www.murata-ps.com CF200-A12C 200 Watt High Density AC/DC Power Supply SELECTION GUIDE Model Number Power Output Main Output Auxilliary Output 200W 12V 5V CF200-A12C INPUT CHARACTERISTICS Parameter FEATURES 200W compact high density Universal AC input with Power Factor Correction R P E LET 12V DESCRIPTION The CF200-A12C switching power supply utilizes advanced component and circuit technologies to deliver one of the industry’s smallest 200 Watt switchers. Built to meet 1U height considerations, the U-Frame package measures only 3.30 x 5.00 x 1.50”. The CF200-A12C offers universal AC input (85-265VAC) with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. 75 65 230Vac, full load 115Vac, full load 96 98 Max. Units 264 63 Vac Hz Vac 2.8 25 50 Arms Apk % OUTPUT VOLTAGE CHARACTERISTICS Output Voltage Includes ORing diode for N+1 parallel operation International regulatory approvals Typ. Ramp up Ramp down 100Vac Cold start at 25°C, 115Vac Cold start at 25°C, 230Vac T C U OD Power Factor O S B O Ruggedized U-channel construction Min. 85 47 Inrush Current Active load current share RoHS compliant Conditions Input Voltage Operating Range Input Frequency Turn-on Input Voltage Turn-off Input Voltage Maximum Rated Input Current 5Vaux Parameter Conditions Voltage Set Point Accuracy Line and Load Regulation ±1% tolerance Ripple Voltage & Noise1 20MHz Bandwidth Output Current Peak Current Voltage Set Point Accuracy Line and Load Regulation Output Current Ripple Voltage & Noise1 Min. Typ. Max. Units ±1 Vdc % 150 mV p-p 12.2 0 16.6 17 5 ±2 0 20MHz Bandwidth A 5 100 Vdc % mA mV p-p Max. Units OUTPUT CHARACTERISTICS Parameter Conditions Remote Sense Compensates for voltage drops of up to 0.5V between the power supply to the load. Outputs are internally sensed at output connector if remote sense lines are opened. Efficiency Start-up Delay Rise Time Min. 230Vac, full load 115Vac, full load Output voltage at 90% Typ. 86 82 % 2.0 20 s ms Transient Load Response For load change of 25% to 75%, at slew rate of 1A/μs, recovery time less than 2ms ±5 % Current Sharing Accuracy Single wire current share in a N+1 parallel redundant configuration with OR-ng diodes included in the PSU ±10 % Hot Swap Hold-up Time Overshoot and Undershoot Available 110Vac, full load Voltage change at turn-on and turn-off 1 ms % 16 1 Ripple and noise are measured with 10 μF, in parallel with 0.1 μF ceramic capacitors. www.murata-ps.com email: [email protected] 12 Jan 2011 CF200-A12C.A02 Page 1 of 4 CF200-A12C 200 Watt High Density AC/DC Power Supply GENERAL CHARACTERISTICS Parameter Conditions Storage Temperature Range Operating Temperature Range Temperature Coefficient Cooling Operating Humidity Storage Humidity Altitude Vibration Non-condensing -25 85 Derating linearly to 70°C at -2.5% per 1°C -5 50 °C ±0.02%/°C 0 70 100W free convection cooling (base plate cooling). 200W continuous forced air cooling, 15CFM min. Non-condensing 5 95 % Non-condensing 5 90 Operating 10,000 ft. Non- operating 40,000 ft. Three orthoganol axes at 1octave/min, 5 min dwell at four major resonances at 0.75G peak, 5Hz to 500Hz MTBF Calculated per Bellcore 332, issue 6 specification at Ta=30°C (max junction temperature for silicon 110°C, capacitors 105°C Safety Approvals Input Fuse Switching Frequency Weight Min. Typ. Max. T C U ROD 300 P E T OLE OBS UL 60950, CSA C22.2-234, Level 3, EN-60950-1, CE-Mark Power Supply has internal line fuse: IEC type 4A 250Vac normal BLO 85 510g Units Khrs 90 kHz Max. Units PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Over Temperature Over Voltage Internal thermostat protects the power supply against excessive temperature. Automatic recovery. Outputs shut down at 125% of nominal; AC input must be recycled to restore operation. Over Current 12V output: 110 to 130% of Imax, hiccup mode current limit; automatic recovery. Long-term fail condition shall not cause damage to PSU. ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Input to Output - Reinforced 3000 Input to Chassis - Basic 1500 Output to Chassis 100 UL 94V-0 Output RTN’s not connected to chassis gnd. 12V RTN and 5V RTN shorted. Insulation Safety Rating / Test Voltage Isolation Material Flammability Grounding Max. Units Vrms Vrms Vdc CONTROL SIGNALS Status Description Power Good (PG) indication This signal is used to detect the presence of output voltage. This signal goes high when input power is applied and output voltage is more than 85% of nominal 12.0 VDC output. Signal type: TTL-compatible, with 2.43K pull-up resistor to +5V. Enable +Sense -Sense 5V AUX Current Share Active low input to enable +12VDC output of power supply. For normal operation, short to - Sense. Positive side of Remote Sense input. Negative side of Remote Sense input. +5V standby. Single-wire current-share connection. LED Drive 10mA min. When PG is high, Pin 1 of J2 shall go high to illuminate external GREEN LED. When PG is low, Pin 3 of J2 shall go high to illuminate external YELLOW LED. www.murata-ps.com email: [email protected] 12 Jan 2011 CF200-A12C.A02 Page 2 of 4 CF200-A12C 200 Watt High Density AC/DC Power Supply EMISSIONS AND IMMUNITY Characteristic Description Harmonics Voltage Fluctuation and Flicker IEC/EN 61000-3-2 IEC/EN 61000-3-3 Emission Conducted FCC / EN55022 (CISPR 22) ESD IEC/EN 61000-4-2 Electromagnetic Field IEC/EN 61000-4-3 Electrical Fast Transients/Burst IEC/EN 61000-4-4 Surge IEC/EN 61000-4-5 Voltage dips, interruptions CLASS B, 6 dB Margin – with an external line filter Type 03SS-P-Q By High Lan or equivalent 4kV contact discharge, Performance Criteria B 8kV operational air discharge, Performance Criteria B. T C U ROD 1kV for AC power port, 0.5kV for DC power I/O and signals port, Performance Criteria B 1kV differential mode and 2kV common mode 3 Vac, 80% AM, 0.08-1kHz, Performance Criteria A 3 A/m at 50Hz, Performance Criteria A P E T OLE RF Conducted Immunity Magnetic Immunity Criteria IEC/EN 61000-4-6 OBS IEC/EN 61000-4-8 20% reduction for 10ms - Criteria B, 60% for 100ms - Criteria C, 90% reduction for 5000ms Criteria C. IEC/EN 61000-4-11 OUTPUT CONNECTOR AND SIGNAL SPECIFICATION PIN J1 : Molex 26-48-1055 PIN J6 : MOLEX 26-60-4100 1 3 5 Chassis Neutral Phase PIN 1 2 3 J2 : LED (mating connector optional) DC OK LED common LED DC FAIL LED PIN 1 2 3 J3, J4 : FAN (mating connector optional) +12V +12V RTN Fan fail signal 1 2 3 4 5 6 7 8 9 10 +12V/RTN +12V/RTN +12V/RTN +12V/RTN +12V/RTN +12V +12V +12V +12V +12V PIN 1 2 3 4 5 6 7 8 J5 : AMP 640456-8 Power good (PG) Enable + Sense - Sense 5V standby C.S. Fan 1 fail signal to J3-3 Fan 2 fail signal to J4-3 www.murata-ps.com email: [email protected] 12 Jan 2011 CF200-A12C.A02 Page 3 of 4 CF200-A12C 200 Watt High Density AC/DC Power Supply MECHANICAL DIMENSIONS MOUNTING HOLES (M3, 4 PLACES) 127.00 8.26 109.22 57.15 83.82 13.34 T C U ROD SIDE MOUNTING HOLES (M3, 4 PLACES) CL P E T E 33.10 L O S B O 38.10 117.00 MAX. COMPNENT HEIGHT 39.60 MOLEX 26-48-1055 1 J1 1 0 INPUT MOLEX 26-60-4100 +12V OUTPUT J6 LED J2 FAN1 J3 1 1 J5 1 J4 1 FAN2 AMP 640456-3 3 PLACES AMP 640456-8 SIGNALING Dimensions: 127mm x 84mm x 39.6mm MATING CONNECTORS Connector Housing Crimp terminal J1 J2, J3, J4 J5 J6 Molex 09-50-3051 (1x) Amp 1375820-3 (1x) Amp 1375820-8 (1x) Molex 09-50-3101 (1x) Molex 08-52-0113 (3x) Amp 1375819-1 (3x) Amp 1375819-1 (8x) Molex 08-52-0113 (10x) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2010 Murata Power Solutions, Inc. www.murata-ps.com/locations email: [email protected] 12 Jan 2011 CF200-A12C.A02 Page 4 of 4