NME1515SC

NME1515SC
www.murata-ps.com
Isolated 1W Single Output DC/DC Converter
SELECTION GUIDE
Order Code
Nominal Input
Voltage
NME1515SC
Output
Voltage
V
V
15
15
Input
Output Current Current at Rated
Load
mA
mA
67
Efficiency
Package
Style
%
81
82
SIP
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Continuous operation
13.5
15
FEATURES
Voltage range
Reflected ripple current
16.5
90
V
mA p-p
„
RoHS compliant
OUTPUT CHARACTERISTICS
„
Single isolated output
Parameter
Conditions
Min.
Typ.
Max.
Units
Rated Power1
Voltage Set Point Accuracy
Line regulation
Load Regulation
Ripple and Noise
TA=-40°C to 120°C
See tolerance envelope
High VIN to low VIN
10% load to rated load
BW=DC to 20MHz
1.0
W
1.05
3
1.2
10
150
%/%
%
mV p-p
Typ.
Max.
Units
„
1kVDC isolation
„
UL 94V-0 package material
„
Industry standard pinout
„
No heatsink required
„
Internal SMD construction
„
Fully encapsulated with toroidal magnetics
„
No external components required
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
1000
„
Custom solutions available
GENERAL CHARACTERISTICS
„
PCB mounting
Switching frequency
DESCRIPTION
TEMPERATURE CHARACTERISTICS
The NME1515SC DC/DC converter is particularly
suited to isolating power rails. The galvanic isolation allows the device to be configured to provide
an isolated negative rail in systems where only
positive rails exist.
Parameter
Conditions
Min.
Specification
Storage
Case Temperature above
ambient
Cooling
All output types
-40
-50
Parameter
VDC
GΩ
10
Conditions
Min.
Typ.
Max.
100
Typ.
Units
kHz
Max.
85
130
Units
°C
32
Free air convection
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN
300°C
450mW
18V
1. See derating curve.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NM1515SC.A02 Page 1 of 3
NME1515SC
Isolated 1W Single Output DC/DC Converter
TEMPERATURE DERATING GRAPH
TOLERANCE ENVELOPE
+10%
1.0
0.5
Safe Operating Area
120°C
0
-40
Typical
L
+5%
VNOM
70°C
100
50
0
Ambient Temperature (°C)
150
Output Voltage
Output Power (W)
1.5
oad Line
+2.5%
-2.5%
-7.5%
10
75
50
25
Output Load Current (%)
100
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NME1515SC is 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NME1515SC, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NME1515SC has a toroidal isolation transformer, with no additional insulation between primary and secondary windings of enameled wire.
While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel
(typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited.
We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
RoHS COMPLIANCE INFORMATION
This NME1515SC is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types
are Matte Tin over Nickel Preplate. Both types in this series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NM1515SC.A02 Page 2 of 3
NME1515SC
Isolated 1W Single Output DC/DC Converter
PACKAGE SPECIFICATIONS
RECOMMENDED FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
)0-&4

0.45
(11.48)
PIN CONNECTIONS - 4 PIN SIP
0.236
(6.00)
Pin
Function
1
2
3
4
-VIN
+VIN
-VOUT
+VOUT
NME1515SC
0.022 (0.55)
0.018 (0.45)
XYYWW
3
4
0.022 (0.55)
0.018 (0.45)
0.074 (1.89)
0.109 (2.77)
0.0118 (0.30)
0.0078 (0.20)
2
1
0.181 (4.60)
0.142 (3.60)
TUBE OUTLINE DIMENSIONS
0.393
(10.0)
0.049
(1.25)
0.3
(7.62)
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
Weight: 1.30g
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
Tube length : 20.47 (520mm ±2mm).
Tube Quantity : 35
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NM1515SC.A02 Page 3 of 3