MBU100 SERIES DC/DC CONVERTER 1W, SIP-Package FEATURES ►Miniature SIP-Package with Industry Standard Pinout ►Package Dimension: 11.5 x 10.2 x *6.1 mm (0.45”x 0.40”x 0.24”) 3.3V,5V&12V Models 11.5 x 10.2 x *7.1 mm (0.45”x 0.40”x 0.28”) 24V Models ►Single and Dual Output Models ►I/O-Isolation 1000 VDC ►Operating Temp. Range -40°C to +85°C ►3 Years Product Warranty PRODUCT OVERVIEW The MINMAX MBU100 series is a range of 1W DC/DC converters in a miniature SIP Package featuring I/O-isolation of 1000VDC. A high efficiency allows an operating temperature range of –40°C to +85°C. These converters offer an economical solution for many space critical applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination, digital interfaces or for board level power distribution. Model Selection Guide Model Number MBU135 MBU131 MBU105 MBU101 MBU102 MBU103 MBU104 MBU111 MBU112 MBU113 MBU114 MBU121 MBU122 MBU123 MBU124 Input Voltage (Range) VDC 3.3 (2.97 ~ 3.63) 5 (4.5 ~ 5.5) 12 (10.8 ~ 13.2) 24 (21.6 ~ 26.4) Output Voltage VDC 3.3 5 3.3 5 9 12 15 5 9 12 15 5 9 12 15 Input Specifications Parameter Input Surge Voltage (1 sec. max.) Reverse Polarity Input Current Internal Filter Type Internal Power Dissipation 2013/01/24 REV:5 Max. Min. mA 260 200 260 200 110 84 67 200 110 84 67 200 110 84 67 mA 6 4 6 4 2 1.5 1 4 2 1.5 1 4 2 1.5 1 Model 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models Input Voltage Range E-mail:[email protected] Output Current All Models Tel:886-6-2923150 Page 1 of 4 Input Current @Max. Load @No Load mA(typ.) 351 394 238 290 260 262 258 117 107 106 105 60 54 53 53 mA(typ.) 35 30 13 7 Min. 2.97 4.5 10.8 21.6 -0.7 -0.7 -0.7 -0.7 ----- Load Regulation Max. capacitive Load % (max.) 14 14 11 11 8 7 6 9 5 5 4 8 5 4 4 µF 33 33 33 33 Typ. Max. 3.3 3.63 5 5.5 12 13.2 24 26.4 --6 --9 --18 --30 --0.3 Internal Capacitor --450 Efficiency (typ.) @Max. Load % 74 77 72 69 76 77 78 71 77 79 80 70 76 79 79 Unit VDC A mW MBU100 SERIES DC/DC CONVERTER 1W, SIP-Package Output Specifications Parameter Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise Temperature Coefficient Short Circuit Protection Conditions Min. ----- For Vin Change of 1% Io=20% to 100% max. 20MHz Bandwidth General Specifications Parameter Typ. Max. ±1.0 ±3.0 ±1.2 ±1.5 See Model Selection Guide 100 150 ±0.01 ±0.02 0.5 Second Max. ----- Conditions Min. Typ. Unit % % mV P-P %/℃ Max. I/O Isolation Voltage (rated) 60 Seconds 1000 I/O Isolation Capacitance 100KHz, 1V --- 60 100 2,000,000 --- --- I/O Isolation Resistance 500 VDC Switching Frequency MTBF (calculated) 1000 MIL-HDBK-217F@25℃, Ground Benign Input Fuse 3.3V Input Models 5V Input Models 800mA Slow-Blow Type 500mA Slow-Blow Type Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature --- --- 50 90 Storage Temperature Range Min. Max. Unit --- +90 ℃ -40 +85 +125 Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) Hours 24V Input Models --- Cooling pF KHz 100mA Slow-Blow Type -50 Humidity (non condensing) MΩ 110 12V Input Models Ambient VDC --- 200mA Slow-Blow Type Conditions Unit --- --- ℃ ℃ 95 % rel. H 260 ℃ Output Power (%) Output Power (%) Power Derating Curve (5V Output Only) Notes 1 2 3 4 5 6 7 (All Other Output) Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Ripple & Noise measurement bandwidth is 0-20MHz. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. All DC/DC converters should be externally fused at the front end for protection. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. E-mail:[email protected] 2013/01/24 REV:5 Tel:886-6-2923150 Page 2 of 4 MBU100 SERIES DC/DC CONVERTER 1W, SIP-Package Package Specifications Mechanical Dimensions Pin Connections 11.5 [0.45] 10.2 [0.40] -Vout 4 [0.13] 0.5 [0.02] -Vin +Vout T: 6.1mm(0.24 inch) for 3.3V&5V&12V Input Models T: 7.1mm(0.28 inch) for 24V Input Models 3 1.8 [0.07] 0.25 [0.01] ►All dimensions in mm (inches) 4 T 2 Bottom View 0.50 [0.02] Case Size(3.3V, 5V, 12V Input) Case Size(24V Input) : : 11.5x6.1x10.2mm (0.45x0.24x0.40 inches) 11.5x7.1x10.2mm (0.45x0.28x0.40 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Alloy 42 Weight(3.3V, 5V, 12V Input) Weight(24V Input) : : 1.3g 1.7g 2013/01/24 REV:5 +Vin 3 3X2.54 1 E-mail:[email protected] 2 [3X0.10] 10.5 [0.41] Physical Characteristics Function 1 3.2 0.5 [0.02] 1.9 [0.07] Pin Tel:886-6-2923150 Page 3 of 4 ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pins ±0.05(±0.002) MBU100 SERIES DC/DC CONVERTER 1W, SIP-Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip Technical Notes Maximum Capacitive Load The MBU100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 33µF maximum capacitive load for devices. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is comended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 2.2µF for the 3.3V, 5V input devices, a 1.0µF for the 12V input devices and a 0.47µF for the 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1µF capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin Cout Load -Out Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2013/01/24 REV:5 Page 4 of 4