NMUSB202MC www.murata-ps.com Powered Dual Port USB Data Isolator System voltage rail/ External adapter Power Isolated DC-DC Converter LDO Linear Regulator USB SB Pow Power Switch FEATURES Isolated dual powered USB 2.0 compliant Surface mount module USB Data Port from PC/USB Host Data One upstream port, two isolated dowstream ports Automatic switching between low (1.5Mbps) and full speed (12Mbps) Full 500mA available from isolated ports Full Speed USB Isolatorr USB SB Hub Hu Controller NMUSB202MC IIsolated USB Port 1 U 2.0 USB D Device IIsolated USB Port 2 U 2.0 USB D Device Isolation SELECTION GUIDE Order Code1 NMUSB202MC 3kVAC Isolation Voltage ‘Hi Pot Test’ UL60950 recognition pending Medical recognition ANSI/AAMI ES60601-1 pending (2 x MOOPs) Industrial temperature range -40°C to +85°C Short Circuit/overload protected USB ports PRODUCT OVERVIEW The NMUSB202MC is a surface mount module which conveniently provides dual port USB data isolation from a single upstream port with full power (500mA) available from each downstream port. Isolation provides effective breaking of ground loops and immunity to EMI in harsh environments as found in industrial and medical applications. Full speed (12Mbps) and low speed (1.5Mbps) are supported with automatic switching. Input power of 5V is provided by an external ‘adapter’ or system voltage rail. Power surge notification Patents Pending 3D Model available For full details go to www.murata-ps.com/rohs 1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are NMUSB202MC-R7 (23 pieces per reel), or NMUSB202MC-R13 (92 pieces per reel). All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 1 of 8 NMUSB202MC Powered Dual Port USB Data Isolator DC-DC CHARACTERISTICS INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Voltage range Continuous operation 4.5 5 5.5 Units Current (hub inactive) 5V input 70 mA Current (hub active) 0% load 5V input 110 mA Current 100% load 5V input 1.3 A Input reflected ripple current 5V input 31 mA(rms) V OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Downstream voltages 5V output 4.75 5 5.25 V Peak deviation (0-50-0% & 50-100-50% swing) -5 +3 %Vout Settling time 40 400 μs Parameter Conditions Min. Typ. Max. Units Operation Storage Product temperature rise above ambient See derating curve -40 -50 °C 31 85 105 37 Typ. Max. Units Transient response MODULE CHARACTERISTICS TEMPERATURE CHARACTERISTICS 100% Load, Nom VIN, Still Air (measured on tranformer core) ISOLATION CHARACTERISTICS Parameter Conditions Min. Isolation test voltage Resistance Flash tested for 1 second Viso = 1kVDC 3000 20 VAC GΩ GENERAL CHARACTERISTICS Parameter Conditions Min. Leakage current Common mode transient immunity ESD rating 250 VAC 50Hz 1.31 Typ. Max. Units 1.35 μA Rated on model 2000 V Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load, 25°C ambient temperature 600 kHrs Calculated using Telecordia SR-332 calculation model with nominal input voltage at full load, 25°C ambient temperature 3300 kHrs MTTF ABSOLUTE MAXIMUM RATINGS Parameter Conditions Value Short-circuit protection Input voltage Downstream USB 5V Upstream USB 5V supply Continuous 5.5V www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 2 of 8 NMUSB202MC Powered Dual Port USB Data Isolator TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NMUSB202MC data isolator is 100% production tested at its stated isolation voltage. This is 3kVAC for 1 second. The NMUSB202MC series is pending recognition by Underwiters Laboratory for 250 Vrms reinforced insulation. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The NMUSB202MC series is pending recognition ANSI/AAMI ES60601-1 and provides 2 MOOP (means of operator protection) based upon a working voltage of 250 Vrms max., between Primary and Secondary. UL 60950 The NMUSB202MC series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms. FUSING The NMUSB202MC Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. NMUSB202MC - 2.5A All fuses should be UL recognized and rated to at least the maximum allowable DC input voltage. RoHS COMPLIANCE, MSL AND PSL INFORMATION NMUSB202MC is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC as per J-STD-020D.1. The pin termination finish on this product series is Gold with Nickel Pre-plate. The series is backward compatible with Sn/Pb soldering systems. The product has a Moisture Sensitivity Level (MSL) 3. TEMPERATURE DERATING GRAPH NMUSB202MC 6.00 Output Power (W) 5.00 4.00 Still Air 100 lfm 3.00 200 lfm 400 lfm 2.00 1.00 0.00 50 60 70 80 Temperature (°C) www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 3 of 8 NMUSB202MC Powered Dual Port USB Data Isolator EFFICIENCY GRAPH NMUSB202MC 90 80 Efficiency (%) 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 Load (%) EMC FILTERING AND SPECTRA FILTERING The following filter circuit and filter table shows the input filters typically required to meet EN55022 Quasi-Peak Curve A or B. L1 ISOLATOR C2 C1 R1 USB C1 Ceramic capacitor C2 Electrolytic capacitor TO MEET CURVE B Part Number NMUSB202MC C1 10μF L1 10μH C2 470μF R1 0.5Ω NMUSB202MC 100 90 80 70 dBuV 60 50 40 30 20 10 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 4 of 8 NMUSB202MC Powered Dual Port USB Data Isolator APPLICATION NOTES NMUSB202MC is equivalent to one USB hub for dynamic characteristics, verified by the setup in the figure below for worst case USB specification of 5 cascaded hubs. The host PC counts as one hub. Equipment Use Tektronix DPO5034B Scope Scope Firmware 7.2.0 Build 4 TekExpress USB2 1.0.0.65 Framework version 3.0.1.51 Tektronix TPP0500 500MHZ 300V CATII 3.9pF probes Thurlby PL320 HP Elite Desk 800G F6X32ET~ABU HP Compaq DC5800 Keithley 2000 DMM Keithley 2000 DMM Pro Signal PS11116 5M Certified USB cables Newlink USB 4-Port Hubs Integral “Splash Black” USB flash drive (8GB) HP 672652-001 Logitech 810-003656 TektronixUSB test fixture TDSUSBF Signal Qualification HOST PC Full speed HUB 1 Power Supply for NMUSB202MC Remote From Remote Into Vin Measurement Iin Measurement USB Cabling USB Hubs Full Speed Qualifier Mouse for Port 1 Mouse for Port 2 Test Fixture Full speed downstream signal quality test board Full speed HUB 3 Full speed HUB 2 Full speed HUB 4 Oscilloscope NMUSB202MC Full speed qualifier attached to test board Typical Eye Diagram: The ‘eye’ diagram is an indication of adequate data quality after the worst case of five cascaded USB hubs. 3.64 Voltage 3.06 2.48 1.90 1.32 740m 160m -420m -83.33n -66.67n -50n -33.33n -16.67n 0 16.67n 33.33n 50n 66.67n 83.33n Time www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 5 of 8 NMUSB202MC Powered Dual Port USB Data Isolator APPLICATION NOTES Typical Implementation: C1 100μF 10V (low ESR type) Isolated Output USB1 C2 100μF 10V (low ESR type) 1 +5V C1 +5V 3A (system) 2 D3 D+ 4 GND 6 D-(system) 5 4 MURATA LXES2SBAA4-016 D+(system) 1 2 3 VBUS OUT1 13 D-OUT1 12 GND(system) D+OUT1 11 2 D-IN 3 4 6 5 2 GND Isolated Output USB2 GND1(ISO) 10 LED 9 1 VBUS OUT2 8 D-OUT2 7 +5V C2 2 D- D+OUT2 6 3 D+ GND2(ISO) 5 4 GND 4 NMUSB202MC MURATA LXES2SBAA4-016 1 D+IN Isolation 1 +5V 6 5 4 MURATA LXES2SBAA4-016 3 1 2 3 www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 6 of 8 NMUSB202MC Powered Dual Port USB Data Isolator PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS 23.88±0.10 [0.940±0.004] 23.11±0.10 [0.910±0.004] SMA PICKUP POINT SMA PICKUP POINT (TOP OF FERRITE CORE) 13.92±0.47 [0.548±0.019] 14.12±0.45 [0.556±0.018] Pin Function 1 2 3 4 5 6 7 8 9 10 11 12 13 +5V (UPSTREAM) D-IN D+IN GND (UPSTREAM) GND2 (DOWNSTREAM) D+OUT2 D-OUT2 VBUS OUT2 LED PIN GND1 (DOWNSTREAM) D+OUT1 D-OUT1 VBUS OUT1 S SEATING PLANE 3.43±0.28 [0.135±0.011] RECOMMENDED FOOTPRINT DETAILS 0.25±0.27 [0.010±0.011] 3 4 0.25 [0.010] 5 6 7 8 x7 PLACES 1.91 [0.075] 2 21.39±0.25 [0.842±0.010] 21.89±0.27 [0.862±0.011] 21.39 [0.842] 21.89 [0.862] RECOMMENDED ISOLATION BARRIER 17.78 [0.700] 19.10±0.25 [0.752±0.010] 2.29 [0.090] 9 0.25 [0.010] 3.35±0.28 [0.132±0.011] 0.86±0.23 [0.034±0.009] x7 PLACES 1.37 [0.054] 1 3.43 [0.135] 13.61 [0.536] 13 12 11 10 16.15 [0.636] 18.69 [0.736] 21.23 [0.836] 1.12±0.24 [0.044±0.009] 0.25±0.27 [0.010±0.011] 13.61±0.27 [0.536±0.011] 16.15±0.27 [0.636±0.011] 18.69±0.27 [0.736±0.011] 21.23±0.27 [0.836±0.011] All dimensions in mm (inches), Controlling dimensions is mm. Weight: 11 g www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 7 of 8 NMUSB202MC Powered Dual Port USB Data Isolator TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS REEL PACKAGING DETAILS 50.4 [1.984] MAX# Ø330 [13.000] MAX OR Ø177.8 [7.000] MAX Ø [ 13.5 0.531 Ø 12.8 0.504 ] GOODS ENCLOSURE SECTION LEADER SECTION 400 [15.748] MIN TRAILER SECTION 160 [6.299] MIN 100 [3.937] MIN 1.5 [0.059] MIN ## Ø20.2 [Ø0.795] MIN Carrier tape pockets shown are illustrative only - Refer to carrier tape diagram for actual pocket details. Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) Controlling dimension is mm # Measured at hub ## Six equi-spaced slots on 180mm/7” reel Reel Quantity: 7” - 23 or 13” - 92 [ 4.0 [0.157] Ø2.0 [Ø0.079] MIN +0.004 +0.1 Ø1.5 -0.0 Ø0.059 -0.000 2.0 [0.079] ] #24.5 [0.963] 40.4 [1.591] 44.0±0.3 20.2±0.15 1.75 [0.069] 3° MAX TAPE OUTLINE DIMENSIONS 0.2 ±0.05 COVER TAPE 3° MAX 23.7 [0.932] # 0.6 [0.024] MAX 15.65 [0.616] Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches) Controlling dimension is mm Components shall be orientated within the carrier tape as indicated # Measured on a plane 0.3mm above the bottom pocket Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED 36.0 [1.417] DIRECTION OF UNREELING This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc. www.murata-ps.com/support KDC_NMUSB202MC.A02 Page 8 of 8