SYNCHRONOUS EQUIPMENT MULTI OUTPUT HIGH FREQUENCY HITLESS SWITCHING - SY05-HF SY05-HF Date: May 20, 2002 • INTRODUCTION The SY05-HF is a high frequency clock that has been designed to be use at high speed Line Interface Cards in telecommunication products mainly related to STN-n or OC-n. • FEATURES √ A high frequency clock intended to be used at line cards for OC3 and OC12 (STM3 and STM12). √ Along with SY0001 or SY0010 provides complete timing solution. √ Provides very low jitter output signal. √ Performs hitless switching between two reference signals. √ Supports four timing modes: (1) Free-run, (2) Locked to Reference 1 (3) Locked to Reference 2, and (4) Loop back timing. √ Accepts reference inputs from two clock sources – 8KHz~77.76MHz √ Provides up to 4 LVPECL outputs and two LVCMOS outputs up to 777.6 MHz. (or alternatively 5 LVPECL outputs) √ Manual or Automatic selection between operating modes. √ Alarm and status signals. √ Complies with ITU-T Recommendations G.813, ETSI-ETS 300 462-4 and Bellcore GR-1244-CORE for Stratum 3 and 3E applications. √ Small dimensions of 1.80 x 1.80 x 0.429 inch. (Without Metal Cover) • APPLICATION The SY05-HF high frequency clock can be used in ATM, SDH, PDH, and SONET networks devices. It is designed for manufacturers of network equipment, especially Access Switches, Core Switches, Cross Connects, Digital MultiplexersExchangers, and SDH/SONET equipment. The SY05-HF is a timing solution for Line Interface Cards. th RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com SYNCHRONOUS EQUIPMENT MULTI OUTPUT HIGH FREQUENCY HITLESS SWITCHING - SY05-HF STATUS STATUS SIGNALS SIGNALS CU#1 CU#2 OUT 2 CMOS EX REF1 EX REF2 TLB REF AUTO/MAN REV/NONREV MUX, COUNTERS & CONTROL LOGIC CNT1 CNT2 PLL (PD+ LF) VCXO ALARM & STATUS ÷ OUT 1 PECL OUT 3,4 & 5 PECL Figure 1. - The functional block diagram of SY05-HF • DESCRIPTION The SY05-HF synchronization module is a high frequency PLL that performs hitless switching plus additional features necessary for timing at high-speed Line Interface Cards. The functional block diagram is shown in figure 1. The SY05-HF receives two reference signals, usually 19.44MHz and using PLL synthesizer generates a high frequency signal necessary for transceivers or framers. The PLL that is complemented by high-speed logic that provide processing, switching between the timing modes, alarm and status messages and etc. A high quality VCXO provides very low jitter at the output. The additional outputs are provided using a divider. The module supports two operating modes: AUTO mode is the mode where all switching are done automatically and MANUAL mode is where unit will switch according to the two external control pins CON1 and CON2. CON1 0 1 0 1 CON2 0 0 1 1 Operational mode Free-run (Unlocked) Locked to EX REF 1 Locked to EX REF 2 Locked to TLB REF The module operates in the following four timing modes: 1) Free-run, 2) Locked to EX REF1, 3) Locked to EX REF2 and 4) Locked to TBL REF. Free-run it a mode the unit is unlocked to either of the inputs. The accuracy of the output frequencies in this mode is equal to the accuracy of free running VCXO. Locked to EX REF 1 is the mode where the output of the module is phase locked to input reference 1. Locked to EX REF 2 is the mode where the output of the module is phase locked to input reference 2, Locked to TBL REF is the mode where is the output of the module is phase locked to the signal used in Time Loop-back operation. th RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com SYNCHRONOUS EQUIPMENT MULTI OUTPUT HIGH FREQUENCY HITLESS SWITCHING - SY05-HF • SPECIFICATIONS General Specifications Input Signals Output Signal Mechanical Power Supply Current Supply Operating Temperature Humidity Internal Oscillators Number of Inputs Input reference frequency Signal Level Time Reference characteristics Number of Outputs Output 1 Signal type Duty Cycle @ Output 1 Output 2 HCMOS 3.3V / 5V I/O tolerant Duty Cycle @ Output 2 Output 3 Signal type Duty Cycle @ Output 3 Output 4 Signal type Duty Cycle @ Output 4 Output 5 Duty Cycle @ Output 5 Signal Type 50/50% ±5% Out 1 Divide by 2 Low Voltage differential PECL 50/50% ±5% Out 1 Divid by 4 Low Voltage differential PECL 50/50% ±5% Out 1 divid by 8 Low Voltage differential PECL 50/50% ±5% Buffered Input/Synch Out 1 (Complimentary) HCMOS 3.3V / 5V I/O tolerant 50/50% ±5% Signal type Duty Cycle @ Output 6 Frequency Output Performance Stability Metal Box Module on PCB As output of SY0001/SY0010 6/5 51.84MHz~777.600MHz Low Voltage differential PECL 50/50% ±5% Buffered Input/Synch Out 1 Signal type Output 6 Signal Quality Performance 1.82” (D) x 1.82” (W) x 0.518” (H) 1.8” (D) x 1.8” (W) x 0.429” (H) +3.3VDC 200mA max -40°C to 80°C 5% to 95% non-condensing VCXO or SAW 2 8KHz~77.76MHz HCMOS 3.3V / 5V I/O tolerant . Low Voltage differential PECL (in cases of Synch Out 1) Low Voltage differential PECL (in cases of Synch Out 1 - Complimentary) Jitter Tolerance Bellcore: GR-1244-R4-4, ITU-T: G.812 Phase Transient Tolerance Jitter Generation and Transfer Bellcore: GR-1244-R4-7 Bellcore: GR-1244-R5-7, ITU-T: G.812 Pull-In Range MTIE TDEV Jitter @ OUT 1 Phase Transient MTIE Mask Free run ±50ppm Bellcore: GR-1244-R5-5, ITU-T: G.812 Bellcore: GR-1244-R5-4, ITU-T: G.812 Within the BW 10kHz to 20MHz GR1244 R5-14 Over operating temperature range <1ps RMS ±50ppm th RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com SYNCHRONOUS EQUIPMENT MULTI OUTPUT HIGH FREQUENCY HITLESS SWITCHING - SY05-HF • PIN ASSIGNMENT On the picture below it is shown the pin-out for the SY05-HF. For other pin-out requirement please contact the Raltron. GND 34 1 VCC TLB OK 33 2 REF1 FR TLB REF 32 3 REF2 FR TLB REF 31 4 REF 1 UL GND 30 5 OUT 1 29 6 OUT 1 REF 2 UL 28 7 ALARM EX REF 2 27 8 OUT 2 EX REF 1 REF 1 AL 26 9 OUT 6 REF 2 AL 25 10 GND GND 24 11 OUT 3 OUT 3 RV/NRV 23 12 REF 1 HL 22 13 REF 2 HL 21 14 AUTO/MA 20 15 CNT 1 19 16 CNT 2 18 17 OUT 4 OUT 4 OUT 5 OUT 5 GND Figure 3 – Bottom view th RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com SYNCHRONOUS EQUIPMENT MULTI OUTPUT HIGH FREQUENCY HITLESS SWITCHING - SY05-HF Pin # Name 1 +Vcc 2 REF1 FR 3 REF2 FR 4 5 6 GND OUT 1 OUT 1 7 ALARM Signal Technology Description Positive Voltage Supply Reference 1 Freerun Input -> the signal High (“1” logic) FREERUN comes from Clock Unit 1 Reference 2 Freerun Input -> the signal High (“1” logic) FREERUN comes from Clock Unit 2 Ground Synchronized Output 1 -> the output of the synchronized signal. Synchronized Complementary Output 1 -> the output of the synchronized signal. Alarm signal out -> the output is high when the module is unlocked (“1” logic) Buffered reference or synchronized signal Output 2 -> 8 OUT 2 a buffered external reference Signal (LVCMOS) or a buffered synchronized local oscillator signal. (LVPECL) Buffered reference or synchronized complimentary signal Output 6 -> 9 OUT 6 10 11 12 13 14 15 16 17 GND OUT 3 OUT 3 OUT 4 OUT 4 OUT 5 OUT 5 GND 18 CNT 2 19 CNT 1 20 AUTO/MAN 21 REF2 HL 22 REF1 HL 23 RV/NRV 24 GND 25 REF2 AL 26 REF1 AL 27 EX REF 2 28 REF2 UL 29 EX REF 1 30 REF1 UL 31 32 TLB REF TLB REF 33 TLB OK 34 GND a buffered external reference Signal (LVCMOS) or a buffered synchronized local oscillator signal. (LVPECL- complimentary). Ground Divider Output 3 -> the output of the synchronized signal divided by 2; Complementary Divider Output 3 -> the output of the synchronized signal divided by 2 Divider Output 4 -> the output of the synchronized signal divided by 4. Complementary Divider Output 4 -> the output of the synchronized signal divided by 4. – Divider Output 5 -> the output of the synchronized signal divided by 8; Complementary Divider Output 5 -> the output of the synchronized signal divided by 8; Ground Control Input 2 -> the external input for selecting mode of the unit – see table. DC Min ----- DC 0 VL Typ ----- ----LV/PECL LV/PECL DC ----Vcc-1.680 Vcc-1.680 0 0.25 ** (0.15) 0.25 ** (0.15) ----Vcc-1.620 Vcc-1.620 0.25 (0.15) HCMOS (3.3 Tolerable) 0 ----- 0.5** (0.3) LV/PECL Vcc-1.680 DC 0 Vcc-1.620 HCMOS (3.3 Tolerable) 0 ----- 0.5** (0.3) LV/PECL Vcc-1.180 Vcc-1.135 ----LV/PECL LV/PECL LV/PECL LV/PECL LV/PECL LV/PECL ----DC ----Vcc-1.680 Vcc-1.680 Vcc-1.680 Vcc-1.680 Vcc-1.680 Vcc-1.680 ----0 ----Vcc-1.620 Vcc-1.620 Vcc-1.620 Vcc-1.620 Vcc-1.620 Vcc-1.620 ----0.25 ** (0.15) 0.25 ** (0.15) 0.25 ** (0.15) 0.25 ** (0.15) 0.25 ** (0.15) 0.25 ** (0.15) ----0 Control Input 1 -> the external input for selecting mode of the unit – see table. DC 0 Auto/Manual configuration input -> selection input for operating mode Man=”0” ; Auto = “1” Reference 2 Holdover Input -> the signal High (“1” logic) HOLDOVER comes from Clock Unit 2 Reference 1 Holdover Input -> the signal High (“1” logic) HOLDOVER comes from Clock Unit 1 Revert / Non revert input-> selection input for revert feature Revertive-“1” ; Non-Revertive = “0” Ground Reference 2 Alarm Input -> the signal High (“1” logic) ALARM OUT comes from Clock Unit 2 DC 0 DC 0 DC 0 DC 0 ----DC ----0 Reference 1 Alarm Input -> the signal High (“1” logic) ALARM OUT comes from Clock Unit 1 DC 0 HCMOS (3.3 Tolerable) DC 0 ----- 0 HCMOS (3.3 Tolerable) DC 0 0.25 ** (0.15) ----- External Reference 2 Input -> the input signal from reference 2 Reference 2 Unlocked Input -> the signal High (“1” logic) PLL UNLOCK comes from Clock Unit 2 External Reference 1 Input -> the input signal from reference 1 Reference 1 Unlocked Input -> the signal High (“1” logic) PLL UNLOCK comes from Clock Unit 1 Time Loop back Reference Input -> the input from time loopback Time Loop back Complementary Input -> the complementary input from time loopback Time Loop back OK (nput -> When high (“1” logic) the loop back reference is valid for use Ground LV/PECL LV/PECL DC ----- 0 Vcc-1.680 Vcc-1.680 0 ----- 0 0.25 ** (0.15) Vcc-1.620 Vcc-1.620 0.25 ** (0.15) ----- Max ----- Min 4.75** (3.135) 0.5** 4.5** (0.3) (2.97) 0.5** 4.5** (0.3) (2.97) --------Vcc-1.56 Vcc-1.085 Vcc-1.56 Vcc-1.085 0.5 4.5 (0.3) (2.97) 4.5** (2.97) VH/ DC Voltage Typ 5.0** (3.3) 5.0** (3.3) 5.0** (3.3) -----Vcc-1.025 Vcc-1.025 5.0 (3.3) ---- Vcc-1.56 Vcc-1.085 4.5** Vcc0.975 ---Vcc-1.56 Vcc-1.56 Vcc-1.56 Vcc-1.56 Vcc-1.56 Vcc-1.56 ---0.5** (0.3) 0.5** (0.3) 0.5** (0.3) 0.5** (0.3) 0.5** (0.3) 0.5** (0.3) ---0.25 ** (0.15) 0.25 ** (0.15) 0.5** (0.3) 0.5** (0.3) 0.5** (0.3) 0.5** (0.3) Vcc-1.56 Vcc-1.56 0.5** (0.3) ---- ---- Vcc-1.085 Vcc-1.025 -----Vcc-1.085 Vcc-1.085 Vcc-1.085 Vcc-1.085 Vcc-1.085 Vcc-1.085 -----4.5** (2.97) 4.5** (2.97) 4.5** (2.97) 4.5** (2.97) 4.5** (2.97) 4.5** (2.97) -----0.5** (0.3) -----Vcc-1.025 Vcc-1.025 Vcc-1.025 Vcc-1.025 Vcc-1.025 Vcc-1.025 -----5.0** (3.3) 5.0** (3.3) 5.0** (3.3) 5.0** (3.3) 5.0** (3.3) 5.0** (3.3) -----4.5** (2.97) 0.5** (0.3) 4.5** (2.97) 4.5** (2.97) 4.5** (2.97) 4.5** (2.97) 4.5** (2.97) Vcc-1.085 Vcc-1.085 4.5** (2.97) ------ For other pin-out configurations contact the factory! ** Indicates corresponding values to Vcc=5V • ORDERING INFORMATION Please contact factory with input/output options for P/N assiagnment. th Vcc-1.025 (2.97) RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com Max 5.25** (3.465) 5.25** (3.465) 5.25** (3.465) -----Vcc-0.885 Vcc-0.885 5.25 (3.465) ---- Vcc-0.885 ---Vcc0.880 -----Vcc-0.885 Vcc-0.885 Vcc-0.885 Vcc-0.885 Vcc-0.885 Vcc-0.885 -----5.25** (3.465) 5.25** (3.465) 5.25** (3.465) 5.25** (3.465) 5.25** (3.465) 5.25** (3.465) -----5.0** (3.3) 5.0** (3.3) ---- ---- 5.0** (3.3) ---- 5.25** (3.465) ---- 5.0** (3.3) Vcc-1.025 Vcc-1.025 5.0** (3.3) ------ 5.25** (3.465) Vcc-0.885 Vcc-0.885 5.25** (3.465) ------ SYNCHRONOUS EQUIPMENT MULTI OUTPUT HIGH FREQUENCY HITLESS SWITCHING - SY05-HF • MECHANICAL DIMENSIONS Figure 4 – The mechanical dimensions. Figure 4 shows the mechanical dimension of the SY05-HF-HF module. The module can be supplied in two different types of packaging: " Metal box " Module without packaging The dimensions shown on the picture are valid for first and second type of packaging, the actual dimensions for the first type are 1.82 x 1.82 x 0.518” keeping the pin-out dimensions the same for all of three. The label on the module shows part number, factory name, week and year of production. th RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com