to this file: /cf200-a12c

www.murata-ps.com
CF200-A12C
200 Watt High Density AC/DC Power Supply
SELECTION GUIDE
Model Number
Power Output
Main Output
Auxilliary Output
200W
12V
5V
CF200-A12C
INPUT CHARACTERISTICS
Parameter
FEATURES

200W compact high density

Universal AC input with Power Factor
Correction
R
P
E
LET
12V
DESCRIPTION
The CF200-A12C switching power supply utilizes
advanced component and circuit technologies to
deliver one of the industry’s smallest 200 Watt
switchers. Built to meet 1U height considerations,
the U-Frame package measures only 3.30 x
5.00 x 1.50”. The CF200-A12C offers universal
AC input (85-265VAC) with active power factor
correction (PFC) and compliance to worldwide
safety and EMC standards.
75
65
230Vac, full load
115Vac, full load
96
98
Max.
Units
264
63
Vac
Hz
Vac
2.8
25
50
Arms
Apk
%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage

Includes ORing diode for N+1 parallel
operation

International regulatory approvals
Typ.
Ramp up
Ramp down
100Vac
Cold start at 25°C, 115Vac
Cold start at 25°C, 230Vac
T
C
U
OD
Power Factor
O
S
B
O

Ruggedized U-channel construction
Min.
85
47
Inrush Current

Active load current share

RoHS compliant
Conditions
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Rated Input Current
5Vaux
Parameter
Conditions
Voltage Set Point Accuracy
Line and Load Regulation
±1% tolerance
Ripple Voltage & Noise1
20MHz Bandwidth
Output Current
Peak Current
Voltage Set Point Accuracy
Line and Load Regulation
Output Current
Ripple Voltage & Noise1
Min.
Typ.
Max.
Units
±1
Vdc
%
150
mV p-p
12.2
0
16.6
17
5
±2
0
20MHz Bandwidth
A
5
100
Vdc
%
mA
mV p-p
Max.
Units
OUTPUT CHARACTERISTICS
Parameter
Conditions
Remote Sense
Compensates for voltage drops of up to 0.5V between the power supply to the
load. Outputs are internally sensed at output connector if remote sense lines are
opened.
Efficiency
Start-up Delay
Rise Time
Min.
230Vac, full load
115Vac, full load
Output voltage at 90%
Typ.
86
82
%
2.0
20
s
ms
Transient Load Response
For load change of 25% to 75%, at
slew rate of 1A/μs, recovery time less
than 2ms
±5
%
Current Sharing Accuracy
Single wire current share in a N+1
parallel redundant configuration with
OR-ng diodes included in the PSU
±10
%
Hot Swap
Hold-up Time
Overshoot and Undershoot
Available
110Vac, full load
Voltage change at turn-on and turn-off
1
ms
%
16
1 Ripple and noise are measured with 10 μF, in parallel with 0.1 μF ceramic capacitors.
www.murata-ps.com
email: [email protected]
12 Jan 2011
CF200-A12C.A02 Page 1 of 4
CF200-A12C
200 Watt High Density AC/DC Power Supply
GENERAL CHARACTERISTICS
Parameter
Conditions
Storage Temperature Range
Operating Temperature Range
Temperature Coefficient
Cooling
Operating Humidity
Storage Humidity
Altitude
Vibration
Non-condensing
-25
85
Derating linearly to 70°C at -2.5% per 1°C
-5
50
°C
±0.02%/°C
0
70
100W free convection cooling (base plate cooling). 200W continuous forced air cooling, 15CFM min.
Non-condensing
5
95
%
Non-condensing
5
90
Operating 10,000 ft. Non- operating 40,000 ft.
Three orthoganol axes at 1octave/min, 5 min dwell at four major resonances at 0.75G peak, 5Hz to 500Hz
MTBF
Calculated per Bellcore 332, issue 6
specification at Ta=30°C (max junction
temperature for silicon 110°C, capacitors
105°C
Safety Approvals
Input Fuse
Switching Frequency
Weight
Min.
Typ.
Max.
T
C
U
ROD
300
P
E
T
OLE
OBS
UL 60950, CSA C22.2-234, Level 3, EN-60950-1, CE-Mark
Power Supply has internal line fuse: IEC type 4A 250Vac normal BLO
85
510g
Units
Khrs
90
kHz
Max.
Units
PROTECTION CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Over Temperature
Over Voltage
Internal thermostat protects the power supply against excessive temperature. Automatic recovery.
Outputs shut down at 125% of nominal; AC input must be recycled to restore operation.
Over Current
12V output: 110 to 130% of Imax, hiccup mode current limit; automatic recovery. Long-term fail condition
shall not cause damage to PSU.
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Input to Output - Reinforced
3000
Input to Chassis - Basic
1500
Output to Chassis
100
UL 94V-0
Output RTN’s not connected to chassis gnd. 12V RTN and 5V RTN shorted.
Insulation Safety Rating / Test Voltage
Isolation
Material Flammability
Grounding
Max.
Units
Vrms
Vrms
Vdc
CONTROL SIGNALS
Status
Description
Power Good (PG) indication
This signal is used to detect the presence of output voltage. This signal goes high when input power is applied and output voltage is more
than 85% of nominal 12.0 VDC output. Signal type: TTL-compatible, with 2.43K pull-up resistor to +5V.
Enable
+Sense
-Sense
5V AUX
Current Share
Active low input to enable +12VDC output of power supply. For normal operation, short to - Sense.
Positive side of Remote Sense input.
Negative side of Remote Sense input.
+5V standby.
Single-wire current-share connection.
LED Drive
10mA min. When PG is high, Pin 1 of J2 shall go high to illuminate external GREEN LED. When PG is low, Pin 3 of J2 shall go high to
illuminate external YELLOW LED.
www.murata-ps.com
email: [email protected]
12 Jan 2011
CF200-A12C.A02 Page 2 of 4
CF200-A12C
200 Watt High Density AC/DC Power Supply
EMISSIONS AND IMMUNITY
Characteristic
Description
Harmonics
Voltage Fluctuation and Flicker
IEC/EN 61000-3-2
IEC/EN 61000-3-3
Emission Conducted
FCC / EN55022 (CISPR 22)
ESD
IEC/EN 61000-4-2
Electromagnetic Field
IEC/EN 61000-4-3
Electrical Fast Transients/Burst
IEC/EN 61000-4-4
Surge
IEC/EN 61000-4-5
Voltage dips, interruptions
CLASS B, 6 dB Margin – with an external line
filter Type 03SS-P-Q By High Lan or equivalent
4kV contact discharge, Performance Criteria B
8kV operational air discharge, Performance
Criteria B.
T
C
U
ROD
1kV for AC power port, 0.5kV for DC power I/O
and signals port, Performance Criteria B
1kV differential mode and 2kV common mode
3 Vac, 80% AM, 0.08-1kHz, Performance Criteria
A
3 A/m at 50Hz, Performance Criteria A
P
E
T
OLE
RF Conducted Immunity
Magnetic Immunity
Criteria
IEC/EN 61000-4-6
OBS
IEC/EN 61000-4-8
20% reduction for 10ms - Criteria B, 60% for
100ms - Criteria C, 90% reduction for 5000ms Criteria C.
IEC/EN 61000-4-11
OUTPUT CONNECTOR AND SIGNAL SPECIFICATION
PIN
J1 : Molex 26-48-1055
PIN
J6 : MOLEX 26-60-4100
1
3
5
Chassis
Neutral
Phase
PIN
1
2
3
J2 : LED (mating connector optional)
DC OK LED
common LED
DC FAIL LED
PIN
1
2
3
J3, J4 : FAN (mating connector optional)
+12V
+12V RTN
Fan fail signal
1
2
3
4
5
6
7
8
9
10
+12V/RTN
+12V/RTN
+12V/RTN
+12V/RTN
+12V/RTN
+12V
+12V
+12V
+12V
+12V
PIN
1
2
3
4
5
6
7
8
J5 : AMP 640456-8
Power good (PG)
Enable
+ Sense
- Sense
5V standby
C.S.
Fan 1 fail signal to J3-3
Fan 2 fail signal to J4-3
www.murata-ps.com
email: [email protected]
12 Jan 2011
CF200-A12C.A02 Page 3 of 4
CF200-A12C
200 Watt High Density AC/DC Power Supply
MECHANICAL DIMENSIONS
MOUNTING HOLES
(M3, 4 PLACES)
127.00
8.26
109.22
57.15
83.82
13.34
T
C
U
ROD
SIDE MOUNTING HOLES
(M3, 4 PLACES)
CL
P
E
T
E
33.10
L
O
S
B
O
38.10
117.00
MAX. COMPNENT HEIGHT
39.60
MOLEX 26-48-1055
1
J1
1
0
INPUT
MOLEX 26-60-4100
+12V OUTPUT
J6
LED
J2
FAN1 J3
1
1
J5
1
J4
1
FAN2
AMP 640456-3
3 PLACES
AMP 640456-8
SIGNALING
Dimensions: 127mm x 84mm x 39.6mm
MATING CONNECTORS
Connector
Housing
Crimp terminal
J1
J2, J3, J4
J5
J6
Molex 09-50-3051 (1x)
Amp 1375820-3 (1x)
Amp 1375820-8 (1x)
Molex 09-50-3101 (1x)
Molex 08-52-0113 (3x)
Amp 1375819-1 (3x)
Amp 1375819-1 (8x)
Molex 08-52-0113 (10x)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2010 Murata Power Solutions, Inc.
www.murata-ps.com/locations
email: [email protected]
12 Jan 2011
CF200-A12C.A02 Page 4 of 4