MKE20-HI SERIES - MINMAX Technology

®
MKE20-HI SERIES
DC/DC CONVERTER 20W, Ultra-High I/O Isolation, 2"×1" Package
FEATURES
►Industrial Standard 2" X 1" Package
►Wide 2:1 Input Voltage Range
►Fully Regulated Output Voltage
►Ultra-high I/O Isolation 8000VDC with Reinforced Insulation
►Common Mode Transient Immunity: 15KV/us
►Qualified for IGBT and High Isolation Applications
►Operating Temp. Range -40°C to +80°C
►No Min. Load Requirement
►Overload/Voltage and Short Circuit Protection
►UL/cUL/IEC/EN 60950-1 Safety Approval (Pending)
PRODUCT OVERVIEW
The MINMAX MKE20-HI series is a new range of isolated 20W DC/DC converter modules in 2"×1" package which feature a wide input range, fully
regulated output and Ultra-Hi I/O Isolation voltage rated for 8000VDC with reinforced insulation. A very high common mode transient immunity with 15KV/us
qualifies these product for IGBT driver applications. Further features include overload protection, short circuit protection and no min. load requirement as
well. There are 15 Models available for 12, 24 and 48VDC input. These converters offer a cost-effective solution for wind turbine, solar panel, transporation
systems, industrial control equipments and some IGBT driver applications where a very high I/O-isolation is required.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MKE20-12S05HI
MKE20-12S051HI
MKE20-12S12HI
MKE20-12D12HI
MKE20-12D15HI
MKE20-24S05HI
MKE20-24S051HI
MKE20-24S12HI
MKE20-24D12HI
MKE20-24D15HI
MKE20-48S05HI
MKE20-48S051HI
MKE20-48S12HI
MKE20-48D12HI
MKE20-48D15HI
VDC
5
5.1
12
±12
±15
5
5.1
12
±12
±15
5
5.1
12
±12
±15
12
(9 ~ 18)
24
(18 ~ 36)
48
(36 ~ 75)
Output Current
Input Current
Reflected
Over
Max. capacitive
Ripple
Voltage
Load
Max.
@Max. Load
@No Load
Current
Protection
mA
4000
4000
1670
±840
±670
4000
4000
1670
±840
±670
4000
4000
1670
±840
±670
mA(typ.)
1961
2000
1897
1888
1882
969
988
948
933
941
479
489
474
477
471
mA (typ.)
mA(typ.)
VDC
6.2
6.2
15
±15
±18
6.2
6.2
15
±15
±18
6.2
6.2
15
±15
±18
20
100
15
50
10
30
Efficiency
(typ.)
@Max. Load
μF
6800
1160
590#
380#
6800
1160
590#
380#
6800
1160
590#
380#
%
85
85
88
89
89
86
86
88
90
89
87
87
88
88
89
# For each output
Input Specifications
Parameter
Input Surge Voltage (100 ms max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Start Up Time
Input Filter
Power Up
E-mail:[email protected]
2015/05/22
P2
Model
12V Input Models
24V Input Models
48V Input Models
Min.
-0.7
-0.7
-0.7
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
Nominal Vin and Constant Resistive Load
All Models
---------------
Tel:886-6-2923150
Page 1 of 5
Typ.
Max.
25
--50
--100
----9
--18
--36
7.5
--15
--33
----30
Internal Pi Type
Unit
VDC
ms
®
MKE20-HI SERIES
DC/DC CONVERTER 20W, Ultra-High I/O Isolation, 2"×1" Package
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Conditions
Min.
Typ.
----Dual Output, Balanced Loads
----Vin=Min. to Max. @Full Load
----Single Output
----Io=0% to 100%
Dual Output
----No minimum Load Requirement
0-20 MHz
5V & 5.1Vo
Measured with a
--50
Bandwidth
12V, ±12V, ±15Vo
MLCC : 4.7uF
--100
----25% Load Step Change(2)
--±3
----Hiccup
--150
Hiccup Mode 0.7 Hz typ. Automatic Recovery
Load Regulation
Minimum Load
Ripple & Noise
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Max.
±1.0
±2.0
±0.5
±0.5
±1.0
Unit
%Vnom.
%
%
%
%
----300
±5
±0.02
---
mV P-P
mV P-P
μsec
%
%/℃
%
Isolation, Safety Standards
Parameter
I/O Isolation Voltage
Conditions
Min.
Typ.
Max.
Unit
Rated for 60 seconds
4200
---
---
VACrms
Tested for 1 second
8000
---
---
VDC
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100KHz, 1V
---
---
60
pF
15
---
---
KV/μs
Max.
-----
Unit
KHz
Hours
Common Mode Transient Immunity
UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1(CB-report)
Safety Approvals (pending)
General Specifications
Parameter
Switching Frequency
MTBF(calculated)
Conditions
MIL-HDBK-217F@25℃, Ground Benign
Min.
--TBD
Typ.
285
---
Environmental Specifications
Parameter
Conditions
Operating Ambient Temperature Range
Natural Convection (6)
Nominal Vin, Load 100% Inom.
(for Power Derating see relative Derating Curves)
Min.
Max.
MKE20-24D12HI
66
MKE20-12D12HI, MKE20-12D15HI, MKE20-24D15HI,
MKE20-48D15HI
62
MKE20-12S12HI, MKE20-24S12HI, MKE20-48S12HI,
MKE20-48D12HI
-40
MKE20-48S05HI, MKE20-48S051HI
58
Unit
℃
55
MKE20-24S05HI, MKE20-24S051HI
51
MKE20-12S05HI, MKE20-12S051HI
℃/W
℃
13.0
48
---
Case Temperature
---
+95
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
---
4000
m
---
260
℃
Thermal Impedance
Natural Convection
Altitude
Cooling
Natural Convection
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2015/05/22
P2
Tel:886-6-2923150
Page 2 of 5
®
MKE20-HI SERIES
DC/DC CONVERTER 20W, Ultra-High I/O Isolation, 2"×1" Package
Power Derating Curve
100
80
Natural
Convection
20LFM
60
40
20
0
~
-40
0
20
40
60
80
100
110
Ambient Temperature C
MKE20-24D12HI
MKE20-12D12HI, MKE20-12D15HI, MKE20-24D15HI, MKE20-48D15HI
100
100
80
80
Natural
Convection
20LFM
60
60
40
40
20
20
0
0
~
-40
Natural
Convection
20LFM
0
20
40
60
80
100
110
~
-40
0
20
60
MKE20-12S12HI, MKE20-24S12HI, MKE20-48S12HI, MKE20-48D12HI
MKE20-48S05HI, MKE20-48S051HI
MKE20-24S05HI, MKE20-24S051HI
MKE20-12S05HI, MKE20-12S051HI
Notes
1
40
Ambient Temperature C
Ambient Temperature C
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3
We recommend to protect the converter by a slow blow fuse in the input supply line.
4
Other input and output voltage may be available, please contact factory.
5
To meet EN61000-4-4 & EN61000-4-5 an external capacitor across the input pins is required.Suggested capacitor:TBD
6
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7
Specifications are subject to change without notice.
E-mail:[email protected]
2015/05/22
P2
Tel:886-6-2923150
Page 3 of 5
80
100
110
®
MKE20-HI SERIES
DC/DC CONVERTER 20W, Ultra-High I/O Isolation, 2"×1" Package
Package Specifications
Mechanical Dimensions
Pin Connections
5.08
[0.20]
5.08
[0.20]
Bottom View
5
4
Pin
Single Output
Dual Output
1
+Vin
+Vin
2
-Vin
-Vin
3
+Vout
+Vout
4
No Pin
Common
5
-Vout
-Vout
50.8 [2.00]
1.00 [ 0.04]
1
45.72 [1.80]
2
12.0
[0.47]
►All
3
dimensions in mm (inches)
►Tolerance: X.X±0.5
10.16
[0.40]
2.54
[0.10]
10.16
[0.40]
25.4 [1.00]
Physical Characteristics
Case Size
:
50.8x25.4x12.0mm (2.0x1.0x0.47 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Tinned Copper
Weight
:
TBD
E-mail:[email protected]
2015/05/22
P2
Tel:886-6-2923150
Page 4 of 5
(X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
►Pin
diameter  1.0 ±0.05 (0.04±0.002)
®
MKE20-HI SERIES
DC/DC CONVERTER 20W, Ultra-High I/O Isolation, 2"×1" Package
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
Current
Probe
Cin
+Out
DC / DC
Converter
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 4.7μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Technical Notes
Overload Protection
To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure overload for an
unlimited duration.
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals.
The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output
overvoltage. The OVP level can be found in the output data.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a good
quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μF for the 12V input devices and a 4.7μF for the 24V input devices and a 2.2μF for
the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 4.7μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
+Vin
DC Power
Source
Load
-Out
-
+Out
Dual Output
Com.
DC / DC
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MKE20-HI series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,
affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/05/22
P2