SY01-S3F - Raltron Electronics Corporation

SYNCHRONOUS EQUIPMENT
OCXO BASED STRATUM 3 CLOCK UNIT WITH A 2 ND FREE-RUN
CLOCK OUTPUT – SY01-S3F
SY01-S3F
Date: April 20 , 2002
•
INTRODUCTION
The SY01-S3F is an accurate time and frequency source that has
been designed as a module level subsystem.
The module is designed to work within ATM, SONET, SDH, and
wireless systems where synchronization is vital.
The SY01-S3F is an excellent OCXO based synchronization
solution for Stratum 3 applications with an additional +/-4.6PPM
free-run TCXO.
•
FEATURES
A Hardware/Software synchronization solution for timing, jitter and wander concerns in a single module.
Complies with ITU-T Recommendations G.813 and ETSI-ETS 300 462-4 and Bellcore GR-1244-CORE for Stratum
3 applications.
Supports four modes of operation: Locked to Reference 1, Locked to Reference 2, Holdover and Free-run.
Accepts reference inputs from two independent sources from 8 kHz to 77.76 MHz.
Provides two outputs up to 77.76 MHz.
Provides a secondary free-run output within +/-4.6PPM
Loop filtering utilizing application specific software in the digital signal processor (DSP).
Continuously monitors and evaluate input reference signals.
Creates a history buffer for Holdover mode operation.
Alarm and status signal.
Host interface and JTAG port.
Small dimensions of 1.80X1.80X 0.65 inch (open pkg)
•
APPLICATION
The SY01-S3F performs clock regeneration as a Synchronous Equipment Clock (SEC), or STRATUM 3 in ATM, SDH,
PDH, and SONET networks. It is designed for manufacturers of network equipment, especially Access Switches, Core
Switches, Cross Connects, Digital Multiplexers-Exchangers, and SDH/SONET equipment. The unit is also suitable for
PCS, WLL, and Wireless Base Stations. Wherever a Timing unit with high performance specifications is required, the
SY01-S3F can be integrated into the network system and provide all necessary frequencies and interfaces. The input
stage can receive two different input reference signals at various rates from 4 kHz to 77.76 MHz. An optional
application can be achieved by integrating the SY01-S3F with a low cost GPS receiver and locking it to the GPS 1
pps output signal.
RALTRON ELECTRONICS CORP. § 10651 N.W.19th St § Florida 33172 § U.S.A.
Tel: 305 593-6033 § Fax: 305-594-3973 § e-mail: [email protected] § Internet: http:/www.raltron.com
SYNCHRONOUS EQUIPMENT
OCXO BASED STRATUM 3 CLOCK UNIT WITH A 2 ND FREE-RUN
CLOCK OUTPUT – SY01-S3F
SCI
J-TAG
Temp.
Sensor
DAC
1
DSP
OCXO
CPLD
EX REF1
EX REF2
MUX
PD1
FLASH
RAM
TCXO
÷÷ N
CNT1
CNT2
CONTROL
LOGIC
ALARM OUT
PLL UNLOCK
OUT
HOLDOVER
REF 1
REF 2
PD2
OUTPUT
FREQUENCY
CONVERTERS
OPT OUT
FREE RUN
Figure 1. - The functional block diagram of SY01-S3F
•
DESCRIPTION
The SY01-S3F synchronization module is a Digital PLL (DPLL), which utilizes application specific software in the
digital signal processor (DSP). The DSP is complemented by fast hardware logic (CPLD) where all multiplexers,
counters, dividers, phase detectors, output frequency converters and other control logic circuits are completely
implemented. The functional block diagram with maximum configuration is shown in figure 1. Depending on the
application, the user can specify an appropriate configuration to fit their system requirements. The basic configuration
utilizes one DPLL with an OCXO as on-board oscillator, shown in figure 1 as the shaded boxes. The OCXO is driven
by a digital-to-analog converter (DAC1) and provides the accurate and stable signal under all conditions. The output
frequency converters scale the output frequency from the oscillator. For other configurations, please contact Raltron.
ü The module operates in the following four timing modes:
Free-run
In this mode the unit is unlocked to either of the inputs. The accuracy of the output frequencies in this mode is
±4.6ppm. Free-run mode is typically used when a master clock source is required, not valid history of data for the
Holdover mode, or immediately following system power-up before network synchronization is achieved. In the Free-run
Mode, the SY01-S3F provides timing and synchronization signals that are based on the accuracy of on-board
oscillators only, and are not synchronized to the reference signals.
Holdover
In this mode the module has lost its reference inputs and is utilizing stored timing data, called history, to control the
output frequency. Holdover Mode is typically used while network synchronization is temporarily disrupted. In Holdover
Mode, the SY01-S3F provides timing, based on data from the history buffer, while unlocked to an external reference
signal. The history data is determined while the device is locked to an external reference signal. The stability of the
output signal in holdover mode depends primarily on the stability of on-board oscillator and environment effects where
RALTRON ELECTRONICS CORP. § 10651 N.W.19th St § Florida 33172 § U.S.A.
Tel: 305 593-6033 § Fax: 305-594-3973 § e-mail: [email protected] § Internet: http:/www.raltron.com
SYNCHRONOUS EQUIPMENT
OCXO BASED STRATUM 3 CLOCK UNIT WITH A 2 ND FREE-RUN
CLOCK OUTPUT – SY01-S3F
the clock is mounted. The SY01-S3F uses an OCXO as an on-board oscillator but other types of oscillators are
available.
Locked to Ref.1
In this mode the output of the module is phase locked to input reference 1.
Locked to Ref.2
In this mode the output of the module is phase locked to input reference 2.
The REF1 or REF2 Modes are typically used when a slave clock source is synchronized to the network. In these
modes, the SY01-S3F provides timing signals, which are synchronized, to one of two references inputs (REF1 or
REF2). The input reference signals may have a variety of nominal frequencies, which is typically specified by the end
user. When the modes are selected the unit goes through a reference evaluation, and then a frequency acquisition,
and finally to phase locking.
•
Input References
The SY01-S3F module accepts two input references EX REF1 and EX REF2. End users can specify the frequencies
within a range of 8 kHz to 77.76 MHz. The input reference signals are HCMOS/TTL levels with timing characteristic in
according to Bellcore GR-1244-core 3.2.1.R3-1 or equivalent standards. Please note that the end user must specify
the two input frequencies at the time of order.
•
Output Signals
The SY0001D module provides two output signals OUT and OPT OUT. The first output (OUT) is synchronized and is
generated by the internal Stratum 3 OCXO oscillator and scaled by the output frequency converters. The second
output (OPT OUT) is not synchronized and comes from free-running +/-20PPM overall stability TCXO (SMC level). The
performance of the module significantly depends on the internal oscillators and special care was taken to define its
specifications. The frequency of the oscillator is specified according to the network application where the SY0001D will
be used.
•
The SY01 Operation mode
By changing the control inputs the user can change the state of the SY01 according to the state diagram. The
SY01 offers two ways to manage state machine:
J1 jumper
Open
Closed
State diagram control
Manual
Automatic
The behavior of the Manual and Automatic controls are shown on the figures 2 and 3 with an explanation for each
transition. In the Automatic control the SY01 can be automatically switched to the reference (if available)
regardless of status of the control inputs. In Manual control the unit waits for control inputs to be changed. In both
modes the unit will go to the REFERENCE EVALUATION if the previously lost reference is required.
•
Control
Two controls are available for the user to control the operation of the SY01. The two external inputs CNT1 and CNT2
provide this feature. Below, the truth table shows behavior of the SY01 module according to the control inputs states.
RALTRON ELECTRONICS CORP. § 10651 N.W.19th St § Florida 33172 § U.S.A.
Tel: 305 593-6033 § Fax: 305-594-3973 § e-mail: [email protected] § Internet: http:/www.raltron.com
SYNCHRONOUS EQUIPMENT
OCXO BASED STRATUM 3 CLOCK UNIT WITH A 2 ND FREE-RUN
CLOCK OUTPUT – SY01-S3F
CNT2
0
0
1
1
•
CNT1
0
1
0
1
MODE OF OPERATION
Free-run
Locked to REF1
Locked to REF2
Holdover
SPECIFICATIONS
General
Specifications
Mechanical
Input Signals
Power Supply
Warm Up Current Supply
Steady State Current Supply
Operating Temperature
Storage Temperature
Humidity
Internal Oscillators
Number of Inputs
Input reference frequency
Signal Level
Time Reference characteristics
Number of Outputs
Output 1
Output 2
Signal Level
Output Signal
Signal Quality
Performance
2” (D) x 2” (W) x 0.75” (H)
1.85” (D) x 1.85” (W) x 0.7” (H)
1.8” (D) x 1.8” (W) x 0.65” (H)
5VDC
900mA max
400mA max.
-20°C to 70°C
-40° to 85°C
5% to 95% non-condensing
OCXO
2
8kHz to 77.76MHz
HCMOS/TTL Compatible
Other ranges available on request
User selectable
Bellcore: GR-1244-core 3.2.1.R3-1
2
8kHz to 77.76MHz
8kHz to 77.76MHz
LVCMOS/HCMOS
Jitter Tolerance
Phase Transient Tolerance
Wander Generation
Wander Tolerance
Jitter Generation and Transfer
Wander Transfer
Frequency Output
Performance
Hermetically Sealed Metal box
Metal Box
Module on PCB
Regulated
User define (Startum 3 Level)
User define (Free run SMC clock)
Depend of the frequency output
Bellcore: GR-1244-core 4.2
ITU-T: G.813
Bellcore: GR-1244-core 4.4
Bellcore: GR-1244-core 5.3
ITU-T: G.812
Bellcore: GR-1244-core 4.3
ITU-T: G.812
Bellcore: GR-1244-core 5.5
ITU-T: G.812
Bellcore: GR-1244-core 5.4
ITU-T: G.812
GR-1244-core 5.1
ITU-T: G.812
Free run accuracy
±4.6ppm
Holdover frequency stability
±3.7x10-7 for 24hours
Initial Offset
±50x10-9
Bellcore: GR-1244-core 5.2
ITU-T: G.812
Temperature
±0.28x10-6
±1.0x10-6
Over operating temperature range
Drift
±40x10-9
DPLL bandwidth
Lock Time
Lock accuracy
0.1Hz
<30sec
±1x10-11
Bellcore: GR-1244-core 5.2
ITU-T: G.812
Or adjustable
GR-1244-core 3.7
RALTRON ELECTRONICS CORP. § 10651 N.W.19th St § Florida 33172 § U.S.A.
Tel: 305 593-6033 § Fax: 305-594-3973 § e-mail: [email protected] § Internet: http:/www.raltron.com
SYNCHRONOUS EQUIPMENT
OCXO BASED STRATUM 3 CLOCK UNIT WITH A 2 ND FREE-RUN
CLOCK OUTPUT – SY01-S3F
•
PIN ASSIGNMENT
On the picture below it is shown the pin-out for the SY01-S3F. The design is done in such a way that is can support
basically any other pin-out without changes in the hardware. For other pin-out requirement please contact the Raltron.
+5V
18
1
HOLDOVER
EX REF1
17
2
REF 1
GND
16
3
REF2
EX REF 2
15
4
FREERUN
GND
14
5
OPT OUT
13
6
GND
12
7
OUT
11
8
GND
10
9
GND
ALARM OUT
CNT 1
CNT 2
PLL UNLOCK
Figure 4 – Bottom view
Pin #
1
2
3
4
6
7
8
9
5,10,12,14,16
18
11
13
17
15
Name
HOLDOVER
REF 1
REF 2
FREERUN
Description
Holdover Signal -> the output is high when the unit is in holdover mode
Reference 1 Signal -> the output is high when the unit is using the reference 1
Reference 2 Signal -> the output is high when the unit is using the reference 2
Free-run Signal -> the output is high when the unit is in the free run mode
Alarm signal -> the output is high when there is an alarm in the module, alarm
ALARM OUT
condition is during free-run mode, holdover mode,
CNT 1
Control Input 1 -> the external input for selecting mode of the unit – see table.
CNT 2
Control Input 2 -> the external input for selecting mode of the unit – see table.
PLL Unlocked Signal -> the output is high when the unit is not locked to any of the
PLL UNLOCK
references
GND
Ground
+5V
Positive Voltage Supply
Synchronized Output -> the output of the synchronized signal, for frequency
OUT
range see table below.
Optional Output -> the secondary output of the synchronized signal, for frequency
OPT OUT
range see table below.
EX REF 1
External Reference 1 Input -> the input signal from reference 1
EX REF 2
External Reference 2 Input -> the input signal from reference 2
For other pin-out configurations contact the factory!
RALTRON ELECTRONICS CORP. § 10651 N.W.19th St § Florida 33172 § U.S.A.
Tel: 305 593-6033 § Fax: 305-594-3973 § e-mail: [email protected] § Internet: http:/www.raltron.com
SYNCHRONOUS EQUIPMENT
OCXO BASED STRATUM 3 CLOCK UNIT WITH A 2 ND FREE-RUN
CLOCK OUTPUT – SY01-S3F
•
MECHANICAL DIMENSIONS
Hermetically Sealed option
PCB option
•
Order Information
Please contact Factory for assignined P/N