Click Here to download this file: http://www.murata-ps.com/data/power/ncl/tdc_wpc10rc.pdf

www.murata-ps.com
OBSOLETE
WPC10 Series
10W
0W R
Regulated 2:1 Wide
ide Input Range DC/DC Converter
Order Code
Nominal
Output Output Current Voltage Regulation
Input
Noise
Voltage Min Rated Line
Load
Voltage
Load Load
V
V
mA
mA
±
±
mVpp
WPC10R24S05C
WPC10R24S12C
WPC10R24D15C
Efficiency
SELECTION GUIDE
Recommended
Alternative
%
NPH10S2405IC
NPH10S2412IC
BWR-15/575-D24A-C
Obsolete, recommended alternative:
(click to view data sheets)
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range
Reflected ripple current
Continuous operation
Min.
Typ.
Max.
Units
18
24
20
36
50
V
mAp-p
Min.
Typ.
Max.
Units
10
W
%
%/ºC
FEATURES
OUTPUT CHARACTERISTICS
„
RoHS compliant
„
Safety approval (cULus)
„
Meets EN55022 level A & B for conducted
Emissions with a 10 micro farad external
capacitor
„
Industry standard pinouts
„
Industry standard package
„
Low profile 0.4 inch (10mm)
Parameter
Conditions
Rated Power
Voltage set point accuracy
Temperature coefficient
Line regulation
Load regulation
Ripple & noise
Singles
Duals
Singles
Min load to rated load
Duals
BW = 5Hz to 20MHz
Low line to high line
„
Short circuit protection
ABSOLUTE MAXIMUM RATINGS
„
Temperature shutdown
Output short circuit protection
Internal power dissipation
Maximum case temperature
DESCRIPTION
The WPC10 series is a family of DC/DC converters
that offer regulated outputs over an input voltage
range 18 - 36V and over a wide specification case
temperature range of -40°C to +100°C.
The 350kHz switching frequency and forward
converter topology provide optimum performance
in a space-saving package. The design uses
all surface mounted components, including
magnetics, to provide enhanced reliability.
All models will operate under very low load
conditions, although the minimum load is required
to guarantee full parametric functionality. A metal
package is utilized for decreased radiated noise.
The product range has been recognised by Underwriters Laboratory (UL) to UL 1950 for operational
insulation, file number E179522 applies.
60Hz, 10 seconds
75
mVp-p
Min.
Max.
Units
Vpk
GΩ
pF
μArms
10
1500
100
VISO = 240VAC, 60Hz
Min.
Specification (ambient)
Case temperature
Storage
-40
-40
-55
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
MIL-HDBK-217F Ground benign
Typ.
1500
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Switching frequency
MTTF
%
Continuous
2.5W
+110ºC
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Resistance
Capacitance
Leakage current
±1
±0.02
±0.2
±0.2
±0.2
±0.5
Typ.
Typ.
350
933
Max.
Units
71
100
125
ºC
Max.
Units
KHz
KHr
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_WPC10.D01 Page 1 of 3
WPC10 Series
10W Regulated 2:1 Wide Input Range DC/DC Converter
THERMAL DERATING CURVE
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions WPC10 series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1500V Vpk for 10 seconds.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The WPC10 series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be
expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard
requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
FUSING
The WPC10 series DC/DC converter may be optionally fused with a 2A fuse. The input must be SELV or TNV according to EN60950/IEC950. UL recognition was obtained without an
input fuse.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is UNS C36000 brass plated with matte tin 100 micro-inches min., over nickel, 40-80 micro-inches. The series is backward
compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_WPC10.D01 Page 2 of 3
WPC10 Series
10W Regulated 2:1 Wide Input Range DC/DC Converter
MECHANICAL DIMENSTIONS
.415
[10.54]
PIN CONNECTIONS
.230 [5.84]
MIN
.020 [0.51]
SIDE VIEW
1.000 [25.40]
.900
[22.86]
4
1
.600 [15.24]
5
Singles
Duals
1
+VIN
+VIN
2
-VIN
-VIN
4
+VOUT
+VOUT
5
No pin
Common
6
-VOUT
-VOUT
.500
[12.70]
2
.400 [10.16]
Function
Pin
6
.100 [2.54]
2.000
[50.80]
1.400
[35.56]
.600
[15.24]
.000
[0.00]
.000 [0.00]
BOTTOM (PIN SIDE) VIEW
Weight: 35g (Typ.)
All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
Unless otherwise stated all dimensions are in inches (mm) ±0.01 (0.25).
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/locations