1 1,000 100 10 0.1 1 10 Reverse Voltage (V) Figure 5. Typical Junction Capacitance Publication Order Number: SB510UL 100 10 1 0.01 0.1 1 10 100 t, Pulse Duration, (sec.) Figure 6. Typical Transient Thermal Impedance ©Bruckewell Technology Corporation Rev. A -2014 SB510UL Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Bruckewell Technology Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Bruckewell”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Bruckewell makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Bruckewell disclaims (i) Any and all liability arising out of the application or use of any product. (ii) Any and all liability, including without limitation special, consequential or incidental damages. (iii) Any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Bruckewell’s knowledge of typical requirements that are often placed on Bruckewell products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. Product specifications do not expand or otherwise modify Bruckewell’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Publication Order Number: SB510UL ©Bruckewell Technology Corporation Rev. A -2014