FM4001W THRU FM4007W SURFACE MOUNT SILICON RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere FEATURES * Ideal for surface mounted applications * Low leakage current * Metallurgically bonded construction * Mounting position: Any * Weight: 0.078 gram SMX MECHANICAL DATA * Epoxy : Device has UL flammability classification 94V-0 .209 (5.31) .185 (4.70) .051 (1.30) .091 (2.31) .011 (0.28) .007 (0.18) .067 (1.70) .180 (4.57) .008 (0.20) .071 (1.80) .086 (2.18) .010 (0.25) .110 (2.79) .160 (4.06) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS .059 (1.50) Ratings at 25 O C ambient temperature unless otherwise specfied. Resistive or inductive load. .035 (0.89) Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) SYMBOL FM4001W FM4002W FM4003W FM4004W FM4005W FM4006W Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Vol ts VDC 50 100 200 400 600 800 1000 Vol ts RATINGS Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at Ambient Temperatu re Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Square Time FM4007W UNITS Vol ts IO 1.0 Amps I FSM 30 Amps I 2T 3.7 A 2S Typical Thermal Resistance (Note 1) RqJA 80 0 Typical Thermal Resistance (Note 1) RqJL 30 0 Typical Junction Capacitance (Note 2) CJ 15 Operating Temperature Range TJ 150 0 C T STG -55 to + 150 0 C Storage Temperature Range C/W C/W pF ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 1.0A DC SYMBOL FM4001W VF Maximum Full Load Reverse Current, Full cycle Average at T A=75 OC Maximum Average Reverse Current @T A = 25 o C at Rated DC Blocking Voltage @T A = 100 o C IR NOTES : 1. Thermal Resistance :Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant","100% Sn plating (Pb-free)". FM4002W FM4003W FM4004W FM4005W FM4006W FM4007W UNITS 1.1 Vol ts 30 uA 5.0 uA 100 uA 2009 -08 REV: B 2.0 1.5 1.0 Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375" (9.5mm) Lead Length 0.5 0 25 0 50 75 100 125 150 175 1000 INSTANTANEOUS FORWARD CURRENT, ( uA) AVERAGE FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( FM4001W THRU FM4007W ) 100 TA = 100 OC TA = 75 OC 10 TA = 25 OC 1.0 0.1 0.01 0 20 CJ, JUNCTION CAPACITANCE, (pF) 20 10 1.0 0.1 TJ = 25 OC Pulse width=300 S 1% Duty Cycle 0 0.5 1.0 1.5 2.0 2.5 3.0 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE 3.5 4.0 4.5 FIG.2 TYPICAL REVERSE CHARACTERISTICS 40 TJ = 25 OC 20 10 8 6 4 2 1 5.0 0.1 0.4 INSTANTANEOUS FORWARD VOLTAGE, (V) 4 1.0 40 80 FIG.4 TYPICAL JUNCTION CAPACITANCE 30 8.3mS Single Half Sine-Wave JEDEC Method 25 20 15 10 0 1 10 REVERSE VOLTAGE, (V) FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS REVERSE CURRENT, (A) Lead Temperature (OC) 2 4 6 8 10 20 40 80 100 NUMBER OF CYCLES AT 60Hz FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT Mounting Pad Layout 0.074 MAX. (1.88 MAX.) 0.066MIN. ( 1.68 MIN.) 0.060 MIN. (1.52 MIN.) 0.208 ( 5.28) REF Dimensions in inches and (millimeters) Marking Description A X Part No. Voltage-code V Y W W 1-------50V Cathode Band Plant - code Year – code (Y, Last digit of year) 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V Week – code (ww,01~52) PACKAGING OF DIODE AND BRIDGE RECTIFIERS REEL PACK PACKAGE PACKING EA PER REEL CODE COMPONENT TAPE SPACE SPACE(mm) (mm) REEL DIA CARTON SIZE (mm) (mm) EA PER GROSS CARTON WEIGHT(Kg) SMX -T 1,500 --- --- 180 390*205*310 48,000 --- SMX -W 5,000 --- --- 330 355*360*350 80,000 15.20 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.