® MIHW1000 SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety FEATURES ►Reinforced Insulation rated for 300VAC Working Voltage ►I/O-isolation Voltage 4000VACrms ►Industrial & Medical Safety Approval ►Wide 2:1 Input Voltage Range ►Fully regulated Output Voltage ►Low Leakage Current ►Operating Temp. Range –40°C to +85 °C ►Input Filter meets EN 55022, class A and FCC, level A ►Overload Protection ►3 Year Product Warranty PRODUCT OVERVIEW The MINMAX MIHW1000 series is a range of high performance DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is specified for 4000VACrms.The product comes in a small DIP-24 package. All 20 models features wide 2:1 input voltage range and fully regulated output voltage. The MIHW1000 DC/DC converters offer an economical solution for demanding applications in industrial and medical instrumentation requesting a certified supplementary or reinforced insulation system to comply with relative industrial or medical safety standards. Model Selection Guide Model Number MIHW1002 MIHW1003 MIHW1008 MIHW1006 MIHW1007 MIHW1012 MIHW1013 MIHW1018 MIHW1016 MIHW1017 MIHW1022 MIHW1023 MIHW1028 MIHW1026 MIHW1027 MIHW1032 MIHW1033 MIHW1038 MIHW1036 MIHW1037 Input Voltage (Range) Output Voltage VDC VDC 5 12 24 ±12 ±15 5 12 24 ±12 ±15 5 12 24 ±12 ±15 5 12 24 ±12 ±15 5 (4.5 ~ 9) 12 (9 ~ 18) 24 (18 ~ 36) 48 (36 ~ 75) Output Current Input Current Max. Min. @Max. Load @No Load Reflected Ripple Current mA 600 250 125 ±125 ±100 600 250 125 ±125 ±100 600 250 125 ±125 ±100 600 250 125 ±125 ±100 mA 90 37.5 18.8 ±18.8 ±15 90 37.5 18.8 ±18.8 ±15 90 37.5 18.8 ±18.8 ±15 90 37.5 18.8 ±18.8 ±15 mA(typ.) 857 800 800 800 800 338 313 313 313 313 160 151 151 151 151 80 75 75 75 75 mA(typ.) mA (typ.) 40 60 30 30 20 15 10 10 Max. capacitive Load μ F 1000 470 470 220# 220# 1000 470 470 220# 220# 1000 470 470 220# 220# 1000 470 470 220# 220# @Max. Load # For each output E-mail:[email protected] 2014/09/23 REV:5 Tel:886-6-2923150 Page 1 of 4 Efficiency (typ.) % 70 75 76 75 75 74 80 81 80 80 78 83 84 83 83 78 83 84 83 83 ® MIHW1000 SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety Input Specifications Parameter Model Input Surge Voltage (1 sec. max.) Start-Up Threshold Voltage Under Voltage Shutdown Min. -0.7 Typ. 5V Input Models --- Max. 11 12V Input Models -0.7 --- 25 24V Input Models -0.7 --- 50 48V Input Models -0.7 --- 100 5V Input Models 12V Input Models 24V Input Models 48V Input Models 5V Input Models 12V Input Models 24V Input Models 48V Input Models 3.7 4 4.5 8 8.5 9 VDC 15 17 18 30 33 36 ----4 ----8.5 ----17 ----34 ----0.3 A ----2000 mW ----2500 mW Compliance to EN 55022,class A and FCC part 15,class A Reverse Polarity Input Current Short Circuit Input Power Internal Power Dissipation Conducted EMI All Models Unit Output Specifications Parameter Output Voltage Setting Accuracy Output Voltage Balance Line Regulation Load Regulation Conditions Dual Output, Balanced Loads Vin=Min. to Max. Io=25% to 100% 5V Output Models 0-20 MHz Bandwidth Other Output Models Ripple & Noise (20MHz) Transient Recovery Time Transient Response Deviation Temperature Coefficient Over Current Protection Short Circuit Protection 25% Load Step Change Foldback Min. ------------------120 Continuous Typ. --±0.5 ±0.3 ±0.5 75 100 150 ±3 ±0.02 150 Max. ±1.0 ±2.0 ±0.5 ±1.0 100 150 500 ±6 ±0.05 --- Unit %Vnom. % % % mV P-P mV P-P μ sec % %/℃ % Max. --2 --13 Unit VACrms μ A GΩ pF Isolation, Safety Standards Parameter I/O Isolation Voltage (rated) Leakage Current I/O Isolation Resistance I/O Isolation Capacitance Conditions 60 Seconds 240VAC, 60Hz 500 VDC 100KHz, 1V Safety Standards Approvals Min. Typ. 4000 ------10 ----7 cUL/UL60950-1, CSA C22.2 No. 60950-1-03 UL60601-1,CSA C22.2 No.601-1 IEC/EN 60950-1, IEC/EN 60601-1 IEC60950-1 CB report, cUL/UL 60950-1 certificate UL60601-1 UL certificate General Specifications Parameter Conditions Switching Frequency MIL-HDBK-217F@25℃, Ground Benign MTBF(calculated) E-mail:[email protected] 2014/09/23 REV:5 Tel:886-6-2923150 Page 2 of 4 Min. Typ. Max. Unit --- 150 --- KHz 1,000,000 --- --- Hours ® MIHW1000 SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety Environmental Specifications Parameter Conditions Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature Storage Temperature Range Humidity (non condensing) Cooling Lead Temperature (1.5mm from case for 10Sec.) Min. -40 Natural Convection ---50 --Free-Air convection --- Max. +85 Unit ℃ +100 +125 95 ℃ ℃ % rel. H 260 ℃ Power Derating Curve 100 Natural Convection 20LFM Output Power (%) 80 100LFM 60 200LFM 400LFM 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 2 3 4 5 6 7 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. Package Specifications 0.2 [0.008] Pin Connections 3.9 10.5 [0.41] [0.15] Mechanical Dimensions 0.60 [0.024] 12 Bottom View 15 23 20.32 [0.80] 2.54 [0.10] 31.8 [1.25] +Vin +Vin 11 No Pin Common 12 -Vout No Pin 13 +Vout -Vout 15 No Pin +Vout 23 -Vin -Vin 24 -Vin -Vin 5.08 [0.20] 2.0 [0.08] ► All dimensions in mm ► Tolerance: X.X±0.25 Physical Characteristics Case Size Case Material : : 31.8x20.3x10.5mm (1.25x0.8x0.41 inches) Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material Weight : : Copper Alloy with Gold Plate Over Nickel Subplate 16.2g 2014/09/23 REV:5 Tel:886-6-2923150 Page 3 of 4 (inches) (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ► Pin E-mail:[email protected] Dual Output 13 2.54 [0.10] 24 Single Output 1 20.3 [0.80] 11 15.22 [0.60] 1 Pin diameter 0.6 ±0.05 (0.024±0.002) ® MIHW1000 SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μ H) and Cin (220μ F, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + Battery +Vin Lin DC / DC Converter Current Probe Cin +Out -Vin Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μ F ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Resistive Load Copper Strip Scope Cout Cout Resistive Load Scope Copper Strip Technical Notes Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μ F for the 5V input devices and a 4.7μ F for the 12V input devices and 2.2μ F for the 24V and 48V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μ F capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout +Vin DC Power Source Load -Out - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Maximum Capacitive Load The MIHW1000 series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2014/09/23 REV:5 Page 4 of 4