DC/DC CONVERTER 6W, Reinforced Insulation, Medical Safety
FEATURES
►Industrial Standard DIP-24 Package
►Wide 2:1 Input Voltage Range
►Fully Regulated Output Voltage
►I/O Isolation 4000VAC with Reinforced Insulation, rated for 1000VAC
Working Voltage
►Low Leakage Current < 2μA
►Operating Ambient Temp. Range -40℃ to +75℃
►Overload and Short Circuit Protection
►Designed-in Conducted EMI meets EN55022 Class A & FCC Level A
►Medical EMC Standard meets EMI EN55011 and EMS EN60601-1-2
►Medical Safety meets 2xMOOP per 3rd Edition of IEC/EN 60601-1 &
ANSI/AAMI ES60601-1 (Pending)
PRODUCT OVERVIEW
The MINMAX MIHW3000 series is a range of high performance DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is
specified for 4000VACrms.The product comes in a small DIP-24 package. All 12 models features wide 2:1 input voltage range and fully regulated output
voltage.
The MIHW3000 DC/DC converters offer an economical solution for demanding applications in industrial and medical instrumentation requesting a certified
high supplementary or reinforced insulation system to comply with relative industrial or medical safety standards.
Model Selection Guide
Model
Number
MIHW3022
MIHW3023
MIHW3026
MIHW3027
MIHW3032
MIHW3033
MIHW3036
MIHW3037
MIHW3042
MIHW3043
MIHW3046
MIHW3047
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
5
12
±12
±15
5
12
±12
±15
5
12
±12
±15
12
(9 ~ 18)
24
(18 ~ 36)
48
(36 ~ 75)
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
Reflected
Ripple
Current
mA
1000
500
±250
±200
1000
500
±250
±200
1000
500
±250
±200
mA
200
100
±50
±40
200
100
±50
±40
200
100
±50
±40
mA(typ.)
570
641
641
641
278
313
313
313
139
156
156
156
mA(typ.)
mA (typ.)
30
60
20
30
10
15
Max. capacitive
Load
μF
1000
470
220#
220#
1000
470
220#
220#
1000
470
220#
220#
Efficiency
(typ.)
@Max. Load
%
75
78
78
78
77
80
80
80
77
80
80
80
# For each output
Input Specifications
Parameter
Model
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Short Circuit Input Power
Input Filter
Conducted EMI
All Models
E-mail:[email protected]
2015/12/28
REV:13
Tel:886-6-2923150
Page 1 of 4
Min.
-0.7
-0.7
-0.7
Typ.
Max.
Unit
25
--50
--100
--7
8
9
13
15
18
VDC
30
33
36
----8.5
----16
----34
----3000
mW
Internal Pi Type
Compliance to EN55022,class A and FCC part 15,class A
®
MIHW3000 SERIES
DC/DC CONVERTER 6W, Reinforced Insulation, Medical Safety
Output Specifications
Parameter
Conditions
Min.
Output Voltage Setting Accuracy
Typ.
Max.
Unit
---
---
±1.0
%Vnom.
Output Voltage Balance
Dual Output, Balanced Loads
---
±0.5
±2.0
%
Line Regulation
Vin=Min. to Max. @Full Load
---
±0.3
±0.5
%
Load Regulation
Io=25% to 100%
---
±0.5
±1.0
%
5V Output Models
---
75
100
mV P-P
Other Output Models
---
100
150
mV P-P
---
300
500
μsec
---
±3
±6
%
---
±0.02
±0.05
%/℃
120
150
---
%
Ripple & Noise
0-20 MHz Bandwidth
Transient Recovery Time
25% Load Step Change
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Foldback
Short Circuit Protection
Continuous, Automatic Recovery
Isolation, Safety Standards
Parameter
Conditions
Reinforced Insulation, Rated For 60 Seconds
I/O Isolation Voltage
Min.
Typ.
Max.
Unit
4000
---
---
VACrms
300VAC working voltage according to IEC/EN 60601-1
1000VAC working voltage according to IEC/EN 60950-1
Leakage Current
240VAC, 60Hz
---
---
2
μA
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100KHz, 1V
---
7
13
pF
UL/cUL 60950-1, CSA C22.2 No. 60950-1
Safety Standards
ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1
IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition 2xMOOP
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report)
Safety Approvals (Pending)
ANSI/AAMI ES60601-1 2xMOOP recognition (UL certificate), IEC/EN 60601-1 3rd Edition (CB-report)
General Specifications
Parameter
Conditions
Switching Frequency
MTBF(calculated)
Min.
Typ.
Max.
Unit
---
150
---
KHz
MIL-HDBK-217F@25℃, Ground Benign
700,000
Hours
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Conditions
Min.
Max.
Unit
Natural Convection
-40
+75
℃
℃
Case Temperature
---
+95
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Cooling
Natural Convection
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2015/12/28
REV:13
Tel:886-6-2923150
Page 2 of 4
---
®
MIHW3000 SERIES
DC/DC CONVERTER 6W, Reinforced Insulation, Medical Safety
Power Derating Curve
100
Natural
Convection
20LFM
Output Power (%)
80
100LFM
60
200LFM
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature C
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however, they may not meet all specifications listed.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
3.8 12.0 [0.47]
[0.15]
Pin Connections
0.5 [0.02]
Mechanical Dimensions
0.60 [0.024]
20.32 [0.80]
2.54
[0.10]
31.8 [1.25]
+Vin
11
No Pin
Common
12
-Vout
No Pin
13
+Vout
-Vout
15
No Pin
+Vout
23
-Vin
-Vin
24
-Vin
-Vin
13
5.08
[0.20]
2.0
[0.08]
2.54
[0.10]
15
23
Dual Output
+Vin
12
Bottom View
24
Single Output
1
20.3 [0.80]
11
15.22 [0.60]
1
Pin
►All dimensions in mm
►Tolerance: X.X±0.25
(inches)
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
Physical Characteristics
Case Size
:
31.8x20.3x12.0mm (1.25x0.8x0.47 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
18g
E-mail:[email protected]
2015/12/28
REV:13
Tel:886-6-2923150
Page 3 of 4
diameter  0.6 ±0.05 (0.024±0.002)
®
MIHW3000 SERIES
DC/DC CONVERTER 6W, Reinforced Insulation, Medical Safety
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Resistive
Load
Scope
Copper Strip
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Technical Notes
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a
good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μF for the 12V input devices and a 4.7μF for the 24V input devices and a
2.2μF for the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
+Vin
DC Power
Source
Load
-Out
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MIHW3000 series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,
affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data
sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
Air Flow
DUT
Design & Feature Considerations
Conducted and radiated emissions < A
with external coupling capacitor Cio=1 nF < B
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/12/28
REV:13
Page 4 of 4