Current Transducers HAZ 4000..20000-SB IPN = 4000..20000 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). VOUT= ± 10 V Electrical data Primary nominal DC current or AC peak IPN (A) 4000 6000 10000 12000 14000 20000 VC IC ÎP RIS VOUT ROUT RL Primary current measuring range IPM (A) ± ± ± ± ± ± 4000 6000 10000 12000 14000 20000 Type RoHS since date code Features HAZ HAZ HAZ HAZ HAZ HAZ 4000-SB 6000-SB 10000-SB 12000-SB 14000-SB 20000-SB 46177 46177 46177 planned planned planned Supply voltage (± 5 %) ± 15 Current consumption ± 30 Overload capability 30,000 Isolation resistance @ 500 VDC > 1000 Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C ± 10 Output internal resistance approx.100 Load resistance > 10 • Hall effect measuring principle • Galvanic isolation between primary and secondary circuit V mA A MΩ V Ω kΩ Accuracy - Dynamic performance data X ε Accuracy @ IPN, TA = 25°C (excluding offset) Linearity error 1) (0 .. ± IPN) Electrical offset voltage @ TA = 25°C, IP = 0 Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Temperature coefficient of VOE Temperature coefficient of VOUT (% of reading) Response time to 90% of IPN step Reaction time @ 10% of IPN di/dt accurately followed Frequency bandwidth, ± 3 dB, small signal 2) L VOE VOH TCVOE TCVOUT tr tra di/dt BW <±1 % < ± 0.5 % of IPN < ± 50 mV < ± 12.5 <±1 < ± 0.05 < 10 <2 > 50 DC .. 3 mV mV/K %/K µs us A/µs kHz General data TA TS Notes : 1) 2) 3) /1min • Low power consumption • Package in PBT meeting UL 94-V0 • Instantaneous voltage output Advantages • Easy installation • Small size and space savings • Only one design for wide current ratings range • High immunity against external interference Applications • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Power supplies for welding and telecom applications. Application domain Ambient operating temperature Ambient storage temperature Housing PBT 30% glassfiber Mass Standard 3) m • Instantaneous voltage output • Isolation voltage 12kV Rms /50 Hz - 25 .. + 85 - 30 .. + 90 °C °C • Industrial approx. 6 kg EN 50178:1997 Linearity data exclude the electrical offset. To avoid excessive core heating Please consult characterisation report for more technical details and application advice. Page 1/3 070219/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer HAZ 4000..20000-SB Isolation characteristics Vb Vb Vd Ve Vw dCp dCl CTI Rated isolation voltage rms with IEC 61010-1 standard and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field Rated isolation voltage rms with EN 50178 standard and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field Rms voltage for AC isolation test, 50 Hz, 1 min Partial discharge extinction voltage rms @ 10pC Impulse withstand voltage 1.2/50 µs Creepage distance Clearance distance Comparative Tracking Index (Group IIIa) 2000 V 2000 V 12 >3 27 > 45 > 45 220 kV kV kV mm mm Page 2/3 070219/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HAZ 4000..20000-SB (in mm. 1 mm = 0.0394 inch) FUJICON F2023A 6 48 50 6 N.C. 5 4 3 GND OUTPUT Connection Circuit 1 2 0V -Vc 1 +Vc HAZxxx-SB HAZ 10000-SB 250 +/-1.5 1 +Vc 2 -Vc 3 0V 235 4-D6 OUTPUT 5 GND 6 42 41.5 ±2 1.5 42+/-1 125 160 +/-1.5 65 4 RL=10K ohm N.C. 162 161 ± 12 162+/-1 75 Operation Principle 7.5 +Vc 50 48 35 200 Terminal M5 1...+Vc 2...-Vc 3...0V 4...OUTPUT 5...GND 6...N.C. General tolerance +/-0.5 Mechanical characteristics • General tolerance • Aperture for primary conductor ± 0.5 mm 162 mm x 42 mm (± 2 mm) • Transducer fastening 4 x M5 (not supplied) • Recommended fastening torque < 5 Nm • Connection of secondary Fujicon F2023A (6 terminals) Remarks • Temperature of the primary conductor should not exceed 120°C. • VOUT is positive when IP flows in the direction of the arrow. Output 0V Ip -Vc Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 3/3 070219/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com