SIOY3SV2_N

SIOY3SV2
Current Sensors
Features
 Hall effect measuring principle
 Galvanic isolation between primary and
secondary circuit
 Isolation voltage 3000 V
 Low power consumption
 Extended measuring range (3 *IPN)
 Insulated plastic case recognized according
to UL 94-V0
IPN = 40…1500A VOUT = ± 4 V
Advantages
Industrial applications
 Easy installation
 Small size and space saving
 Only one design for wide current ratings
range
 High immunity to external interference
Type
SIOY3S400V2
SIOY3S500V2
SIOY3S600V2
SIOY3S800V2
SIOY3S1000V2
SIOY3S1200V2
SIOY3S1500V2






DC motor drives
Switched Mode Power Supplies(SMPS)
AC variable speed drives
Uninterruptible Power Supplies(UPS)
Battery supplied applications
Power supplies for welding applications
TYPES OF PRODUCTS
Primary current measuring range
Primary nominal current
IP (A)
r. m. s IPN (A)
400
500
600
800
1000
1200
1500
±1200
±1500
±1800
±2400
±2500
±2500
±2500
General Description
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between
the primary circuit and the secondary circuit.
1
V2.00 May 1, 2012
SIOY3SV2
Current Sensors
Parameters Table
PARAMETERS
SYMBOL
UNIT
Electrical data
V
mA
VALUE
Supply voltage(±5%)(1)
Current consumption
VC
IC
Output voltage
Vout
V
±4V
Isolation resistance
Output internal resistance
Load resistance(2)
RIS
ROUT
RL
MΩ
Ω
KΩ
>1000
100
>10
CONDITIONS
±15
±15
@ ± IPN, RL = 10 kΩ,
TA = 25°C
@ 500 VDC
Accuracy - Dynamic performance data
Linearity (0…±IPN)
εL
% of IPN
<±1
Accuracy
X
% of IPN
<±1
@ IPN, TA = 25°C
(excluding offset)
Electrical offset voltage
VOE
mV
<±20
@TA = 25°C
Hysteresis offset voltage
VOH
mV
<±10
@ IP= 0
after an excursion of 1* IPN
Temperature coefficient of VOE
TCVOE
mV/K
<1
Temperature coefficient of
VOUT
TCVOUT
%/K
<±0.1
tr
μS
<5
@ 90% of IPN step
BW
kHz
DC~25
@-3dB
(3)
Response time
Frequency bandwidth(4)
Ambient operating temperature
Ambient storage temperature
Mass
Rated isolation voltage rms
Rms voltage for AC isolation
test
Creepage distance
Clearance distance
Comparative Tracking Index
General data
TA
°C
-40 ~ +85
TS
°C
-40 ~ +105
m
g
300
Isolation characteristics
Vb
V
1000
Vd
KV
3
50 Hz, 1 min
dCp
dCI
CTI
mm
mm
>11
>11
275
Group IIIa
Notes:
1) Operating at ±12V ≤VC<±15V will reduce the measuring range.
2) If the customer uses 10KΩ of the load resistor, the primary current has to be limited as the
nominal.
3) Linearity data exclude the electrical offset.
4) Please refer to derating curves in the technical file to avoid excessive core heating at high
frequency.
2
V2.00 May 1, 2012
SIOY3SV2
Current Sensors
Dimensions SIOY3SV2 (in mm. 1 mm = 0.0394 inch)
Instructions of use
1) When the test current passes through the sensors you can get the size of the output
voltage.(Warning: wrong connection may lead to sensors damage)
2) Based on user needs, the sensors output range can be appropriately regulated.
3) According to user needs, different rated input currents and output voltages of the sensors can be
customized.
3
V2.00 May 1, 2012
SIOY3SV2
Current Sensors
RESTRICTIONS ON PRODUCT USE
The information contained herein is subject to change without notice.
SEC ELECTRONICS INC. (for short SEC) exerts the greatest possible effort to ensure high quality
and reliability. Nevertheless, semiconductor devices in general can malfunction or fail due to their
inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer,
when utilizing SEC products, to comply with the standards of safety in making a safe design for the
entire system, including redundancy, fire-prevention measures, and malfunction prevention, to prevent
any accidents, fires, or community damage that may ensue. In developing your designs, please ensure
that SEC products are used within specified operating ranges as set forth in the most recent SEC
products specifications.
The SEC products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic
appliances, etc.). These SEC products are neither intended nor warranted for usage in equipment that
requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause
loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation instruments, traffic signal
instruments, combustion control instruments, medical instruments, all types of safety devices, etc..
Unintended Usage of SEC products listed in this document shall be made at the customer’s own risk.
4
V2.00 May 1, 2012