OBSOLETE PRODUCT

HPR10XXC
www.murata-ps.com
1.0 WATT UNREGULATED, SIP DC/DC CONVERTER
FEATURES
■
OBSOLETE PRODUCT
RoHS Compliant
Low Cost
■
Last time buy: August 31, 2014.
Single-in-line
(SIP)
Click HerePackage
For Obsolescence
Notice of February 2014.
■
DESCRIPTION
■
Internal input and output filtering
The HPR10XXC Series uses advanced circuit design and packaging technology to deliver superior reliability and
performance. A 170kHz push-pull oscillator is used in the input stage. Beat-frequency oscillation problems are
reduced when using the HPR10XXC Series with high frequency isolation amplifiers.
Reduced parts count and high efficiency add to the reliability of the HPR10XXC Series. The high efficiency of the
HPR10XXC Series means less internal power dissipation, as low as 190mW. With reduced heat dissipation the
HPR10XXC Series can operate at higher temperatures with no degradation. In addition, the high efficiency of the
HPR10XXC Series means the series is able to offer greater than 13 W/inch3 of output power density. Operation
down to no load will not impact the reliability of the series, although a 1mA minimum load is needed to realize
published specifications.
The HPR10XXC Series provides the user low cost without sacrificing reliability. The use of surface mounted devices
and advanced manufacturing technologies make it possible to offer premium performance and low cost.
Non-Conductive Case
■
High Output Power Density:
13 Watts/Inch3
■
■
Extended Temperature Range:
-25°C to +65°C
■
Efficiency to 72% (Typical)
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
OBSOLETE
Model
HPR1000C
HPR1001C
HPR1004C
HPR1005C
HPR1018C
HPR1022C
HPR1023C
HPR1002C
HPR1003C
HPR1006C
HPR1007C
HPR1008C
HPR1009C
HPR1010C
HPR1011C
HPR1012C
HPR1013C
HPR1014C
HPR1015C
HPR1016C
HPR1017C
HPR1019C
HPR1020C
HPR1021C
Nominal Input
Voltage
VDC
Rated Output
Voltage
VDC
Rated Output
Current
mA
5
5
5
5
24
24
24
5
5
12
12
12
12
12
12
15
15
15
5
12
±12
±15
5
±12
±15
15
±5
5
12
15
±5
±12
±15
5
12
15
200
83
±42
±34
200
±42
±34
67
±100
200
83
67
±100
±42
±34
200
83
67
15
15
24
24
24
±12
±15
12
15
±5
±42
±34
83
67
±100
Input Current
Reflected
Efficiency
No Load
Rated Load Ripple Current
mA
mAp-p
%
33
290
8
68
33
290
8
69
33
285
8
70
33
285
8
70
12
60
15
71
12
58
15
72
12
58
15
72
33
285
8
70
33
285
8
70
18
110
10
70
18
107
10
71
18
107
10
71
18
107
10
71
18
107
10
71
18
107
10
71
15
96
10
70
15
94
10
70
15
94
10
71
15
15
12
12
12
94
94
60
58
58
10
10
15
15
15
71
71
71
72
72
Recommended Alternatives
MER1S0505SC
MER1S0512SC
MEA1D0512SC
MEA1D0515SC
MER1S2405SC
MEA1D2412SC
MEA1D2415SC
NMR102C / MER1S0515SC
NMA0505SC / MEA1D0505SC
NMR106C / MER1S1205SC
NMR107C / MER1S1212SC
NMR108C / MER1S1215SC
NMA1205SC / MEA1D1205SC
NMA1212SC / MEA1D1212SC
NMA1215SC / MEA1D1215SC
MER1S1505SC
MER1S1512SC
MER1S1515SC
MEA1D1505SC
MEA1D1512SC
MEA1D1515SC
MER1S2412SC
MER1S2415SC
MEA1D2405SC
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
TDC_HPR10XXC.D02 Page 1 of 4
HPR10XXC
1.0 WATT UNREGULATED, SIP DC/DC CONVERTER
MECHANICAL
FRONT
VIEW
Notes: All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
RIGHT
SIDE
VIEW
HPR10XXC
PIN PLACEMENT TOLERANCE: ± 0.015"
MATERIAL: Lead material is phosphor bronze; finish is
100-300 micro-inches of matte tin over a barrier layer of
5-40 micro-inches of nickel.
PIN CONNECTIONS
1. +VIN
BOTTOM
VIEW
2. -VIN
4. -VOUT 5. COM*
6. +VOUT
* Common pin not present on
single output models.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
INPUT
Voltage Range
Voltage Rise Time
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Ripple & Noise
Voltage
Temperature Coefficent
REGULATION
Line Regulation
Load Regulation (5V out only)
Load Regulation (All other Models)
GENERAL
Switching Frequency
Frequency Change
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
Fixed Ground
Naval Sheltered
Airborne Uninhabited Fighter
CONDITIONS
MIN
TYP
MAX
UNITS
4.5
5
5.5
VDC
10.8
12
13.2
VDC
13.5
15
16.5
VDC
21.6
24
26.4
VDC
See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters"
60 Hz, 10 Seconds
1000
1000
10
25
2
VISO= 240VAC, 60Hz
100
8.5
1.0
VDC
Vpk
G
pF
µArms
.01
W
%
mVp-p
mVrms
VDC
VDC
VDC
%/Deg C
High Line to Low Line
Rated Load to 1mA Load
Rated Load to 1mA Load
1
10
3
%/%Vin
%
%
Over Line and Load
170
24
2
kHz
%
g
Circuit Stress Method
TA = +25°C
TA = +35°C
TA = +35°C
TA = +35°C
3.8
1.4
685
211
MHr
MHr
kHr
kHr
±5
100
Rated Load, Nominal VIN
BW = DC to 10MHz
BW =10Hz to 2MHz
1mA Load, VOUT = 5V
1mA Load, VOUT = 12V
1mA Load, VOUT = 15V
TEMPERATURE
Specification
Storage
30
7
15
18
-25
-50
+25
+65
+110
°C
°C
* For demonstrated MTTF results reference Reliability Report HPR105
www.murata-ps.com/support
TDC_HPR10XXC.D02 Page 2 of 4
HPR10XXC
1.0 WATT UNREGULATED, SIP DC/DC CONVERTER
TYPICAL PERFORMANCE CURVES
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
VOUT VS LOAD
(5Vout Models)
VOUT VS LOAD
(±5Vout Models)
5.7
5.4
5.5
5.2
VOUT VS LOAD
(12Vout Models)
12.5
5.3
12.3
Vout
Vout
Vout
12.4
5.0
12.2
12.1
5.1
4.8
4.9
4.6
12.0
0
80
40
120
160
11.9
0
Output Current (mA)
20
40
60
0
80
Output Current each load (mA)
VOUT VS LOAD
(±12Vout Models)
VOUT VS LOAD
(15Vout Models)
12.6
40
60
80
VOUT VS LOAD
(±15Vout Models)
16.5
15.9
12.5
16.0
15.7
12.4
15.5
12.3
15.5
Vout
Vout
Vout
20
Output Current each load (mA)
15.0
12.2
15.3
14.5
12.1
15.1
14.0
12.0
14.9
0
10
20
30
40
13.5
0
20
40
60
Output Current each load (mA)
Output Current each load (mA)
EFFICIENCY VS LOAD
OSCILLATION FREQUENCY VS
TEMPERATURE
90
80
0
0.2
0.4
0.6
0.8
1.0
Output Power each load (Watts)
220
Efficiency (%)
Efficiency (%)
75
60
45
30
200
180
160
15
0
0
20
40
60
140
80
% of Rated Load (%)
100
-30
0
30
60
90
Temperature (°C)
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected
to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this
time and temperature range, the integrity of the device’s plastic body will not be compromised and
internal temperatures within the converter will not exceed 175°C. Care should be taken to control
manual soldering limits identical to that of wave soldering.
www.murata-ps.com/support
TDC_HPR10XXC.D02 Page 3 of 4
HPR10XXC
1.0 WATT UNREGULATED, SIP DC/DC CONVERTER
SAFE OPERATING AREA
LOAD CAPACITANCE vs INPUT RISE TIME
(5 Vout models)
600
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
500
400
300
SAFE OPERATING AREA
200
40
30
SAFE OPERATING AREA
20
10
100
0
0
0
5
10
15
20
25
30
35
Rise Time of Input Voltage (mS)
40
45
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
NOTES:
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
1. When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of Hpr10xxC devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steadystate value.
80
70
60
50
SAFE OPERATING AREA
40
0
50
90
Total Load Capacitance (uF)
LOAD CAPACITANCE vs INPUT RISE TIME
(15 Vout models)
60
30
2. For dual output models, total load capacitance is the sum of the
capacitances on the plus and minus outputs.
20
10
0
0
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
HPR 10XX C
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected from Table of Electrical Characteristics
RoHS Compliance
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Internal Power Dissipation.....................................................490mW
Short Circuit Duration......................................................Momentary
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support