SY10 - Raltron Electronics Corporation

SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
SY10
Date: August 30, 2002
•
INTRODUCTION
The SY10 - an accurate time and frequency source
that had been designed as a subsystem level module.
The module is designed to work within ATM, SONET,
SDH, and wireless systems where synchronization is
vital. The SY10 is an excellent synchronization
solution for timing, with jitter and wander compliance
per the specified within ITU-T Recommendations
G.812/G.813 and Bellcore GR-1244-CORE. The
SY10 is an enhanced version of SY01 and is
designed for Stratum 3 and Stratum 3E, but also
holds certain features that can make it useful for
SONET Minimum Clock (SMC) or other kinds of
system clocks.
•
FEATURES
√
A synchronization solution for timing, jitter and wander concerns in a single module.
√
Complies with ITU-T Recommendations G.812/813 and Bellcore GR-1244-CORE for Stratum 3 and Stratum 3E
applications.
√
Supports modes of operation: Locked, Holdover and Free-run.
√
Accepts reference inputs from up to six independent sources from 8KHz to 77.76MHz
√
Provides up to 3 output from 8KHz to 77.76MHz (Two user select and one fixed at 8KHz)
√
Loop filtering utilizing specific software application in the digital signal processor (DSP).
√
Continuously monitors and evaluate input reference signals.
√
Phase build-out for output clock.
√
Creates a history buffer for Holdover mode operation.
√
Alarm and status signals and messages.
√
Host interface SPI for configuring and remote monitoring.
√
Supports Master/Slave configuration of two SY10 with minimum phase error between two clocks.
√
Provides “hit-less” switching during switching between the clocks.
√
Pin compatible with 18 pins SY01 module.
√
Small dimensions of 1.82 x 1.82 x 0.7 inch. (0.60 inch with no mechanical cover)
•
APPLICATION
The SY10, a Synchronous Equipment Clock (SEC), fulfills clock regeneration function for STRATUM 3 and 3E
equipment for: ATM, SDH, PDH, and SONET networks. It was designed for network system manufacturers such as:
Access Switches, Core Switches, Cross Connects, Digital Multiplexers-Exchangers, and SDH/SONET equipment.
The unit is also suitable for PCS, WLL, and Wireless Base Stations. Wherever a Timing unit with high performance
specifications is required, the SY10 can be embedded within the network system and provide all necessary
frequencies and interfaces.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
1
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
Alarms and Statuses
Ex.Ref.1
Ex.Ref.2
Ex.Ref.3
Ex.Ref.4
Ex.Ref.5
Ex.Ref.6
OCXO
MUX,
FPD,
Counters
&
Logic
Control Inputs
OUT 3
DSP
(RAM,
FLASH)
SPI
DDS
Output
PLL
Synthesizer
OUT 2
OUT 1
JTAG
Figure 1. - The functional block diagram of SY10.
•
DESCRIPTION
The SY10 synchronization module is a Digital PLL (DPLL), which utilizes application specific software in the digital
signal processor (DSP). The DSP is complemented by fast hardware logic (FPGA) where all multiplexers, counters,
dividers, phase detectors, output frequency converters and other control logic circuits are completely implemented.
The functional block diagram with maximum configuration is shown in figure 1. The module has three phase lock
loop – primary PLL, secondary and utility PLL. The primary PLL utilizes a Direct Digital Synthesis (DDS) technique
combined with a high stability OCXO in order to provide an accurate and fast DPLL response and eliminates the
requirement for an OCXO with high pullability. The primary loop is a low bandwidth loop that filters a major part of
the wander and the jitter at the input. The output of the primary PLL is connected to the secondary PLL synthesizer
that is also a DPLL but with a wider loop bandwidth. The secondary PLL loop has also another input that comes
from the SEC IN pin. Depending on the master–slave mode, the secondary loop utilizes either one of the inputs.
The output of secondary PLL is connected to the utility PLL that is an analog phase lock loop.
-
The outputs of secondary and utility PLL provide three independent output signals.
The SPI serial communication interface provides a flow of messages between the module and a host
processor.
The JTAG interface provides an easy access for future software upgrade re-programming without
removing the module from the system.
The SY10 software provides several features such as:
-
switching between the references inputs on the basis of monitoring and estimation of the input signals
and internal state diagram;
real time calculation of the filtering algorithm for jitter and wander in according to the approved
standards;
alarm, status and messaging functions using output pins and serial communication port.
For other configurations, please contact Raltron.
" The module operates in the following three timing modes:
Free-run
In this mode, the unit is unlocked to either of the inputs. The accuracy of the output frequencies in this mode is
±4.6ppm. Free-run mode is typically used when a master clock source is required, not valid history of data for the
Holdover mode, or immediately following system power-up before network synchronization is achieved. In the Freerun Mode, the SY10 provides timing and synchronization signals that are based on the accuracy of on-board
oscillators only, and are not synchronized to the reference signals.
Holdover
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
2
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
In this mode, the module has lost its reference inputs and is utilizing stored timing data, called history, to control the
output frequency. Holdover Mode is typically used while the network synchronization is temporarily disrupted. In
Holdover Mode, the SY10 provides timing, based on data from the history buffer, while unlocked to an external
reference signal. The history data is determined while the device is locked to an external reference signal. The
stability of the output signal in holdover mode depends primarily on the stability of on-board oscillator and
environment effects where the clock is mounted. The SY10 uses an OCXO as an on-board oscillator but other types
of oscillators are available.
Locked to Reference
In this mode, the output of the module is phase locked to any of input references. The output frequency tracks the
selected input reference. The “Locked to Reference Modes” is typically used when a slave clock source is
synchronized to the network. In these modes, the SY10 provides timing signals, which are synchronized, to one of
six references inputs (REF1 to REF6). The input reference signals may have a variety of nominal frequencies, which
are typically specified by the end user. When the modes are selected the unit goes through a reference evaluation,
and then a frequency acquisition, and finally to phase locking.
Local Reference Oscillator
Depending on the type of clock, a local reference oscillator is selected. For example: for a Stratum 3E type of clock,
the local oscillator is a high stability SC-cut OCXO that meets this standard requirements for frequency drift and jitter
noise.
Input References
The SY10 module accepts six input references EX REF1 to EX REF6. End users can specify the frequencies within
a range of 8 kHz to 77.76 MHz. The input reference signals are HCMOS/TTL levels with timing characteristic in
accordance with Bellcore GR-1244-core 3.2.1.R3-1 or equivalent standards. Please note that the end user must
specify the input frequencies at the time of order.
Monitoring and Evaluation of the Input References
Using an advanced algorithm the input references are continuously monitored and evaluated by the module. There
are three techniques used in the algorithm for each of reference, presence of the reference, frequency offset during
the time when the unit is phase locked to the reference, and frequency offset when the unit in not phase locked to
the reference. The SY10 rejects all reference signals whose frequency accuracy is offset by more than ±13 PPM. At
any given event that requires a switching in the operation mode, the timing module unit performs a reference
evaluation test of the new target reference. Since such evaluation is a continuous process, the switching takes very
short time (typically less then a second). Providing a successful evaluation, the unit switches to frequency and
phase locking mode. On the other hand, if the reference was not qualified the unit switches to a holdover mode.
Filtering in the DPLL
The SY10 dynamically changes its loop bandwidth according to the status of the DPLL. In the primary PLL there are
five stages that the DPLL goes through before phase lock mode is achieved. The first stage is frequency acquisition
that takes place until the frequency becomes equal to the reference. The second stage is the phase acquisition
stage that takes place until a new phase reference is acquired. The other stages are tracking stages (1, 2 and 3)
(hint: the DPLL is locked and tracks the phase reference with a very low loop bandwidth). This method of three
tracking stages ensures minimum locking time and minimum phase jumps and shifts during acquisition or transition.
It also provides phase build-out during switching or rearrangement. The secondary PLL operates similarly to the
primary PLL with an exception of a wider bandwidth (hint: it has only three stages) – the first is frequency
acquisition, second is phase acquisition and third one is tracking mode. Please see detail in state diagram.
History Buffer for HOLDOVER mode
Frequency and timing data is continuously collected in the history buffer during the time when the unit is locked to
any of the input references. The history buffer is actually a circular buffer in memory that keeps valid data for
HOLDOVER mode during the last 90 seconds of operation. When the SY10 enters to HOLDOVER mode the data
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
3
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
from the buffer is validated and processed. The history buffer can be cleared by writing one to bit HLRST in CFG2
register.
Output Signals
The SY10 module provides three output signals OUT, OPT OUT1 and OPT OUT2. The outputs are generated by
the internal oscillators VCXO and scaled by the output frequency converters. Two VCXO oscillators can be used per
module providing two independent frequency types and the third one (OPT OUT2) is derived from one of them. The
performance of the module significantly depends on the output oscillator and special care is taken to define their
specifications. The used VCXO are high quality crystal oscillators with very low output jitter. The frequency of the
oscillator is specified according to the network application where the SY10 will be used. The frequency converters
divide signal from the oscillator to the specified frequencies.
Indications
The SY10 provides detailed monitoring and indication of operation of the unit. Two types of monitoring and status
indicating are provided:
-
Visual indication: Using ten on board color mounted LED’s that indicate the operating mode of the
SY10. The LED indicators are mainly placed for system troubleshooting, and testing.
-
Electronic indications: Using ten digital outputs that report status and alarms from the SY10. These
alarms are mainly used for communication between the module and network equipment.
The internal LED indicators are:
Signal
Holdover
REF1
REF2
REF3:.
REF4:
REF5
REF6
FREERUN
UNLOCK
ALARM
LED
super light red LED, ON when the module is in holdover mode.
green LED, ON when the module is locked to reference 1.
green LED, ON when the module is locked to reference 2.
green LED, ON when the module is locked to reference 3
green LED, ON when the module is locked to reference 4.
green LED, ON when the module is locked to reference 5.
green LED, ON when the module is locked to reference 6.
orange LED, ON when the unit is in free running mode.
red LED, ON when the module is not locked to the selected reference signal.
red LED, ON when there is an alarm in the module
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
4
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
Control
Several controls pins are available for the user to control the operation of the SY10 Primary PLL. The three external
inputs CNT1, CNT2 and CNT3 provide the feature to change the state of operation. Below, the truth table shows
behavior of the SY10 module according to the control inputs states.
CNT3
0
0
0
0
1
1
1
1
CNT2
0
0
1
1
0
0
1
1
CNT1
0
1
0
1
0
1
0
1
MODE OF OPERATION
Free-run
Locked to REF1
Locked to REF2
Holdover
Locked to REF3
Locked to REF4
Locked to REF5
Locked to REF6
To change the operation of Secondary PLL (Master-Slave) can be change using MS/FR control pin.
MS/FR†
MODE OF
OPERATION
1 (or open) Master (default)
0
Slave
†see explanation about MS/FR below.
The state of operation can be set and changed also using serial communication port, please see below.
The SY10 State Machine – Primary PLL
The state machine of SY10 module can be controlled using one of two interfaces:
1) three external control pins CNT1, CNT2 and CNT3.
2) setting bits (CON0, CON1, CON2 and CON3) in CFG1 register using serial peripheral interface (SPI).
After the reset the module is set to use three external control pins for control function but user can change it by
setting bit UI in register CFG1. By setting the UI bit to 1 the module ignores states of the control pins and use bits in
CFG1 register for state engine control. On the figure below is shown simplified stated diagram of SY10 module.
1
FREE RUN
2
4
5
3
6
REFERENCE
SWITCHING
14
7
8
9
10
11
12
FREQ. and PHASE
LOCKING
HOLDOVER
13
Figure 2 – The SY10 state diagram – Primary PLL.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
5
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
1) (FREERUN)
The path 1 runs until control signals (CNT1,2,3 pins or CON0,1,2,3 bits in CFG1 register) are set to zero or there is
no valid history available on the acquisition buffer for the holdover.
2) (FREERUN_ REFERENCE_SWITCHING)
The path 2 runs when there was any change at control signals.
3) (REFERENCE_SWITCHING_FREERUN)
The path 3 runs when the control signals were changed to zero – the free-run mode was selected.
4) (REFERENCE_SWITCHING)
The path 4 runs until appropriate reference was selected. If the unit is in Auto Switching mode (bit AUTOEN in
CFG2 register set to 1) the module will switch in the following conditions:
1) if a reference that was selected by control signals,
2) if the selected reference is not available it will switch based on Priority Table (registers PR1 – PR4).
3) if any of the references are not available it will go to holdover (path 8)
If the unit is in Manual Switching mode (bit AUTOEN in CFG2 register set to 0) the module will switch in following
conditions:
1) if a reference that was selected by control signals,
2) if the selected reference is not available it will go to holdover (path 8)
5) (FREQ&PHASE_LOCKING_FREERUN)
The path 5 runs when the control signals were changed to zero – the free-run mode was selected.
6) (HOLDOVER_FREERUN)
The path 6 runs when the control signasl were changed to zero – the free-run mode was selected or there is no
valid history available on the acquisition buffer for the holdover.
7) (REFERENCE_SWITCHING_FREQ&PHASE_LOCKING)
The path 7 runs when the reference switching was successfully finished – a reference was qualified and no changes
at control signals.
8) (REFERENCE_SWITCHING_HOLDOVER)
The path 8 runs if the following conditions:
1) if control signals were changed to one (0011) – the holdover mode was selected.
2) if the module is in Auto Switching mode (bit AUTOEN in CFG2 register set to 1) the module will switch
to the holdover if none of the reference are available.
3) if the module is in Manual Switching mode (bit AUTOEN in CFG2 register set to 0) and selected
reference was not qualified or reference was lost during process of evaluation.
9) (FREQ&PHASE_LOCKING_REFERENCE_SWITCHING)
The path 9 runs in the following conditions:
1) if another reference was selected changing control signals.
2) if the module is in Auto Switching mode (bit AUTOEN in CFG2 register set to 1) the module will switch
to the reference switching if at least one of the references is available and when the currently selected
reference is failing.
3) if the unit was set to operate in Revertive mode (bit REVEN in CFG2 register is set to 1) and previously
lost reference is back the module will switch to reuse the same reference.
10) (HOLDOVER_ REFERENCE_SWITCHING)
The path 10 runs in the following conditions:
1) current selected reference was reacquired or if the other reference was selected changing control
signals.
2) if the unit was set to operate in Revertive mode (bit REVEN in CFG2 register is set to 1) and previously
lost reference is back the module will switch to reuse the same reference.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
6
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
11) (FREQ&PHASE_LOCKING)
The path 11 runs until the frequency acquisition or the phase locking is in progress with no changes at control pins.
The module goes through a few intermediate states in order to accomplish phase tracking. There are three basic
intermediate steps that include frequency acquiring, phase acquisition and tracking. Tracking can have additional
steps depending of the bandwidth to be achieved.
12) (HOLDOVER)
The path 12 runs until the holdover mode is in progress with no changes at control signals.
13) (FREQ&PHASE_LOCKING_ HOLDOVER)
The path 13 runs in following conditions:
1) if the used reference was lost or was detected bad,
2) if the control signals were changed to one (0011) – the holdover mode was selected.
14) (FREERUN_HOLDOVER)
The path 14 runs only if the control signals were changed to one (0011) and valid history buffer for holdover
operation is available – the holdover mode was selected.
SY10 Master-Slave Operation – Secondary PLL
In systems where clock redundancy is required it is possible to connect two SY10 – such connection shown at the
figure below. The module has two pins dedicated for this feature – MS/FR and SEC IN. The MS/FR control input
selects if the module will operate as master (logic high) or slave in the system. The SEC IN is input for signal that
comes from another clock module. In the system always clock “one” operates as master and the second one as
slave clock. When operating as a slave the output of SY10 also tracks the master so it provides minimum phase
difference between the two clocks. This is very useful as it makes easier “hitless” switching of references. The
Master-Slave control can also be done using SPI communication setting the bit MS in register CFGREG1. Please
see more in Memory Mapped Registers section. The typical Master-Slave connection block diagram is show on
figure below.
OUT (Pin 10)
M/S
SY10
1
M/S
SEC IN (Pin 25)
SEC IN (Pin 25)
SY10
2
OUT (Pin 10)
Figure 3. - The Master – Slave connection of two SY10.
The state machine of SY10 Master –Slave operation module can be controlled using one of two interfaces:
3) one external control pin MS/FR.
4) setting MS bit in CFG1 register using serial peripheral interface (SPI).
After the reset the module is set to use the external control pin for control function but user can change it by setting
bit UI in register CFG1. By setting the UI bit to 1 the module ignores states of the control pins and use bits in CFG1
register for state engine control. On the figure below is shown simplified stated diagram of SY10 Master –Slave
operation.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
7
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
1
MASTER
2
3
4
SLAVE
Figure 4. - The SY10 Master – Slave state diagram
1. (MASTER)
The path 1 runs until control signals MS/FR† is set to 1 (or MS bit in CFG1 register is set to 0) or there is no
valid signal at SEC IN pin. No valid signal means either not present or not within frequency offset window.
2. (MASTER_SLAVE)
The path 2 runs when there was a change at MS/FR control signal from 1 to 0 (or in case of MS bit in
CFGREG1 from 0 to 1) and there is valid signal at SEC IN pin.
3. (SLAVE_MASTER)
The path 3 runs when there was a change at MS/FR control signal from 0 to 1 (or in case of MS bit in
CFGREG1 from 1 to 0) or there is no valid signal at SEC IN pin (signal disappeared).
4. (SLAVE)
The path 4 runs until control signal MS/FR is set to 0 (or MS bit in CFG1 register is set to 1) and there is valid
signal at SEC IN pin.
†see explanation below!
MS/FR shared pin input
Since the MS/FR control input pin shares the function special caution should be taken to drive it. The signal at
MS/FR signal is sampled and processed by internal software and decisions are made using following:
1) To change status of Secondary PLL from Master to Slave using MS/FR the user have to change from 1 to 0
and keep the pin logic low for period longer then 100ms not communicating through SPI. If within that period
of time MS/FR signal does not change level (0) and there is no clock signal at SCLK pin (no changing at
SCLK for SPI communication) the operation will be changed from Master to Slave.
No CLK signal
SCLK
Sampes
MS/FR
>100ms
Change to SLAVE
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
8
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
2) To maintain Slave mode while still communicating through SPI signal MS/FR should be set high prior SCLK
for no more then 100ms at any given time. Please see timing constrains for SPI communication.
CLK signal
SCLK
Sampes
MS/FR
100ms
No Change
3) To change status of Secondary PLL from Slave to Master the signal MS/FR should be set to high (1) for
period longer then 100ms not communicating through SPI.
No CLK signal
SCLK
Sampes
MS/FR
>100ms
Change to MASTER
4) To maintain Master mode while still communicating through SPI signal MS/FR should be set low during
SCLK for no more then 100ms at any given time. Please see timing constrains for SPI communication.
CLK signal
SCLK
Sampes
MS/FR
100ms
No Change
Changing mode of operation can be done easier using SPI communication interface – please see next paragraph.
For other configuration please contact Raltron Electronics Corp.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
9
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
•
SERIAL COMMUNICATION BUS – SPI
The module can be configured, controlled and monitored using an on board serial communication port – SPI
provided on the SY10. There are four pins available for this features SCLK, MS/FR, DIN and DOUT. The DIN and
DOUT are ports used to transfer command and data in and out of the module. The SCLK is input used to clock the
data transfer in and out of the module and MS/FR is shared pin that provides frame synch signal. The SY10
operates only as a slave device on SPI bus so the transfer of the data or command should be initiated by a microcontroller. The micro-controller can read or write to configuration registers and read only from status registers
mapped internally into the SY10. Optionally the interface can be implemented in SPI.
SCLK
CPU
SY10
DOUT
DIN
MS/FR
Figure 9. - The SPI serial communication
Communication Protocol for SPI
The interface is synchronous peripheral interface (SPI), the master must to provide clock signal and initiate the
communication cycles. There are read and write cycles and each communication cycle that consists of 16 clocks
(8+8 bits). Data is latched every rising edge of clock input from most significant bit. The maximal allowed frequency
for SCLK is 10MHz - tclk.
Write data cycle
The master sends to the module two bytes (2 x 8bits). First byte is always command byte. The second byte is the
data byte contains information to write.
Command byte data format:
7(MSB)
R/W
6
X
5
A5
4
A4
3
A3
2
A2
1
A1
0(LSB)
A0
1
D1
0(LSB)
D0
- A5…A0 - Module register address please see the table 1.
- R/W - Read (1) or Write (0) bit.
- X – not used.
Data byte format:
7(MSB)
D7
-
6
D6
5
D5
4
D4
3
D3
2
D2
D7…D0 – Content to be written to the register addressed by A5:A0
Read data cycle
The master sends to the module one-command byte and receives from module information byte (see 1.1 and 1.2).
Command byte data format:
7(MSB)
R/W
6
X
5
A5
4
A4
3
A3
2
A2
1
A1
0(LSB)
A0
- A5…A0 - Module register address please see the table 1.
- R/W - Read (1) or Write (0) bit.
Data byte format:
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
10
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
7(MSB)
D7
-
6
D6
5
D5
4
D4
3
D3
2
D2
1
D1
0(LSB)
D0
D7-D0 – Content to be read from the module addressed by A5:A0
SPI Flowchart
Entry point
YES
No of received
bytes > 0?
NO
NO
Received
Address Valid?
SPIStatus =
ADDRESSERROR
YES
Command
Read or
Write?
WRITE
YES
No of
received
bytes = 1?
NO
NO
No of received
bytes = 2?
YES
READ
READ
Fetch data from
MMR to send out
WRITE
NO
SPIStatus = OK
SPIStatus =
OVERFLOW
Wait for the
next byte
Command Read
or Write?
Reset all
Valid Data to
write in MMR?
YES
SPIStatus =
WRITEERROR
Write Data in
MMR
SPIStatus = OK
Figure 10. - The SPI flowchart.
Timing diagrams
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
11
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
Please see below the timing diagram for a write and read cycles. Please note that DOUT is not a tri-state output.
The minimum value for tclk is 100ns and time out tout is approximately 1sec. The SPI will latch data on input DIN and
set data on output DOUT on every rising edge of SCLK however operation mode can be changed operates on
request. Changes may include clock polarity, length of data etc. During the read cycle the master have to provide a
pause between two bytes of minimum 1ms (twait ≥ 1ms).
tclk
tout
SCLK
tds
DIN
DOUT
tdh
A4
A3
A2
A1
A0
D7
D6
D5
D4
D3
D2
D1
D0
tfh
tfs
MS/FR
Figure 11. - Write cycle SPI 8-bit
Parameter
tclk – CLK
tfs – Time to set FR prior CLK transition
tfh – Time to hold FR after CLK transition
tds–Time to set data prior CLK transition
tdh – Time to hold data after CLK transition
tclk
Min
100ns
tclk/2
tclk/2
10ns
1ns
Max
twait
SCLK
DIN
A4
A3
A2
A1
A0
DOUT
D7
D6
D5
D4
D3
D2
D1
D0
MS/FR
Figure 12. - Read cycle SPI 8-bit
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
12
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
Memory Mapped Registers
There are twenty-eight 8-bit registers accessible through the serial port: 12 registers to write and read data and 16
registers to only read data from module. See table 1 for memory map registers and their purpose.
Addr.
Read
Write
Name
Format
00H
01H
02H
03H
04H
05H
06H
07H
08H
09H
0AH
0BH
0CH
0DH
0EH
0FH
10H
11H
12H
13H
14H
15H
16H
17H
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
PR1
PR2
PR3
PR4
RFH1
RFH2
RFH3
RFH4
RFH5
RFH6
RFH7
RFH8
RST1
RST2
PSP1
PSP2
PMAX
PMIN
CFG1
CFG2
FA1
BW11
BW12
FB2
M
7
R23
R43
R63
x
S7
S7
S7
S7
S7
S7
x
x
S41
x
PS7
US3
S7
S7
UI
X
F7
P13
P33
F3
18H
19H
1AH
1BH
Y
Y
Y
Y
N
N
N
N
SST
CID
SID
HID
ST7
CID7
SID7
HID7
6
R22
R42
R62
x
S6
S6
S6
S6
S6
S6
x
x
S40
x
PS6
US2
S6
S6
X
X
F6
P12
P32
F2
ST6
CID6
SID6
HID6
Description
2
R12
R32
R52
x
S2
S2
S2
S2
S2
S2
x
x
S20
S60
PS2
SS2
S2
S2
CON2
H
F2
P02
P22
B2
1
R11
R31
R51
x
S1
S1
S1
S1
S1
S1
x
x
S11
S51
PS1
SS1
S1
S1
CON1
R
F1
P01
P21
B1
L
0
R10
R30
R50
x
S0
S0
S0
S0
S0
S0
x
x
S10
S50
PS0
SS0
S0
S0
CON0
A
F0
P00
P20
B0
ST5
ST4
ST3
ST2
CID5
CID4
CID3
CID2
SID5
SID4
SID3
SID2
HID5
HID4
HID3
HID2
Table 1. Memory map registers.
ST1
CID1
SID1
HID1
ST0
CID0
SID0
HID0
5
R21
R41
R61
x
S5
S5
S5
S5
S5
S5
x
x
S31
x
PS5
US1
S5
S5
X
P
F5
P11
P31
F1
4
R20
R40
R60
x
S4
S4
S4
S4
S4
S4
x
x
S30
x
PS4
US0
S4
S4
MS
F
F4
P10
P30
F0
3
R13
R33
R53
x
S3
S3
S3
S3
S3
S3
x
x
S21
S61
PS3
SS3
S3
S3
CON3
R
F3
P03
P23
B3
4-bit priority for references 1-2
4-bit priority for references 3-4
4-bit priority for references 5-6
Not used
Ref. 1 frequency shift in ppm
Ref. 2 frequency shift in ppm
Ref. 3 frequency shift in ppm
Ref. 4 frequency shift in ppm
Ref. 5 frequency shift in ppm
Ref. 6 frequency shift in ppm
Not used
Not used
References 1-4 status
References 5-6 status
Status of Primary PLL
Status of Secondary and Utility PLL
Maximum frequency pull in ppm
Minimum frequency pull in ppm
Configuration 1
Configuration 2
Frequency acquisition set for PLL1
Bandwidth 1 and 0 set for PLL1
Bandwidth 3 and 2 set for PLL1
Frequency acquisition (F) and
Bandwidth track (B) for PLL2
SPI status register
Customer ID register
Software ID register
Hardware ID register
Reference Priority Registers (PR1 to PR4) – address 00-03h
There are four registers PR1 – PR4 that specify priority during switching. Every reference has 4-bit priority so two
references are defined per register. The priority means that the module in the event of loosing reference will lock to
valid reference with higher priority available if bit AUTOEN of register CFG2 is set to one. The initial priority is set by
module but can be overridden by customer. The highest priority is 1111b and the lowest priority is 0001b. If priority
is set to zero (0000b) the reference will not be used in the module – the status will be “Reference present but not in
use”.
- R10-R13 – defines reference 1 priority
- R20-R23 – defines reference 2 priority
- R30-R33 – defines reference 3 priority
- R40-R43 – defines reference 4 priority
- R50-R53 – defines reference 5 priority
- R60-R63 – defines reference 6 priority
The default values are:
PR1:0x78h
PR2:0x56h
PR3:0x34h
PR4:0x12h
Frequency Shift Registers (RFH1-RFH8) - address 04-0Bh.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
13
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
The registers indicate how far the references out of nominal frequency in parts per million (ppm). The resolution is
0.5ppm. The range is ±63ppm. If the frequency above or below ±63ppm range, the +63 or -63 is shown respectively
and proper status indicated in Reference Status Registers. The format is 2-s compliment and for example if the
content of RFS3 register is 11000111 then the third reference is: -28.5ppm
7(MSB)
SIGN
6
25
5
24
4
23
3
22
2
21
1
20
0(LSB)
2-1
The default values are:
RFH1: 0xFFh
RFH2: 0xFFh
RFH3: 0xFFh
RFH4: 0XFFh
RFH5: 0xFFh
RFH6: 0xFFh
RFH7: 0xFFh
RFH8: 0xFFh
Reference Status Registers (RST1-RST2) - address 0C-0Dh
There are 2 reference status registers that hold information about status of references. Each reference has 2-bit
status or each register keep statuses for four references. The possible statuses are:
Binary number
00
01
10
11
-
Status
Not Present
Present
Not in use
Reference OK
Description
Reference not present or can not be evaluated
Reference present but out of frequency range
Reference present but not in use
Reference present and in the frequency range
S10-S11 – defines status of reference 1
S20-S21 – defines status of reference 2
S30-S21 – defines status of reference 3
S40-S41 – defines status of reference 4
S50-S51 – defines status of reference 5
S60-S61 – defines status of reference 6
The default values are:
RST1: 0x00h
RST2: 0x00h
PLL Status Registers (PSP1-PSP2) - address 0E-0Fh
Register PSP1 indicates status of Primary PLL. In the register the 4 least significant bits indicate status of the PLL
and the 4 most significant bits indicate reference in use in the loop. The possible statuses of Primary PLL are shown
in PSP1:
PS3-PS0
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
Status description
PLL not locked. This status represents major error.
Frequency Acquisition
Phase Acquisition
Tracking Bandwidth 0
Tracking Bandwidth 1 (SP1 only)
Tracking Bandwidth 2 (SP1 only)
Tracking Bandwidth 3 (SP1 only)
Phase Build-out
Holdover
Free run
The possible reference bits are:
PS7-PS4
x000
x001
Status description
No reference in use (module in Free run or Holdover)
Reference 1
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
14
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
x010
x011
x100
x101
x110
0xxx
1xxx
Reference 2
Reference 3
Reference 4
Reference 5
Reference 6
Holdover History Buffer Not Available
Holdover History Buffer Available
Register PSP2 indicates status of Secondary PLL. In the register the 4 least significant bits indicate status of the
Secondary PLL and the 4 most significant bits indicate status of the utility PLL if available.
SS3-SS0
0000
0001
0010
0011
0100
0101
0110
Status description
PLL not locked. This status represents major error.
Frequency Acquisition operating as a master clock
Phase Acquisition operating as a master clock
Tracking Bandwidth operating as a master clock
Frequency Acquisition operating as a slave clock
Phase Acquisition using operating as a slave clock
Tracking Bandwidth using operating as a slave clock
The possible utility PLL status bits.
US3-US0
0000
0001
Status description
Not locked
Locked
The default values are:
PSP1: 0x00h
PSP2: 0x00h
Frequency Pull Range Registers (PMAX and PMIN) - address 10-11h
These registers specify the window of pull-in range and reference acceptance frequency window. The PMAX
register specifies maximum frequency window that the module can be locked on and frequency beyond references
will be rejected. The PMIN registers frequency window within references will be accepted. The PMAX must be
greater then PMIN and both are positive numbers. The data format is unsigned binary 8-bit number, for example if
the content of PMAX register is 00011110 and PMIN 00011010 then the pull in range is: ±15ppm and reference
acceptance is ±13ppm:
7(MSB)
26
6
25
5
24
4
23
3
22
2
21
1
20
0(LSB)
2-1
The default values are:
PMAX: 0x1Eh
PMIN: 0x1Ah
Configuration Registers (CFG1 and CFG2) - address 12-13h
Register CFG1 used to set clock mode of operation. The user can select which interface will be used to change the
mode of operation by setting bit UI. If the UI bit in CFG1 register is set to 0 (default) the module will change the state
in according to three input pins CNT1, CNT2 and CNT3. If the If the UI bit in CFG1 register is set to 1 the module
will changed the state in according to four bits (CON0, CON1, CON2 and CON3) in CFG1 registers.
There are 4 bits to set 10 modes of operation:
CON3
0
0
0
0
0
0
CON2
0
0
0
0
1
1
CON1
0
0
1
1
0
0
CON0
0
1
0
1
0
1
Mode of operation
Free-run
Lock to Reference 1
Lock to Reference 2
Holdover
Lock to Reference 3
Lock to Reference 4
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
15
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
0
0
1
1
1
1
1
1
1
1
1
1
0
1
0
1
Lock to Reference 5
Lock to Reference 6
Not used
Not used
Other combinations are not supported and ignored. Bits 7 to 4 of CFG1 are reserved for future use and ignored in
this set.
Bit MS in CFG1 sets the module to Master – Slave operation, MS bit 0 (default) the module operates as Master and
MS bit 1 the module operates as slave in condition that a signal at SEC IN (pin 25) is present.
Register CFG2 used by customer to control behavior of the module for application needs.
7(MSB)
X
6
X
5
PBD
4
FREV
3
RESET
2
HLRST
1
REVEN
0(LSB)
AUTOEN
AUTOEN - when set to logic high, enabling automatic switching to other reference in the event of loosing current
reference according to priority set by registers PR1-PR4. When set to logic low, will not switch to other reference.
REVEN - when set to high, will enable revertive operation.
HLRST - when set to high, will erase previous operation history for holdover.
RESET - when set to high, will initiate internal reset of the module.
FREV – when set to high and if AUTOEN set to high will switch references based on their frequency offset (select
the best of available).
PBD - when set to high Phase Build Out is disabled.
The default values are:
CFG1: 0x00h
CFG2: 0x00h
Frequency Acquisition set for Primary PLL (FA1) - address 14h
FA1 register determines the bandwidth during frequency acquisition of PLL. The values of FA0-7 represent
frequency acquisition in Hz (0-256Hz).
The default values are:
FA1: 100
Bandwidth set registers for PLL1 (BW11, BW12) - address 15-16h
BW11 and BW12 registers determine the tracking bandwidth of the primary PLL. There four sets of bits each one
representing the corresponding tracking bandwidth. The table below shows the available combinations.
Px3
0
0
0
Px2
0
0
0
Px1
0
0
1
Px0
0
1
0
Bandwidth
NA
0.001Hz
0.01Hz
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
16
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
All others
1
0
1
0
1
0
0.1Hz
1
2
3
10
20
TBD
The default values are:
BW11: 0x23h
BW12: 0x01h
Frequency Acquisition and Bandwidth Track for PLL2 (FB2) – address 17h
FB2 register determines bandwidth for Secondary PLL in frequency acquisition and tracking modes. The tables
below represent available combinations for B0-B3 (frequency acquisition) and F0-F3 (tracking).
B3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
B2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
B1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
B0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Bandwidth
NA
10Hz
20Hz
30Hz
40Hz
50Hz
60Hz
70Hz
80Hz
90Hz
100Hz
200Hz
300Hz
400Hz
500Hz
600Hz
F3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
F2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
F1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
F0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Bandwidth
NA
3Hz
5Hz
10Hz
15Hz
20Hz
25Hz
30Hz
35Hz
40Hz
50Hz
60Hz
70Hz
80Hz
100Hz
200Hz
The default value:
FB2: 0x53h.
SPI Status Register (SST) – address 18h
The SST register represents current status of SPI communication. The address can be read only one of the
following values:
MESSAGE
SPIERRSTATOK
SPIERRRECOVERFLOW
SPIERRINVALIDADDR
SPIERRINVALIDWRITEADDR
VALUE
0
2
3
4
ACTION
If correct command was received by the module
If more then two bytes are received before the routine handled
If incorrect address was received by the module
If incorrect write address or value was received by the module
Customer ID Register (CID) – address 19h
The CID register contains unique customer identification number.
The default value:
CID: 0x03h.
Software ID Register (SID) – address 1Ah
The SID register contains unique software identification number.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
17
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
The default value:
SID: 0x18h. (will vary with new updates)
The Standard Timing Application in Systems
A typical timing application for telecommunication equipment is shown at the figure below. The system consists of
two Clock Cards (CC1 and CC1) and several Line Cards (LC 1 to LC N). The Clock Cards use two clock modules
SY10 to generate two redundant signal references for the whole box and the Line Cards use high frequency
synchronizer module SY05 as a high frequency reference signals for communication ICs (for e.g. transceivers). The
two Clock Cards are connected in such a way to provide a Master/Slave operation of two clocks. At CC the local
processors can configure and monitor SY10 module by serial port SPI. Two reference signals and optionally four
status signals from each Clock Card (STATUS 1 and STATUS 2) are distributed to all Line Cards. The STATUS 1
and 2 signals are HOLDOVER (pin 1 at SY10), FREERUN (pin 7), ALARM OUT (pin 11) and PLL UNLOCK (pin 17)
and they are connected to the corresponding pins at SY05 modules. For a particular application or a timing
application that best fits to you please contact Raltron.
HF OUT 1
SY05
1
LC 1
STATUS 1
HF OUT 2
SERIAL PORT
SY10
1
OUT (10)
SEC IN (25)
SY05
2
CC 1
LC 2
SEC IN (25)
SERIAL PORT
SY10
2
OUT (10)
CC 2
HF OUT N
SY05
N
STATUS 2
LC N
Figure 9. A typical timing application.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
18
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
•
SPECIFICATIONS
General
Specifications
Input Signals
Output Signal
Signal Quality
Performance
Power Supply
Warm Up Current Supply
Steady State Current Supply
Operating Temperature
Humidity
1.82” (D) x 1.82” (W) x 0.70” (H)
1.8” (D) x 1.8” (W) x 0.60” (H)
3.3VDC
700mA max @ 25°C
400mA max. @ 25°C
-20°C to 70°C
5% to 95% non-condensing
Internal Oscillators
OCXO
SC-cut for Stratum 3E
AT-cut for stratum 3
Number of Inputs
Input reference frequency
Signal Level
Time Reference characteristics
Number of Outputs
Output 1
Output 2
Output 3
Signal Level I/O
6
8kHz to 77.76MHz
HCMOS/TTL Compatible
User selectable
Mechanical
3.3V levels 5V tolerant
Bellcore: GR-1244-core 4.2
ITU-T: G.813
Bellcore: GR-1244-core 4.4
Bellcore: GR-1244-core 5.3
ITU-T: G.812
Bellcore: GR-1244-core 4.3
ITU-T: G.812
Bellcore: GR-1244-core 5.5
ITU-T: G.812
Bellcore: GR-1244-core 5.4
ITU-T: G.812
Wander Generation
Wander Tolerance
Jitter Generation and Transfer
Wander Transfer
Stratum 3E
Stratum 3
±4.6ppm
±4.6ppm
±1x10-8 /24 h
±0.37x10-6 /24 h
Initial Offset
±1x10-9
±50x10-9
Temperature
±8x10-9
±280x10-9
Drift
±1x10-9
±1x10-9
Phase Build-Out
Yes
No
DPLL bandwidth
Lock Time
Lock accuracy
0.001Hz
<700
±1x10-11
0.1Hz
<100sec
±1x10-11
Holdover frequency stability
Other ranges available on request
User define
User define
Phase Transient Tolerance
Free run accuracy
Varies from different oscillator used
Bellcore: GR-1244-core 3.2.1.R3-1
3
8KHz to 77.76MHZ
8KHz to 77.76MHZ
8KHz
HCMOS
Jitter Tolerance
Frequency Output
Performance
Metal box
Module on PCB
GR-1244-core 5.1
ITU-T: G.812
Bellcore: GR-1244-core 5.2
ITU-T: G.812
Bellcore: GR-1244-core 5.2
ITU-T: G.812
Bellcore: GR-1244-core 5.2
ITU-T: G.812
Bellcore: GR-1244-core 5.7
ITU-T: G.812
or adjustable up to 20Hz
GR-1244-core 3.5
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
19
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
•
PIN ASSIGNMENT
34
1
HOLDOVER
EX REF 5
33
2
REF 3
EX REF 1
32
3
REF 1
EX REF 3
31
4
REF 4
30
5
REF 2
VCC
GND
29
6
REF 5
EX REF 2
28
7
FREERUN
EX REF 4
27
8
REF 6
GND
26
9
GND
SEC IN
25
10
M/S OUT
OPT OUT1
24
11
DIN
23
12
OPT OUT2
GND
22
13
CNT 1
SCLK
21
14
CNT 3
OUT
20
15
CNT 2
DOUT
19
16
MS/FR
GND
18
17
EX REF 6
ALARM OUT
PLL UNLOCK
Figure 10 – Bottom view
Pin #
1
2
3
4
5
6
7
8
10
11
12
13
14
15
Name
HOLDOVER
REF 3
REF 1
REF 4
REF 2
REF 5
FREERUN
REF 6
M/S OUT
ALARM OUT
OPT OUT2
CNT 1
CNT 3
CNT 2
16
MS/FR
17
9,18,22,26,30
34
19
20
21
23
24
25
27
28
29
31
32
33
PLL UNLOCK
GND
VCC
DOUT
OUT
SCLK
DIN
OPT OUT1
SEC IN
EX REF 4
EX REF 2
EX REF 6
EX REF 3
EX REF 1
EX REF 5
Description
Holdover Signal -> the output is high when the unit is in holdover mode
Reference 3 Signal -> See Indication section on page 4
Reference 1 Signal -> See Indication section on page 4
Reference 4 Signal -> See Indication section on page 4
Reference 2 Signal -> See Indication section on page 4
Reference 5 Signal -> See Indication section on page 4
Free-run Signal -> the output is high when the unit is in the free run mode
Reference 6 Signal -> See Indication section on page 4
Master/Slave Synchronizing output (To be connected to slave module SEC-IN
Alarm signal -> the output is high when there is an alarm in the module.
Optional Output 2-> the secondary output of the synchronized signal
Control Input 1 -> the external input for selecting mode of the unit – see table.
Control Input 3 -> the external input for selecting mode of the unit – see table.
Control Input 2 -> the external input for selecting mode of the unit – see table.
Master/Slave Selection or Frame SPI Input -> to select master or slave – master/ slave operation
of two clocks or in case of using SPI it is Frame synch signal for communication.
PLL Unlocked Signal -> the output is high when the unit is not locked to any of the references
Ground
Positive Voltage Supply
Serial Data Output -> SPI serial communication interface data output
Synchronized Output -> the output of the synchronized signal
Serial Clock Input -> SPI serial communication interface clock input
Serial Data Input/ -> SPI serial communication interface data input
Optional Output 1-> the secondary output of the synchronized signal,.
SEC Input -> the input from the second clock module – master/slave operation of two clocks.
External Reference 4 Input -> the input signal from reference 4
External Reference 2 Input -> the input signal from reference 2
External Reference 6 Input -> the input signal from reference 6
External Reference 3 Input -> the input signal from reference 3
External Reference 1 Input -> the input signal from reference 1
External Reference 5 Input -> the input signal from reference 5
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
20
SYNCHRONOUS EQUIPMENT
STRATUM 3/3E CLOCK UNIT – SY10
•
MECHANICAL DIMENSIONS
.440
(11.18)
1.60
(40.64)
.085
(2.16)
1
18
17
.910
.200
(5.08)
PCB
.071
(1.82)
.065
(1.65)
.076
(1.93)
.100
(2.54)
1.400 ±.005
(35.56 ±.127)
.210
(4.57)
(4 PLCS)
1.700
(43.18)
MARKING
AREA
34
.100
CL (2.54)
.030
(0.76)
1
CL
.910
(23.11)
1.82 SQ.
(46.23 SQ.)
.060 (4 PLCS)
(1.52)
.630
(16.00)
NOTES:
UNLESS OTHERWISE SPECIFIED,
ALL TOLERANCES ARE: ±.005 (.127 mm).
Figure 11 – The mechanical dimensions.
Figure 11 shows the mechanical dimension of the SY10 module. The module can be supplied in two different types
of packaging:
-
Metal box
Module without packaging
The label on the module shows part number, factory name, week and year of production. Without metal cover
maximum height reaches 0.60”.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19th St ! Florida 33172 ! U.S.A.
Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: [email protected] ! Internet: http://www.raltron.com
21