Cree XLamp XHP50 LED Data Sheet

Cree® XLamp® XHP50 LEDs
Product Description
FEATURES
Table of Contents
Powered by Cree’s groundbreaking SC5
• Available in white, configurable to 6 V
Characteristics...............................................2
Technology™ Platform, the XLamp XHP50
or 12 V by PCB layout
Flux Characteristics, EasyWhite® Order
LED is a member of Cree’s Extreme
• Available in 5-step EasyWhite® bins
High Power (XHP) class of LEDs that
at 3000 K to 5000 K CCT, 3-step
Flux Characteristics, ANSI White Order
redefines lumen density and reliability
EasyWhite bins at 2700 K to 5000 K
Codes and Bins..............................................7
to radically reduce system costs by up
and 2-step EasyWhite bins at 2700 K
Relative Spectral Power Distribution......... 11
to 40 percent. At its maximum current,
to 4000 K CCT
Relative Flux vs. Junction Temperature..... 11
the XHP50 LED delivers twice the light
output of the industry’s brightest single-die
LED, the XLamp XM-L2 LED, with similar
lumens per watt and without increasing
• Available in ANSI white bins at
3000 K to 7000 K CCT
• Available in standard, 70-, 80-, and
90‑minimum CRI options
Codes and Bins..............................................3
Electrical Characteristics............................ 12
Relative Flux vs. Current............................. 13
Relative Chromaticity vs Current................ 14
Relative Chromaticity vs Temperature....... 15
the package footprint. The XHP50 LED
• Binned at 85 °C
Typical Spatial Distribution......................... 15
also achieves longer lifetime at higher
• Maximum drive current: 3000 mA
Thermal Design........................................... 16
operating temperatures than previous LED
(6 V), 1500 mA (12 V)
Performance Groups – Luminous Flux..... 17
technology. The result is significantly lower
• Low thermal resistance: 1.2 °C/W
Performance Groups – Chromaticity......... 17
thermal, mechanical and optical costs at
• Wide viewing angle: 120°
Cree’s Standard White Chromaticity
the system level.
• Unlimited floor life at
Regions Plotted on the 1931 CIE Curve..... 21
≤ 30 ºC/85% RH
• Reflow solderable - JEDEC
J‑STD‑020C
• RoHS‑compliant
• UL recognized component
®
(E349212)
Cree’s Standard Cool White Kits Plotted
on ANSI Standard Chromaticity Regions... 24
Cree’s Standard Warm and Neutral White
Kits Plotted on ANSI Standard
Chromaticity Regions................................. 25
Bin and Order-Code Format........................ 26
Reflow Soldering Characteristics............... 27
Notes........................................................... 28
www.cree.com/Xlamp
Mechanical Dimensions............................. 29
Electrical Configuration.............................. 31
Tape and Reel.............................................. 31
Packaging.................................................... 32
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo,
XLamp® and EasyWhite® are registered trademarks and SC5 Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks
of UL LLC.
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
1
CLD-DS111 Rev 1B
Product family data sheet
XLamp ® XHP50 LED
Characteristics
XHP50 LEDs are tested and binned in production in the 12‑V configuration. See the Mechanical Dimensions section on page 29 for pad
layout options.
Characteristics
Unit
Thermal resistance, junction to solder point
°C/W
1.2
degrees
120
Temperature coefficient of voltage (6 V)*
mV/°C
-4.5
Temperature coefficient of voltage (12 V)
mV/°C
-9
Viewing angle (FWHM)
ESD withstand voltage (HBM per Mil-Std-883D)
Minimum
Typical
Maximum
V
8000
DC forward current (6 V)*
mA
3000
DC forward current (12 V)
mA
1500
Reverse voltage
V
-5
Forward voltage (6 V, @ 1400 mA, 85 °C)*
V
5.75
6.3
Forward voltage (12 V, @ 700 mA, 85 °C)
V
11.5
12.6
LED junction temperature
°C
150
Note:
* Data for the 6‑V configuration is calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
2
XLamp ® XHP50 LED
Flux Characteristics, EasyWhite® Order Codes and Bins
The following table provides order codes for XLamp XHP50 LEDs. For a complete description of how the flux and chromaticity groups are
reflected in the bin code and order code nomenclature, please see the Bin and Order Code Formats section (page 26).
Binning condition: TJ = 85 °C; 12 V, IF = 700 mA
Reference condition: TJ = 85 °C; 6 V, IF = 1400 mA
CRI
Nominal
CCT
Min
70
80
5000 K
90
Typ
Minimum Luminous Flux
2-Step
3-Step
Group
Flux (lm)
@ 85 °C
Flux (lm)
@ 25 °C*
J4
1120
1284
J2
1040
1192
H4
970
1112
J2
1040
1192
H4
970
1112
H2
900
1032
XHP50A-00-00000D0HH250G
H2
900
1032
XHP50A-00-00000D0UH250G
G4
840
963
XHP50A-00-00000D0UG450G
G2
780
894
F4
730
837
XHP50A-00-00000D0UF450G
F2
680
780
XHP50A-00-00000D0UF250G
Group
Order Code
Group
Order Code
5-Step
Group
Order Code
XHP50A-00-00000D0BJ450E
50E
XHP50A-00-00000D0BJ250E
XHP50A-00-00000D0BH450E
XHP50A-00-00000D0HJ250G
50G
50G
XHP50A-00-00000D0HH450G
XHP50A-00-00000D0UG250G
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
3
XLamp ® XHP50 LED
Flux Characteristics, EasyWhite® Order Codes and Bins - Continued
CRI
Nominal
CCT
Min
70
80
Typ
Minimum Luminous Flux
2-Step
3-Step
Group
Flux (lm)
@ 85 °C
Flux (lm)
@ 25 °C*
J4
1120
1284
J2
1040
1192
H4
970
1112
H4
970
1112
H2
900
1032
G4
840
963
XHP50A-00-00000D0HG445G
G4
840
963
XHP50A-00-00000D0UG445G
G2
780
894
XHP50A-00-00000D0UG245G
F4
730
837
XHP50A-00-00000D0UF445G
F2
680
780
XHP50A-00-00000D0UF245G
J4
1120
1284
J2
1040
1192
H4
970
1112
H4
970
1112
H2
900
1032
G4
840
963
XHP50A-00-00000D0HG440H
XHP50A-00-00000D0HG440G
G4
840
963
XHP50A-00-00000D0UG440H
XHP50A-00-00000D0UG440G
G2
780
894
XHP50A-00-00000D0UG240H
XHP50A-00-00000D0UG240G
F4
730
837
XHP50A-00-00000D0UF440H
F2
680
780
XHP50A-00-00000D0UF240H
Group
Order Code
Group
45E
XHP50A-00-00000D0BJ245E
XHP50A-00-00000D0HH445G
45G
45G
XHP50A-00-00000D0HH245G
XHP50A-00-00000D0BJ440E
40E
XHP50A-00-00000D0BJ240E
XHP50A-00-00000D0BH440E
XHP50A-00-00000D0HH440H
40H
4000 K
90
Order Code
XHP50A-00-00000D0BH445E
90
80
Group
XHP50A-00-00000D0BJ445E
4500 K
70
Order Code
5-Step
40H
XHP50A-00-00000D0HH240H
XHP50A-00-00000D0HH440G
40G
40G
XHP50A-00-00000D0HH240G
XHP50A-00-00000D0UF440G
XHP50A-00-00000D0UF240G
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
4
XLamp ® XHP50 LED
Flux Characteristics, EasyWhite® Order Codes and Bins - Continued
CRI
Nominal
CCT
Min
Typ
Minimum Luminous Flux
Group
Flux (lm)
@ 85 °C
Flux (lm)
@ 25 °C*
H4
970
1112
2-Step
Group
Order Code
3-Step
Group
Order Code
70
80
3500 K
H2
900
1032
H4
970
1112
H2
900
1032
G4
840
963
XHP50A-00-00000D0HG435H
XHP50A-00-00000D0HG435G
G4
840
963
XHP50A-00-00000D0UG435H
XHP50A-00-00000D0UG435G
G2
780
894
XHP50A-00-00000D0HH435H
35H
35H
XHP50A-00-00000D0HH235H
XHP50A-00-00000D0UG235H
F4
730
837
XHP50A-00-00000D0UF435H
F2
680
780
XHP50A-00-00000D0UF235H
H4
970
1112
H2
900
1032
G4
840
963
H4
970
1112
H2
900
1032
80
3000 K
Group
35E
90
70
5-Step
XHP50A-00-00000D0BH435E
XHP50A-00-00000D0BH235E
XHP50A-00-00000D0HH435G
35G
35G
XHP50A-00-00000D0HH235G
XHP50A-00-00000D0UG235G
XHP50A-00-00000D0UF435G
XHP50A-00-00000D0UF235G
XHP50A-00-00000D0BH430E
30E
XHP50A-00-00000D0BH230E
XHP50A-00-00000D0BG430E
XHP50A-00-00000D0HH430H
30H
XHP50A-00-00000D0HH230H
XHP50A-00-00000D0HH430G
30G
XHP50A-00-00000D0HH230G
G4
840
963
XHP50A-00-00000D0HG430H
G2
780
894
XHP50A-00-00000D0HG230H
XHP50A-00-00000D0HG230G
G2
780
894
XHP50A-00-00000D0UG230H
XHP50A-00-00000D0UG230G
F4
730
837
XHP50A-00-00000D0UF430H
XHP50A-00-00000D0UF430G
F2
680
780
XHP50A-00-00000D0UF230H
E4
635
728
XHP50A-00-00000D0UE430H
90
Order Code
30H
30G
XHP50A-00-00000D0HG430G
XHP50A-00-00000D0UF230G
XHP50A-00-00000D0UE430G
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
5
XLamp ® XHP50 LED
Flux Characteristics, EasyWhite® Order Codes and Bins - Continued
CRI
Nominal
CCT
Min
80
Typ
Minimum Luminous Flux
2-Step
Group
Flux (lm)
@ 85 °C
Flux (lm)
@ 25 °C*
H2
900
1032
G4
840
963
G2
780
894
XHP50A-00-00000D0HG227H
XHP50A-00-00000D0HG227G
F4
730
837
XHP50A-00-00000D0UF427H
XHP50A-00-00000D0UF427G
F2
680
780
E4
635
728
Group
Order Code
Group
XHP50A-00-00000D0HH227H
27H
2700 K
90
3-Step
27H
XHP50A-00-00000D0HG427H
XHP50A-00-00000D0UF227H
XHP50A-00-00000D0UE427H
Order Code
5-Step
Group
Order Code
XHP50A-00-00000D0HH227G
27G
27G
XHP50A-00-00000D0HG427G
XHP50A-00-00000D0UF227G
XHP50A-00-00000D0UE427G
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
6
XLamp ® XHP50 LED
Flux Characteristics, ANSI White Order Codes and Bins
The following table provides order codes for XLamp XHP50 LEDs. For a complete description of how the flux and chromaticity groups are
reflected in the bin code and order code nomenclature, please see the Bin and Order Code Formats section (page 26).
Binning condition: TJ = 85 °C; 12 V, IF = 700 mA
Reference condition: TJ = 85 °C; 6 V, IF = 1400 mA
Nominal
CCT
CRI
Chromaticity Regions
Minimum Luminous Flux
Min
Typ
0
68
70
7000 K
0A, 0B, 0C, 0D,
0R, 0S, 0T, 0U,
1A, 1B, 1C, 1D,
1R, 1S, 1T, 1U
80
90
0
70
6500 K
0A, 0B, 0C, 0D,
0R, 0S, 0T, 0U,
1A, 1B, 1C, 1D,
1R, 1S, 1T, 1U,
2A, 2B, 2C, 2D,
2R, 2S, 2T, 2U
80
90
68
Order Code
Group
Flux l(m)
@ 85 °C
Flux (lm)
@ 25 °C*
J4
1120
1284
J2
1040
1192
XHP50A-00-0000-0D00J20DT
J4
1120
1284
XHP50A-00-0000-0D0BJ40DT
J2
1040
1192
XHP50A-00-0000-0D0BJ20DT
XHP50A-00-0000-0D00J40DT
J2
1040
1192
XHP50A-00-0000-0D0HJ20DT
H4
970
1112
XHP50A-00-0000-0D0HH40DT
H2
900
1032
XHP50A-00-0000-0D0HH20DT
H2
900
1032
XHP50A-00-0000-0D0UH20DT
G4
840
963
XHP50A-00-0000-0D0UG40DT
G2
780
894
XHP50A-00-0000-0D0UG20DT
XHP50A-00-0000-0D0UF40DT
F4
730
837
J4
1120
1284
XHP50A-00-0000-0D00J40CB
J2
1040
1192
XHP50A-00-0000-0D00J20CB
J4
1120
1284
XHP50A-00-0000-0D0BJ40CB
J2
1040
1192
XHP50A-00-0000-0D0BJ20CB
J2
1040
1192
XHP50A-00-0000-0D0HJ20CB
H4
970
1112
XHP50A-00-0000-0D0HH40CB
H2
900
1032
XHP50A-00-0000-0D0HH20CB
H2
900
1032
XHP50A-00-0000-0D0UH20CB
G4
840
963
XHP50A-00-0000-0D0UG40CB
G2
780
894
XHP50A-00-0000-0D0UG20CB
F4
730
837
XHP50A-00-0000-0D0UF40CB
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
7
XLamp ® XHP50 LED
Flux Characteristics, ANSI White Order codes and Bins - Continued
Nominal
CCT
CRI
Chromaticity Regions
Minimum Luminous Flux
Min
Typ
0
68
70
6500 K
1A, 1B, 1C, 1D
80
90
0
68
70
6000 K
1A, 1B, 1C, 1D,
1R, 1S, 1T, 1U,
2A, 2B, 2C, 2D,
2R, 2S, 2T, 2U
80
90
0
70
5700 K
2A, 2B, 2C, 2D
80
90
68
Order Code
Group
Flux l(m)
@ 85 °C
Flux (lm)
@ 25 °C*
J4
1120
1284
XHP50A-00-0000-0D00J40E1
J2
1040
1192
XHP50A-00-0000-0D00J20E1
J4
1120
1284
XHP50A-00-0000-0D0BJ40E1
J2
1040
1192
XHP50A-00-0000-0D0BJ20E1
J2
1040
1192
XHP50A-00-0000-0D0HJ20E1
H4
970
1112
XHP50A-00-0000-0D0HH40E1
H2
900
1032
XHP50A-00-0000-0D0HH20E1
H2
900
1032
XHP50A-00-0000-0D0UH20E1
G4
840
963
XHP50A-00-0000-0D0UG40E1
XHP50A-00-0000-0D0UG20E1
G2
780
894
F4
730
837
XHP50A-00-0000-0D0UF40E1
J4
1120
1284
XHP50A-00-0000-0D00J40DV
J2
1040
1192
XHP50A-00-0000-0D00J20DV
J4
1120
1284
XHP50A-00-0000-0D0BJ40DV
J2
1040
1192
XHP50A-00-0000-0D0BJ20DV
J2
1040
1192
XHP50A-00-0000-0D0HJ20DV
H4
970
1112
XHP50A-00-0000-0D0HH40DV
H2
900
1032
XHP50A-00-0000-0D0HH20DV
H2
900
1032
XHP50A-00-0000-0D0UH20DV
G4
840
963
XHP50A-00-0000-0D0UG40DV
G2
780
894
XHP50A-00-0000-0D0UG20DV
F4
730
837
XHP50A-00-0000-0D0UF40DV
J4
1120
1284
XHP50A-00-0000-0D00J40E2
J2
1040
1192
XHP50A-00-0000-0D00J20E2
J4
1120
1284
XHP50A-00-0000-0D0BJ40E2
J2
1040
1192
XHP50A-00-0000-0D0BJ20E2
J2
1040
1192
XHP50A-00-0000-0D0HJ20E2
H4
970
1112
XHP50A-00-0000-0D0HH40E2
H2
900
1032
XHP50A-00-0000-0D0HH20E2
H2
900
1032
XHP50A-00-0000-0D0UH20E2
G4
840
963
XHP50A-00-0000-0D0UG40E2
G2
780
894
XHP50A-00-0000-0D0UG20E2
F4
730
837
XHP50A-00-0000-0D0UF40E2
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
8
XLamp ® XHP50 LED
Flux Characteristics, ANSI White Order codes and Bins - Continued
Nominal
CCT
CRI
Chromaticity Regions
Minimum Luminous Flux
Min
Typ
0
68
70
5000 K
3A, 3B, 3C, 3D
80
90
0
70
4500 K
4A, 4B, 4C, 4D
80
90
68
Order Code
Group
Flux l(m)
@ 85 °C
Flux (lm)
@ 25 °C*
J4
1120
1284
XHP50A-00-0000-0D00J40E3
J2
1040
1192
HP50A-00-0000-0D00J20E3
H4
970
1112
XHP50A-00-0000-0D00H40E3
J4
1120
1284
XHP50A-00-0000-0D0BJ40E3
J2
1040
1192
XHP50A-00-0000-0D0BJ20E3
H4
970
1112
XHP50A-00-0000-0D0BH40E3
J2
1040
1192
XHP50A-00-0000-0D0HJ20E3
H4
970
1112
XHP50A-00-0000-0D0HH40E3
H2
900
1032
XHP50A-00-0000-0D0HH20E3
H2
900
1032
XHP50A-00-0000-0D0UH20E3
G4
840
963
XHP50A-00-0000-0D0UG40E3
G2
780
894
XHP50A-00-0000-0D0UG20E3
F4
730
837
XHP50A-00-0000-0D0UF40E3
F2
680
780
XHP50A-00-0000-0D0UF20E3
J4
1120
1284
XHP50A-00-0000-0D00J40E4
J2
1040
1192
XHP50A-00-0000-0D00J20E4
H4
970
1112
XHP50A-00-0000-0D00H40E4
J4
1120
1284
XHP50A-00-0000-0D0BJ40E4
J2
1040
1192
XHP50A-00-0000-0D0BJ20E4
H4
970
1112
XHP50A-00-0000-0D0BH40E4
H4
970
1112
XHP50A-00-0000-0D0HH40E4
H2
900
1032
XHP50A-00-0000-0D0HH20E4
XHP50A-00-0000-0D0HG40E4
G4
840
963
G4
840
963
XHP50A-00-0000-0D0UG40E4
G2
780
894
XHP50A-00-0000-0D0UG20E4
F4
730
837
XHP50A-00-0000-0D0UF40E4
F2
680
780
XHP50A-00-0000-0D0UF20E4
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
9
XLamp ® XHP50 LED
Flux Characteristics, ANSI White Order codes and Bins - Continued
Nominal
CCT
CRI
Chromaticity Regions
Min
Typ
0
68
70
4000 K
5A, 5B, 5C, 5D
80
90
3500 K
3000 K
6A, 6B, 6C, 6D
7A, 7B, 7C, 7D
Minimum Luminous Flux
70
70
Group
Flux l(m)
@ 85 °C
Flux (lm)
@ 25 °C*
Order Code
J2
1040
1192
XHP50A-00-0000-0D00J20E5
H4
970
1112
XHP50A-00-0000-0D00H40E5
J2
1040
1192
XHP50A-00-0000-0D0BJ20E5
H4
970
1112
XHP50A-00-0000-0D0BH40E5
H4
970
1112
XHP50A-00-0000-0D0HH40E5
H2
900
1032
XHP50A-00-0000-0D0HH20E5
XHP50A-00-0000-0D0HG40E5
G4
840
963
G4
840
963
XHP50A-00-0000-0D0UG40E5
G2
780
894
XHP50A-00-0000-0D0UG20E5
F4
730
837
XHP50A-00-0000-0D0UF40E5
F2
680
780
XHP50A-00-0000-0D0UF20E5
J2
1040
1192
XHP50A-00-0000-0D0BJ20E6
H4
970
1112
XHP50A-00-0000-0D0BH40E6
H2
900
1032
XHP50A-00-0000-0D0BH20E6
J2
1040
1192
XHP50A-00-0000-0D0BJ20E7
H4
970
1112
XHP50A-00-0000-0D0BH40E7
H2
900
1032
XHP50A-00-0000-0D0BH20E7
G4
840
963
XHP50A-00-0000-0D0BG40E7
Notes
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a tolerance of ±2 on CRI
measurements. See the Measurements section (page 28).
•
Cree XLamp XHP50 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
*
Flux values @ 25 °C are calculated and for reference only.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
10
XLamp ® XHP50 LED
Relative Spectral Power
Relative Spectral Power Distribution
100%
Relative Radiant Power
80%
60%
6500 K, 68 CRI
3000 K, 80 CRI
40%
20%
0%
380
430
480
530
580
630
680
730
780
Wavelength (nm)
Relative Flux vs. Junction Temperature
Relative Flux Output vs. Junction Temperature
Reference condition: 6 V, IF = 1400 mA; 12 V, IF = 700 mA
120%
Relative Luminous Flux
100%
80%
60%
40%
20%
0%
25
50
75
100
125
150
Junction Temperature (ºC)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
11
XLamp ® XHP50 LED
Electrical Characteristics (TJ = 85 °C)
3000
Forward Current (mA)
2500
2000
6V
1500
1000
500
0
5.25
5.50
5.75
6.00
6.25
Forward Voltage (V)
Electrical Characteristics (Tj = 85°C)
1500
Forward Current (mA)
1250
1000
750
12 V
500
250
0
10.5
11.0
11.5
12.0
12.5
Forward Voltage (V)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
12
XLamp ® XHP50 LED
Relative Flux vs. Current (TJ = 85 °C)
200%
180%
Relative Luminous Flux
160%
140%
120%
100%
6V
80%
60%
40%
20%
0%
0
500
1000
1500
2000
2500
3000
Forward Current (mA)
Relative Intensity vs. Current (Tj = 85°C)
200%
Relative Luminous Flux
180%
160%
140%
120%
100%
12 V
80%
60%
40%
20%
0%
0
250
500
750
1000
1250
1500
Forward Current (mA)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
13
XLamp ® XHP50 LED
Relative Chromaticity vs Current (Warm White)
0.020
0.016
0.012
6V
0.008
0.004
ΔCCx
0.000
ΔCCy
-0.004
-0.008
-0.012
-0.016
-0.020
0
500
1000
1500
2000
2500
3000
Current (mA)
Relative Chromaticity Vs. Current, WW
0.020
0.016
0.012
12 V
0.008
0.004
ΔCCx
0.000
ΔCCy
-0.004
-0.008
-0.012
-0.016
-0.020
0
250
500
750
1000
1250
1500
Current (mA)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
14
XLamp ® XHP50 LED
Relative Chromaticity vs Temperature (Warm White)
Relative
Chromaticity
Temperature
Reference
condition:
6 V, IF Vs.
= 1400 mA;
12 V,WW
IF = 700 mA
0.020
0.016
0.012
0.008
0.004
ΔCCx
0.000
ΔCCy
-0.004
-0.008
-0.012
-0.016
-0.020
25
50
75
100
125
150
Tj (°C)
Typical Spatial
Distribution
Typical
Spatial Radiation
Pattern
Reference condition: TJ = 85 °C; 6 V, IF = 1400 mA; 12 V, IF = 700 mA
Relative Luminous Intensity
100%
80%
60%
40%
20%
-90
-70
-50
-30
-10
0%
10
30
50
70
90
Angle (º)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
15
XLamp ® XHP50 LED
Thermal Design
The maximum forward current is determined by the thermal resistance between the LED junction and ambient. It is crucial for the end
product to be designed in a manner that minimizes the thermal resistance from the solder point to ambient in order to optimize lamp life
and optical characteristics.
3200
Maximum Current (mA)
2800
6V
2400
2000
1600
1200
Rj-a = 2°C/W
Rj-a = 4°C/W
800
Rj-a = 6°C/W
400
0
Rj-a = 8°C/W
0
20
40
60
80
100
120
140
160
Ambient Temperature (ºC)
Thermal Design
1600
Maximum Current (mA)
1400
12 V
1200
1000
800
600
Rj-a = 2°C/W
Rj-a = 4°C/W
400
Rj-a = 6°C/W
200
0
Rj-a = 8°C/W
0
20
40
60
80
100
120
140
160
Ambient Temperature (ºC)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
16
XLamp ® XHP50 LED
Performance Groups – Luminous Flux (TJ = 85 °C)
XLamp XHP50 LEDs are tested for luminous flux and placed into one of the following luminous-flux groups.
Group Code
Min. Luminous Flux
Max. Luminous Flux
E4
635
680
F2
680
730
F4
730
780
G2
780
840
G4
840
900
H2
900
970
H4
970
1040
J2
1040
1120
J4
1120
1200
Performance Groups – Chromaticity
XLamp XHP50 LEDs are tested for chromaticity and placed into one of the regions defined by the following bounding coordinates.
EasyWhite Color Temperatures – 2-Step
Bin Code
40H
35H
30H
27H
CCT
4000 K
3500 K
3000 K
2700 K
x
y
0.3777
0.3739
0.3797
0.3816
0.3861
0.3855
0.3838
0.3777
0.4022
0.3858
0.4053
0.3942
0.4125
0.3977
0.4091
0.3891
0.4287
0.3975
0.4328
0.4064
0.4390
0.4086
0.4347
0.3996
0.4524
0.4048
0.4574
0.4140
0.4633
0.4154
0.4581
0.4062
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
17
XLamp ® XHP50 LED
Performance Groups – Chromaticity (continued)
EasyWhite Color Temperatures – 3-Step Ellipse
Major Axis
Minor Axis
x
y
a
b
Rotation Angle
(°)
5000 K
0.3447
0.3553
0.00840
0.00312
65.0
45G
4500 K
0.3611
0.3658
0.00852
0.00330
61.5
40G
4000 K
0.3818
0.3797
0.00939
0.00402
53.7
35G
3500 K
0.4073
0.3917
0.00927
0.00414
54.0
30G
3000 K
0.4338
0.4030
0.00834
0.00408
53.2
27G
2700 K
0.4577
0.4099
0.00834
0.00420
48.5
Major Axis
Minor Axis
Bin Code
CCT
50G
Center Point
EasyWhite Color Temperatures – 5-Step Ellipse
Center Point
Bin Code
CCT
50E
5000 K
x
y
a
b
Rotation Angle
(°)
0.3447
0.3553
0.01400
0.00520
65.0
45E
4500 K
0.3611
0.3658
0.01420
0.00550
61.5
40E
4000 K
0.3818
0.3797
0.01565
0.00670
53.7
35E
3500 K
0.4073
0.3917
0.01545
0.00690
54.0
30E
3000 K
0.4338
0.4030
0.01390
0.00680
53.2
ANSI White Bins
CCT
Bin Code
0A0
0B0
7000 K
0C0
0D0
ANSI White Bins
x
y
0.2950
0.2970
0.2920
0.3060
0.2984
0.3133
CCT
Bin Code
0R0
ANSI White Bins
x
y
0.2980
0.2880
0.2950
0.2970
0.3009
0.3042
CCT
Bin Code
1A0
x
y
0.3048
0.3207
0.3130
0.3290
0.3144
0.3186
0.3009
0.3042
0.3037
0.2937
0.3068
0.3113
0.2920
0.3060
0.2895
0.3135
0.3028
0.3304
0.2895
0.3135
0.2870
0.3210
0.3115
0.3391
0.2962
0.3220
0.2937
0.3312
0.3130
0.3290
0.2984
0.3133
0.2962
0.3220
0.3048
0.3207
0.2984
0.3133
0.2962
0.3220
0.3115
0.3391
0.2962
0.3220
0.2937
0.3312
0.3205
0.3481
0.3028
0.3304
0.3005
0.3415
0.3213
0.3373
0.3048
0.3207
0.3028
0.3304
0.3130
0.3290
0S0
7000 K
0T0
1B0
7000 K
1C0
0.2984
0.3133
0.3037
0.2937
0.3130
0.3290
0.3048
0.3207
0.3009
0.3042
0.3213
0.3373
0.3068
0.3113
0.3068
0.3113
0.3221
0.3261
0.3009
0.3042
0.3093
0.2993
0.3144
0.3186
0U0
1D0
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
18
XLamp ® XHP50 LED
Performance Groups – Chromaticity (continued)
ANSI White Bins
CCT
Bin Code
1R0
1S0
7000 K
1T0
1U0
ANSI White Bins
x
y
0.3068
0.3113
CCT
0.3144
0.3186
Bin Code
2A0
ANSI White Bins
x
y
0.3215
0.3350
CCT
0.3290
0.3417
Bin Code
2R0
x
y
0.3222
0.3243
0.3290
0.3300
0.3161
0.3059
0.3290
0.3300
0.3290
0.3180
0.3093
0.2993
0.3222
0.3243
0.3231
0.3120
0.3005
0.3415
0.3207
0.3462
0.3196
0.3602
0.3099
0.3509
0.3115
0.3391
0.3028
0.3304
0.3099
0.3509
0.3196
0.3602
0.3205
0.3481
0.3115
0.3391
2B0
6000 K
2C0
0.3290
0.3538
0.3290
0.3417
0.3215
0.3350
0.3290
0.3538
0.3376
0.3616
0.3371
0.3490
0.3290
0.3417
2S0
6000 K
2T0
0.3290
0.3690
0.3290
0.3538
0.3207
0.3462
0.3290
0.3690
0.3381
0.3762
0.3376
0.3616
0.3290
0.3538
0.3144
0.3186
0.3290
0.3417
0.3290
0.3300
0.3221
0.3261
0.3371
0.3490
0.3366
0.3369
0.3231
0.3120
0.3366
0.3369
0.3361
0.3245
0.3161
0.3059
0.3290
0.3300
0.3290
0.3180
2D0
ANSI White Bins
CCT
Bin Code
3A0
3B0
5000 K
3C0
3D0
2U0
ANSI White Bins
x
y
CCT
Bin Code
x
y
.3371
.3451
.3490
0.3530
0.3597
.3554
0.3615
.3440
.3427
0.3659
0.3512
0.3465
.3366
.3369
0.3515
0.3487
.3376
.3616
0.3548
0.3736
.3463
.3687
0.3641
0.3804
.3451
.3554
0.3530
0.3597
.3371
.3490
.3463
.3687
.3551
.3760
.3533
.3620
.3451
.3554
.3451
.3554
.3533
.3620
.3515
.3487
.3440
.3427
4A0
4B0
4500 K
4C0
4D0
0.3533
0.362
0.3641
0.3804
0.3736
0.3874
0.3702
0.3722
0.3615
0.3659
0.3615
0.3659
0.3702
0.3722
0.3670
0.3578
0.3590
0.3521
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
19
XLamp ® XHP50 LED
Performance Groups – Chromaticity (continued)
ANSI White Bins
CCT
Bin Code
5A0
5B0
4000 K
5C0
5D0
ANSI White Bins
x
y
.3670
.3578
.3702
.3722
CCT
Bin Code
6A0
ANSI White Bins
x
y
.3889
.3690
.3941
.3848
CCT
Bin Code
7A0
x
y
.4147
.3814
.4221
.3984
.3825
.3798
.4080
.3916
.4342
.4028
.3783
.3646
.4017
.3751
.4259
.3853
.3702
.3722
.3941
.3848
.4221
.3984
.3736
.3874
.3869
.3958
.3825
.3798
.3825
.3798
6B0
3500 K
.3996
.4015
.4146
.4089
.4080
.3916
.4080
.3916
.4089
.4165
.4221
.3984
.4165
.4212
.4342
.4028
.4342
.4028
.3869
.3958
.4044
.3950
.3875
.3783
.3646
.4017
.3751
.4259
.3853
.3825
.3798
.4080
.3916
.4342
.4028
.3950
.3875
.4221
.3984
.4465
.4071
.3898
.3716
.4147
.3814
.4373
.3893
6D0
.4146
3000 K
.4299
.4430
.4006
6C0
.4299
7B0
7C0
7D0
.4430
.4212
.4562
.4260
.4465
.4071
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
20
XLamp ® XHP50 LED
Cree’s Standard White Chromaticity Regions Plotted on the 1931 CIE Curve
ANSI Cool White
0.40
5000 K
0.39
5700 K
0.38
0.37
6500 K
2T
0.36
2S
CCy
0.35
2C
1T
8000 K
2B
1S
0.34
0T
0.33
0S
0.32
0B
0.31
1D
2U
ANSI
C78.377A
2R
1A
1U
0D
0A
0.30
2A
1B
0C
2D
1C
1R
0U
0R
0.29
0.36
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.28
0.28
CCx
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
21
XLamp ® XHP50 LED
Cree’s Standard White Chromaticity Regions Plotted on the 1931 CIE Curve - Continued
ANSI Neutral White and ANSI Warm White
0.45
0.44
2700 K
3000 K
0.43
0.42
3500 K
0.41
4000 K
6C
0.40
CCy
7C
7B
0.39
5000 K
0.38
4C
0.37
3C
3B
3D
0.35
4B
7D
7A
5C
6D
5B
5700 K
0.36
6B
4500 K
5D
6A
5A
ANSI
C78.377A
4D
4A
3A
0.34
0.50
0.49
0.48
0.47
0.46
0.45
0.44
0.43
0.42
0.41
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0.33
0.32
0.33
CCx
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
22
XLamp ® XHP50 LED
Cree’s Standard White Chromaticity Regions Plotted on the 1931 CIE Curve - Continued
0.44
ANSI C78.377 Quadrangle
0.43
EasyWhite 5-Step
EasyWhite 3-Step
0.42
3500 K
EasyWhite 2-Step
0.41
2700 K
3000 K
4000 K
0.40
4500 K
0.39
5000 K
0.38
CCy
0.37
5700 K
0.36
6500 K
0.35
0.34
8000 K
0.33
0.32
0.31
0.30
0.29
0.49
0.48
0.47
0.46
0.45
0.44
0.43
0.42
0.41
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.28
CCx
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
23
XLamp ® XHP50 LED
Cree’s Standard Cool White Kits Plotted on ANSI Standard Chromaticity Regions
0.40
0.40
5000 K
0.39
0.38
0.38
5700 K
0.37
5700 K
0.37
6500 K
CB
2C
1T
8000 K
0.34
0T
0C
0A
ANSI
C78.377A
2R
1U
0D
0S
0.32
0B
1R
0A
ANSI
C78.377A
1U
1R
0U
0.36
0.30
0.28
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.28
0.36
0.28
0.35
0R
0.29
0.29
2U
2R
1A
0.30
0.29
0.28
2A
1D
0D
0R
CCx
CCx
0.40
0.40
5000 K
0.39
0.38
0.38
DV
6500 K
0.36
0.36
2C
8000 K
0A
0R
1R
0U
CCx
0.36
0.35
0.34
0.28
0.36
0.35
0.34
0.33
0.32
0.28
0.31
0.28
0.30
ANSI
C78.377A
2R
1U
0R
0.29
0.29
2U
1A
0D
0.30
0.29
0.28
0C
0B
0.31
1R
0U
0.30
0S
0.32
1D
0.33
0A
CCy
1U
3R
2A
1B
0.32
0.31
ANSI
C78.377A
2R
1A
0D
0T
0.33
2U
3A
2D
1C
0.31
0C
0B
1D
2C
2B
1S
0.30
0S
0.32
2A
1B
3B
2S
1T
8000 K
0.34
0.29
0T
0.33
2D
1C
2T
E1
0.35
2B
1S
3S
6500 K
2T
1T
0.34
5700 K
0.37
2S
0.35
5000 K
0.39
5700 K
0.37
CCy
2D
1C
1B
0C
0.31
0U
0.30
0T
0.33
2U
1D
1A
2B
0.34
0B
0.31
2A
2C
1T
1S
0.33
0S
0.32
2D
1C
1B
DT
8000 K
0.34
0.32
0.33
2S
0.35
2B
1S
2T
0.36
0.31
0.35
6500 K
2T
2S
CCy
0.36
CCy
5000 K
0.39
CCx
0.40
5000 K
0.39
0.38
5700 K
E2
0.37
6500 K
0.36
3B
2S
0.35
CCy
3S
2T
2C
1T
8000 K
0.34
0T
0.33
0S
0.32
0C
0A
3R
2A
2U
1D
ANSI
C78.377A
2R
1A
0D
2D
1C
1B
0B
0.31
3A
2B
1S
1U
1R
0U
0.30
0R
0.29
0.36
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.28
0.28
CCx
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
24
XLamp ® XHP50 LED
Cree’s Standard Warm and Neutral White Kits Plotted on ANSI Standard Chromaticity Regions
0.45
0.44
2700 K
3000 K
0.43
E7
0.42
3500 K
4000 K
CCy
0.40
0.39
5000 K
0.38
E4
4B
3C
0.36
3B
3D
0.35
7B
6C
6B
7D
7A
5C
6D
5B
4C
E3
0.37
E5
4500 K
7C
E6
0.41
6A
ANSI
C78.377A
5D
5A
4D
4A
3A
0.34
0.50
0.49
0.48
0.47
0.46
0.45
0.44
0.43
0.42
0.41
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0.33
0.32
0.33
CCx
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
25
XLamp ® XHP50 LED
Bin and Order-Code Format
Bin codes and order codes for XHP50 LEDs are configured in the following manner:
Order Code
Bin Code
Series
XHP50A = XHP50
Series
XHP50A = XHP50
Internal code
Chromaticity group
Minimum luminous flux group
Vf Class
D = 6-V/12-V configurable
SSSSSS-BD-GGGG-HJKLMMNNN
Chromaticity group
CRI specification
0 = No Minimum CRI
B = 70 CRI Minimum
H = 80 CRI Minimum
U = 90 CRI Minimum
Vf Class
D = 6-V/12-V configurable
Configuration
B = Internal code
D = Reel size
CRI specification
0 = No minimum CRI
B = 70 CRI minimum
H = 80 CRI minimum
U = 90 CRI minimum
SSSSSS-E-NNN-MMM-JK-L-PP
Internal code
Voltage performance group
Luminous flux group
Internal code
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
26
XLamp ® XHP50 LED
Reflow Soldering Characteristics
In testing, Cree has found XLamp XHP50 LEDs to be compatible with JEDEC J‑STD‑020C, using the parameters listed below. As a general
guideline, Cree recommends that users follow the recommended soldering profile provided by the manufacturer of the solder paste used.
Note that this general guideline may not apply to all PCB designs and configurations of reflow soldering equipment.
tP
TP
Critical Zone
TL to TP
Temperature
Ramp-up
TL
tS
Tsmax
Tsmin
Ramp-down
ts
Preheat
25
t 25˚C to Peak
Profile Feature
Average Ramp-Up Rate (Tsmax to Tp)
Time
Lead-Free Solder
1.2 °C/second
Preheat: Temperature Min (Tsmin)
120 °C
Preheat: Temperature Max (Tsmax)
170 °C
Preheat: Time (tsmin to tsmax)
65-150 seconds
Time Maintained Above: Temperature (TL)
Time Maintained Above: Time (tL)
217 °C
45-90 seconds
Peak/Classification Temperature (Tp)
235 - 245 °C
Time Within 5 °C of Actual Peak Temperature (tp)
20-40 seconds
Ramp-Down Rate
1 - 6 °C/second
Time 25 °C to Peak Temperature
4 minutes max.
Note: All temperatures refer to the topside of the package, measured on the package body surface.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
27
XLamp ® XHP50 LED
Notes
Measurements
The luminous flux, radiant power, chromaticity and CRI measurements in this document are binning specifications only and solely
represent product measurements as of the date of shipment. These measurements will change over time based on a number of factors
that are not within Cree’s control and are not intended or provided as operational specifications for the products. Calculated values are
provided for informational purposes only and are not intended as specifications.
Lumen Maintenance
Cree now uses standardized IES LM-80-08 and TM-21-11 methods for collecting long-term data and extrapolating LED lumen maintenance.
For information on the specific LM‑80 data sets available for this LED, refer to the public LM-80 results document.
Please read the Long-Term Lumen Maintenance application note for more details on Cree’s lumen maintenance testing and forecasting.
Please read the Thermal Management application note for details on how thermal design, ambient temperature, and drive current affect
the LED junction temperature.
Moisture Sensitivity
Cree recommends keeping XLamp LEDs in the provided, resealable moisture-barrier packaging (MBP) until immediately prior to soldering.
Unopened MBPs that contain XLamp LEDs do not need special storage for moisture sensitivity.
Once the MBP is opened, XLamp XHP50 LEDs may be stored as MSL 1 per JEDEC J-STD-033, meaning they have unlimited floor life in
conditions of ≤ 30 ºC/85% relative humidity (RH). Regardless of the storage condition, Cree recommends sealing any unsoldered LEDs
in the original MBP.
RoHS Compliance
The levels of RoHS restricted materials in this product are below the maximum concentration values (also referred to as the threshold
limits) permitted for such substances, or are used in an exempted application, in accordance with EU Directive 2011/65/EC (RoHS2), as
implemented January 2, 2013. RoHS Declarations for this product can be obtained from your Cree representative or from the Product
Documentation sections of www.cree.com.
UL® Recognized Component
Level 4 enclosure consideration. The LED package or a portion thereof has been investigated as a fire and electrical enclosure per ANSI/
UL 8750.
Vision Advisory
WARNING: Do not look at exposed lamp in operation. Eye injury can result. For more information about LEDs and eye safety, please refer
to the LED Eye Safety application note.
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
28
XLamp ® XHP50 LED
Mechanical Dimensions
Thermal vias, if present, are not shown on these drawings.
All dimensions are ±.13 mm unless otherwise indicated.
.73
.73
5.00
5.00
4.78
4.78
2.78
2.78
.50
.50
.50
.50
.50
.50
R2.85
R2.85
.50
.50
5.00
5.00
4.78
2.14
2.14
Side View
Top View
.73
.73
.50
.50
.50
4.78
4.78
2.78
2.78
4.78
.50
.50.50
.50
4.78
.50
.50
2.78
R2.85
4.78 REF. 4.78 REF.
.50
2.78
.50
Anode
Side
Cathode
Side
.50
4.78
4.78
4.78
PRIMARY
PRIMARY
3.58
3.58
2.14
4.78
4.78
4.78
.50
.50
.50
.50
Anode
Side 2.14
2.14
.50
2.14
Cathode
Side
4.78 REF. 4.78 REF.
.50
4.78
.50
4.78
.50
.80
2.14
3.58
ALTERNATIVE
ALTERNATIVE
PRIMARY
Alternate
Bottom
Bottom
View
PRIMARY .50
.50View
.50
As shown in these bottom views,.50thermal .50
pad is electrically isloated
3.58
.25
.50
.25
.80
.50
.50
2.14
RECOMMENDED
PCB SOLDER PAD
RECOMMENDED
PCB SOLDER PAD
12V
12V
RECOMMENDED
PCB SOLDER PAD
RECOMMENDED
PCB SOLDER PAD
6V
6V
4.78
4.78
4.78
.80
.50
.50
.50
.50
2.14
2.14
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™
is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
2.14
2.14
4.78
.50
.50
.50
.504.78
4.78
4.78 .25
.25
.50
.50
29
2.14
2.14
PRIMARY
PRIMARY
3.58
3.58
XLamp ® XHP50 LED
Mechanical Dimensions - Continued
4.78
2.78
.50
4.78
4.78
.50
.50.50
.50
4.78 REF.
4.78
4.78
.50.50
2.78
2.78
.50.50
.50.50
.50
2.14
2.14
4.78
4.78
4.78
4.78 REF.
4.78
4.78
.50.50
2.14
.50.50
.25.25
4.78
4.78
.80.80
2.14
2.14
PRIMARY
ALTERNATIVE
.50.50
.50.50
.50.50
Recommended PCB Solder Pad 6 V Configuration
(thermal
pad is electrically
isolated)
RECOMMENDED
PCB
SOLDER
PAD
RECOMMENDED
PCB
SOLDER
PAD
6V6V
RE
Recommended PCB Solder Pad 12 V Configuration
(thermal padRECOMMENDED
is
connectedPCB
to
anode
and
RECOMMENDED
PCB
SOLDER
PAD cathode and is not
SOLDER
PAD
12V isolated)
12V
electrically
.25
.80
4.78
.50
.50
.50
2.14
4.78
.50
.50
.25
4.78
.80
2.14
.50
COMMENDED PCB SOLDER PAD
12V
.97
4.78
Recommended
Stencil
Pattern
RECOMMENDED STENCIL
PATTERN
(HATCHED
IS OPENING)
6 V
& 12 VAREA
Configurations
6v/12v
(shaded area is open)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
30
POSITIVE A
NEGATIVE B
XLamp ® XHP50 LED
Electrical Configuration
12 V
6V
SOLDER PAD LINK
NEGATIVE A
POSITIVE A
NEGATIVE B
POSITIVE B
6
6
OTICE
THIS PLOT AND THE INFORMATION
RE THE PROPRIETARY AND
MATION OF CREE, INC. THIS PLOT
REPRODUCED OR DISCLOSED TO ANY
ON WITHOUTTHE WRITTEN CONSENT
NEGATIVE B
5
NOTICE
CREE CONFIDENTIAL. THIS PLOT AND THE INFORMATION
CONTAINED WITHIN ARE THE PROPRIETARY AND
CONFIDENTIAL INFORMATION OF CREE, INC. THIS PLOT
MAY NOT BE COPIED, REPRODUCED OR DISCLOSED TO ANY
UNAUTHORIZED PERSON
5 WITHOUTTHE WRITTEN CONSENT
OF CREE INC.
6-V Configuration
POSITIVE A
4
3
REV
B
4
3
12-V Configuration
6V
D
2
REVISONS
REV
DESCRIPTION
B
REVERSED POLARITY IN VIEW
Tape and Reel
All Cree carrier tapes conform to EIA-481D, Automated Component Handling Systems Standard.
NEGATIVE A
4
1.5
All dimensions are ±.13 mm unless otherwise indicated.
1.5
4
8
CATHODE SIDE
User Feed Direction
4
8
END
User Feed Direction
NEGATIVE B
END
POSITIVE A
CATHODE SIDE
1.75
START
POSITIVE B
4
1.75
START
3.7
12
C
ANODE SIDE
Trailer
160mm (min) of
empty pockets
sealed with tape
(15 pockets min.)
Trailer
160mm (min) of
empty pockets
ANODE
sealed with
tape
(15 pockets min.)
Loaded Pockets
(500 Lamps)
Loaded Pockets
(500 Lamps)
SIDE
Leader
400mm (min.) of
empty pockets with
at least 100mm
sealed by tape
(40 empty pockets min.)
12
Leader
400mm (min.) of
empty pockets with
at least 100mm
sealed by tape
(40 empty pockets min.)
5.3
0.36
User Feed Direction
B
User Feed Direction
13mm
13mm
7.0"
A
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree , the Cree
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
®
7.0"
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN
MILLIMETERS AND AFTER FINISH.
TOLERANCE UNLESS SPECIFIED:
.XX ±
.25
logo, XLamp® and EasyWhite® are registered trademarks and
SC5± .125
.XXX
X°
±
.5 °
DATE
DRAWN BY
THIRD
ANGLE
PROJECTION
UNLESS OTHERWISE SPECIFIED
D. CRONIN
12/9/14 FOR SHEET METAL PARTS ONLY
DIMENSIONS ARE IN
.X
±
1.5
CHECK
DATE
MILLIMETERS AND AFTER FINISH.
.XX ±
.75
--TOLERANCE UNLESS SPECIFIED:
.XXX ±
.25
.XX ±
.25
APPROVED
DATE
X°
±
.5 °
TITLE
.XXX ±
.125
--SURFACE FINISH: 1.6
D
C
A
M
31
F
XLamp ® XHP50 LED
Packaging
Unpackaged Reel
Vacuum-Sealed
Vacuum-Sealed
Moisture
Barrier Bag
Moisture Barrier Bag
Label
CREE
Binwith
Code Cree Bin
&
Barcode
LabelLot #
Code,
Qty,
Label with Cree Bin Code,
Quantity, Reel ID
Label
with
Cree Bin
Label with
Customer
P/N, Qty,Qty,
Lot #, Lot
PO # #
Code,
Packaged Reel
Patent Label
Label with Customer Order
Label
with Cree Order Code,
Code, Qty, Reel ID, PO #
Quantity, Reel ID, PO #
Label with Cree Bin Code,
Quantity, Reel ID
Boxed Reel
Label with Cree Order Code,
Quantity, Reel ID, PO #
Label with Cree Bin Code,
Quantity, Reel ID
Patent Label
(on bottom of box)
Copyright © 2014-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree®, the Cree logo, XLamp® and EasyWhite® are registered trademarks and SC5
Technology™ is a trademark of Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
32