MA03 SERIES - MINMAX Technology

MA03 SERIES
DC/DC CONVERTER 3W, SIP-Package
FEATURES
►Industrial Standard SIP-7 Package
►Semi-regulated Output Voltage
►Very High Efficiency up to 89%
►High I/O Isolation 1000VDC
►Operating Ambient Temp. Range -40℃ to +95℃
►UL/cUL/IEC/EN 60950-1 Safety Approval
PRODUCT OVERVIEW
The MINMAX MA03 series is a new range of isolated 3W DC/DC-converter modules in a small SIP-package. There are 12 models available with 5V, 12V or
24VDC input. These products have a typical load regulation of 5.0% to 7.0% depending on model.
The MA03 DC/DC converters are a compromise between a more expensive fully regulated converter and a non-regulated converter. They offer the
designer a new solution for many cost critical applications where the output voltage variation has to be kept in a certain limit under all load conditions.
Model Selection Guide
Model
Number
MA03-05S05
MA03-05S09
MA03-05S12
MA03-05S15
MA03-12S05
MA03-12S09
MA03-12S12
MA03-12S15
MA03-24S05
MA03-24S09
MA03-24S12
MA03-24S15
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
5
9
12
15
5
9
12
15
5
9
12
15
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
mA
600
333
250
200
600
333
250
200
600
333
250
200
mA
12
6
4.5
3
12
6
4.5
3
12
6
4.5
3
mA(typ.)
723
689
701
686
298
285
284
281
152
147
146
147
mA(typ.)
50
40
30
Load
Regulation
Max. capacitive
Load
% (max.)
8
7
7
6
6
5
4.5
4
5.8
4.8
4.3
3.5
μF
Efficiency
(typ.)
@Max. Load
220
220
220
%
83
87
85.5
87.5
84
87.5
88
89
82
85
85.5
85
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Input Voltage Range
Input Filter
Model
Min.
Typ.
Max.
5V Input Models
-0.7
---
9
12V Input Models
-0.7
---
18
24V Input Models
-0.7
---
30
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
24V Input Models
21.6
24
26.4
All Models
Unit
VDC
Internal Capacitor
Output Specifications
Conditions
Min.
Typ.
Max.
Unit
Line Regulation
Parameter
For Vin Change of 1%
---
±1.01
±1.2
%
Load Regulation
Io=20% to 100%
Ripple & Noise
0-20 MHz Bandwidth
Temperature Coefficient
Short Circuit Protection
---
---
100
mV P-P
---
±0.01
±0.02
%/℃
0.5 Second Max., Automatic Recovery
E-mail:[email protected]
2015/07/31 REV:6
See Model Selection Guide
Tel:886-6-2923150
Page 1 of 4
MA03 SERIES
DC/DC CONVERTER 3W, SIP-Package
General Specifications
Parameter
I/O Isolation Voltage
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1000
---
---
VDC
1 Second
1200
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
60
120
pF
---
60
---
KHz
Switching Frequency
MTBF (calculated)
Safety Approvals
MIL-HDBK-217F@25℃, Ground Benign
2,000,000
UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report)
Hours
Environmental Specifications
Parameter
Conditions
Min.
Max.
Unit
Natural Convection
-40
+85
℃
Case Temperature
---
+100
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Operating Ambient Temperature Range
(See Power Derating Curve)
Cooling
Natural Convection
Lead Temperature (1.5mm from case for 10Sec.)
---
Output Voltage(%)
Output Voltage Tolerance
+20%
+20%
+15%
+15%
+10%
+10%
Max.
+5%
+5%
Typ.
Vnom
Vnom
Min.
-5%
-5%
-10%
0%
20%
40%
60%
-10%
100%
80%
Output Load Current (%)
Power Derating Curve
100
Natural
Convection
20LFM
Output Power (%)
80
400LFM
60
40
20
0
~
-40
50
60
70
80
Ambient Temperature C
E-mail:[email protected]
2015/07/31 REV:6
Tel:886-6-2923150
Page 2 of 4
90
100
110
MA03 SERIES
DC/DC CONVERTER 3W, SIP-Package
Notes
1
2
3
4
5
6
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
however they may not meet all specifications listed.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
[0.13]
3.2
0.5 [0.02]
10.2 [0.40]
19.5 [0.77]
Pin
Function
1
+Vin
2
-Vin
4
-Vout
5
No Pin
6
+Vout
0.5
[0.02]
2.4
[0.09]
2.54
5.08
2X2.54
[0.10]
[0.20]
[2X0.10]
18.5 [0.73]
4
5
6
0.50
[0.02]
0.25 [0.01]
2
1.3 [0.05]
1
7.6 [0.30]
Bottom View
Physical Characteristics
Case Size
:
19.5x7.6x10.2mm (0.77x0.30x0.40 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Alloy 42
Weight
:
2.2g
E-mail:[email protected]
2015/07/31 REV:6
Tel:886-6-2923150
Page 3 of 4
►All dimensions in mm
►Tolerance: X.X±0.25
(inches)
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pins ±0.05(±0.002)
MA03 SERIES
DC/DC CONVERTER 3W, SIP-Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
Technical Notes
Maximum Capacitive Load
The MA03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 220μF maximum capacitive load for devices. The maximum capacitance can be
found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω
at 100 KHz) capacitor of a 2.2μF for the 5V input devices, a 1.0μF for the 12V input devices and a 0.47μF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.0μF capacitors at the output.
+
+Vin
-
+Out
Single Output
DC / DC
Converter
DC Power
Source
-Vin
Cout
Load
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/07/31 REV:6
Page 4 of 4