SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC Date: January 7, 2003 SY02-FEC • INTRODUCTION The SY02-FEC is a high frequency crystal-based PLL synchronizer designed as a module level subsystem for easy incorporation into telecommunication equipment SONET/SDH/ATM/DWDM. Supports FEC (forward error Correction) or OC-N Frequencies. • FEATURES - Low jitter output from intrinsically low jitter VCXO or VCSO; - User Selected one or two input references up to 800MHz ( See Table on page 3) - One high frequency LVPECL output with enable/disable function up to 800MHz (pre-select frequency value – upon order) - Alarms status and VCXO monitor; - The unit changes timing modes in response to external events; - J-TAG service port for re-programming and servicing; - 3.3V DC power supply - Small dimensions: 0.8” x 1.00” • APPLICATIONS - ATM - SDH - PDH - SONET - DWDM - FEC - Other telecommunication equipment. th RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC A=622.08MHz Lock Monitor ALARM REF REF IN Q IN VCXO Monitor Q Input Freq. Sel B= 666.513MHz MUX, FPD, Counters & Logic LOOP FILTER OUT VCXO OUT J-TAG PORT SY02-FEC E/D Figure 1 – Block Diagram (***Components outside the dotted line are user supplied) . • DESCRIPTION The SY02-FEC is a High Frequency Phase Lock Loop has been designed as a module level subsystem for easy incorporation into telecommunication equipment. The module generates the high frequency (up to 800MHz) output from a low jitter VCXO (Crystal Based Oscillator) or VCSO (SAW based oscillators). The output can be disabled externally by setting OUTEN pin high. The SY02-FEC can be locked to a user defined input reference/s signal/s (from 1.024MHz to 800MHz…for options please see table ). Raltron’s SY02-FEC device could be used as a frequency translator in PLL circuits or frequency re-generator device in cases where jitter cleaning and filtering is required. The module has a fast locking time and tolerates reference inputs with different duty cycles. The loop bandwidth is optimized in accordance with the VCXO used and required output performance. The ALARM output signals monitor the status of the phase lock loop and indicates LOLD (Loss of Lock Detect). If the reference REF IN is absent, the SY02-FEC will automatically switch to free run mode and LOLD will show “0” logic level. The SMD package dimensions are 0.80”x1.00” inch and powered by a supply of 3.3V. ALARM STATES LOL D 0 1 ALARM Module in Free-run Module locked Input Reference Control select CNT Selected Option 0 Regenerated 622.08MHz into 622.08MHz 1 Translates 666.5143MHz into 622.08MHz th RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC • PIN DESCRIPTION Name 1 2 Signal Technology Description Ref In Input Reference Signal 3 Ref In LOL 4 MNTR 6 7 8 N/C GND Enable/Disable 9 10 OUT Input Reference Complimentary signal Lock Detect Alarm out – High when locked; Low when unlocked VCXO Monitor out- DC control voltage offset indicator (when locked shall be within); 0.3<Vmntr<3.0 (for 3.3V supply) No Connect Ground Output Enable - > enables the output, active high or floating Disables the output, active low Oscillator Output -> Output of the module 11 12 OUT N/C CNT 13 14 15 16 N/C N/C GND Vcc • Oscillator Complementary Output -> Output of the module No Connect Frequency Select; Low-Primary Frequency; High Secondary Frequency No Connect No Connect Ground Positive supply voltage LV/PECL Min Vcc-1.680 VL Typ Vcc-1.620 Max Vcc-1.560 VH/ DC Voltage Min Typ Vcc-1.085 Vcc-1.025 Max Vcc-0.885 LV/PECL Vcc-1.680 Vcc-1.620 Vcc-1.560 Vcc-1.085 Vcc-1.025 Vcc-0.885 0 0.15 0.3 2.97 3.3 3.465 DC DC 0.3<Vmntr<3.0 ----- ----- ----- ---- ------ ------ ------ ----- ----- ----- ---- ------ ------ ------ DC 0 0.15 0.3 2.97 3.3 3.465 LV/PECL Vcc-1.680 Vcc-1.620 Vcc-1.560 Vcc-1.085 Vcc-1.025 Vcc-0.885 LV/PECL Vcc-1.680 Vcc-1.620 Vcc-1.560 Vcc-1.085 Vcc-1.025 Vcc-0.885 ----- ----- ----- ---- ------ ------ ------ DC 0 0.15 0.3 2.97 3.3 3.465 ----- ----- ----- ---- ------ ------ ------ ----- ----- ----- ---- ------ ------ ------ ----- ----- ----- ---- ------ ------ ------ DC – 3.3V ----- ----- ---- 2.97 3.3 3.465 ORDERING INFORMATION o Input/Output Frequencies available; Frequency 77.7600MHz 78.125MHz 78.6432MHz 82.9440MHz 92.6000MHz 100.000MHz 112.000MHz 114.000MHz 125.000MHz 133.000MHz 139.264MHz 155.520MHz 156.250MHz 161.1328MHz 166.6286MHz 167.3316MHz Suffix O3 B3 B4 B5 U3 B6 B7 B8 G2 G4 E6 O4 G6 B9 B10 C1 Frequency 168.0407MHz 175.0000MHz 178.9440MHz 184.3200MHz 311.0400MHz 622.0800MHz 625.000MHz 644.5312MHz 666.5143MHz 669.1281MHz 669.3266MHz 690.5692MHz 710.9486MHz 719.7344MHz 777.6000MHz th Suffix C2 C3 C4 C5 O6 O7 C8 C9 C10 F1 F2 F3 F4 F5 F6 RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC P/N System SY02-FEC – IP <Primary Input Frequency> - IS<Second Input Freq.>-OU<Output>S-T<Temp> See above Chart If not listed Place NL and state the Freq.) See above chart (If not listed place NL and state the Freq. - must be higher in value than the primary Input reference) If second Freq. Not applied place NA See above Chart If not listed Place NL and state the Freq.) Supply Voltage; 4 – 3.3V Operating Temperature Range; C - 0°C to 70°C I - -40°C to +85°C • SPECIFICATION General Specifications Mechanical Power Environment Input Signals Output Signals Signal Quality Performance Internal Oscillators Number of Reference Inputs Input reference frequency Signal Level Number of Outputs Output 1 Output 1 Signal Level Duty Cycle Tracking/Capture Range Jitter generation Jitter attenuation Jitter tolerance 1.000” x 0.800”x0.235” SMT Module FR4 16 pins dual-in-line 3.3VDC +/-5%, <200mA Operating Temperature Humidity VCXO or VCSO 2 Per selected table on page 3 LVPECL 1 Per selected table on page 3 LVPECL (W/ Complimentary option) 50+/-10% ±50ppm APR min <0.001UI RMS <0.001UI RMS <0.0001 UI RMS <0.0001 UI RMS -40dB -10dB 2 µs, 10 Hz (0.05 UI @ 8KHz) Regulated 0°C to 70°C or -40°C to +85°C 5% to 95% non-condensing Depends on the frequency th (other input frequencies available) Voh; 2.272V min ; Vol; 1.68Vmax other frequency contact Raltron Voh; 2.272V min ; Vol; 1.68Vmax 50%+/-5% available upon request HPF 30Hz HPF 500Hz HPF 12KHz HPF 100KHz Fj=10Hz~1KHz Fj=1KHz~10MHz RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com SYNCHRONOUS EQUIPMENT HIGH FREQUENCY CLOCK REGENERATOR - SY02-FEC • REFLOW PROFILE 250 200 150 XY (Scatter) 1 100 50 0 0 • 1 2 3 4 5 6 7 8 OUTLINE DRAWING .040 (1.02) .250 MAX. (6.35 MAX.) 1.000 (25.4) MARKING AREA SIDE VIEW .150 (3.81) .700 (17.78) .050 (1.27) .100 TYP. (2.54) 9 10 11 12 13 14 15 16 8 7 2 1 .800 (20.32) 6 4 3 .055 (1.4) DENOTES PIN 1. TOP VIEW BOTTOM VIEW th RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com