FM4007W THRU FM4001W

FM4001W
THRU
FM4007W
SURFACE MOUNT SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere
FEATURES
* Ideal for surface mounted applications
* Low leakage current
* Metallurgically bonded construction
* Mounting position: Any
* Weight: 0.078 gram
SMX
MECHANICAL DATA
* Epoxy : Device has UL flammability classification 94V-0
.209 (5.31)
.185 (4.70)
.051 (1.30)
.091 (2.31)
.011 (0.28)
.007 (0.18)
.067 (1.70)
.180 (4.57)
.008 (0.20)
.071 (1.80)
.086 (2.18)
.010 (0.25)
.110 (2.79)
.160 (4.06)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.059 (1.50)
Ratings at 25 O C ambient temperature unless otherwise specfied.
Resistive or inductive load.
.035 (0.89)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
FM4001W
FM4002W
FM4003W
FM4004W
FM4005W
FM4006W
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Vol ts
VDC
50
100
200
400
600
800
1000
Vol ts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Ambient Temperatu re
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Square Time
FM4007W UNITS
Vol ts
IO
1.0
Amps
I FSM
30
Amps
I 2T
3.7
A 2S
Typical Thermal Resistance (Note 1)
RqJA
80
0
Typical Thermal Resistance (Note 1)
RqJL
30
0
Typical Junction Capacitance (Note 2)
CJ
15
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
C/W
C/W
pF
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 1.0A DC
SYMBOL
FM4001W
VF
Maximum Full Load Reverse Current,
Full cycle Average at T A=75 OC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
IR
NOTES : 1. Thermal Resistance :Mounted on PCB.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. "Fully ROHS compliant","100% Sn plating (Pb-free)".
FM4002W
FM4003W
FM4004W
FM4005W
FM4006W
FM4007W UNITS
1.1
Vol ts
30
uA
5.0
uA
100
uA
2009 -08
REV: B
2.0
1.5
1.0
Single Phase Half Wave 60Hz
Resistive or Inductive Load
0.375" (9.5mm) Lead Length
0.5
0
25
0
50
75
100
125
150
175
1000
INSTANTANEOUS FORWARD CURRENT, ( uA)
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( FM4001W THRU FM4007W )
100 TA = 100 OC
TA = 75 OC
10
TA = 25 OC
1.0
0.1
0.01
0
20
CJ, JUNCTION CAPACITANCE, (pF)
20
10
1.0
0.1
TJ = 25 OC
Pulse width=300 S
1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
3.0
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
3.5
4.0
4.5
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
40
TJ = 25 OC
20
10
8
6
4
2
1
5.0
0.1
0.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
4
1.0
40 80
FIG.4 TYPICAL JUNCTION CAPACITANCE
30
8.3mS Single Half Sine-Wave
JEDEC Method
25
20
15
10
0
1
10
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (A)
Lead Temperature (OC)
2
4
6
8 10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Mounting Pad Layout
0.074 MAX.
(1.88 MAX.)
0.066MIN.
( 1.68 MIN.)
0.060 MIN.
(1.52 MIN.)
0.208
( 5.28) REF
Dimensions in inches and (millimeters)
Marking Description
A X
Part No.
Voltage-code
V Y W W 1-------50V
Cathode Band
Plant - code
Year – code
(Y, Last digit of year)
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-------1000V
Week – code
(ww,01~52)
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
REEL PACK
PACKAGE
PACKING EA PER
REEL
CODE
COMPONENT TAPE SPACE
SPACE(mm)
(mm)
REEL DIA
CARTON SIZE
(mm)
(mm)
EA PER
GROSS
CARTON WEIGHT(Kg)
SMX
-T
1,500
---
---
180
390*205*310
48,000
---
SMX
-W
5,000
---
---
330
355*360*350
80,000
15.20
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.