Datasheet

Thermoelectric Cooling Solutions
TO308.1MC06030xx
Performance Parameters
Mounted TEC
Type
ΔTmax
K
Qmax
W
Imax
A
Umax
V
Rt
K/W
H
mm
1MC06-030-xx (n=30)
1MC06-030-05
68
6.4
3.0
1.6
1MC06-030-08
70
4.4
2.1
1MC06-030-10
70
3.6
1.8
1MC06-030-12
71
3.1
1.5
2.3
1MC06-030-15
72
2.5
1.2
2.6
1.9
3.7
0.41
2.1
Performance data is specified at 300K, vacuum (thermal resistance incl.)
Dimensions
Manufacturing options
A. Header material:
CRS - Cold Rolled Steel
D. TEC Ceramics Material:
1.Pure Al2O3(100%) - used by default
2.Alumina (Al2O3- 96%)
F. Thermistor (optional)
Can be mounted to cold side
ceramics edge.
3.Aluminum Nitride (AlN)
B. Header surface finish:
Au plaiting (base and pins)
G. Thermistor mounting:
E. TEC Cold Side Finish:
Epoxy gluing
1. Blank ceramics (not metallized)
C. TEC to Header mounting:
Solder 206 (Tmelt =206°C,
Sn-Ag-In-Cu, flux-free process)
2. Metallized (Au plaiting)
3. Metallized and pre-tinned
(various solder for pre-tinning available)
H. Pinout configuration:
the drawing contains standard
pinout, can be revised by
request)
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 1 of 8
Thermoelectric Cooling Solutions
1MC06-030-05
Performance Data
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-030-05
68
6.4
3.1
3.7
1MC06-030-05
70
7.0
3.1
4.1
Note: Performance data is specified at optimal heatsink. TO-3 Header thermal resistance is included into estimations. Use
TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
1MC06-030-08
Performance Data
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-030-08
70
4.4
2.0
3.7
1MC06-030-08
73
4.8
2.0
4.1
Note: Performance data is specified at optimal heatsink. TO-3 Header thermal resistance is included into estimations. Use
TECCad Software for estimations under different conditions.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 2 of 8
Thermoelectric Cooling Solutions
1MC06-030-10
Performance Data
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-030-10
70
3.6
1.6
3.7
1MC06-030-10
74
4.0
1.6
4.1
Note: Performance data is specified at optimal heatsink. TO-3 Header thermal resistance is included into estimations. Use
TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
1MC06-030-12
Performance Data
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-030-12
71
3.09
1.4
3.7
1MC06-030-12
74
3.37
1.4
4.1
Note: Performance data is specified at optimal heatsink. TO-3 Header thermal resistance is included into estimations. Use
TECCad Software for estimations under different conditions.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 3 of 8
Thermoelectric Cooling Solutions
1MC06-030-15
Performance Data
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-030-15
72
2.5
1.1
3.7
1MC06-030-15
74
2.8
1.1
4.1
Note: Performance data is specified at optimal heatsink. TO-3 Header thermal resistance is included into estimations. Use
TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
Application Tips
1. Never heat up the sub-assembly more than 200˚C.
2. Never use the sub-assembly without an attached
heat sink. Header is NOT a heatsink by itself.
3. Connect TE cooler to DC power supply according
to specified polarity.
4. Do not apply current/voltage higher than specified
max values
Mounting to TEC cold side
Mounting to the
cold side
1. Soldering of object to be cooled.
Method suitable for a TE module with the metallized cold side
(Ordering Options. Item E). Soldering requires careful
TEC
procedures:
A. Never overheat TEC (Application Tips. Item 1).
B. Use solder with melting point less than 200ºC.
2. Gluing of object to be cooled.
Method available by glues with good thermoconductive
properties. Not recommended for high vacuum applications
and long operations at high temperature.
TO-3 8pin header
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 4 of 8
Thermoelectric Cooling Solutions
Sub-assembly Overview
TO-3 8pin Header
Thermistor ( optional)
NTC type, 2.2kOhm or 10kOhm
Thermoelectric Cooler
1MC06-030-XX
TEC to Header Mounting
by hi-temp. soldering
(Lead-Free Solder 206,
Sn-Ag-In-Cu, Tmelt=206ºC)
TE Cooler Internal Solder
(Lead-Free Solder 230,
Sn-Sb, Tmelt=230ºC)
Flexible pinout for TEC
and thermistor
Header Pins with nailheads
for WB
Laser Labeling is available
for TO-3 header (optional)
CRS Material
TO-3 8pin Header Drawing
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 5 of 8
Thermoelectric Cooling Solutions
Additional Options for TEC
TEC Polarity
TEC Polarity can be modified by request. The
specified polarity in this datasheet is typical.
It can be reversed in accordance to Customer
application requirements.
-
+
+
Standard polarity
-
Reversed polarity
Terminal Wires Options
The wires are of tinned Copper, blank (not isolated)
by default. Various options for isolated wires are
available by request. The available solutions
include isolated wires, isolated color-coded wires,
flexible multicore wires and more.
S t a n d a rd w i re s ,
tinned Copper
Isolated wires
Customized Au Patterns
Customized Au patterns on thermoelectric cooler
cold side are available by request. Selective Pretinning over pattern is also available. Please,
contact RMT Ltd for additional information about
customized Au patterns requirements.
Customized Au pattern
on cold side
Selective pre-tinning
over pattern
TEC Height modification
Standard TEC height can be modified without
performance changes by using ceramics of
different thickness. Standard thermoelectric cooler
height (specified in the datasheet) may be modified
in a range -0.5..+1.0mm for single-stage TEC by
request.
Standard height
M o d i fi e d h e i g h t ,
another ceramics
thickness
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 6 of 8
Thermoelectric Cooling Solutions
Contacts
RMT Ltd. Headquarters
Warshavskoe sh. 46, 115230, Moscow,
Russia
Phone: +7-499-678-2082
Fax: +7-499-678-2083
Web: www.rmtltd.ru
Email: [email protected]
EUROPE/USA - TEC Microsystems GmbH
Schwarzschildstrasse 3, 12489 Berlin,
Germany
Tel. +49 30 6789 3314
Fax+49 30 6789 3315
Web: www.tec-microsystems.com
Email: [email protected]
CHINA - ProTEC Ltd.
深圳市南山区登良路恒裕中心B座207
:+86-755-61596066
真:+86-755-61596036
:518054
Web: www.protecltd.com
Email: [email protected]
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 7 of 8
Thermoelectric Cooling Solutions
Legal Notice
All logos, images, trademarks and product names (collectively Materials) are proprietary to RMT Ltd and/ or any
of its affiliates, or subsidiaries, or other respective owners that have granted RMT Ltd the permission and/or
license to use such Materials. All images are provided by RMT Ltd. and are subjects of copyright protection.
RMT Ltd, TEC Microsystems GmbH and ProTEC Ltd. do not grant a copyright license (express or implied) to
the Recipient, except that Recipient may reproduce the logos, images and text materials in this press-release
without any alteration for non-promotional or editorial purposes only with a written note about materials owner.
Copyright protection warning
Graphic materials and text from this datasheet may not be used commercially without a prior response in
writing on company letterhead and signed by RMT Ltd authority.
Thank you for respecting the intellectual property rights protected by the International Copyright laws.
All Images contain RMT hidden watermark for the immediate proof of their origin.
RMT Ltd.
RMT Image
Hidden Watermark
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2012. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 8 of 8