TEN06 SERIES 6 WATTS DC-DC CONVERTER FEATURES • 6 WATTS MAXIMUM OUTPUT POWER • OUTPUT CURRENT UP TO 1200mA • PACKAGE, 1.61 x 1.02 x 0.33 INCH • HIGH EFFICIENCY UP TO 85% • 2:1 WIDE INPUT VOLTAGE RANGE • FIVE-SIDED SHIELD • SWITCHING FREQUENCY 100k TO 1500kHz. • NO EXTERNAL INPUT AND OUTPUT CAPACITOR NEEDED • LOW RIPPLE & NOISE • OVER CURRENT PROTECTION • SHORT CIRCUIT PROTECTION • LONG LIFE WITHOUT ELECTROLYTIC CAPACITOR • CE MARK MEETS 2006/95/EC, 2011/95/EC AND 2004/108/EC • SAFETY MEETS J60950-1, UL60950-1, EN60950-1 AND IEC60950-1 • ISO9001 CERTIFIED MANUFACTURING FACILITIES • COMPLIANT TO RoHS EU DIRECTIVE 2011/65/EU DESCRIPTION The TEN06 series offer 6 watts of output power from a 1.61 x 1.02 x 0.33 inch package without derating to 50ºC and without external input/output capacitor. The TEN06 series with 2:1 wide input voltage of 4.5~9VDC, 9~18VDC, 18~36VDC and 36~75VDC and features 500VAC of isolation, short-circuit protection. APPLICATIONS Wireless Network Telecom/Datacom Industry Control System Measurement Equipment Semiconductor Equipment T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted INPUT SPECIFICATIONS OUTPUT SPECIFICATIONS Maximum output power 6 Watts Voltage accuracy ± 1% Minimum load 0% Line regulation LL to HL at Full Load ± 0.2% Load regulation No load to Full load ± 0.5% Ripple and noise 50MHz bandwidth See table Maximum temperature drift ±0.02% / ºC Transient response recovery time 25% load step change 500µs Short circuit protection Continuous, automatics recovery Over current protection 150% OUTPUT VOLTAGE ADJUSTMENT TERMINAL(Vset ) (Note 6) Model number XXS33 XXS05 XXS12 XXD12 Model number XXS33 XXS05 XXS12 XXD12 Open 3.3VDC 5VDC 12VDC ±12VDC -OUTPUT shorted 3.67VDC 6VDC 15VDC ±15VDC -OUTPUT connected Open with resistance (7) 3.3VDC 3.3 to 3.67VDC (8-1) 5VDC 5 to 6VDC (8-3) 12VDC 12 to 15VDC (8-5) ±12VDC ±12 to ±15VDC (8-6) +OUTPUT shorted 2.84VDC 4.3VDC +OUTPUT connected with resistance (7) 3.3 to 2.84VDC (8-2) 5 to 4.3VDC (8-4) - GENERAL SPECIFICATIONS Efficiency Isolation voltage Isolation resistance Isolation capacitance Design meet safety standard Switching frequency Case material Base material Weight Dimension MTBF (Note 1) Page 1 of 3 Input voltage range 5VDC nominal input 12VDC nominal input 24VDC nominal input 48VDC nominal input Input filter Input surge voltage 100mS max 4.5 ~ 9VDC 9 ~ 18VDC 18 ~ 36VDC 36 ~ 75VDC L-C filter 5VDC input 12VDC input 24VDC input 48VDC input 15VDC 100ms, max. 36VDC 100ms, max. 50VDC 100ms, max. 100VDC 100ms, max. Remote ON/OFF See figure 1 ENVIRONMENTAL SPECIFICATIONS Operating ambient temperature Operating case temperature range Storage temperature range Cooling -25ºC ~ +85ºC (with derating) -25ºC ~ +100ºC -55ºC ~ +125ºC Nature convection Thermal shock MIL-STD-810F At no operation, 10~55~10Hz (sweep for 15min.) amplitude Vibration 1.5mm constant (maximum 9G X, Y, Z 2hrs each) Operating humidity range 20% to 95% RH Storage humidity range 20% to 95% RH EMC CHARACTERISTICS See table Input to Output 500 VAC, min. 1minute EMI (Note 9) Input (Output) to Case 500 VAC, min. 1minute Input to Output 50M ohms, min. 500VDC Input (Output) to Case 50M ohms, min. 500VDC 300 pF, max. EN55022 Class A, Class B IEC60950-1, J60950-1, UL60950-1, EN60950-1 Full load to No load 100k to 1500k Hz Metal case None 20.0g (0.71oz) 1.61 x 1.02 x 0.33 Inch (41 x 25.8 x 8.5 mm) BELLCORE TR-NWT-000332 3.706 x 106 hrs MIL-HDBK-217F 1.679 x 106 hrs www.pduke.com 2013/5/3 TEN06 SERIES 6 WATTS Model Number Input Range TEN06-05S33 TEN06-05S05 TEN06-05S12 TEN06-05D12 TEN06-12S33 TEN06-12S05 TEN06-12S12 TEN06-12D12 TEN06-24S33 TEN06-24S05 TEN06-24S12 TEN06-24D12 TEN06-48S33 TEN06-48S05 TEN06-48S12 TEN06-48D12 4.5 ~ 9 VDC 4.5 ~ 9 VDC 4.5 ~ 9 VDC 4.5 ~ 9 VDC 9 ~ 18 VDC 9 ~ 18 VDC 9 ~ 18 VDC 9 ~ 18 VDC 18 ~ 36 VDC 18 ~ 36 VDC 18 ~ 36 VDC 18 ~ 36 VDC 36 ~ 75 VDC 36 ~ 75 VDC 36 ~ 75 VDC 36 ~ 75 VDC DC-DC CONVERTER (2) Output Current Output Output Output Voltage Voltage Range Min. load Full load Ripple & Noise 3.3 VDC 5 VDC 12 VDC ±12 VDC 3.3 VDC 5 VDC 12 VDC ±12 VDC 3.3 VDC 5 VDC 12 VDC ±12 VDC 3.3 VDC 5 VDC 12 VDC ±12 VDC 2.84 ~ 3.67 VDC 4.3 ~ 6 VDC 12 ~ 15 VDC ±12 ~ ±15 VDC 2.84 ~ 3.67 VDC 4.3 ~ 6 VDC 12 ~ 15 VDC ±12 ~ ±15 VDC 2.84 ~ 3.67 VDC 4.3 ~ 6 VDC 12 ~ 15 VDC ±12 ~ ±15 VDC 2.84 ~ 3.67 VDC 4.3 ~ 6 VDC 12 ~ 15 VDC ±12 ~ ±15 VDC 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 0mA 1200mA 1000mA 500mA ±250mA 1500mA 1200mA 500mA ±250mA 1500mA 1200mA 500mA ±250mA 1500mA 1200mA 500mA ±250mA (3) No Load Input Current 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p (4) Eff (%) 80mA 65mA 140mA 140mA 45mA 55mA 60mA 55mA 15mA 20mA 30mA 30mA 15mA 15mA 20mA 15mA 74 77 83 83 76 80 85 85 77 82 85 85 77 80 85 85 (5) Capacitor Load max 6600µF 3000µF 1400µF ±510µF 6600µF 3000µF 1400µF ±510µF 6600µF 3000µF 1400µF ±510µF 6600µF 3000µF 1400µF ±510µF Note: 1. BELLCORE TR-NWT-000332. Case 1:50% Stress, temperature at 40ºC. MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment). 2. Typical value at nominal input and full load. 3. Typical value at nominal input and no load. 4. Typical value at nominal input and full load. 5. Test by minimum input and constant resistive load. 6. The following output voltage can be obtained by connecting this terminal to an output + or – terminal. Unless the output voltage is adjusted, this terminal should be open. 7. In addition, the voltage can be adjusted not by shorting these terminals, but by connecting them to resistances as shown below. 8. Arithmetic expression connected resistance: R ( kΩ ) 8-1 Vo=(3.3*R+36.7)/(R+10) 8-2 Vo=(3.3*R+36.7)/(R+12.92) 8-3 Vo=2.5*[2+2.7/(R+6.8)] 8-4 Vo=2.5*[2-2.7/(R+9.5)] 8-5 Vo=2.5+9.5(R+10.9)/(R+8.2) [Between two outputs] 8-6 Vo=2.5+22*(R+12.7)/(R+10) [Between two outputs] Figure 1 9. The TEN06 series standard module meets EN55022 Class A and Class B with external components. For more detail information, please contact with P-DUKE. CAUTION: This power module is not internally fused. An input line fuse must always be used. TEN06-48S05 Derating Curve TEN06-48S05 Efficiency VS Input Voltage Page 2 of 3 TEN06-48S05 Efficiency VS Output Current www.pduke.com 2013/5/3 TEN06 SERIES 6 WATTS MECHANICAL DRAWING DC-DC CONVERTER : 1. All dimensions in Inch (mm) Tolerance: X.XX±0.02 (X.X±0.5) X.XXX±0.01 (X.XX±0.25) 2. Pin pitch tolerance ±0.01 (0.25) 3. Pin dimension tolerance ±0.004 (0.1) PIN CONNECTION PIN 1 2 3 4 5 6 7 8 9 10 11 Page 3 of 3 SINGLE + INPUT CTRL - INPUT NC - OUTPUT Vset + OUTPUT CASE CASE CASE STAND OFF CASE STAND OFF DUAL + INPUT CTRL - INPUT - OUTPUT COMMON Vset + OUTPUT CASE CASE CASE STAND OFF CASE STAND OFF EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. ( ) for dual output trim www.pduke.com TRIM UP 5(4) TRIM DOWN 6 RU 6(6) RD 7 2013/5/3