diesel power module mtu 16v4000 ds1955

DIESEL POWER MODULE
MTU 16V4000 DS1955
Voltages:
2160 kWe / 2700 kVA / 60 Hz / Standby - 480V
1955 kWe / 2443 kVA / 60 Hz / Prime - 480V
1760 kWe / 2200 kVA / 60 Hz / Continuous - 480V
1900 kWe / 2375 kVA / 50 Hz / Standby - 400V
1721 kWe / 2151 kVA / 50 Hz / Prime - 400V
1500 kWe / 1875 kVA / 50 Hz / Continuous - 400V
SYSTEM RATINGS
60 Hz
Voltage (L-L)
Phase
PF
Hz
kW
kVA
Amps
skVA@30%
Voltage Dip
Generator Model
Temp Rise
Connection
50 Hz
480V
3
0.8
60
2,160
2,700
3,251
480V
3
0.8
60
1,955
2,443
2,942
480V
3
0.8
60
1,760
2,200
2,649
400V
3
0.8
50
1,900
2,375
3,432
400V
3
0.8
50
1,721
2,151
3,108
400V
3
0.8
50
1,500
1,875
2,709
5,750
744RDL4056
150 °C/40 °C
5,750
744RDL4056
125 °C/40 °C
5,750
744RDL4056
105 °C/40 °C
4,530
744RDL4056
150 °C/40 °C
4,530
744RDL4056
125 °C/40 °C
4,530
744RDL4056
105 °C/40 °C
4 BAR WYE
4 BAR WYE
4 BAR WYE
4 BAR WYE
4 BAR WYE
4 BAR WYE
CERTIFICATIONS AND STANDARDS
// Emissions
– Fuel Optimized
// Generator set is designed and manufactured
in facilities certified to standards ISO 9001:2008 and
ISO 14001:2004
// Container
– CSC Certified
// Performance Assurance Certification (PAC)
- Generator Set Tested to ISO 8528-5 for Transient Response
- Verified product design, quality and performance integrity
- All engine systems are prototype and factory tested
// Power Rating
- Permissible average power output during 24 hours of
operation is approved up to 85% for standby rated unit.
- Permissible average power output during 24 hours of
operation is approved up to 75% for prime rated unit.
- Permissible average power output during 24 hours of
operation is approved up to 100% for continuous rated unit.
2
/ // / MTU 16V4000 DS1955 (1955 kWe) - Power Module
STANDARD FEATURES*
MTU Onsite Energy is a single source supplier
Global Product Support
Consult factory for specific warranty terms
16V 4000 Diesel Engine
- 76.3 Liter Displacement
- Common Rail Fuel Injection
- 4-Cycle
// Engine-Generator Resilient Mounted
// Complete Range of Accessories
// // // // Generator
- Brushless, Rotating Field Generator
- 2/3 Pitch Windings
- PMG (Permanent Magnet Generator) Supply to Regulator
- 300% Short Circuit Capability
// Digital Control Panel
- Complete System Metering
- LCD Display
// Cooling System
- Remote Mounted / Vertical Split Cores
- Electrically Driven Fans
// STANDARD EQUIPMENT*
// Engine
Air Cleaners
Oil Pump
Oil Drain Extension & S/O Valve
Lube Oil Multi-Stage Filter
Closed Crankcase Ventilation
Jacket Water Pump
Thermostats
Radiator - Remote Mounted
Electric Starting Motor - 24V
Governor – Electronic Isochronous
Base - Formed Steel
SAE Flywheel & Bell Housing
Charging Alternator - 24V
Battery Rack & Cables
Fuel Optimized (Both 60 Hz and 50 Hz)
// Full Amortisseur Windings
125% Rotor Balancing
3-Phase Voltage Sensing
±0.25% Voltage Regulation
100% of Rated Load - One Step
5% Maximum Total Harmonic Distortion
Note: Air filter will cause 5% derate in power output (kWe) and may also
affect fuel consumption.
// Digital Control Panel(s)
Digital Metering
Engine/Generator Protection Functions
CANBus ECU Communications
Multilingual Capability
Programmable Contact Outputs
Generator
NEMA MG1, IEEE and ANSI standards compliance for temperature rise
and motor starting
Sustained short circuit current of up to 300% of the rated current for
up to 10 seconds
Self-Ventilated and Drip-Proof
Superior Voltage Waveform
Digital, Solid State, Volts-per-Hertz Regulator
No Load to Full Load Regulation
Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
2 Bearing, Sealed
Close Coupling
// Container
40’ High Cube ISO Container
Rear Container Double Doors
Three Lockable Personnel Access Doors
1,500 Liters (400 gallons) UL 142 Certified Diesel Fuel Tank
Externally Mounted Critical Grade Exhaust Silencer (stored during
transport between the split core radiator)
NEMA 1 Floor-Standing Generator Set Breaker Panel
Main Line Circuit Breaker Rated at 3200 Amps and 65KAIC
24 VDC Incandescent Lights
Field Adjustable Timer, Factory Set to 60 Minutes
* Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional configurations.
3
/ // / MTU 16V4000 DS1955 (1955 kWe) - Power Module
APPLICATION DATA
// Engine
// Manufacturer
Model 60 Hz Standby
Model 60 Hz Prime
Model 60 Hz Continuous
Model 50 Hz Standby
Model 50 Hz Prime
Model 50 Hz Continuous
Type
Arrangement
Displacement: L (Cu In)
Bore: cm (in)
Stroke: cm (in)
Compression Ratio
Rated RPM: 60 Hz
Rated RPM: 50 Hz
Engine Governor
Standby Rated Power:
MTU
16V 4000 G83 3D
16V 4000 G83 3B
16V 4000 G83 3A
16V 4000 G63 3D
16V 4000 G63 3B
16V 4000 G63 3A
4-Cycle
16-V
76.3 (4,656)
17 (6.69)
21 (8.27)
16.5:1
1,800
1,500
Electronic Isochronous (ADEC)
60 Hz: kWm (hp)
2,500 (3,352)
50 Hz: kWm (hp)
2,185 (2,930)
Prime Rated Power:
60 Hz: kWm (hp)
2,280 (3,057)
50 Hz: kWm (hp)
1,965 (2,635)
Continuous Rated Power: 60 Hz: kWm (hp)
1,950 (2,614)
50 Hz: kWm (hp)
1,635 (2,192)
Speed Regulation
±0.25%
Air Cleaner
Dry
// Fuel Consumption
60 Hz
At 100% of Power Rating:
L/hr (gal/hr)
At 75% of Power Rating:
L/hr (gal/hr)
At 50% of Power Rating:
L/hr (gal/hr)
STANDBY
PRIME
613 (162)
538 (142)
458 (121)
435 (115)
397 (105)
352 (93)
303 (80)
276 (73)
254 (67)
50 Hz
At 100% of Power Rating:
L/hr (gal/hr)
At 75% of Power Rating:
L/hr (gal/hr)
At 50% of Power Rating:
L/hr (gal/hr)
STANDBY
PRIME
// CONTINUOUS
CONTINUOUS
500 (132)
435 (115)
367 (97)
371 (98)
329 (87)
284 (75)
254 (67)
231 (61)
201 (53)
Cooling - Radiator System
Ambient Capacity of Radiator: °C (°F)
Max. Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: kPa (in. H20)
Water Pump Capacity: L/min (gpm)
Heat Rejection to Coolant: kW (BTUM)
Heat Rejection to After Cooler: kW (BTUM)
Fan Power: kW (hp)
55 (131)
0.125 (0.5)
1,350 (357)
**960 (54,593)
**560 (31,846)
99.5 (133.4)
Liquid Capacity (Lubrication)
Total Oil System: L (gal)
Total Oil Change: L (gal)
Engine Jacket Water Capacity: L (gal)
After Cooler Water Capacity: L (gal)
System Coolant Capacity: L (gal)
300 (79.3)
240 (63.4)
175 (46.2)
50 (13.2)
852 (225)
// Air Requirements
Aspirating: *(m3/min) SCFM
Air Flow Required for Rad.
Cooled Unit: *(m3/min) SCFM
**192 (6,780)
3,862 (136,409)
* Air density = 1.184 kg/m3 (0.0739 lbm/ft3)
// Electrical
Electric Volts DC
Cold Cranking Amps Under -17.8 °C (0 °F)
// 24
2,600
Fuel System
Maximum Fuel Lift: m (ft)
Recommended Fuel
Total Fuel Flow: L/hr (gal/hr)
3 (10)
Diesel #2
1,200 (317)
// Exhaust System
Gas Temp. (Stack): °C (°F)
Gas Volume at Stack
Temp: m3/min (CFM)
Maximum Allowable
Back Pressure: kPa (in. H20)
** For 60 Hz Standby Rated Power
**505 (941)
**504 (17,799)
8.5 (34.1)
4
/ // / MTU 16V4000 DS1955 (1955 kWe) - Power Module
WEIGHTS AND DIMENSIONS
Drawing above for illustration purposes only. Do not use for installation design.
System
Power Module
Dimensions (L x W x H)
12,203 x 2,438 x 2,896 mm (480 x 96 x 114 in)
Weight (wet/no fuel)
30,546 kg (67,201 lb)
Weights and dimensions are based on containerized units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
SOUND DATA
Unit Type
Power Module dB(A)
Full Load - Standby
C/F
Full Load - Prime
C/F
Full Load - Continuous
C/F
RATING DEFINITIONS AND CONDITIONS
Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload
capability for this rating. Ratings are in accordance with
ISO 8528-1, ISO-3046-1, BS 5514, and AS 2789. Average
load factor: ≤ 85%. Standby 50 Hz operating hours per year:
Max. 500.
// Prime power and continuous ratings apply to installations
where utility power is unavailable or unreliable. At varying
load for prime power ratings or non-varying load for
continuous ratings, the number of generator set operating
hours is unlimited. A 10% overload capacity is available
for one hour in twelve for both ratings. Ratings are in
accordance with ISO 8528-1, ISO 3046-1, BS 5514, and
AS 2789. Average load factor: ≤ 75% (Prime) ≤ 100%
(Continuous).
// Deration Factor:
Altitude: Consult your local MTU Onsite Energy Power
Generation Distributor for altitude derations.
Temperature: Consult your local MTU Onsite Energy Power
Generation Distributor for temperature derations.
// Product intended for use outside of the United States.
C/F = Consult Factory/MTU Onsite Energy Distributor
N/A = Not Available
MTU Onsite Energy
A Rolls-Royce Power Systems Brand
www.mtuonsiteenergy.com
© MTU Onsite Energy. Subject to alteration due to technological advances. 2015-03
Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infinite exhaust.