OBSOLETE PRODUCT

* LAST TIME BUY: AUGUST 31, 2014. CLICK HERE FOR OBSOLESCENCE NOTICE OF FEBRUARY 2014.
HPR1XXWC Series
www.murata-ps.com
0.75 Watt Single Output DC/DC Converter
OBSOLETE PRODUCT
Last time buy: August 31, 2014.
Click Here
Obsolescence
Notice
oftechnology
February
2014.
The HPR1XXWC
Series For
uses advanced
circuit design and
packaging
to deliver
superior reliabil-
FEATURES

Low Cost
ity and performance. A 170kHz push-pull oscillator is used in the input stage. Beat-frequency oscillation
problems are reduced when using the HPR1XXWC Series with high frequency isolation amplifiers.
Multiple Package Styles

Internal Input and Output

Reduced parts count and high efficiency add to the reliability of the HPR1XXWC Series. The high
efficiency of the HPR1XXWC Series means less internal power dissipation, as low as 190mW.
Filtering

Non-Conductive Case

High Output Power Density: 10 Watts/Inch3

Extended Temperature Range: -25°C to +85°C

With reduced heat dissipation the HPR1XXWC Series can operate at higher temperatures with no
degradation. In addition, the high efficiency of the HPR1XXWC Series means the series is able to offer
greater than 10 W/inch3 of output power density. Operation down to no load will not impact the reliability of the series, although a >1mA minimum load is needed to realize published specifications.
The HPR1XXWC Series provides the user a low cost converter without sacrificing reliability. The use
of surface mounted devices and advanced manufacturing technologies make it possible to offer
premium performance and low cost.
Efficiency to 79%

RoHS Compliant

All specifications are typical at TA = +25°C nominal input voltage unless otherwise specified.
TIME BUY FOR HPR100WC AND HPR109WC ONLY: AUGUST 31, 2014. CLICK HERE FOR OBSOLESCENCE NOTICE
* LAST
OF FEBRUARY 2014.
PRODUCT SELECTION CHART
Model
OBSOLETE
OBSOLETE
*
*
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
HPR100WC
HPR105WC
HPR109WC
HPR101WC
HPR102WC
HPR103WC
HPR104WC
HPR106WC
HPR107WC
HPR108WC
HPR110WC
HPR111WC
HPR112WC
HPR113WC
HPR114WC
HPR115WC
HPR116WC
HPR117WC
HPR118WC
HPR119WC
HPR120WC
HPR121WC
HPR122WC
HPR123WC
Nominal
Input
Voltage
VDC
Rated
Output
Voltage
VDC
Rated
Output
Current
mA
5
5
12
5
5
5
5
12
12
12
12
12
15
15
15
15
15
15
24
24
24
24
24
24
5
±15
±5
12
15
±5
±12
5
12
15
±12
±15
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
150
±25
±75
62
50
±75
±30
150
62
50
±30
±25
150
62
50
±75
±30
±25
150
62
50
±75
±30
±25
Input Current
Reflected
Efficiency
Rated Load
Ripple Current
Typ.
mA
mAp-p
%
20
216
10
69
20
200
5
75
10
88
5
71
20
212
5
70
20
212
5
71
20
218
5
68
20
212
5
68
10
90
5
69
10
81
5
77
10
81
5
77
10
81
5
74
10
81
5
77
8
72
5
69
8
72
5
69
8
72
5
69
8
72
5
69
8
63
5
76
8
63
5
79
8
48
15
65
8
48
15
65
8
45
15
76
8
45
15
69
8
45
15
67
8
45
15
69
No Load
Recommended
Alternatives
NTE0505MC
NTA0515MC
NTA1205MC
NTE0512MC
NTE0515MC
NTA0505MC
NTA0512MC
NTE1205MC
NTE1212MC
NTE1215MC
NTA1212MC
NTA1215MC
-
*Not Recommended for New Designs
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
TDC_HPR1xxWC.D01 Page 1 of 4
HPR1XXWC Series
0.75 Watt Single Output DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at TA = +25°C nominal input voltage unless otherwise specified.
GENERAL
OUTPUT
INPUT
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
4.5
5
5.5
VDC
10.8
12
13.2
VDC
13.5
15
16.5
VDC
21.6
24
26.4
VDC
Voltage Rise Time See Typical Performance Curves & Application Notes: “Capacitive Loading Effects on Start-Up of DC/DC Converters”
OUTPUT
Rated Power
750
mW
Voltage Setpoint Accuracy
Rated Load, Nominal VIN
±5
%
Ripple & Noise
BW = DC to 10MHz
150
200
mVp-p
BW =10Hz to 2MHz
30
40
mVrms
Voltage (Over Input Voltage Range) 1mA to Rated Current, VOUT = 5V
4.75
7
VDC
1mA to Rated Current, VOUT = 12V
11.40
15
VDC
1mA to Rated Current, VOUT = 15V
14.25
18
VDC
Temperature Coefficent
.01
.05
%/ °C
REGULATION
Load Regulation (All other modes)
Rated Load to 1mA Load
3
%
GENERAL
ISOLATION
Rated Voltage
750
VDC
Test Voltage
60 Hz, 10 Seconds
750
Vrms
Resistance
10
G
Capacitance
25
100
pF
Leakage Current
VISO= 240VAC, 60Hz
2
8.5
Arms
Switching Frequency
170
kHz
Frequency Change
Over Line and Load
24
%
Package Weight
3
g
MTTF per MIL-HDBK-217, Rev. F*
Circuit Stress Method
Ground Benign
TA = +25°C
7.9
MHr
Fixed Ground
TA = +35°C
1.9
MHr
Naval Sheltered
TA = +35°C
1.2
MHr
Airborne Uninhabited Fighter
TA = +35°C
300
kHr
TEMPERATURE
Specification
-25
+25
+85
°C
Operation
-40
+100
°C
Storage
-40
+110
°C
SOLDERING INFORMATION
The surface mount versions of the HPR1XXWC series are designed for SMT reflow soldering.
During this standard process devices should be heated at a rate not to exceed 3 degrees C per
second. The peak reflow temperature is 260 degrees C. The device should not be exposed to the
peak temperature ±10 degrees C for more than 12 seconds. The cool down rate for this device
should not exceed 3 degrees C per second.
www.murata-ps.com/support
TDC_HPR1xxWC.D01 Page 2 of 4
HPR1XXWC Series
0.75 Watt Single Output DC/DC Converter
TYPICAL PERFORMANCE CURVES
Specifications are at TA = +25°C nominal input voltage and nominal load.
VOUT VS LOAD
(5Vout Models)
VOUT VS LOAD
(±5Vout Models)
5.7
5.4
5.5
5.2
VOUT VS LOAD
(12Vout Models)
12.5
5.3
12.3
Vout
Vout
Vout
12.4
5.0
12.2
12.1
5.1
4.8
4.9
4.6
12.0
0
80
40
120
160
11.9
0
20
Output Current (mA)
40
60
80
0
VOUT VS LOAD
(±12Vout Models)
80
VOUT VS LOAD
(±15Vout Models)
16.0
15.7
12.4
15.5
12.3
15.5
Vout
Vout
Vout
60
16.5
15.9
12.5
40
Output Current each load (mA)
VOUT VS LOAD
(15Vout Models)
12.6
15.0
12.2
15.3
14.5
12.1
15.1
14.0
12.0
14.9
0
10
20
30
40
13.5
0
20
40
60
80
Output Current each load (mA)
Output Current each load (mA)
EFFICIENCY VS LOAD
OSCILLATION FREQUENCY VS
TEMPERATURE
90
0.2
0
0.4
0.6
0.8
1.0
Output Power each load (Watts)
220
Frequency (KHz)
75
Efficiency (%)
20
Output Current each load (mA)
60
45
30
15
0
20
0
180
160
140
60
40
200
80
-30
100
0
% of Rated Load (%)
30
60
90
Temperature (°C)
SAFE OPERATING AREA
LOAD CAPACITANCE vs INPUT RISE TIME
(5 Vout models)
600
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
500
400
300
SAFE OPERATING AREA
200
40
30
SAFE OPERATING AREA
20
10
100
0
0
0
5
10
15
20
25
30
35
Rise Time of Input Voltage (mS)
40
45
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
NOTES:
1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the
output voltage of HPR1XXC devices is guaranteed to be within 95% of its steady-state value
within 100 milliseconds after the input voltage has reached 95% of its steady-state value.
2.) For dual output models, total load capacitance is the sum of the capacitances on the
plus and minus outputs.
80
70
60
50
SAFE OPERATING AREA
40
0
50
90
Total Load Capacitance (uF)
LOAD CAPACITANCE vs INPUT RISE TIME
(15 Vout models)
60
30
20
10
0
0
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
www.murata-ps.com/support
TDC_HPR1xxWC.D01 Page 3 of 4
HPR1XXWC Series
0.75 Watt Single Output DC/DC Converter
MECHANICAL
PACKAGE/PINOUT “W”
SMD PACKAGE
0.785±0.010"
(19.94±0.25)
14 13
11 10 9 8
0.695±0.015"
(17.65±0.38)
0.525±0.010"
(13.34±0.25)
TOP VIEW
1 2 3 4 5 6 7
0.375±0.005"
(9.52±0.13)
0.015±0.005"
(0.38±0.13)
SIDE VIEW
0.020±0.002"
(0.51±0.05)
0.100±0.010"
(2.54±0.25)
BOTTOM VIEW
0.014±0.002"
(0.36±0.05)
PIN CONNECTIONS
PIN#
1
2
3
4
5
6
SINGLES
+VIN
-VIN
NC
NC
-VOUT
NC
DUALS
PIN#
+VIN
-VIN
NC
NC
-VOUT
Common
7
8
9
10
11
13
14
.015±.010"
(.38±.26)
NOTES:
SINGLES
DUALS
+VOUT
NC
NC
NC
NC
NC
NC
+VOUT
NC
NC
NC
NC
NC
NC
ABSOLUTE MAXIMUM RATINGS
NC = Do Not Connect.
Duplicate pin functions are internally connected.
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
MATERIAL: Lead material is phosphor bronze; lead
finish is 100-300 microinches of matte tin over a
nickel barrier layer of 5-40 microinches.
ORDERING INFORMATION
HPR 1XX W
Internal Power Dissipation ........................................ 450mW
Short Circuit Duration ................................................ Momentary
C
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected from Table of Electrical Characteristics
Package Option
W = SMD Package
RoHS Compliant Version
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support
TDC_HPR1xxWC.D01 Page 4 of 4