MINMAX MAU123

MAU100 SERIES
DC/DC CONVERTER 1W, SIP-Package
FEATURES
►SIP Package with Industry Standard Pinout
► Package Dimension:
19.5 x 10.2 x 6.1 mm (0.77”x 0.4”x 0.24”) 5V&12V Models
19.5 x 10.2 x 7.1 mm (0.77”x 0.4”x 0.28”) 15V&24V Models
►Single and Dual Output Models
►I/O-Isolation 1000 VDC
►Operating Temp. Range -40°C to +85°C
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MAU100 series is a range of 1W DC/DC converters in a small SIP Package featuring I/O-isolation of 1000VDC.
An excellent efficiency allows an operating temperature range of –40°C to +85°C.
These converters offer an economical solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination,
digital interfaces or for board level power distribution.
Model Selection Guide
Model
Number
MAU101
MAU102
MAU103
MAU104
MAU105
MAU106
MAU107
MAU108
MAU109
MAU111
MAU112
MAU113
MAU114
MAU115
MAU116
MAU117
MAU118
MAU119
MAU151
MAU152
MAU153
MAU154
MAU155
MAU156
MAU121
MAU122
MAU123
MAU124
MAU125
MAU126
MAU127
MAU128
MAU129
Input
Voltage
(Range)
VDC
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
15
(13.5 ~ 16.5)
24
(21.6 ~ 26.4)
E-mail:[email protected]
2013/01/23 REV:4
Output
Voltage
VDC
3.3
5
9
12
15
±5
±9
±12
±15
3.3
5
9
12
15
±5
±9
±12
±15
5
12
15
±5
±12
±15
3.3
5
9
12
15
±5
±9
±12
±15
Output Current
Max.
mA
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
200
84
67
±100
±42
±34
260
200
110
84
67
±100
±56
±42
±34
Tel:886-6-2923150
Page 1 of 4
Min.
mA
5
4
2
1.5
1
±2
±1
±0.8
±0.7
5
4
2
1.5
1
±2
±1
±0.8
±0.7
4
1.5
1
±2
±0.8
±0.7
5
4
2
1.5
1
±2
±1
±0.8
±0.7
Input Current
@Max. Load
mA(typ.)
235
281
260
258
258
278
262
258
258
96
114
106
105
104
113
106
104
105
93
85
85
93
85
85
49
59
54
54
53
58
55
53
53
@No Load
mA(typ.)
30
12
11
7
Load
Regulation
Max. capacitive
Load
% (max.)
10
10
8
7
7
10
8
7
7
8
8
5
5
5
8
5
5
5
8
5
5
8
5
5
8
8
5
5
5
8
5
5
5
µF
220
100#
220
100#
220
100#
220
100#
# For each output
Efficiency
(typ.)
@Max. Load
%
73
71
76
78
78
72
77
78
79
74
73
78
80
80
74
79
81
81
72
79
79
72
80
80
73
71
76
78
79
72
76
79
80
MAU100 SERIES
DC/DC CONVERTER 1W, SIP-Package
Input Specifications
Parameter
Model
5V Input Models
12V Input Models
15V Input Models
24V Input Models
5V Input Models
12V Input Models
15V Input Models
24V Input Models
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Reverse Polarity Input Current
Internal Filter Type
Internal Power Dissipation
All Models
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Min.
-------
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
max. 20MHz Bandwidth
Parameter
60 Seconds
I/O Isolation Capacitance
100KHz, 1V
I/O Isolation Resistance
Min.
Switching Frequency
MTBF (calculated)
5V Input Models
12V Input Models
500mA Slow-Blow Type
200mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Storage Temperature Range
70
2,000,000
100
---
---
100
15V Input Models
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
Tel:886-6-2923150
Page 2 of 4
mV P-P
%/℃
Unit
VDC
MΩ
pF
120
KHz
Hours
24V Input Models
100mA Slow-Blow Type
Max.
Unit
---
+90
℃
-40
---
Cooling
Unit
%
%
%
Min.
-50
Humidity (non condensing)
mW
---
60
150mA Slow-Blow Type
Conditions
A
---
---
---
Natural Convection
VDC
Max.
---
1000
MIL-HDBK-217F@25℃, Ground Benign
Input Fuse
Typ.
1000
500 VDC
Unit
Typ.
Max.
±1.0
±3.0
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
50
75
±0.01
±0.02
0.5 Second Max.
-----
Conditions
I/O Isolation Voltage (rated)
Typ.
Max.
5
5.5
12
13.2
15
16.5
24
26.4
--9
--18
--18
--30
--0.3
Internal Capacitor
--450
---
Conditions
General Specifications
2013/01/23 REV:4
Min.
4.5
10.8
13.5
21.6
-0.7
-0.7
-0.7
-0.7
---
Free-Air convection
---
+85
+125
℃
℃
95
% rel. H
260
℃
MAU100 SERIES
DC/DC CONVERTER 1W, SIP-Package
Power Derating Curve
100
Output Power (%)
Natural
Convection
20LFM
80
100LFM
60
200LFM
400LFM
40
20
0
-40
~
0
20
40
60
80
100 110
Ambient Temperature C
(3.3V, 5V & ±5V}
Notes
1
2
3
4
5
6
7
(all other output)
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
Pin
19.5 [0.77]
2.54
5.08
2X2.54
[0.10]
[0.20]
[2X0.10]
4
5
[0.13]
3.2
0.5
[0.02]
2.4
[0.09]
2
10.2 [0.40]
0.5 [0.02]
1
6
Single Output
+Vin
Dual Output
-Vin
-Vout
No Pin
+Vout
+Vin
-Vin
-Vout
Common
+Vout
T: 6.1mm(0.24 inch) for 5V&12V Input Models
T: 7.1mm(0.28 inch) for 15V&24V Input Models
18.5 [0.73]
T
Bottom View
4
5
6
0.50
[0.02]
Physical Characteristics
Case Size (5V&12V Input)
Case Size (15V&24V Input)
19.5x6.1x10.2mm (0.77x0.24x0.40 inches)
19.5x7.1x10.2mm (0.77x0.28x0.40 inches)
:
Alloy 42
:
Weight (5V&12V Input)
Weight (15V&24V Input)
:
:
E-mail:[email protected]
2013/01/23 REV:4
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
2.2g
2.6g
Tel:886-6-2923150
Page 3 of 4
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
:
:
Case Material
Pin Material
0.25 [0.01]
2
1.3 [0.05]
1
X.XX±0.13 ( X.XXX±0.005)
►Pins ±0.05 (±0.002)
MAU100 SERIES
DC/DC CONVERTER 1W, SIP-Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Technical Notes
Maximum Capacitive Load
The MAU100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 100µF maximum capacitive load for dual outputs and 220µF capacitive load
for single outputs. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω
at 100 KHz) capacitor of a 2.2µF for the 5V input devices, a 1.0µF for the 12V,15V input devices and a 0.47µF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.0µF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2013/01/23 REV:4
Page 4 of 4