SYNCHRONOUS EQUIPMENT HIGH FREQUENCY HITLESS SYNCHRONIZER - SY02-HLPL SY02-HLPL PRELIMINARY SPECIFICATION Date: July 1, 2002 • INTRODUCTION The SY02-HLPL is a dual input reference hitless switching device with high frequency crystal-based PLL synchronizer designed as a subsystem module. Mainly used at high speed Line Interface Cards in telecommunication products mainly related to STN-n or OC-n. The SY02-HLPL is a synchronization solution for timing and jitter topics specified within ITU-T Recommendations G.813, ETSI -ETS 300 4624, and Bellcore GR-1244-CORE. • FEATURES - Low jitter output from intrinsically low jitter VCXO or VCSO; - Two input references from 8KHz to 77.76MHz (See page 3 for options) - One high frequency LVPECL output with enable/disable function up to 800MHz (pre-select frequency value – See page 3 for options) - Alarms and status; - Provides free running clock output; - Provides a manual input frequency selection - The unit changes timing modes in response to external events; - J-TAG service port for re-programming and servicing; - 3.3V DC power supply - Small dimensions: 0.96” x 1.050” • APPLICATIONS - ATM - SDH - PDH - SONET - Other telecommunication equipment. th RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com 1 SYNCHRONOUS EQUIPMENT HIGH FREQUENCY HITLESS SYNCHRONIZER - SY02-HLPL ALARM FRS REF 1 IN REF 2 IN CNT FR MUX, FPD, Counters & Logic OUT LOOP FILTER VCXO OUT EN OUT J-TAG PORT • DESCRIPTION The SY02-HLPL synchronization module is a high frequency PLL that performs hitless switching plus additional features necessary for timing at high-speed Line Interface Cards. The functional block diagram is shown in the figure above . The SY02-HLPL receives two reference signals, from 8KHz to 77.76MHz (See page 3 for available options) and using PLL synthesizer generates a high frequency signal necessary for transceivers or framers. The PLL that is complemented by high-speed logic that provide processing, switching between the timing modes, alarm and status messages and etc. A high quality VCXO provides very low jitter at the output. The SY02-HLPL incorporates a High Frequency Phase Lock Loop has been designed to generate high frequency (up to 800MHz) output from a low jitter VCXO (Crystal Based Oscillator) or VCSO (SAW based oscillators). The output can be disabled externally by setting OUTEN pin high. The module supports a MANUAL operating mode where unit will switch according to a control pin CNT. During an event where the external reference signal disappears, the user instruct a reference change into the module through the control pin. The ALARM output signals monitor the status of the phase loop LOL (Loss of Lock) and LOR (Loss of Reference). If the reference REF IN is absent, the SY02-HLPL will automatically switch to free run mode and FRS output will indicate it. The SY02-HLPL is provided in an SMD package dimensions are 0.96x1.050 inch and power supply is 3.3V. - OUTPUT PROGRAMMING OUTEN 0 1 0 FR 0 X 1 OUTPUT Locked to Reference Output Disabled Free-Run - ALARM STATES LOL 0 1 0 LOR 0 0 1 ALARM No alarm 1 1 - Input Reference Selection CNT Input Reference Selection 0 Ext Ref 1 1 Ext Ref 2 th RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com 2 SYNCHRONOUS EQUIPMENT HIGH FREQUENCY HITLESS SYNCHRONIZER - SY02-HLPL • PIN DESCRIPTION Name Signal Technology Description DC 0 VL Typ 0.25 (0.15) ----- ----- ----- ----- Min 1 ENABLE 2 3 4 TCK TDO REFA IN 5 SEL 6 RESET 7 REFB IN 8 9 GND FRS 10 Vcc 11 12 NC ALARM 13 FR 14 15 16 17 18 TDI TMS OUT GND OUT • Output Enable - > the input pin to enable the output, active low J-TAG port for factory usage – TCK J-TAG port for factory usage – TDO Reference A Input -> Reference A input signal Select Input Reference -> input to select A (SEL=0) or B (SEL=1) Reset input -> Reset active high In normal operation must be Grounded Reference B Input -> Reference B input signal Ground Free-Run Status -> Output indicates that the module is in free run, active high Positive supply voltage Not Connected Alarm out -> Alarm output indicates loss of reference or loss of lock – High when the unit is Unlocked Free-Run -> Control input to select free run of the module, active high J-TAG port for factory usage – TDI J-TAG port for factory usage – TMS Oscillator Output -> Output of the module Ground Complimentary Output 0.5 (0.3) VH/ DC Voltage Min 4.5 (2.97) 5.0 (3.3) Max 5.25 (3.465) ----- ---- ------ ------ ------ ----- ---- ------ ------ 0.25 (0.15) 0.5 (0.3) 4.5 (2.97) 5.0 (3.3) 5.25 (3.465) DC 0 0.25 (0.15) 0.5 (0.3) 4.5 (2.97) 5.0 (3.3) 5.25 (3.465) DC – 5V (3.3V) ----- 0 0.5 (0.3) ----- 4.5 (2.97) ------ 0 DC ----- Typ HCMOS (3.3 Tolerable) DC HCMOS (3.3 Tolerable) ----- 0 Max 0.5 (0.3) ---- 4.5 (2.97) ---- ---- ---- ----- ----- ---- ------ ------ ------ 0 0.25 (0.15) 0.5 (0.3) 4.5 (2.97) 5.0 (3.3) 5.25 (3.465) 5.0 (3.3) ------ 5.25 (3.465) ------ ----- ----- ---- 4.5 (2.97) ------ DC 0 0.25 (0.15) 0.5 (0.3) 4.5 (2.97) 5.0 (3.3) 5.25 (3.465) DC 0 0.25 (0.15) 0.5 (0.3) 4.5 (2.97) 5.0 (3.3) 5.25 (3.465) ----- ----- ----- ---- ------ ------ ------ ----- ----- ----- ---- ------ ------ ------ Vcc-1.680 Vcc-1.620 Vcc-1.560 Vcc-1.085 Vcc-1.025 Vcc-0.885 ----- ----- ---- ------ ------ ------ Vcc-1.680 Vcc-1.620 Vcc-1.560 Vcc-1.085 Vcc-1.025 Vcc-0.885 LV/PECL ----LV/PECL ORDERING INFORMATION o Frequency 8KHz 1.544MHz 2.048MHz 8.192MHz 12.352MHz 16.384MHz o Input Frequencies available; Suffix F8 T1 E1 E2 T2 E3 Frequency 19.44MHz 24.704MHz 32.768MHz 38.88MHz 51.84MHz 62.50MHz Suffix O1 T3 E4 O2 D1 G1 Frequency 77.76MHz Suffix O3 Output Frequencies available (in MHz); Frequency 51.84 62.50 77.76 125 133 155.52 Suffix D1 G1 O3 G2 G3 O4 Frequency 156.25 166.328 622.08 666.513 th Suffix G4 C1 O5 C2 RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com 3 SYNCHRONOUS EQUIPMENT HIGH FREQUENCY HITLESS SYNCHRONIZER - SY02-HLPL P/N System SY02-FEC – IP < Input Frequency> - OU<Output Frequency>-S-T<Temp. Range>-C <Cover Option> See above Chart If not listed Place NL and state the Freq.) See above Chart (If Output Freq. Not applied place NA and state the Freq.) Supply Voltage; 2- 5V 4 – 3.3V Operating Temperature Range; C - 0°C to 70°C I -40°C to +85°C Cover Option; M – Metal Cover N - Non Covered unit For other Options please contact the factory • SPECIFICATION General Specifications Mechanical Power Environment Input Signals Output Signals Signal Quality Performance Internal Oscillators Number of Reference Inputs Input reference frequency Signal Level Number of Outputs Output 1 Output 1 Signal Level Duty Cycle Tracking/Capture Range Free Run stability Jitter generation Jitter attenuation Jitter tolerance 0.96” x 1.050” SMT Module FR4 18 pins dual-in-line 3.3VDC, <200mA Operating Temperature Humidity VCXO or VCSO 2 User select LVCMOS 1 User select LVPECL (W/ Complimentary option) 50+/-10% ±50ppm APR min ±30ppm (VCXO) ±150PPM(VCSO) <0.001UI RMS <0.001UI RMS <0.0001 UI RMS <0.0001 UI RMS -40dB -10dB 2 µs, 10 Hz (0.05 UI @ 8KHz) Regulated 0°C to 70°C 5% to 95% non-condensing Depend of the frequency See page 3 for input frequencies See page 3 for input frequencies Voh; 2.97V min ; Vol; 0.33Vmax th See page 3 for output frequencies Voh; 2.272V min ; Vol; 1.68Vmax 50%+/-5% available upon request T=+25C; Vcc/load-=nominal HPF 30Hz HPF 500Hz HPF 12KHz HPF 100KHz Fj=10Hz~1KHz Fj=1KHz~10MHz RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com 4 SYNCHRONOUS EQUIPMENT HIGH FREQUENCY HITLESS SYNCHRONIZER - SY02-HLPL • OUTLINE DRAWING 1.040 (26.42 mm) 1.00 (25.40mm) .840 (21.34 mm) .960 (24.38mm) MARKING LABEL 1.050 (26.67mm) .800 (20.32 mm) 10 9 TOP VIEW .416 MAX. (10.57mm MAX. .035 (.89 mm) .065 (1.65 mm) .100 (.2.54 mm) .865 (21.97 mm) .100 (2.54mm) 18 1 PCB FOOTPRINT .019 (.48 mm) .100 (2.54 mm) SIDE VIEW TABS FRONT VIEW • REFLOW PROFILE 250 Temp (C) 200 150 100 50 0 0 1 2 3 4 5 6 7 8 Time (minutes) th RALTRON ELECTRONICS CORP. 10651 N.W.19 St Florida 33172 U.S.A. Tel: 305 593-6033 Fax: 305-594-3973 e-mail: [email protected] Internet: http:/www.raltron.com 5