MPW2000 SERIES - MINMAX Technology

®
MPW2000 SERIES
DC/DC CONVERTER 30W, Single & Dual Output
FEATURES
►2”x 1.6”x 0.4” Metal Package
►Ultra-wide 4:1 Input Range
►Operating Temp. Range –40°C to +80°C
►Short Circuit Protection
►I/O-isolation 1500 VDC
►Input Filter meets EN 55022,class A and FCC, level A
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MPW2000 series is a range of isolated 30W DC/DC converter modules featuring fully regulated output voltages and ultra-wide 4:1 input
voltage ranges.The product comes in a 2”x 1.6”x 0.4” metal package with industry standard pinout. An excellent efficiency allows an operating temperature
range of –40° to +80°C (with derating).
Typical applications for these converters are battery operated equipment and instrumentation, distributed power systems, data communication and general
industrial electronics.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MPW2031
MPW2032
MPW2033
MPW2034
MPW2036
MPW2037
MPW2041
MPW2042
MPW2043
MPW2044
MPW2046
MPW2047
VDC
3.3
5
12
15
±12
±15
3.3
5
12
15
±12
±15
24
(10 ~ 40)
48
(18 ~ 75)
Output Current
Input Current
Reflected
Over
Max. capacitive
Ripple
Voltage
Load
Max.
Min.
@Max. Load
@No Load
Current
Protection
mA
5500
5000
2500
2000
±1250
±1000
5500
5000
2500
2000
±1250
±1000
mA
400
350
166
133
±83
±65
400
350
166
133
±83
±65
mA(typ.)
922
1225
1404
1404
1404
1404
461
613
702
702
702
702
mA(typ.)
mA (typ.)
20
50
10
25
VDC
3.9
6.8
15
18
±15
±18
3.9
6.8
15
18
±15
±18
Efficiency
(typ.)
@Max. Load
μF
10000
10000
1000
1000
330#
330#
10000
10000
1000
1000
330#
330#
%
82
85
89
89
89
89
82
85
89
89
89
89
# For each output
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Model
Min.
Typ.
Max.
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
24V Input Models
9.4
9.7
10
48V Input Models
17
17.5
18
24V Input Models
9
9.3
9.5
48V Input Models
16
16.5
17
---
---
2
Reverse Polarity Input Current
Short Circuit Input Power
All Models
Internal Power Dissipation
Conducted EMI
VDC
A
---
---
4500
mW
---
---
5500
mW
Compliance to EN 55022,class A and FCC part 15,class A
E-mail:[email protected]
2012/03/19 REV:7
Unit
Tel:886-6-2923150
Page 1 of 6
®
MPW2000 SERIES
DC/DC CONVERTER 30W, Single & Dual Output
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
%Vom.
Output Voltage Setting Accuracy
At 50% Load and Nominal Vin
---
---
±1.0
Output Voltage Balance
Dual Output, Balanced Loads
---
±0.5
±2.0
%
Line Regulation
Vin=Min. to Max.
---
±0.2
±0.5
%
Load Regulation
Io=50% to 100%
---
±0.3
±1.0
%
---
55
80
mV P-P
---
150
300
μsec
---
±2
±4
%
---
±0.01
±0.02
%/℃
107
112
117
℃
120
---
180
%
Ripple & Noise (20MHz)
Transient Recovery Time
25% Load Step Change
Transient Response Deviation
Temperature Coefficient
Over Temperature Protection
Case Temperature, automatic recovery
Over Load Protection
Output Short Circuit
Continuous
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
I/O Isolation Voltage Rated
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Safety Approvals
---
1200
1500
pF
290
330
360
KHz
450,000
---
---
Hours
UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1(CB-scheme)
Input Fuse
24V Input Models
48V Input Models
5000mA Slow-Blow Type
3000mA Slow-Blow Type
Remote On/Off Control
Parameter
Conditions
Min.
Converter On
Typ.
Max.
Unit
2.5V ~ 100V or Open Circuit
Converter Off
-1V ~ 1V or Short Circuit
Control Input Current (on)
Vctrl = 5.0V
---
---
5
μA
Control Input Current (off)
Vctrl = 0V
---
---
-100
μA
2
5
mA
Control Common
Referenced to Negative Input
Standby Input Current
Nominal Vin
---
Output Voltage Trim
Parameter
Trim Up / Down Range
Conditions
Min.
Typ.
Max.
Unit
% of nominal output voltage
±9.0
±10.0
±11.0
%
Environmental Specifications
Parameter
Conditions
Min.
Max.
Unit
Natural Convection
-40
+80
℃
Case Temperature Range
---
+105
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
Operating Ambient Temperature Range (See Power Derating Curve)
Cooling
Free-Air convection
RFI
Six-Sided Shielded, Metal Case
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2012/03/19 REV:7
Tel:886-6-2923150
Page 2 of 6
---
260
℃
®
MPW2000 SERIES
DC/DC CONVERTER 30W, Single & Dual Output
Power Derating Curve
100
Output Power (%)
80
Natural
convection
100LFM
60
200LFM
400LFM
40
20
0
~
-40
0
20
40
60
Ambient Temperature C
Derating Curve without Heatsink
Derating Curve with Heatsink
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage, rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3
Ripple & Noise measurement bandwidth is 0-20 MHz.
4
These power converters require a minimum output loading to maintain specified regulation.
5
Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6
All DC/DC converters should be externally fused at the front end for protection.
7
Other input and output voltage may be available, please contact factory.
8
To order the converter with heatsink, please add a suffix H. (e.g. MPW2031H).
9
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
10
Specifications subject to change without notice.
E-mail:[email protected]
2012/03/19 REV:7
Tel:886-6-2923150
Page 3 of 6
80
100 110
®
MPW2000 SERIES
DC/DC CONVERTER 30W, Single & Dual Output
Package Specifications
Mechanical Dimensions
Pin Connections
7
8
1.1
[0.04]
Bottom View
1
2
5.08
[0.20]
3.6
[0.14]
1.0
[ 0.04]
6
5.08
[0.20]
45.72 [1.80]
5
10.16
[0.40]
50.8 [2.00]
10.16
[0.40]
10.16
[0.40]
Pin
Single Output
Dual Output
1
+Vin
+Vin
2
-Vin
-Vin
4
Remote On/Off
Remote On/Off
5
No Pin
+Vout
6
+Vout
Common
7
-Vout
-Vout
8
Trim
Trim
4
10.16
[0.40]
►All
7.6
[0.30]
6.0
[0.24]
40.6 [1.60]
10.2
[0.40]
dimensions in mm (inches)
►Tolerance: X.X±0.25
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
pitch tolerance: ±0.25 (0.01)
Physical Characteristics
Case Size
:
50.8x40.6x10.2mm (2.0x1.6x0.4 Inches)
Case Material
:
Metal With Non-Conductive Baseplate
Base Material
:
FR4 PCB (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Underplate
Weight
:
48g
Physical Characteristics
23.0[0.91]
Heat-sink
Heatsink Material
:
Aluminum
Finish
:
Anodic treatment (black)
Weight
:
15g
17.2[0.68]Max
55.32[2.18]Max
Heat-sink
Thermal pad
Clamp
Converter
►The
advantages of adding a heatsink are:
1. To help heat dissipation and increase the stability
and reliability of DC/DC converters at high
operating temperature atmosphere.
2. To upgrade the operating temperature of DC/DC
converters, please refer to Derating Curve.
E-mail:[email protected]
2012/03/19 REV:7
Tel:886-6-2923150
Page 4 of 6
®
MPW2000 SERIES
DC/DC CONVERTER 30W, Single & Dual Output
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a 1μF ceramic capacitor and a 10μF tantalum capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz.
Position the load between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Cout
Cout
Scope
Resistive
Load
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low.
To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal.
The switch can be an open collector or equivalent. A logic low is -1V to 1.0V. A logic high is 2.5V to 100V. The maximum sink current at the on/off terminal (Pin
4) during a logic low is -100 μA. The maximum allowable leakage current of a switch connected to the on/off terminal (Pin 4) at logic hight (2.5V to 100V) is 5μA.
Output Voltage Trim
Output voltage trim allows the user to increase or decrease the output voltage set point of a module. The output voltage can be adjusted by placing an external
resistor (Radj) between the Trim and +Vout or -Vout terminals. By adjusting Radj, the output voltage can be change by ±10% of the nominal output voltage.
+Vin
+Out
-Vin
-Out
Enable
Trim
Trim Down
10K
Trim
Up/Down
Trim Up
A 10K, 1 or 10 Turn trimpot is usually specified for continuous trimming. Trim pin may be safely left floating if it is not used.
Connecting the external resistor (Radj-up) between the Trim and -Vout pins increases the output voltage to set the point as defined in the following equation:
Radj - up =
(33 × Vout ) - (30 × Vadj)
Vadj - Vout
Connecting the external resistor (Radj-down) between the Trim and +Vout pins decreases the output voltage set point as defined in the following equation:
Radj - down =
(36.667 × Vadj) - (33 × Vout )
Vout - Vadj
Vout: Nominal Output Voltage
Vadj: Adjusted Output Voltage
Units: VDC/KΩ
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals.
The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output
overvoltage. The OVP level can be found in the output data.
E-mail:[email protected]
2012/03/19 REV:7
Tel:886-6-2923150
Page 5 of 6
®
MPW2000 SERIES
DC/DC CONVERTER 30W, Single & Dual Output
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 33μF for the 24V input devices and a 10μF for the 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 4.7μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
+Vin
DC Power
Source
Load
-Out
-
+Out
Dual Output
Com.
DC / DC
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MPW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃.
The derating curves are determined from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2012/03/19 REV:7
Page 6 of 6