® MIDR03M SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety FEATURES ►3000VAC reinforced Insulation ►Insulation rated for 300VAC Working Voltage ►Medical Safety to UL/CSA/EN/IEC 60601-1 3rd Edition ►2 MOOP rated ►Fully regulated Output Voltage ►Low Leakage Current ►Operating Temp. Range –40°C to +75°C ►Input Filter meets EN 55022,class A and FCC, level A ►Short Circuit Protection ►Small DIP-24 Plastic Package ►3 Years Product Warrant PRODUCT OVERVIEW The MINMAX MIDR03M series is a new range of high isolation DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is specified for 3000VACrms.The product comes in a small DIP-24 package. There are 15 models available for 5V,12V and 24V input voltage and single- or dual-output voltage .The MIDR03M DC/DC converters offer a cost effective solution for applications in industrial controls, medical instrumentation and also in consumer electronics requesting a certified supplementary or reinforced insulation system to comply with industrial or latest medical safety standards. Model Selection Guide Model Number MIDR03-05S05M MIDR03-05S12M MIDR03-05S15M MIDR03-05D12M MIDR03-05D15M MIDR03-12S05M MIDR03-12S12M MIDR03-12S15M MIDR03-12D12M MIDR03-12D15M MIDR03-24S05M MIDR03-24S12M MIDR03-24S15M MIDR03-24D12M MIDR03-24D15M Input Voltage Output Voltage VDC VDC 5 12 15 ±12 ±15 5 12 15 ±12 ±15 5 12 15 ±12 ±15 5 ±10% 12 ±10% 24 ±10% Output Current Input Current Max. capacitive Load Max. @Max. Load @No Load mA 600 250 200 ±125 ±100 600 250 200 ±125 ±100 600 250 200 ±125 ±100 mA(typ.) 1000 960 960 1000 1000 420 400 400 420 420 210 195 195 210 210 mA(typ.) Efficiency (typ.) @Max. Load μ F 470 130 220 # 470 60 220 # 470 40 220 # % 60 62 62 60 60 60 62 62 60 60 60 64 64 60 60 # For each output Input Specifications Parameter Input Voltage Range Input Surge Voltage (1 sec. max.) Model Min. Max. 5V Input Models 4.5 5.5 12V Input Models 10.8 13.2 24V Input Models 21.6 26.4 5V Input Models -0.7 7.5 12V Input Models -0.7 15 24V Input Models -0.7 30 --- 0.5 A --- 2500 mW --- 3000 mW Reverse Polarity Input Current Short Circuit Input Power All Models Internal Power Dissipation Conducted EMI VDC Compliance to EN 55022,class A and FCC part 15,class A E-mail:[email protected] 2014/09/23 REV:2 Unit Tel:886-6-2923150 Page 1 of 4 ® MIDR03M SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety Output Specifications Parameter Conditions Output Voltage Setting Accuracy Output Voltage Balance Min. Typ. Max. Unit --- --- ±4.0 %Vnom. Dual Output, Balanced Loads Vin=Min. to Max. ----- ±2.0 ±0.3 ±4.0 ±0.5 % Line Regulation Load Regulation Io=10% to 100% --- ±0.5 ±1.0 % 50 mV P-P ±0.02 %/℃ Min.Load % No minimum Load Requirement Ripple & Noise 0-20 MHz Bandwidth Temperature Coefficient --- --- --- ±0.01 Short Circuit Protection Continuous Isolation, Safety Standards Parameter Conditions Min. Typ. Max. Unit 60 Seconds 3000 --- --- VACrms 240VAC, 60Hz --- --- 2 μ A I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --- 20 --- pF I/O Isolation Voltage (reinforced) Leakage Current cUL/UL60950-1, CSA C22.2 No. 60950-1-03 Safety Standards UL60601-1,CSA C22.2 No.601-1, IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, 2 MOOP IEC60950-1 CB report, cUL/UL 60950-1 certificate Approvals UL60601-1 UL certificate General Specifications Parameter Conditions Min. Typ. Max. Unit 25 60 --- KHz MIL-HDBK-217F@25℃, Ground Benign 1,000,000 --- --- Hours Conditions Min. Max. Unit Natural Convection -40 +75 ℃ ℃ Switching Frequency MTBF(calculated) Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature --- +95 Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- E-mail:[email protected] 2014/09/23 REV:2 Tel:886-6-2923150 Page 2 of 4 260 ℃ ® MIDR03M SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety Power Derating Curve 100 Natural Convection 20LFM Output Power (%) 80 100LFM 200LFM 60 400LFM 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 We recommend to protect the converter by a slow blow fuse in the input supply line. 3 Other input and output voltage may be available, please contact factory. 4 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 5 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin Single Output 3.8 [0.15] 10.5 [0.41] 1 0.5[0.02] Bottom View 24 23 15 +Vin 2 +Vin +Vin 10 No Pin Common 11 No Pin Common 12 -Vout No Pin 13 +Vout -Vout 15 No Pin +Vout 23 -Vin -Vin 24 -Vin -Vin 20.3 [0.80] 10 11 12 2 15.22 [0.60] 1 Dual Output +Vin 13 2.54 [0.10] 20.32 [0.80] 5.08 [0.20] 2.0 [0.08] 2.54 [0.10] ► All dimensions in mm (inches) 31.8 [1.25] Physical Characteristics Case Size : 31.8x20.3x10.5 mm (1.25x0.80x0.41 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 12.4g E-mail:[email protected] 2014/09/23 REV:2 Tel:886-6-2923150 Page 3 of 4 ► Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ► Pin diameter 0.5 ±0.05 (0.02±0.002) ® MIDR03M SERIES DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μ H) and Cin (220μ F, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + Battery +Vin Lin Current Probe Cin +Out DC / DC Converter -Vin Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33μ F ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load +Out Dual Output DC / DC Converter Com. -Vin Copper Strip Copper Strip +Vin Scope Cout Resistive Load Copper Strip Cout -Out Scope Copper Strip Technical Notes Maximum Capacitive Load The MIDR03M series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 220μ F maximum capacitive load for dual outputs and 470μ F capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 4.7μ F for the 5V input devices and a 2.2μ F for the 12V and 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. recommended to use 1.5μ F capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load -Out +Vin - +Out Dual Output DC / DC Com. Converter DC Power Source To reduce output ripple, it is -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2014/09/23 REV:2 Page 4 of 4