MAU300 SERIES

MAU300 SERIES
DC/DC CONVERTER 2W, SIP-Package
FEATURES
►SIP Package with Industry Standard Pinout
►Package Dimension:
19.5 x 10.2 x 7.6 mm (0.77”x 0.4”x 0.3”)
►Single and Dual Output Models
►I/O-Isolation 1000 VDC
►Operating Temp. Range -40°C to +85°C
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MAU300 series is a range of 2W DC/DC converters in a small SIP Package featuring an I/O-isolation of 1000VDC. An excellent efficiency
allows an operating temperature range of –40°C to +85°C.
These converters offer an economical solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination,
digital interfaces or for board level power distribution with isolated voltages.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MAU301
MAU302
MAU303
MAU304
MAU305
MAU306
MAU307
MAU311
MAU312
MAU313
MAU314
MAU315
MAU316
MAU317
MAU321
MAU322
MAU323
MAU324
MAU325
MAU326
MAU327
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
VDC
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
Output Current
Input Current
Max.
Min.
@Max. Load
mA
500
400
165
133
±200
±83
±66
500
400
165
133
±200
±83
±66
500
400
165
133
±200
±83
±66
mA
10
8
3
2.5
±4
±1.5
±1
10
8
3
2.5
±4
±1.5
±1
10
8
3
2.5
±4
±1.5
±1
mA(typ.)
452
526
495
499
519
504
501
185
212
200
200
210
201
200
92
108
101
101
105
102
100
@No Load
mA(typ.)
60
30
15
Load
Max. capacitive
Efficiency
Regulation
Load
(typ.)
% (max.)
11
11
7
7
10
7
7
8
8
5
5
8
5
5
8
8
5
5
8
5
5
uF
@Max. Load
470
390#
470
390#
470
390#
%
73
76
80
80
77
79
79
74
78
82
83
79
82
82
74
77
81
82
79
81
82
# For each output
Input Specifications
Parameter
Model
5V Input Models
12V Input Models
24V Input Models
5V Input Models
12V Input Models
24V Input Models
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Reverse Polarity Input Current
Input Filter
Internal Power Dissipation
Typ.
5
12
24
---------
All Models
Tel:886-6-2923150
Page 1 of 4
Max.
5.5
13.2
26.4
9
18
30
0.3
Unit
VDC
650
mW
A
Pi Filter
---
E-mail:[email protected]
2011/12/05 REV:3
Min.
4.5
10.8
21.6
-0.7
-0.7
-0.7
---
---
MAU300 SERIES
DC/DC CONVERTER 2W, SIP-Package
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
Conditions
Min.
-------
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
Typ.
Max.
±1.0
±3.0
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
100
150
--200
--15
±0.01
±0.02
0.5 Second Max.
---------
Over Line, Load & Temp.
Unit
%
%
%
mV P-P
mV P-P
mV rms
%/℃
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1000
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
80
120
pF
50
80
100
KHz
2,000,000
---
---
Hours
I/O Isolation Voltage (rated)
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Input Fuse
5V Input Models
12V Input Models
24V Input Models
1000mA Slow-Blow Type
500mA Slow-Blow Type
200mA Slow-Blow Type
Environmental Specifications
Parameter
Conditions
Min.
Max.
Unit
Ambient
-40
+85
℃
Case Temperature
---
+90
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Operating Temperature Range (with Derating)
Cooling
Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.)
---
Power Derating Curve
100
Natural
convection
80
100LFM
200LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Ripple & Noise measurement bandwidth is 0-20MHz.
3
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
4
All DC/DC converters should be externally fused at the front end for protection.
5
Other input and output voltage may be available, please contact factory.
6
Specifications subject to change without notice.
modules; however they may not meet all specifications listed.
E-mail:[email protected]
2011/12/05 REV:3
Tel:886-6-2923150
Page 2 of 4
MAU300 SERIES
DC/DC CONVERTER 2W, SIP-Package
Package Specifications
Mechanical Dimensions
Pin Connections
0.5 [0.02]
3.2
[0.13]
0.5
[0.02]
2.35
[0.09]
10.2 [0.40]
19.5 [0.77]
2.54 5.08
[0.10] [0.20]
Pin
Single Output
Dual Output
1
+Vin
+Vin
2
-Vin
-Vin
4
-Vout
-Vout
5
No Pin
Common
6
+Vout
+Vout
2X2.54
[2X0.10]
7.6 [0.30]
18.5 [0.73]
Bottom View
2
4
5
6
0.50
[0.02]
0.25 [0.01]
1.3 [0.05]
1
Physical Characteristics
Case Size
:
19.5x7.6x10.2mm (0.77x0.30x0.40 Inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight
:
2.7g
E-mail:[email protected]
2011/12/05 REV:3
Tel:886-6-2923150
Page 3 of 4
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
► Pins ±0.05(±0.002)
MAU300 SERIES
DC/DC CONVERTER 2W, SIP-Package
Test Configurations
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Design & Feature Considerations
Maximum Capacitive Load
The MAU300 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 390uF maximum capacitive load for dual outputs and 470uF capacitive load
for single outputs. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is comended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at
100 KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.5uF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC
Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]